Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00103 - 820 W 7th S - Rockwell Court AptsPermit Inspection Summary Permit Status of (Open) as of Report Date: 01/03/2020 10:52 am Permit Details Permit Number: 12-00103 820 W 7th S - Rockwell Court Apts Bldg #1 820 W 7th S New Multi-Family Residence Permit Issued Date: 03/31/2014 Permit Inspection Statistics 23Total Inspections Completed: 19Total Inspections Passed: Inspection Pass Rate: 82.61% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 02/07/2013PassQuinton OwensFooting Inspection 3 #4's cont. spot ftg rebar Ok to pour Special Inspector (Strata) on site. Inspector Comments: 02/13/2013PassQuinton OwensFoundation Inspection 4 #4 horiz, and vert. #4 bars at 16" oc. Ufer ground installed. Inspector Comments: 04/18/2013FailQuinton OwensSheeting Missed locations marked with crayon on studs. (to be reinspected with framing) Inspector Comments: 05/28/2013FailQuinton OwensFraming/Structure Inspection Firecaulk penetrations and openings in rated separation wall (incl. gaps at roof truss). Backing for HC grab bars in restrooms is too high and missing vertical bar backing. Truss ties not nailed in SW corner. Hold downs fastened to single stud (SE corner by window). Inspector Comments: 05/29/2013PassQuinton OwensFraming/Structure Inspection Framing ok to insulate.Inspector Comments: 05/31/2013PassTed DyeInsulation Inspection club house insulation only all windows and doors sealed all exterior and separation walls insulated Inspector Comments: 06/07/2013FailQuinton OwensSheetrock/Drywall Inspection 6/5,QO: Drywall OK to tape in Manager's Unit. Ok to tape all but rated wall in laundry room. (Drywall needed around washer boxes in stud cavity for 1 hr rating). Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00103 820 W 7th S - Rockwell Court Apts Bldg #1 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/03/2020 10:52 am Permit Inspection Summary 07/15/2013FailQuinton OwensBuilding Final No anchor bolts on crawl space bearing walls. Under sink protection needed in HC restrooms. Fire rate penetrations in rated walls & ceilings. Holes in interior foundation not rated. Mgr unit smk det. not interconnected (main flr hall). Water heater not yet installed in Mech. rm. (where is condensate drain?). Paving/prking not done. Inspector Comments: 07/25/2013PassQuinton OwensSheetrock/Drywall Inspection 07/25/2013PassQuinton OwensBuilding Final *Previous problems corrected* Done Inspector Comments: Electrical Inspection Type 05/16/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover-managers unit, commons area and storage area on the east side-no fire alarm wire is installed yet in the entire building. Inspector Comments: 05/31/2013PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 07/24/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-inspected this building entirely on 7/18, this is a re-inspect. Inspector Comments: Fire Inspection Type 05/23/2013PassBret StoddardFire Alarm Rough-in Approved for cover-fire alarm and security system throughout entire building.Inspector Comments: 06/26/2013PassDale PickeringFire Sprinkler Rough-in Main Line/Fire Risers/Pressure Test - 13:15 - 210# 15:15 - 210# approved. Inspector Comments: 07/24/2013PassBret StoddardFire Alarm Final Inspection Approved for a final and C.O.-witnessed fire alarm test 24 hour 5 minute, DB witnessed at 80 DB at pillow level in bedrooms, smoke/heat detectors tested, final report from fire alarm contractor is in this permits file. Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00103 820 W 7th S - Rockwell Court Apts Bldg #1 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/03/2020 10:52 am Permit Inspection Summary Mechanical Inspection Type 05/02/2013PassQuinton OwensHVAC Rough-in Seal boom corners of return air for furnace supplying common area.Inspector Comments: 07/25/2013PassQuinton OwensHVAC Final Inspection 7/15,QO:Vent penetrations in Mech. room not fire rated.(see bldg final). Water Heater Condensate drain found extended to drain. Furnace hooked up to gas. 7/25,QO: done Inspector Comments: Plumbing Inspection Type 03/12/2013PassDon AllenPlumbing Underground Inspection mechanical RoomInspector Comments: 05/28/2013PassDon AllenPlumbing Rough-in 4/19/13 DA: rough in all good to cover.Inspector Comments: 07/09/2013PassDon AllenPlumbing Water 07/18/2013PassDon AllenPlumbing Final Inspection 7/15: bathroom floor drain needs clean out. water heater needs put in. check over flow on taps. Ball value on main line. Double check tested. **Disapproved** 7/18 - All goo din the plumbing. Inspector Comments: 07/19/2013PassDon AllenPlumbing Sewer Page 3 of 3