Loading...
HomeMy WebLinkAboutPLANS 2 - M19-00045 - Hayes - 3595 E 893 N - New SFRElevations Scale: 1/4" & 1/8" =1'-0" on 36" x 24" Paper Scale: 1/8" & 1/16"=1'-0" on 17" x 11" Paper A1 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO 10-31-18 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 9 Copyright Sundance Drafting and Design 2019 Copyright Sundance Drafting and Design 2019 1/8"=1'-0" UNO Start Date Permit SetBid Set TOTAL SQ. FTG.= 3462 MAIN FLOOR=1680/1600 INTERIOR BASEMENT=1782 GARAGE=1091 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Front Elevation Right Elevation 9', 10', & 12' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP Back Elevation Left Elevation 6:12 Pitch Main, 3:12 Pitch over Front & Back Porch Rev Ha y e s R e d s i d e n c e 12 6 12 3 12 3 12 6 12 3 12-18-18 Vertical Siding Faux Stone Asphalt Shingles Vertical Siding Vertical Siding PE R M I T S E T 01-16-19 12 6 03-04-1903-12-19 Foundation Plan Scale: 1/4"=1'-0" D Size PaperScale: 1/8"=1'-0" B Size Paper Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 12" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 Ø x14" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2012 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2015 IRC Section R106.1 over Undisturbed Soil Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. J WH Furnace WS A2A2 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO 10-31-18 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 9 Copyright Sundance Drafting and Design 2019 Copyright Sundance Drafting and Design 2019 1/8"=1'-0" UNO Start Date Permit SetBid Set Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM TOTAL SQ. FTG.= 3462 MAIN FLOOR=1680/1600 INTERIOR BASEMENT=1782 GARAGE=1091 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Walk-Out with 30" Frost Depth Footings below 2x6 insulated walls Rev Rev A5 of Rev Ha y e s R e d s i d e n c e 26 6 8 2x 6 W a l l 24 6 8 4060 F4060 F 4060 F 50 6 0 F 50 6 0 F 6x6 P o s t 16x 1 6 x 8 F o o t e r (10 T y p ) R e t a i n i n g W a l l Beam Beam 2668 Storage Under Stairs2668 Mech./ Storage 3' Clearance in front of Furnance Seismic Straps around WH Bedroom 2 14'-11" x 12'-10" 10 CFM Fresh Air Smoke Detector Bedroom 3 14'-7" x 14'-8" 10 CFM Fresh Air Smoke Detector Bath 50 CFM Open to Main Floor Above 40 4 0 S V J 30 6 8 6040 SV Walk Out Family Room 31'-8" x 13'-2" 10 CFM Fresh Air 9 10111213141516 87 1718 Up 17'-10"16'25'-6" 7' 15 ' - 1 1 " 8' 45 ' 59'-4" 9 ' - 4 " 33'-7 1/2" 6" 17'-5" 16'-2 1/2" 15 ' - 4 " 12 ' - 8 " 8' 45 ' 9' 5'-10"53'-6" 59'-4" 26'-6" 6' 6 ' 6 ' 6 ' - 2 " 1 0 ' - 8 " 6 ' - 2 " 2 3 ' 1 2 ' 3 5 ' 32'-6" TRIPLE CAR GARAGE 4" CONCRETE SLAB SLOPE CONC. FLOOR TO DRAIN TO GARAGE DOOR HOLDDOWN: H1 SIMPSON STRONG TIE STHD14-INSTALLED & NAILED AS PER MANUFACTURERS RECOMMENDATIONS CONCRETE TO WOOD CONNECTION H1 H1 H1 H1 H1 H1 H1H1 Cut 3' for P a s s a g e Opening w i t h Req. Bloc k i n g Cut 9' for G a r a g e Door open i n g with Req. B l o c k i n g Cut 9' for G a r a g e Door open i n g with Req. B l o c k i n g Cut 9' for G a r a g e Door open i n g with Req. B l o c k i n g 4" Conc. P o u r Over Undis t u r b e d Soil 13 ' - 2 " 2'- 1 0 " 5'- 4 " 4'- 2 " 4'- 7 " 10'-6" 20 ' - 2 " 9' 17'-10" 7' 7' LN2' 2668 24 6 8 2068 2068 2068 2068 Possible Shelving or Bookcase Win d o w S e a t 40 4 0 S V Linen 2'- 4 " 10 ' 2'- 4 " Wo o d S t o v e 3068 Reloading Room 4040 SV4040 SV Higher Headers 8'-11"8'-11" 28' 14'14' 12'-9"12'-9" 12-18-18 9', 10', & 12' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP 7'-6"7'-10"2'-6" 5'- 3 " 3'- 9 " 3'-3"4'-9"4'-9"3'-3" 3'- 9 " 3'- 3 " 6'6'4' 6'- 2 " 4'- 6 " 5'- 3 " 9' Basement F. Walls Du c t Ch a s e Beam Beam Beam PE R M I T S E T 14 ' - 1 " Center Of Footing 16'3'-8"17'-8"16'-2"Ce n t e r Of F o o t i n g Center Of Footing Center Of Footing 6'- 7 " 6'- 1 " 4'- 1 0 " Center Of Footing 8'- 5 " 2'- 4 " 5' 5'- 4 " 8'- 1 1 " 16'3'-10"1'-5"4'-3" 2' T-Wall S CM 01-16-19 5'-11" 2'- 8 " 3'-10"15 ' - 6 1 / 2 " 7'- 1 0 1 / 2 " WIC WIC 1 6 5 ° 90°75° 105 ° H1 H1 03-04-1903-12-19 St e p p i n g F o u n d a t i o n H e r e Main Floor Scale: 1/4"=1'-0" D Size Paper Scale: 1/8"=1'-0" B Size Paper Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2015 IRC, Section R106 and R311.6 Saftey Glazing 2015 IRC, Sections R106 and R308.4.5 Furnace: Location of furnace and water heater 2012 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2015 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2015 IRC, Section R106, M1307.3.1 Crawl Space: Through Floor min 18"x24" or through perimeter wall min 16"x24" required crawl space opening. If applicable, refer to mechanical code for access requirements where mechanical equipment is located under floors. 2015 IRC, Section R106, R408.4 M1305.1.4 Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. A3 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO 10-31-18 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 9 Copyright Sundance Drafting and Design 2019 Copyright Sundance Drafting and Design 2019 1/8"=1'-0" UNO Start Date Permit SetBid Set TOTAL SQ. FTG.= 3462 MAIN FLOOR=1680/1600 INTERIOR BASEMENT=1782 GARAGE=1091 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Garage Portals: Alternate Braced Wall Panel Garage Portal Design PFH See Figure R602.10.6.2 Sheet A4 PFH 4'Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r IBWP 3 Interior Braced Wall Panel IBWP 2015 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3(IRC R602.10)2x4 Studs @ 16" O.C. w/7/16" OSBNailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 51/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. Rev Rev A5 of Rev Ha y e s R e d s i d e n c e 9x 9 O H G a r a g e D o o r 9x 9 O H G a r a g e D o o r 9x 9 O H G a r a g e D o o r 26 6 8 26 6 8 24 6 8 2x 6 W a l l 1 2 3 4 5 6 7 8 9 10111213 7" Foundation Ledge 2468 2468 P 2468 2x 6 W a l l 26 6 8 2 6 6 8 LN 30 6 8 26 6 8 30 6 8 30 6 8 Be n c h Main Floor: 1680 SF 11" Min. 11 " M i n . Great Room 15'-0" x 19'-6" 10 CFM Fresh Air 12' Flat Ceiling Dining 11'-4" x 17'-6" 10 CFM Fresh Air 10' Flat Ceiling Utility 50 CFM 80 WHF Entry 10' Ceiling Bedroom 1 13'-6" x 11'-2" 10 CFM Fresh Air 9' Vaulted Ceiling Smoke Detector Master Bedroom 13'-2" x 15'-2" 10 CFM Fresh Air 9' Vaulted Ceiling Smoke Detector Master Bath 50 CFM WIC Bath 50 CFM Open to Below 3 Car Garage 1091 Squ a r e F e e t Contracto r t o l o c a t e e x a c t location o f r e q ' d 2 2 " x 3 0 " Attic Acce s s P o i n t Min. 30" V e r t . H e a d R o o m Clearance ( 2 0 0 9 - R 8 0 7 . 1 ) 20 m i n F i r e R a t e d 1- 3 / 8 " S o l i d D o o r or E q u a l , S e l f C l o s e 1h r F i r e w a l l N o Pe n e t r a t i o n s 4050 SV Temp 4010 SV4050 F3030 SV 4050 SV 3050 SH 30 5 0 S H 30 5 0 S H 3050 SH2636 SH 4060 F4060 F 4060 F 50 6 0 F 50 6 0 F 4040 SV 30 6 8 4040 SV Va u l t 15 ' - 4 " 9' 17'-10"16'25'-6" 7' 30 ' 8' 53'-6" 6' 1 ' - 6 " 9 ' 1 ' - 6 " 1 ' - 8 " 9 ' 1 ' - 8 " 9 ' 1 ' - 8 " 3 5 ' 93'-11 1/2" 37 ' 8' 7' 6' 15' 15 ' 1'- 9 " 3'-6" 3'- 6 " 8'- 9 " 9', 10', 12' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP Railing Railing 10 ' F l a t 9' F l a t Wo o d S t o v e 30 6 8 26 6 8 3' 3010 Tra 3010 Tra 165 ° 8'-6" 8'-6" 26'-6" 32'-6" 4040 SV 9'-6" 4010 Tra H C Ha l f W a l l 3' 2' Dog Wash 2'-10"5' 34'-1 1/2" 15'-8 1/2" 5'-6" 12'-11" 6 ' - 5 1 / 2 " Covered Porch 30 6 8 Covered Deck Covered Deck 2468 DW O/O Kitchen 17'-2" x 9'-6" 100 CFM 10' Flat Ceiling 9'3'-1" 4' 3'- 6 " Pantry 3'-1" Ref 1 5 ° Duct Chase Va u l t Dn Higher Headers Uncovered Deck 6'6'19'-6"11'-10" 6' 6' 11'-10"28'19'-6" 13'-6"13'-3"13'-3"13'-6" 12-18-18 PE R M I T S E T 01-16-19 8'-3"6'-1"2'-6"2'-6"3'-11"3'-9" 1'-10" 4'-6"2'-6"6'-4"6'-6" 4'-10"12'-10"7'7'-8"5'14'-4" 11 ' - 8 " 2'- 4 " 16 ' 3' 10 ' - 2 " 2'- 1 0 " 5'-5"6'-5"1'-10"9'-6"2'-4" 11'-10"13'-8" 3'- 3 " 3'- 9 " 3'-3"4'-9"4'-9"3'-3" 3'- 9 " 5'- 3 " 9' 2'-1"5'-1"3'-8"5'2' 10'-10"7' 4'- 2 " 5'- 6 " 5'- 4 " 4'- 2 " 6'- 6 " 5'- 7 " 3'- 6 " 4'- 1 1 " 9' Flat 9' Flat 2'- 1 " 3'- 6 " La d d e r U p T o Re a d i n g N o o k A b o v e 10'-6"3'-2"5'-10"6'-6" 2'- 8 1 / 2 " 3'- 3 1 / 2 " 2'-0 1/2" 2'-4" 10 ' - 2 " 1'- 6 " P F H P F H P F H P F H P F H 2'- 4 " 13 ' 3050 SH Temp 10'12'12'10' 6x6 P o s t (5 T y p ) 4-2 S t o r y 6x 6 P o s t s 5-1 1 / 2 S t o r y 6x 6 P o s t s SCM IB W P 5 IB W P 5 IBWP 5 03-04-19 Cross Section Foundation Wall System: G Floor System: Interior Walls: Exterior Walls: Soffit System: A C E D B Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 15 23 12 12 17 12 12 16 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2015 IRC Code Section R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Carbon Monoxide Alarms 2015 IRC Section R315 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fasteners for Preservative treated wood 2015 IRC Code Section R402.1.1 Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasteners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the front line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2015 IRC Section R408 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. CM Window Well System: 2015 IRC Code R301.1 ASTM F 2090 Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. R310.2.3.1 Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. If basement is a habitable space with NO Bedrooms then a window well with egress will need to be provided J Basement Furring: F 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Not Required #6 at 35" O.C. #6 at 34" O.C. Max. Wall Height 8' 9' 10' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' 7' or less 8' 9' 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8' and Greater (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 Cross Section Roof System: 2015 IRC Code Section R801, R901 Architectural Grade, 25 year Asphalt Shingles R905 over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 6:12 & 3:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2015 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall A E D B 12 21 32 12 16 24 12 12 16 12 12 12 S C Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e A4 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO 10-31-18 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 9 Copyright Sundance Drafting and Design 2019 Copyright Sundance Drafting and Design 2019 1/8"=1'-0" UNO Start Date Permit SetBid Set TOTAL SQ. FTG.= 3462 MAIN FLOOR=1680/1600 INTERIOR BASEMENT=1782 GARAGE=1091 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 4'Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r IBWP 3 Interior Braced Wall Panel IBWP 2012 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSBNailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 51/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blockedScrewed @7"/7" w/1" Drywall ScrewsAll Vert Joints occur over studAll Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. Rev Rev A5 of THRU J O I S T & P O S T P.T. BLOCKING 2X4 P.T. S P A C E D D E C K I N G POST C A P P E R P L A N P.T. D E C K J O I S T P E R P L A N CARRA G E B O L T S 2X P.T. (2) 1/2"x 5 1 / 2 " AN CONNECTIONPER PLAN PER PLANP.T. BEAM P.T. POST OR WALL Deck Detail 2X6 P.T. T O P R A I L @ 5 3/8"O.C .2X2 P.T. P I C K E T S 1X4 P.T. E A C H S I D E 4X4 P.T. P O S T36 " M I N . 4" MA X . THROUGH P.T. LEDGER INTO RIM JST. @ 16" O.C. 5/8"x5" LAG SCREWS 1X4 P.T. E A C H S I D E Header to jack-stud strap per table R602.10.6.4 on both sides of opening opposite side of sheathing Fasten sheathing to header w 8d common or gal. box nails in 3" grid pattern as shown Min. Length of panel per Table R602.10.5 (1) 58" Ø Anchor Bolts R403.1.6 with 2"x2"x316" plate washer Min. double 2x4 framing covered w min. 716" thick wood structualpanel sheathing w 8d common or gal. box nails at 3" o.c. in framing (studs and sills) as shown. typ. Min. (2) 3500 LB Tie-Down Device (Embedded into Concrete and Nailed into Framing) Min. Double 2x4 Post 1800 3000 Note a MIN. WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS Table R602.10.6.1 Tie-Down Force (lb.) - - If needed, panel splice edges shall occur over & be nailed to common blocking w/in middle 24" of wall mid-height. One row of 3" o.c. nailing is req. in ea. panel edge Typical Portal Frame Construction Ma x H e i g h t 1 0 ' - 0 " Min. 1000LB Tie down Device Double Portal Frame (Two Braced Wall Panels) Single Portal Frame (One Braced Wall Panel) 8 ft. 2'-4" 11 ft. 3'-2" SDC A,B, and C Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 SDC D,D, and D Windspeed <110 MPH Extent of Header 2200 3600 Extent of Header Seismic Design Category and Windspeed 10 ft. 2'-8" 0 1 2'-8"2'-8" 9 ft. 2'-8" 2'-8" 12 ft. 3'-6" 1800 3000 Sheathed Width 1800 3000 2000 3300 R602.10.6.1, Item 1 R602.10.6.1, Item 2 Sheathed Width 1800 30002 Note a - - Alternate Braced Wall Panel Garage Portal Design Height of Braced Wall Panel Figure R602.10.6.2 Min. 3"x11 14" net header (Steel header prohibited) Ma x T o t a l W a l l H e i g h t 1 2 ' - 0 " Min. reinforcing of foundation, (1) #4 bar top & bottom of footing. Lap bars 15" min. Table R602.10.5 MIN. LENGTH OF BRACED WALL PANELS Min. Footing under opening is 12"x12" 2'-18" finished width for single or double portal Wall height 8ft 9ft 10ft CS - P F 16" 18" 20" Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Rev Portal Frames with Hold Downs (PFH) Ha y e s R e d s i d e n c e 2015 IRC Code R602, R608, R703 Vinyl Siding and Faux Stone over Weather Resistive Barrier 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field 2x6 Stud framed @ 24" O.C. UNO with (2) 2x6 Top Plates with (1) 2x6 Bottom Plate with min. R-21 Batt Insulation with 1/2" Sheetrock Inside Occupancy separation between between house, attic, and garage Taped Prep'd for Interior Finishes 2015 IRC Code 2x6 Fascia Board with style "D" Metal Drip Edge with 3/8" Soffit Sheeting with 3" Continuous Soffit Venting with add'l 2x4 Support as Required 2015 IRC Code 2x4 Stud framed @ 24" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides Taped Prep'd for Interior Finishes 2015 IRC Code Section R502, R503, R504 3/4" T&G OSB Sub-floor Glued & Nailed over 11-7/8 TJI Engineered Floor Joist Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) connected to Rim Joist, spliced using gal. metal ties not less than .058" x 1.5" wide fastened w/6 16d nails ea. side over 1/2" Sheetrock on Ceiling Side Taped and Prep'd for Interior Finishes 2015 IRC Code SectionR602.4 2x4 Stud Framed @ 24" O.C. with Bearing Walls @ 16" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with R-13 Batt Insulation with 6-Mill Poly Vapor Barrier with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes 2x6 Treated Sill Plate over Foam Sill Sealer with 1/2" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/nut & ROUND Plate Washer 2 1/2Ø x1/4" Min. for ea. Bolt over Concrete Foundation Wall Consistent w/2015 IRC R608 with Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/2012 IRC Section R106.1 over Undisturbed Soil Stair System: 2015 IRC R302.7, 311.7.2, R311.7 R312.1.3 Eq. Stair Risers 7 3/4" Max. height, Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers bolted at bottom with P.T. 2x4 -3 places with 3" x 12" Ø bolt and top securely mounted to framing with Simpson A35 Connector at Stairs Stringer to Ledger or alternate approved connection. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 12" Gypsum Board under stairs 2% Slope Max 1 to 48 H 12-18-18 PE R M I T S E T 01-16-19 (2) #4 Rebar Horiz. Cont. 5" FG 8'-1" to 9' (1) Horiz. Bar in top 12" and one bar at each third point Beam to be Sized by Expert Great RoomEntryFront Porch Back Deck Family Room 8'- 1 1 " 10 ' 1'- 2 " 9' 8" 18 ' - 1 1 " 20 ' - 1 " 29 ' - 1 " 29 ' - 9 " 31 ' - 6 1 / 2 " 32 ' - 3 " 8" 3'- 6 " 12 ' AA BB CC EE 11" Min Run on Conc. Step into house Max Rise 7 3/4" Concrete Steps into House 12 6 6'- 8 " 3' 3 6 ° H Head r o o m H e i g h t Hand r a i l H e i g h t 10" 7 3 / 8 " DD 03-04-19 Plot Plan Scale: 1/8" =1'-0" D Size Paper Scale: 1/16"=1'-0" B Size Paper 905 Twin Butte Rd. Jefferson County, Idaho NORTH A5 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO 10-31-18 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 9 Copyright Sundance Drafting and Design 2019 Copyright Sundance Drafting and Design 2019 1/8"=1'-0" UNO Start Date Permit SetBid Set TOTAL SQ. FTG.= 3462 MAIN FLOOR=1680/1600 INTERIOR BASEMENT=1782 GARAGE=1091 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Rev Ha y e s R e d s i d e n c e 12-18-18 PE R M I T S E T 01-16-19 2 5 ' - 6 " 1 6 ' 1 7 ' - 1 0 " 3 4 ' - 7 1 / 2 " 9 3 ' - 1 1 1 / 2 " 7'30' 8'45' 5 3 ' - 6 " 5 ' - 1 0 " 5 9 ' - 4 " 2 6 ' - 6 " 6' 3 4 ' - 7 1 / 2 " 9 3 ' - 1 1 1 / 2 " 23' 12' 35' 33'-4 1/2" 11'-7 1/2" 45' 15'-4"12'-8" C O U N T Y R O A D R O W POB S 2 ° E 3 5 7 . 8 7 ' EAST 605.18' N 3 5 ° 2 8 ' W 4 4 8 . 3 1 ' WEST 99.0'S 85°40'56" W 99.31' WEST 159.52' POB 10 4 ' - 2 " 1 0 4 ' - 2 " Loca t i o n of N e w Cons t r u c t i o n (See A2 for exact dimensions) Private Drive 200'-10" 10 0 ' - 5 " 30 ' 03-04-19 S e p t i c D r a i n f i e l d R e p l a c e m e n t Well 10 0 ' M i n B e t w e e n S e p t i c & w e l l 03-12-19