HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00104 - 820 W 7th S - Rockwell Court Apts Bldg #2Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/03/2020 10:53 am
Permit Details Permit Number: 12-00104
820 W 7th S - Rockwell Court Apts Bldg #2
820 W 7th S
New Multi-Family Residence
Permit Issued Date: 04/01/2014
Permit Inspection Statistics
20Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 85.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
02/04/2013PassQuinton OwensFooting Inspection
2-01: Partial footing (south half) 3 #4 bars cont. and supported. approved- QO.
2-04: North half approved.
Inspector Comments:
02/08/2013PassQuinton OwensFoundation Inspection
2/6: Partial foundation. Poured with no inspection request on hotline. Strata's
special inspector said he everything looked good from his inspection.
2/8: Ufer installed. 4 #4 horiz. rebar. Vert. #4 bars at 16" oc.
Inspector Comments:
05/09/2013PassQuinton OwensFraming/Structure Inspection
4/2, QO: Sheathing - Missed nailing (marked inside on studs in red crayon). Nail
connection ties under eaves on upper roof at side.(disapproved)
4/25, QO: Rating under Tubs?, Finish caulking attic penetrations, firecaulk 1st
floor top plate (except end units), exhaust fan missing in west end unit.
5/7,QO: Framing approved (replace missing partition studs).
Inspector Comments:
05/09/2013PassQuinton OwensInsulation Inspection
05/22/2013PassQuinton OwensSheetrock/Drywall Inspection
5-16, QO: All units, except west end, approved. All 5/8" type x drywall glued and
fastened 24" oc
5/22,QO: West end ok to tape.
Inspector Comments:
07/19/2013FailQuinton OwensBuilding Final
-Multiple studs or headers missing in crawl space (2104,2103,2102)
-SW bedroom (uper floor 2104) smk det. not interconnected.
-Stud/heards missing in crawl space (2103)
-No vapor barrier in crawl space (2102)(2101)
-Reserve horizontal grab bars by toilet. (2102)
-Closet door knobs in 2102 meet ADA?
-Insulation falling in 2101 crawl space.
Inspector Comments:
08/08/2013PassQuinton OwensBuilding Final
7/25,QO: Building final approved EXCEPT accessible unit which needs horizontal
grab bars switched.
8/8,QO: completed.
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00104
820 W 7th S - Rockwell Court Apts Bldg #2
820 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 01/03/2020 10:53 am
Permit
Inspection
Summary
Electrical Inspection Type
04/26/2013PassBret StoddardCOM & MFR Electrical Service Inspection
Approved to be energized for permanent power-inspected the service on the
rough-in inspection on same ticket also.
Inspector Comments:
04/26/2013PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in
Approved for cover in the entire building-inspected the electrical service and the
fire alarm wiring also on the same ticket.
Inspector Comments:
07/24/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved for a final and C.O.-inspected this building entirely on 7/18, this is a
re-inspect.
Inspector Comments:
Fire Inspection Type
04/26/2013PassBret StoddardFire Alarm Rough-in
Approved for cover in the entire building-inspected the fire alarm wiring on the
rough-in inspection.
Inspector Comments:
07/24/2013PassBret StoddardFire Alarm Final Inspection
Approved for a final and C.O.-witnessed fire alarm test 24 hour 5 minute, flow
test-35 seconds, DB witnessed at 80 DB at pillow level in bedrooms, smoke
detectors tested, final report from fire alarm contractor is in permit 12-103.
Inspector Comments:
Mechanical Inspection Type
04/22/2013PassDon AllenHVAC Rough-in
all good to cover mech rough-in.Inspector Comments:
07/19/2013FailQuinton OwensHVAC Final Inspection
Water? in duct in crwl spc.(2102, 2104). Water damage to insulated duct (2101).
Duct disconnected (2103). Add support for duct near front of crwl spc (2103).
Inspector Comments:
07/25/2013PassQuinton OwensHVAC Final Inspection
7/18/13 DA: HVAC all good.Inspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00104
820 W 7th S - Rockwell Court Apts Bldg #2
820 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 01/03/2020 10:53 am
Permit
Inspection
Summary
Plumbing Inspection Type
05/28/2013PassDon AllenPlumbing Rough-in
4/19/13 - rough in is all good to coverInspector Comments:
07/09/2013PassDon AllenPlumbing Water
Good to cover water line for apt 1,2,3,7,8,9.Inspector Comments:
07/15/2013FailDon AllenPlumbing Final Inspection
Check over flow on tubs
Dish washer installed
Washer box covers
Ball value in main line
Dubble check tested.
Inspector Comments:
07/18/2013PassDon AllenPlumbing Final Inspection
Plumbing all good.Inspector Comments:
07/19/2013PassDon AllenPlumbing Sewer
Page 3 of 3