Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00105 - 820 W 7th S - Rockwell Court Apts Bldg #3Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/03/2020 11:08 am Permit Details Permit Number: 12-00105 820 W 7th S - Rockwell Court Apts Bldg #3 820 W 7th S New Multi-Family Residence Permit Issued Date: 04/01/2014 Permit Inspection Statistics 20Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 90.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 02/25/2013PassQuinton OwensFoundation Inspection 2/22: Partial foundation (South, West, & partial North). Ufer installed. approved. 2/25: Remaining foundation ok to pour - rebar per plans. Inspector Comments: 02/28/2013PassQuinton OwensFooting Inspection 2/20: Exterior footings w/ 3 #4 bar cont - approved (int. footings. not ready) Interior ok (2/28) Inspector Comments: 4/25 - missed nailing a few locations (as marked). Action Required: reinspect with framing. Inspector Comments: 5/21 - Missed locations marked with red crayon. Action required: reinspect. Inspector Comments: 05/24/2013PassQuinton OwensSheeting 5/24 - Exterior locations corrected.Inspector Comments: 6/5,QO: Some penetrations not firecaulked. Blocking needed at rim board for bldg straps. Inspector Comments: 6/10,QO: Firecaulk vent pipe at intersecting wall (East end unit). Concealed locations at ceiling not rated yet. Seal penetrations at truss over stairwell separation. Truss blocks on east end unit at upper floor interior. Inspector Comments: 06/17/2013PassQuinton OwensFraming/Structure Inspection 6/17,QO: Framing items done (except sealing around truss penetrations at stairwell not inspected) Inspector Comments: 6/17,QO: Upper floor & West end units approved for taping.Inspector Comments: 06/19/2013PassQuinton OwensSheetrock/Drywall Inspection 6/19,QO: Lower and East end units approved.Inspector Comments: 08/21/2013FailQuinton OwensBuilding Final Vapor barrier not done (3104,3103). Vents missing connecting lower to upper attic (3104). Stud missing in crawl space (NE portion of 3102). Inspector Comments: 6/10,QO: Vent baffles needed between lower & upper attics in end units.Inspector Comments: 6/17,QO: Vent baffles not in at conjunction between lower and upper roof on end units. Inspector Comments: 08/23/2013PassQuinton OwensInsulation Inspection 8/23,QO: baffles installed at final reinspect.Inspector Comments: 08/23/2013PassQuinton OwensBuilding Final Page 1 of 2 (Continued) Permit Details Permit Number: 12-00105 820 W 7th S - Rockwell Court Apts Bldg #3 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/03/2020 11:08 am Permit Inspection Summary Electrical Inspection Type 06/03/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover-inspected the electrical service, and fire alarm wiring for cover on this inspection. Inspector Comments: 06/03/2013PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection and no separate ticket was written. Inspector Comments: 08/21/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-inspected the fire alarm also on this inspection-inspected yesterday for the final electrical and changes were done that were needed. Inspector Comments: Fire Inspection Type 06/03/2013PassBret StoddardFire Alarm Rough-in Approved for cover-inspected the fire alarm wiring on the electrical rough-in inspection and no separate ticket was written. Inspector Comments: 08/21/2013PassBret StoddardFire Alarm Final Inspection Approved for a final and C.O.-inspected the fire alarm on the electrical final-witnessed 24 hour/5 minute test and all functions of initiating and signalling devices-fire alarm contractor report in file-flow switch was 42 seconds. Inspector Comments: Mechanical Inspection Type 05/15/2013PassQuinton OwensHVAC Rough-in Venting for water heater not installed yet. One gas line below 20 psi. (Plumbers working on it) Inspector Comments: 08/21/2013FailQuinton OwensHVAC Final Inspection Insulate supply boot under back right bdrm in 3102.Inspector Comments: 08/23/2013PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 07/02/2013PassDon AllenPlumbing Rough-in 5/30 - all good to cover rough in.Inspector Comments: 07/09/2013PassDon AllenPlumbing Water good to cover water line for apt 1,2,3,7,8,9Inspector Comments: 09/03/2013PassDon AllenPlumbing Sewer 09/03/2013PassDon AllenPlumbing Final Inspection 8/13/13 - all good for the C/OInspector Comments: Page 2 of 2