SOLAR PANEL INFO & PLANS - 19-00786 - 369 W 3rd S - Solar Panels
CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT PROJECT INFORMATION, VICINITY MAP www.bigdogenergy.com P V - 1 12/23/2019 ALL CONDUIT TO RUN ON EXTERIOROF HOUSE UNLESS OTHERWISE NOTEDOCCUPANCY:R-3CONSTRUCTION TYPE:VBUNSPRINKLEREDALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH THECODE AND THE MANUFACTURES INSTALLATION INSTRUCTIONS.ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THE PLACARD.LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC2017 CODE. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED. ALL PLUMBING ANDMECHANICAL ROOF VENTS TO CLEAR FROM PHOTOVOLTAICARRAY, OR EXTEND ABOVE SOLAR PANELS. SOLARPHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIALSTRUCTURE. DESIGN COMPLYING WITH THE IBC 2015 CODEAND ALL LOCAL ORDINANCES AND POLICIES. THE PROJECT HASBEEN DESIGNED TO WITHSTAND A MINIMUM 110 MPH WINDLOAD. THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITY ISOBTAINED. IF THE MAIN SERVICE PANEL DOES NOT HAVEVERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE. EACH MODULE WILL BE GROUNDED USING THESUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULEAND THE MANUFACTURERS INSTALLATION INSTRUCTIONS. ALADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCEWITH OSHA REGULATIONS. PROPER ACCESS AND WORKINGCLEARANCE WILL BE PROVIDED "WARNING: PV POWERSOURCE" TO BE PLACED EVERY 10 FT.RAPID SHUTDOWN NOT REQUIRED. DC IS LESS THAN 5' INSIDEBUILDING.GFCI PROTECTION IN INVERTER.MSPSUBACDCSLCMINVJBCBFMC M A I N S E R V I C E P A N E L S U B S E R V I C E P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X F L E X I B L E M E T A L L I C C O N D U I T ( E ) ( N ) E X T I N T E M T R M T V O C V M P I S C N T S E X I S T I N G N E W E X T E R I O R I N T E R I O R E L E C T R I C A L M E T A L L I C T U B I N G R I G I D M E T A L L I C T U B I N G V O L T A G E O P E N C I R C U I T V O L T A G E A T M A X . P O W E R S H O R T C I R C U I T C U R R E N T N O T T O S C A L E I M P C U R R E N T A T M A X . P O W E R A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C 2 0 1 5 C O D E P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E ADDITIONAL NOTES P L A N S E T L E G E N D A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N V I C I N I T Y M A P A P P L I C A B L E C O D E S S H E E T I N D E X 8 X 3 1 0 W T R I N A P H O T O V O L T A I C M O D U L E S 1 X 3 8 0 0 W S O L A R E D G E S Y S T E M S I Z E : 2 , 4 8 0 W D C S T C A R R A Y A R E A : 1 3 6 S F B L A K E W I L L I S 2 6 9 W 3 R D S R E X B U R G , I D 8 3 4 4 0 2 0 8 - 7 0 9 - 8 0 6 1 BLAKE WILLIS 269 W 3RD S REXBURG, ID 83440 208-709-8061 Big Dog Renewable Electric Energy Contractor Lic # 017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ N M T R M S P I N V A C S U B CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SITE PLAN, AERIAL VIEW www.bigdogenergy.com P V - 2 SITE PLAN A E R I A L V I E W S C A L E : N T S S C A L E : 1 " = 3 0 ' - 0 " TOTAL # OF PANELS8 A B B R E V I A T I O N S I N V M S P A C I N V E R T E R M A I N S E R V I C E P A N E L A C D I S C O N N E C T M T R M E T E R Big Dog Renewable Electric Energy Contractor Lic # 017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 12/23/2019 BLAKE WILLIS 269 W 3RD S REXBURG, ID 83440 208-709-8061 S U B S U B P A N E L M O D U L E : T R I N A 3 1 0 W V o c = 4 0 . 2 V I s c = 9 . 9 4 A V m p = 3 3 . 2 V I m p = 9 . 3 7 A A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . T E R M I N A L S O F T H E D I S C O N N E C T I N G M E A N S M A Y B E E N E R G I Z E D I N T H E O P E N P O S I T I O N . C E C A R T I C L E 6 9 0 . 1 7 ELECTRICAL E Q U I P M E N T C A L L O U T S SOLADECK M O D E L 0 7 8 3 - 4 1 J U N C T I O N B O X / R O O F PENETRATIO N , 6 0 0 V 3.8.kW INVER T E R U N G R O U N D E D SOLAREDGE S E 3 8 0 0 H - U S (240V) INVER T E R 240VAC, 16A, N E M A 3 R , U L L I S T E D , (W/ INTEGRAT E D D C D I S C O N N E C T ) WITH INTEGR A T E D G F P , W / I N T E G R A T E D A F P 100A MAIN SE R V I C E P A N E L , (W/ BIDIRECTI O N A L U T I L I T Y M E T E R ) SOLAREDGE O P T I M I Z E R P 3 2 0 O N E P E R P A N E L AC DISCONN E C T 240VAC, 30A F U S E D N E M A 3 R , U L L I S T E D W / 2 0 A FUSESEXISTING 100 A S U B P A N E L I N H O U S E F E E D I N G HOUSE LOAD S 123 B 2,480W TOTAL SOLAR ARRAY8 TRINA 310W MODULESARRAY 18 MODULES CONNECTED IN 8 MODULE SERIES @ INVERTERCDA_~B 2 8 M O D U L E S I N S E R I E S 1 NNG C D MPP T 2 S T R I N G 1 T I L T : 2 2 ° A Z I M U T H : 1 8 0 ° 100A O N E P E R P A N E L A 3 WIRE AND CONDUIT CALLOUTS(2) #10 AWG PV/RHW-2 IN FREE AIR(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 34" EMT/FMC(2) #12 AWG THWN-2(1) #12 AWG THWN-2 GND IN 34" EMT(3)#1 USE AU(1)#6 USE AU IN PVC EXISTINGENGNNGL1L2L1L23E20ANNG100A4FHOUSELOADS26.4F3' OR LESS ELECTRICAL SINGLE LINE DIAGRAM CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SINGLE LINE DIAGRAM P V - 3 S C A L E : N T S E L E C T R I C A L N O T E S R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) www.bigdogenergy.com Big Dog Renewable Electric Energy Contractor Lic # 017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 12/23/2019 BLAKE WILLIS 269 W 3RD S REXBURG, ID 83440 208-709-8061 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 4 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT REQUIRED SIGNAGE www.bigdogenergy.com P V - 4 REQUIRED SIGNAGE1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 14"HIGH LETTERING PER NEC 690-17.2. LABEL FOR SOLAR AC DISCONNECT:FIRE DEPARTMENT REQUIRED SIGNAGE3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 38" HIGHLETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS,WHITE ON RED BACKGROUND AND A REFLECTIVE, WEATHERRESISTANT MATERIAL.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING:WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALS ONBOTH THE LINE AND LOAD SIDES MAY BEENERGIZED IN THE OPEN POSITION."SOLAR AC DISCONNECT" 6 . R E F L E C T I V E P L A C A R D A T S E R V I C E S T A T I N G : 7 . A T S E R V I C E D I S C O N N E C T : P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N R A P I D S H U T D O W N D I S C O N N E C T 12/23/2019 BLAKE WILLIS 269 W 3RD S REXBURG, ID 83440 208-709-8061 Big Dog Renewable Electric Energy Contractor Lic # 017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRIDAND PV SOLAR ELECTRIC SYSTEMTHE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THEMAIN SERVICE DISCONNECT IS OPERABLE WITH THE SERVICEPANEL CLOSED.4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY ACDISCONNECT:CUSTOMER OWNEDONSITE POWER GENERATIONSYSTEM DISCONNECT5. LABEL INSTALLATION AT INTERCONNECT BREAKER:WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE. Great aesthetics for dark roofs • Dark mono cells• Black frame and backsheet Maximize Limited Space with high efficiency • Up to 189 W/m² power density• Low thermal coefficients for greater energy production at high operating temperatures Excellent low light performance on cloudy days, mornings and evenings • Advanced surface texturing• Back surface field• Selective emitter Mono Multi Solutions 18,9% MAXIMUM EFFICIENCY 0/+5W POSITIVE POWER TOLERANCE 275–310W POWER OUTPUT RANGE 60 CELL MONOCRYSTALLINE MODULE Highly reliable due to stringent quality control • All modules have to pass electroluminescence (EL) inspection• Over 30 in-house tests (UV, TC, HF, and many more)• In-house testing goes well beyond certification requirements• PID resistant • 1000 V UL/1000 V IEC certified Certified to withstand challenging environmental conditions • 2400 Pa wind load• 5400 Pa snow load• 35 mm hail stones at 97 km/h• Ammonia resistance • Salt mist resistance • Resistance to sand and dust abrasion Industry standardTrina standard Additional valu e f r o m T r i n a S o l a r ’ s l i n e a r w a r r a n t y Gu a r a n t e e d P o w e r 80% 90% 100%97% Years 5 10 15 20 25 LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty · 25 Year Linear Power Warranty TSM-DD05A.05 (II) MODULE IN BLACK Founded in 1997, Trina Solar is the world’s leading comprehensive solutions provider for solar energy. We believe close cooperation with our partners is critical to success. Trina Solar now distributes its PV products to over 60 countries all over the world. Trina Solar is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina Solar as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distribu tors and other partners. Comprehensive Product And System Certificates IEC61215/IEC61730/UL1703/IEC61701/IEC62716ISO 9001: Quality Management SystemISO 14001: Environmental Management SystemISO14064: Greenhouse Gas Emissions VerificationOHSAS 18001: Occupational Health and Safety Management System EU-28 WEEECOMPLIANTRECYCLABLEPACKAGING TO P PERFORMER PV MODULE RELIABILITY SCORECARD 2017 TS M _ E N _ 2 0 1 7 _ B CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. © 2017 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to change without notice. www.trinasolar.com DIMENSIONS OF PV MODULE TSM-DD05A.05 (II) (unit: mm) ELECTRICAL DATA @ STC TSM-275 TSM-280 TSM-285 TSM-290 TSM-295 TSM-300 TSM-305 TSM-310 Peak Power Watts-PMAX (Wp)*275 280 285 290 295 300 305 310 Power Output Tolerance-PMAX (W)0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 Maximum Power Voltage-VMPP (V)31,4 31,7 31,8 32,2 32,5 32,6 32,9 33,2 Maximum Power Current-IMPP (A)8,76 8,84 8,97 9,01 9,08 9,19 9,28 9,37 Open Circuit Voltage-VOC (V)38,4 38,4 38,5 38,9 39,6 39,8 40,0 40,2 Short Circuit Current-ISC (A)9,24 9,42 9,51 9,66 9,68 9,77 9,85 9,94 Module Efficiency ηm (%)16,8 17,1 17,4 17,7 18,0 18,3 18,6 18,9 STC: Irradiance 1000 W/m², Cell Temperature 25 °C, Air Mass AM1.5* Measuring tolerance: ±3% ELECTRICAL DATA @ NOCT TSM-275 TSM-280 TSM-285 TSM-290 TSM-295 TSM-300 TSM-305 TSM-310 Maximum Power-PMAX (Wp)205 209 212 216 220 223 227 231 Maximum Power Voltage-UMPP (V)29,1 29,4 29,5 29,9 30,1 30,2 30,5 30,8 Maximum Power Current-IMPP (A)7,04 7,10 7,21 7,24 7,30 7,38 7,46 7,53 Open Circuit Voltage-UOC (V)35,7 35,7 35,8 36,2 36,8 37,0 37,2 37,4 Short Circuit Current-ISC (A)7,46 7,61 7,68 7,80 7,82 7,89 7,95 8,03 NOCT: Irradiance at 800 W/m², Ambient Temperature 20 °C, Wind Speed 1 m/s. TEMPERATURE RATINGS Nominal Operating CellTemperature (NOCT)44°C (±2K) Temperature Coefficient of PMAX - 0,39%/K Temperature Coefficient of VOC - 0,29%/K Temperature Coefficient of ISC 0,05%/K MAXIMUM RATINGS Operational Temperature -40 to +85°C Maximum System Voltage 1000 V DC (IEC)1000 V DC (UL) Max Series Fuse Rating*15 A (Power ≤ 285 W)20 A (Power ≥ 290 W) Mechanical Load 5400 Pa Wind Load 2400 Pa * DO NOT connect fuse in combiner box with two or more strings in parallel connection WARRANTY 10 year Product Workmanship Warranty 25 year Linear Performance Warranty (Please refer to product warranty for details) MECHANICAL DATA Solar Cells Monocrystalline 156,75 × 156,75 mm Cell Orientation 60 cells (6 x 10) Module Dimensions 1650 × 992 × 35 mm Weight 18,6 kg Glass 3,2 mm, high transparency, AR coated and heat tempered solar glass Backsheet Black Frame Black Anodized Aluminium Alloy J-Box IP 67 or IP 68 rated Cables Photovoltaic Technology Cable 4,0mm², 1000 mm Connector EU Countries: 28 MC4 / UTX / TS4, Non-EU Countries: 28 QC4 / TS4 TSM-DD05A.05 (II) PACKAGING CONFIGURATION Modules per box:30 pieces Modules per 40’ container:840 pieces I-V CURVES OF PV MODULE (295W) P-V CURVES OF PV MODULE (295W) 0 1 2 3 4 5 6 7 8 9 10 Cu r r e n t ( A ) Voltage (V) I-V Curves of TSM-295DD05A.08(II) at Various Solar Irradiances AM1.5, Cell Temperature: 25 0 50 100 150 200 250 300 Po w e r ʢ W ʣ Voltage (V) P-V Curves of TSM-295DD05A.08(II) at Various Solar Irradiances AM1.5, Cell Temperature:25 0 1 2 3 4 5 6 7 8 9 10 Cu r r e n t ( A ) Voltage (V) I-V Curves of TSM-295DD05A.08(II) at Various Solar Irradiances AM1.5, Cell Temperature: 25 0 50 100 150 200 250 300 Po w e r ʢ W ʣ Voltage (V) P-V Curves of TSM-295DD05A.08(II) at Various Solar Irradiances AM1.5, Cell Temperature:25 IN BLACK 992 16 5 0 A 947 1 8 0 1 5 0 9 9 0 3 3 0 1 0 0 0 ± 1 0 A 35 35 35 11 (A-A) Frame Laminate Silicon Sealant 12-Drain Hole 4-0 9x14Installing Hole Nameplate Junction Box 6-0 4.3Grounding Hole Back View IN V E R T E R S www.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-3 -3 ---Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V -16 -24 ---A Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 AUtility Monitoring, Islanding Protection, C o u nt r y C o nfi g u ra b l e T h r e s h o l d s Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --- Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V -9 -13.5 --- Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 WADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C option)(4)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. PO W E R O P T I M I Z E R SolarEdge Power Optimizer Module Add-On For North America P320 / P370 / P400 / P405 / P505 Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY- SWEDEN-SOUTH AFRICA-POLAND-CZECH REPUBLIC OPTIMIZER MODEL (typical module compatibility) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) P505 (for highercurrent modules) INPUT Rated Input DC Power(1)320 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125 83 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)128 x 152 x 28 / 5 x 5.97 x 1.1 128 x 152 x 36 / 5 x 5.97 x 1.42 128 x 152 x 50 / 5 x 5.97 x 1.96 128 x 152 x 59 / 5 x 5.97 x 2.32 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(2) Output Wire Type / Connector Double Insulated; MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge SolarEdge Power Optimizer Module Add-On for North America P320 / P370 / P400 / P405 / P505 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(3)(4) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) P320, P370, P400 8 10 18 P405 / P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50(5) Maximum Power per String 5700 (6000 with SE7600H-US, SE10000H-US) 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2018/V01/ENG NAM. Subject to change without notice. (3) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf.(4) It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 in one string.(5) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement Installation Manual For SolaDeck Models 0783-41 and 0786-41 Table of Contents: Warranty ………………………………………………………………………..2 SolaDeck Mounting instructions ……………………………………………..3 Safety Instructions, General Wiring…………………………………………..4 Requirements …………………………………………………………………..5 SolaDeck Features …………………………………………………………….6 Base Centering dimples……………………………….……………………….7 Base Plate Configuration ……………………………………………………...7 Fuse Holder and Bus …..…..………….……………………………………....8 Installed Equipment Examples 0783-41 & 0786-41……………..……………9 PV Panel Wiring Example……………………………………………………10 First Edition - February 2009 RSTC Enterprises Inc 2219 Heimstead Road Eau Claire, Wi 54703 866-367-7782 1 Warranty Information: Thank you for your purchase. As with all manufactured devices repairs may be needed due to damage, unauthorized use, or defect. •Warranty repairs must conform to warranty terms. •Equipment must be installed according to the instructions and manuals provided. •Products returned, must be Packaged, properly addressed and shipped prepaid. •There is no additional allowance or reimbursement for installer or user labor or travel time required to disconnect, service or reinstall the damaged component(s). •RSTC will ship a replacement product prepaid to addresses in the continental United States. •In the event of a product malfunction, RSTC will not bear any responsibility for resulting losses, expenses, or damage to other components. DO NOT PROCEED WITH INSTALLATION UNTIL YOU HAVE READ ENTIRE INSTRUCTIONS INCLUDING WARNINGS 2 One Year Limited Warranty Important: Evidence of original purchase is required for warranty service. WARRANTOR: RSTC Enterprises Incorporated ELEMENTS OF WARRANTY: RSTC warrants for one year to the original retail owner, this SolaDeck is free from defects in materials and craftsmanship with only the limitations or exclusions set out below. WHAT IS NOT COVERED: This warranty covers only defects in materials and workmanship provided by RSTC Enterprises, and does not cover equipment damage or malfunction from misuse, abuse, accident, and act of God. Installation must be in accordance with our written instructions. RSTC Enterprises will not be liable for any installation charges associated with replacement , incidental or consequential damages resulting from your use of or inability to use the SolaDeck. REMEDY: Your only remedy under this warranty is the exchange or replacement in the event that the product does not conform to this warranty. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. CLAIMS PROCESS: To make a claim under this warranty, the product should be shipped postage paid, with original purchase receipt to: RSTC ENTERPRISES 2219 HEIMSTEAD ROAD EAU CLAIRE, WI 54703 1-866-367-7782 or www.commdeck.com m po WARNING! STOP DO NOT WORK ON ROOF IF SURFACE IS WET, FROSTED, ICE OR SNOW COVERED. USE LADDERS SAFELY USE HAND & EYE PROTECTION WHEN WORKING WITH POWER TOOLS USE EXTREME CAUTION TO AVOID CONTACT WITH POWER LINES. CONTACT WITH POWER LINES, ELECTRIC LIGHTS OR POWER CIRCUITS MAY BE FATAL Installation of this product should be attempted only by individuals skilled in the use of the tools and equipment necessary for installation. Protect you and all persons and property during installation. If you have any doubt concerning your competence or expertise, consult a qualified expert to perform the installation. R.S.T.C. Enterprises Incorporated assumes no responsibility for the failure of an architect, contractor, installer, or building owner to comply with all applicable laws, building codes and requirements, and adequate safety precautions. Tools and Hardware List Utility Knife - #2 Phillips Head Driver Bit- Pry Bar – Roof sealant – Cordless Drill A – (7) # 10 – 1” Phillips head wood screws D – (2) 10-32 – ½” Steel studs B – (4) 8-32 – ½” Phillips head threading machine screws E – (2) # 10 Star washers C – (4) #10 Bonded seal washers F – (2) 10-32 – 3/8” steel nuts 3 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS- This manual contains important instructions for models 0783- 41 and 0786-41that shall be followed during installation of the combiner. SolaDeck models are listed by ETL as PV Combiners under the standard: UL 1741, First Edition SolaDeck models meet UL 50 Type 3R rainproof requirements. This enclosure is rated for up to 600 VDC fuses. Grounding Instructions- Each system should be connected to a grounded, permanent wiring system. All system wiring and system grounding must comply with NEC Code, ANSI/NFPA 70-1996, or other appropriate codes, is the responsibility of the installer. The equipment ground on SolaDeck is marked with the symbol: Note: Solar panels produce electrical current when lighting is present, even during overcast weather. Do not wire from the array to the SolaDeck combiner. Complete all connections inside the SolaDeck combiner first and then connect the array. General Wiring Installation Instructions •Remove any necessary knockouts before securing the SolaDeck to the roof or other surface. •Follow the mounting instructions page 3 •Slide the fuse holders onto the Din rail and lock in place. •Secure the Bus Bar to the fuse holders. •Install the negative power distribution block using the steel studs in the location designated for the Negative PV Model (0783). •Install negative terminal blocks on DIN rail where designated PV Negative and lock in place. Model (0786). •Connect all wires to fuse holders, bus bar lug and negative terminals, securing them according to the listed torque values from table on page 5. •Conduit and Strain relief fittings and hubs must comply with UL 514B 4 Requirements •Use minimum 75 C copper •Use only code approved, appropriately listed fuse holders and Fuses Maximum Fuse Rating 30 AMP , 600 Volt Total Maximum Current Rating 0783-41 / 0786-41 120 AMPS DC Maximum Fuse Short Circuit Current 10ka Fuse Holder Torque 13.6 in lb Flat or Phillips Head Driver Din Rail Mounted Terminal Block Torque 9 - 14 in lb Flat Head Driver Torque Data* for Box Lug Wire Size Torque AWG mm2 in lbs Nm 14-10 2.1-5.3 35 4 8 8.4 40 4.5 6-4 13.3-21.2 45 5.1 2 13.3-21.2 50 5.7 Torque Data* for Negative Power Distribution Block Wire Size Torque Screw Driver External Drive Wrench AWG mm2 in lbs Nm 14-10 2.1-5.3 35 75 4 8 8.4 40 75 4.5 6-4 13.3-21.2 45 110 5.1 Main 2/0-14 13.3-21.2 0 120 5.7 Torque Data* for Ground Lug Wire Size Torque AWG mm2 in lbs Nm 14-10 2.1-5.3 35 4 8 8.4 40 4.5 6-4 13.3-21.2 45 5.1 2-2/0 13.3-21.2 50 5.7 5 SolaDeck Combiner Features •Stamped Seamless Galvanized Steel •Powder Coated Surfaces •Mounting Hardware Included •Flashes into the roof deck •6” DIN rail installed Model (0786) •3” DIN rail installed Model (0783) •2 Position Ground lug installed •3 Roof deck knockouts .5”, .75”, 1” •5 Centering dimples for enter/exit strain or conduit fittings •Accommodates fuse holders with combiner bus SolaDeck cover on base Fig 1 Four 8-32 3/8” phillips head self thread screws and boded seal washers secure the SolaDeck cover Figure 1 6 SolaDeck Base showing dimples Fig 2 Corner dimples support .5” or .75” fittings or conduit Center dimples support .5” fittings or conduit Figure 2 Base plate configuration Fig 3 Three knockouts for roof deck penetration .5”, .75”, 1” 7 Figure 3 Fuse holders with bus Bar Fig 4 Figure 4 8 SolaDeck Models with cover off Model 0786-41 9 Model 0783-41 PV Panel Example 10 3-2 © 2007 Schneider Electric All Rights Reserved www.schneider-electric.us 3 S A F E T Y S W I T C H E S General Duty Safety Switches Light Duty Class 3130 General Duty—Up To 100 kA Short Circuit Current Rating With Proper Current Limiting Fusing General duty safety switches are designed for residential and commercial applications where economy is a prime consideration. Typical loads are lighting, air conditioning, and appliances. They are suitable for use as service equipment when equipped with a factory-installed neutral assembly or a field-installed service grounding kit. General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1. 400 and 600 A general duty switches (NEMA 1 only) will accept Class J fuses and are UL Listed for use on systems with up to 100 kA available fault current. 600 A requires Class J fuse kit—GDJK600 (page 3-3). 400 A requires moving load base. Class T 400–800 A general duty safety switches use 300 Vac Class T fuses and are UL Listed for use on systems with up to 100 kA available fault current. a Bolt-on hubs—Refer to page 3-9. b When installed, this kit rejects all but Class R fuses. When installed with this kit and Class R fuses, the switch is UL Listed for use on systems with up to 100 kA available fault current. c For corner grounded delta systems only. Use switching poles for ungrounded conductors. d If corner grounded delta, use outer switching poles for ungrounded conductors. e For 200% neutral, order (1) additional neutral kit SN20A at $133. and (1) neutral jumper kit SN20NI at $18.40. f Bolt-on hubs—Refer to page 3-9. g Enclosed molded case switch—Refer to 1-22. h Includes factory-installed grounding kit. i Not service entrance rated—Refer to page 1-19 for more information. j Includes factory-installed neutral.For service equipment use or when neutral is required, order part number SN0610 at $71.00. k Suitable for use as service equipment, requires field installation of neutral assembly SN20A at $133.00. l If corner grounded delta, install neutral and use outer switching poles for ungrounded conductors. Light Duty—Visible Blades 10 kA Short Circuit Current Rating The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces and garages. m For single phase hp rating, use two switching poles. n DE1A Discount Schedule. UL Listed Short Circuit Withstand Rating Switch Type Fuse Class Short Circuit Rating Fusible Plug 10 kA H10 kA K10 kA J100 kA R100 kA T100 kA Non-Fusiblea H10 kA K10 kA J100 kA R100 kAb T100 kA a The UL Listed short-circuit current rating for Square D general duty, not fusible switches is based on the switch being used in conjunction with fuses. Evaluation of non-fusible switches in conjunction with molded case circuit breakers has not been performed. If a UL Listed short-circuit current rating is required, this non-fusible switch must be replaced with a Square D general duty fusible safety switch equipped with the appropriate class and size fusing. The UL Listed short-circuit current rating of the fusible switch is typically as follows: when used with Class H & K fuses—10,000 A, Class R and J fuses—100,000 A. Consult the wiring diagram of the switch to verify the UL Listed short-circuit current rating. b 50 kA for 60 A non-fusible switch. Table 3.1: Fusible System A Fuse NEMA 1 Indoor NEMA 3Ra Rainproof Class R Fuse Kits Field-Installableb Horsepower Ratings Std. (Fast Acting One-Time Fuses) Max. (Dual Element Time-Delay Fuses)Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 1Ø 3Ø 1Ø 3Ø 2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac 30 Plug Use Light Duty Device for This Application (see below) — — — — 30 Cart. Use 3 Wire Devices for this application. — — — — 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac (Plug), 240 Vac (Cart.) Maximum 30 Plug D211N 60.00 D211NRB 118.00 — — 1-1/2 — 3 — 30 Cart.D221N 81.00 D221NRB 125.00 DRK30 17.10 1-1/2 3c 37-1/2c 60 Cart.D222N 137.00 D222NRB 217.00 RFK03H 17.00 37-1/2c 10 15c 100 Cart.D223N 284.00 D223NRB 320.00 RFK10 31.80 7-1/2 15c 15 30c 200 Cart.D224Ne 589.00 D224NRBe 800.00 HRK1020 31.80 15 25c —60c 400 Cart.D225N 1703.00 D225NR 2306.00 DRK40 74.00 ———— 600 Cart.D226N 3406.00 D226NR 4379.00 DRK600 74.00 ———— 4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac Maximum 30 Cart.D321N 125.00 D321NRB 195.00 DRK30 17.10 1-1/2 3 3 7-1/2 60 Cart.D322N 217.00 D322NRB 294.00 RFK03H 17.00 37-1/2d10 15d 100 Cart.D323N 376.00 D323NRB 544.00 RFK10 31.80 7-1/2 15d 15 30d 200 Cart.D324Ne 801.00 D324NRBe 974.00 HRK1020 31.80 15 25d —60d 400 Cart.D325N 2075.00 D325NR 2595.00 DRK40 74.00 — 50 — 125 400 Class T D325NT 1996.00 D325NTR 2494.00 —— — 50 — — 600 Cart.D326N 3882.00 D326NR 5251.00 DRK600 74.00 — 75 — 150 600 Class T D326NT 3732.00 D326NTR 5046.00 —— — 75 — — 800 Class T T327N 6481.00 T327NR 8292.00 — — — 100 — — Table 3.2: Non-Fusible System A NEMA 1 Indoor NEMA 3R Rainproof f Horsepower Ratings (Max.) Cat. No. $ Price Cat. No. $ Price 1Ø 3Ø 2 Wire (2 Blades)—240 Vac Maximum 30 — —DU221RBk 118.00 3— 60 — —DU222RBk 235.00 10 — 60 QO260NATSgh 107.00 QO200TRghi 107.00 10 — 100 QO2000NSgh 184.00 QO2000NRBgi 225.00 20 — 200 Use 3P Switch — Use 3P Switch — — — 400 Use 3P Switch — Use 3P Switch — — — 600 Use 3P Switch — Use 3P Switch — — — 3 Wire (3 Blades)—240 Vac Maximum 30 DU321k 103.00 DU321RBk 195.00 37-1/2 60 DU322k 137.00 DU322RBk 295.00 10 15 100 DU323j 318.00 DU323RBj 544.00 15 30 200 DU324k 589.00 DU324RBk 974.00 15 60l 400 DU325k 1465.00 ———125 600 DU326l 2794.00 ———150 Table 3.3: Fusible System Rating (A)Fuse NEMA 1 Indoor Horsepower Ratings System A Fuse NEMA 1 Indoor Horsepower Ratings Cat. No. n $ Price Std. Max. Cat. No. n $ Price Std. Max. 2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac 30 Plug L111N $35.90 1/2 2 30 Plug L211N 47.80 1-1/2 m 3 m 30 Cart.L221N 65.00 1-1/2 m 3 mL211N DE1A DE2A Discount Schedule Modified4/16/09 www.schneider-electric.us 3 SA F E T Y S W I T C H E S © 2007 Schneider Electric All Rights Reserved 3-3 General Duty Safety Switches Accessories, Lug Data and Dimension Class 3130 Field-Installable Electrical Interlock Kits Electrical interlocks for Series F 100–200 A general duty safety switches and Series F 60 A fusible general duty safety switches are available in kit form for field installation. Each kit contains instructions for proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break. Switches with electrical interlocks installed are UL Listed. a Electrical interlock kit catalog numbers with -1 suffix indicates one normally open and one normally closed contact; -2 indicates two normally open and two normally closed contacts. Kits are UL Listed. Field-Installable Fuse Puller Kits Kit consists of three fuse pullers as required for a 3P, fusible, 60 and 100 A general duty switch. Kits can be installed in 60 and 100 A Series F switches. b 30–100 A switches suitable for 60oC or 75oC conductors. 200–800 A switches suitable for 75oC conductors. c 30–100 A switches suitable for 60oC or 75oC conductors. 200–800 A switches suitable for 75oC conductors. Table 3.4: Electrical Interlock Kit Switch Rating(A)Electrical Interlock KitCat. No.a $ Price Fusible Series F 60 EIK031 orEIK032 145.00 Series F 100–200 EIK1 orEIK2 207.00 Table 3.5: Field-Installable Class J Fuse Kit The kit consists of three Class J fuse adapters as required for a 3P, fusible 600 A general duty switch. Kit can be installed in 600 A series E3 switches only (NEMA 1). Switch Rating(A)Class J KitCat. No.$ Price 600 A Series E3 GDJK600 195.00 H DW/H W Description Cat. No. $ Price Series F 60 A Fuse Puller Kit FPK03 20.00 Series F 100 A Fuse Puller Kit FPK0610 28.40 Table 3.6: Field-Installable Service Grounding Kits Switch Rating (A) Cat. No. $ Price Wire Size (AWG) 30 PK3GTA1 7.60 (2) 12 Cu or (2) 10 Al or (1) 4 Al/Cu Max. Series E 60 PK3GTA1 7.60 (2) 12 Cu or (2) 10 Al or (1) 4 Al/Cu Max. Series F 60 GTK03 7.60 (2) 12 Cu or (2) 10 Al or (1) 4 Al/Cu Max. 100 GTK0610 12.60 (2) 1/0 Al/Cu Max. 200 PKOGTA2 36.80 (2) 2/0 Al/Cu Max. 400 PKOGTA2 36.80 (2) 2/0 Al/Cu Max. 600 (Two Required) Per Lug 800 PKOGTA3 82.00 (6) 3/0 Al/Cu Max. Table 3.7: Terminal Lug Datab Rating(A)ConductorsPer Phase Wire RangeWire Bending Space Per NEC Table 312.6AWG/kcmil Lug Wire RangeAWG/kcmil 30 1 12–6 (Al) or 14–6 (Cu) 12–6 (Al) or 14–6 (Cu) 60 1 10–3 (Al) or 14–3 (Cu) 10–2 (Al) or 14–2 (Cu) 100 1 12–1 (Al) or 14–1 (Cu) 12–1/0 (Al) or 14–1/0 (Cu) 200 1 6 –250 (Al/Cu) 6 –300 (Al/Cu) 400NEMA 1 1or2 1/0 –600 (Al/Cu)or 1/0 –300 (Al/Cu) (1) 1/0 –750 (Al/Cu)or(2) 1/0 –300 (Al/Cu) 400NEMA 3R 2 1/0–250 (Al/Cu) (1) 1 –600 (Al/Cu)or(2) 1/0 –250 (Al/Cu) 600 2 4 –500 (Al/Cu) 4 –600 (Al/Cu) 800 3 3/0 –500 (Al/Cu) 3/0 –500 (Al/Cu) Table 3.8: Field-Installable Lug Kit Kit consists of three line, three load, and two neutral lugs as required for a 3P 400 A or 600 A general duty switch. Kit can be installed on 400 or 600 A Series E3 switches. This kit applicable to NEMA 1 enclosures only. Switch Rating(A)Lug Kit Cat. No.Wire Range/NEC 312.6AWG/kcmil Lug Wire Range per LugAWG/kcmil $ Price 400 or 600 A Series E3 GD4060LK (1) 1/0–600 or(2) 1/0–500 or(4) 1/0–250 (2) 1/0–600 or(4) 1/0–250 269.00 Table 3.9: Approximate Dimensions Cat. No. Series HWW/HDStd.Pack Cat. No. Series HWW/HDStd.Packin. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm L111N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D325NTRc E1 30.63 778 21.38 543 22.25 565 10.13 257 1 L211N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D326Nc E3 49.13 1248 24.00 610 24.88 632 8.88 226 1 L221N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D326NTc E3 49.13 1248 24.00 610 24.88 632 8.88 226 1 D211Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 D326NRc E1 49.13 1248 24.75 629 25.13 638 8.88 226 1 D211NRBc E2 9.63 245 7.25 184 7.75 197 3.75 95 5 D326NTRc E1 49.13 1246 24.75 629 25.13 638 8.88 226 1 D221Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 DU221RBc E2 9.63 245 7.25 184 7.75 197 3.75 95 5 D221NRBc E3 9.63 245 7.25 184 7.75 197 3.75 95 5 DU222RBc E1 9.63 245 7.25 184 7.75 197 3.75 95 5 D222N F1 14.63 372 6.50 165 7.45 189 4.88 124 1 DU321c E2 9.25 235 6.75 171 7.25 184 3.63 92 5 D222NRB F1 14.88 378 6.63 168 7.45 189 4.88 124 1 DU321RBc E2 9.63 245 7.25 184 7.75 197 3.75 95 5 D223N F3 17.50 445 8.50 216 10.50 267 6.50 165 1 DU322c E1 9.25 235 6.75 171 7.25 184 3.63 92 5 D223NRB F3 17.50 445 8.50 216 10.50 267 6.50 165 1 DU322RBc E1 9.63 245 7.25 184 7.75 197 3.75 95 5 D224N F1 29.00 737 17.25 438 19.00 483 8.25 210 1 DU323 F3 17.50 445 8.50 216 10.50 267 6.50 165 1 D224NRB F1 29.25 743 17.25 438 19.00 483 8.25 210 1 DU323RB F3 17.50 445 8.50 216 10.50 267 6.50 165 1 D225N E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 DU324 F1 29.00 737 17.25 438 19.00 483 8.25 210 1 D225NR E1 30.63 778 21.38 543 22.25 565 10.13 257 1 DU324RB F1 29.25 743 17.25 438 19.00 483 8.25 210 1 D226Nc E3 49.13 1248 24.00 610 24.88 632 8.88 226 1 DU325c E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 D226NRc E1 49.13 1248 24.75 629 25.13 638 8.88 226 1 DU326c E3 49.13 1248 24.00 610 24.88 632 8.88 226 1 D321Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 QO200TRc G3 6.50 165 4.63 118 — — 3.88 99 5 D321NRBc E3 9.63 245 7.25 184 7.75 197 3.75 95 5 QO260NATSc E2 9.25 235 4.88 124 — — 3.25 83 1 D322N F1 14.63 372 6.50 165 7.45 189 4.88 124 1 QO2000NRBc E1 14.00 356 7.75 197 — — 4.50 114 1 D322NRB F1 14.88 378 6.63 168 7.45 189 4.88 124 1 QO2000NSc E1 13.38 340 6.13 156 — — 3.50 89 1 D323N F3 17.50 445 8.50 216 10.50 267 6.50 165 1 T327Nc E1 49.13 1248 24.00 610 24.88 632 8.88 226 1 D323NRB F3 17.50 445 8.50 216 10.50 267 6.50 165 1 T327NRc E1 49.13 1248 24.75 629 25.13 638 8.88 226 1 D324N F1 29.00 737 17.25 438 19.00 483 8.25 210 1 D325NTRc E1 30.63 778 21.38 543 22.25 565 10.13 257 1 D324NRB F1 29.25 743 17.25 438 19.00 483 8.25 210 1 D326Nc E3 49.13 1248 24.00 610 24.88 632 8.88 226 1 D325Nc E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 D326NTc E3 49.13 1248 24.00 610 24.88 632 8.88 226 1 D325NTc E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 D326NRc E1 49.13 1248 24.75 629 25.13 638 8.88 226 1 D325NRc E1 30.63 778 21.38 543 22.25 565 10.13 257 1 DE1 DE3A Discount Schedule www.schneider-electric.us 3 S A F E T Y S W I T C H E S 3-4 © 2007 Schneider Electric All Rights Reserved Heavy Duty Safety Switches 240 Volt Class 3110 Visible blade heavy duty safety switches are designed for application where maximum performance and continuity of service are required. All heavy duty safety switches feature quick-make, quick-break operating mechanism, a dual cover interlock and a color coded indicator handle. They are suitable for use as service equipment when equipped with a field- or factory-installed neutral assembly or equipment grounding kit, unless a 600Y/347 V or 480 Y/277 V, 1000 A or greater, solidly grounded WYE system is used, per NEC 215-10. Heavy duty safety switches are UL Listed (except as noted), File E2875 & 154828 and meet or exceed the NEMA Standard KS1. For UL Listed short circuit current ratings, see page 3-6. Dimensions: NEMA 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-12 Dimensions: NEMA 4, 4X and 5 Stainless and NEMA 12 . . . . . . .page 3-13 Accessories: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 3-9 through 3-11 NEMA 1 NEMA 3R NEMA 4, 4X and 5 Stainless Steel NEMA 12 Table 3.10: 240 Volt—Single Throw Fusible System Amperes NEMA 1Indoor NEMA 3RRainproof(Bolt-on Hubs,page 3-9) NEMA 4, 4X, 5, a304 Stainless Steel (for 316 stainless, seepage 3-7) Dust tight, Watertight, Corrosion Resistant (Watertight Hubs, page 3-9) NEMA 12KWithKnockouts(Watertight Hubs,page 3-9) NEMA12, 3R bWithoutKnockouts (Watertight Hubs, page 3-9) Horsepower Ratings c 240 Vac 250 Vdcd Std.(Using Fast Acting, One Time Fuses) Max.(Using Dual Element, Time Delay Fuses) Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 1Ø 3Ø 1Ø 3Ø 2 Wire (2 Blades and Fuseholders)—240 Vac, 250 Vdc 30 Use 3 Wire DevicesFor 2 Wire Applications H221DS 1298.00 H221A 336.00 H221AWK 315.00 1-1/2 3 e 37-1/2e 5 30 ————H2212AWKf 392.00 1-1/2 —3 —5 60 H222DS 1558.00 — —H222AWK 431.00 37-1/2e10 15 e 10 100 H223DS 3396.00 H223A 672.00 H223AWK 632.00 7-1/2 15 e 15 30 e 20 200 H224DS 4640.00 H224A 1158.00 H224AWK 1095.00 15 25 e —60 e 40 400 H225 1819.00 H225R 2589.00 H225DS 9654.00 — —H225AWK 2775.00 — — — —50 600 H226 3616.00 H226R 4854.00 H226DS 13848.00 — —H226AWK 4362.00 —75 e —200 e 50 800 H227 5639.00 H227Rg 7655.00 — — — —H227AWK 6883.00 50 —50 —50 1200 H228 7788.00 H228Rg 10324.00 — — — —H228AWK 10543.00 50 —50 —50 3 Wire (2 Blades and Fuseholders, 1 Neutral)—240 Vac, 250 Vdc 30 H221N 157.00 H221NRB 298.00 Use 2 Wire Devices,Field-Installable Solid Neutral AssembliesOrder Separately See page 3-10. 1-1/2 3 e 37-1/2 e 5 60 H222N 314.00 H222NRB 561.00 37-1/2e10 15 e 10 100 H223N 477.00 H223NRB 724.00 7-1/2 15 e 15 30 e 20 200 H224N 859.00 H224NRB 1041.00 15 25 e —60 e 40 400 H225N 2061.00 H225NR 2830.00 H225NDS 9858.00 — —H225NAWK 2869.00 —50 e —125 e 50 600 H226N 3879.00 H226NR 5118.00 H226NDS 14054.00 — —H226NAWK 4624.00 —75 e —200 e 50 800 H227N 6711.00 H227NRg 8144.00 — — — —H227NAWK 8225.00 50 —50 —50 1200 H228N 8281.00 H228NRg 11110.00 — — — —H228NAWK 11456.00 50 —50 —50 3 Wire (3 Blades and Fuseholders)—240 Vac, 250 Vdc 30 Use 4 Wire DevicesFor 3 Wire Applications H321DS 1366.00 H321A 426.00 H321AWK 403.00 1-1/2 3 3 7-1/2 5 60 H322DS 1688.00 H322A 609.00 H322AWK 576.00 3 7-1/2 10 15 10 100 H323DS 3564.00 H323A 941.00 H323AWK 887.00 7-1/2 15 15 30 20 200 H324DS 4997.00 H324A 1360.00 H324AWK 1284.00 15 25 —60 40 400 H325 2283.00 H325R 2650.00 H325DS 9974.00 — —H325AWK 2835.00 —50 —125 50 600 H326 4113.00 H326R 5524.00 H326DS 14266.00 — —H326AWK 4910.00 —75 —200 50 800 H327 7637.00 H327Rg 9899.00 — — — —H327AWK 9685.00 50 100 50 250 50 1200 H328 9678.00 H328Rg 12485.00 — — — —H328AWK 11633.00 50 100 50 250 50 4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac, 250 Vdc 30 H321N 209.00 H321NRB 370.00 Use 3 Wire Devices,Field-Installable Solid Neutral AssembliesOrder Separately. See page 3-10 1-1/2 3 3 7-1/2 5 60 H322N 352.00 H322NRB 594.00 3 7-1/2 10 15 10 100 H323N 561.00 H323NRB 852.00 7-1/2 15 15 30 20 200 H324N 967.00 H324NRB 1165.00 15 25 —60 40 400 H325N 2525.00 H325NR 2881.00 H325NDS 10214.00 — —H325NAWK 3090.00 —50 —125 50 600 H326N 4346.00 H326NR 5748.00 H326NDS 14506.00 — —H326NAWK 5171.00 —75 —200 50 800 H327N 8126.00 H327NRg 10375.00 — — — —H327NAWK 10586.00 50 100 50 250 50 1200 H328N 10209.00 H328NRg 13139.00 — — — —H328NAWK 13343.00 50 100 50 250 50 4 Wire (4 Blades and Fuseholders) 30 Use 600 Vac Devices. See page 3-5. 60 100 200 400 600 a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. For NEMA 3R applications, remove drain screw from bottom endwall. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c Refer to page 7-31 for additional motor application data. The starting current of motors of more than standard horsepower may require the use of fuses with appropriate time delay characteristics. d For switching dc, use two switching poles. e For corner grounded delta systems only and with neutral assembly installed. Use switching poles for ungrounded conductors. f 60 ampere switch with 30 ampere fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks. g Suitable for NEMA 5 applications with drain screw installed. DE1 Discount Schedule www.schneider-electric.us 3 SA F E T Y S W I T C H E S © 2007 Schneider Electric All Rights Reserved 3-5 Heavy Duty Safety Switches 600 Volt Class 3110 Class H Fuse Provisions: Fusible Square D 30 through 600 A heavy duty safety switches accept Class H fuses as standard. With Class H fuses installed, the switch is UL Listed for use on systems with up to 10 kA available fault current. Class R Fuse Provisions: Fusible Square D 30–600 A heavy duty safety switches will accept Class R fuses as standard. A field-installable rejection kit is available which, when installed, rejects all but Class R fuses. With the installation of the rejection kit and Class R fuses, the switch is UL Listed for use on systems with up to 200 kA available fault current. See Class R fuse kits on page 3-9. Class J Fuse Provisions: Provisions for installing Class J fuses are included in 30 through 400 A 600 Volt, and 100 through 400 A 240 Volt, fusible heavy duty safety switches. Conversion to Class J fuse spacing requires relocating the load side fuse base assembly from the standard Class H fuse location to an alternate position as marked in the enclosure. With Class J fuses installed, the switch is UL Listed for use on systems with up to 200 kA available fault current. Switches rated 600 A, 240 or 600 Volt, require the addition of an adapter kit, H600J at $304. One kit per 3P switch. Class L Fuse Provisions: Fusible 800 A and 1200 A safety switches use Class L bolt-in fuses and are rated for use on systems with up to 200 kA at 600 Vac maximum. 1200 A switches accept class L fuses from 601–1200 A, 800 A switches accept class L fuses from 601–800 A. Dimensions: NEMA 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-12 Dimensions: NEMA 4, 4X and 5 . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-13 Accessories: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 3-9 through 3-11 Table 3.11: 600 Volts—Single Throw Fusible System Amperes NEMA 1Indoor NEMA 3RRainproof(Bolt-on Hubs,page 3-9) NEMA 4, 4X, 5a304 Stainless Steel(for 316 stainless, see page 3-7) Dust tight, Watertight, Corrosion Resistant(Watertight Hubs, page 3-9) NEMA 12KWith Knockouts(Watertight Hubs,page 3-9) NEMA 12, 3RbWithout Knockouts(Watertight Hubs,page 3-9) Horsepower Ratingsc 480 Vac 600 Vac dce Std.(Using Fast Acting, One Time Fuses) Max.(Using Dual Element, Time Delay Fuses) Std.(Using Fast Acting, One Time Fuses) Max.(Using Dual Element, Time Delay Fuses) Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 3Ø 3Ø 3Ø 3Ø 250 600 2 Wire (2 Blades and Fuseholders)—600 Vac, 600 Vdc 30 Use 3 Wire DevicesFor 2 Wire Applications — ————— 60 — ————— 100 — ————— 200 — ————— 400 H265 2804.00 H265R 3616.00 H265DS 9974.00 — —H265AWK 3350.00 100d 250d ——50 50 600 H266 4435.00 H266R 7124.00 H266DS 14266.00 — —H266AWK 4894.00 150d 400d ——50 50 800 H267 6910.00 H267Rg 10923.00 — — — —H267AWK 10184.00 — — — —50 50 1200 H268 9713.00 H268Rg 11994.00 — — — —H268AWK 12029.00 — — — —50 50 3 Wire (3 Blades and Fuseholders)—600 Vac, 600 Vdce 30 H361 352.00 H361RB 599.00 H361DS 1680.00 H361A 676.00 H361AWK 637.00 5157-1/220515 30 H3612f 411.00 H3612RBf 699.00 — —H3612Af 690.00 H3612AWKf 651.00 5157-1/220—1560H362425.00 H362RB 703.00 H362DS 1847.00 H362A 698.00 H362AWK 656.00 15 30 15 50 —30 100 H363 792.00 H363RB 1096.00 H363DS 3662.00 H363A 1084.00 H363AWK 1026.00 25 60 30 75 —50 200 H364 1138.00 H364RB 1506.00 H364DS 5123.00 H364A 1696.00 H364AWK 1600.00 50 125 60 150 40 50 400 H365 3034.00 H365R 3688.00 H365DS 10214.00 — —H365AWK 3641.00 100 250 125 350 50 50 600 H366 5099.00 H366R 7266.00 H366DS 14056.00 — —H366AWK 6135.00 150 400 200 500 50 50 800 H367 8879.00 H367R g 11000.00 — — — —H367AWK 10901.00 200 500 250 500 50 50 1200 H368 11671.00 H368Rg 13339.00 — — — —H368AWK 13137.00 200 500 250 500 50 50 4 Wire (3 Blades and Fuseholders, 1 Neutral)—600 Vac, 600 Vdce 30 H361N 411.00 H361NRB 657.00 Use 3 Wire Devices Field-Installable Solid NeutralAssemblies. Order Separately. See page 3-10 5157-1/220—1560H362N473.0 H362NRB 756.00 15 30 15 50 —30100H363N852.00 H363NRB 1158.00 25 60 30 75 —50200H364N1246.00 H364NRB 1605.00 H364NDS 5247.00 H364NA 1810.00 H364NAWK 1705.00 50 125 60 150 40 50400H365N3265.00 H365NR 3843.00 H365NDS 10445.00 — —H365NAWK 3882.00 100 250 125 350 50 50600H366N5346.00 H366NR 7369.00 H366NDS 14748.00 — —H366NAWK 6400.00 150 400 200 500 50 50800H367N9362.00 H367NRg 11470.00 — — — —H367NAWK 11502.00 200 500 250 500 50 501200H368N12076.00 H368NRg 13995.00 — — — —H368NAWK 13880.00 200 500 250 500 50 50 4 Wire (4 Blades and Fuseholders)—600 Vac, 600 Vdch 2Ø 2Ø 2Ø 2Ø 30 H461 609.00 — —H461DS 1958.00 — —H461AWK 743.00 7-1/2 20 10 25 5 15 60 H462 710.00 — —H462DS 2046.00 — —H462AWK 838.00 15 40 20 50 10 30 100 H463 1185.00 — —H463DS 5563.00 — —H463AWK 1288.00 25 50 30 75 20 30 200 H464 1971.00 — —H464DS 8397.00 — —H464AWK 2148.00 50 —50 —40 50 400 H465 4140.00 — — — — — —H465AWK 4538.00 100 250 125 350 50 50 600 H466 6736.00 — — — — — — — — 150 400 200 500 50 50 6 Wire (6 Blades and Fuseholders)—600 Vac h 3Ø 3Ø 3Ø 3Ø 100 —— — —H663DS 17309.00 — —H663AWK 3408.00 25 60 30 75 —— 200 —— — —H664DS 23595.00 — —H664AWK 8148.00 For applications requiring motor disconnect capability, use electrical interlock. Refer to page 3-9. a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c Refer to page 7-35 for additional motor application data. The starting current of motors of more than standard horsepower may require the use of fuses with appropriate time delay characteristics. d For corner grounded delta systems only and with neutral assembly installed. Use switching poles for ungrounded conductors. e On 3P devices, use two outside poles for switching dc. f 60 A switch with 30 A fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks. g Suitable for NEMA 5 applications with drain screw installed. h Not suitable for use as service equipment. Class R Fuse DE1 Discount Schedule www.schneider-electric.us 3 S A F E T Y S W I T C H E S 3-6 © 2007 Schneider Electric All Rights Reserved Heavy Duty Safety Switches UL Listed Maximum Short Circuit Current Ratings—AC only NOTE:Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. m On 600 V, 200 A switches, 100,000 A max. on corner grounded delta when protected by Class J or R fuses. Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used in conjunction with an non-fused safety switch when there is up to 10 kA short circuit current available. (See table below.) Above 10, kA—When applied on systems with greater than 10 kA short circuit current available, the UL Listed short circuit current rating for Square D non-fused switches is based upon the switch being used in conjunction with fuses or Square D circuit breakers or Mag-Gard motor circuit protectors. Table 3.12: 600 Volt—Single Throw Non-Fusible System Rating(A) NEMA 1Indoor NEMA 3RRainproof(Bolt-on Hubs, page 3-9) NEMA 4, 4X, 5 a304 Stainless Steel(for 316 stainless, see page 3-7)Dust tight, WatertightCorrosion Resistant(Watertight Hubs, page 3-9) NEMA 12KWithKnockouts(Watertight Hubs, page 3-9) NEMA 12, 3RbWithoutKnockouts(Watertight Hubs, page 3-9) Horsepower Ratings(Max.) c Volts ac dcd240 480 600 Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 250 600 2 Wire (2 Blades)—600 Vac, 600 Vdc 30 Use 3 Wire DevicesFor 2 Wire Applications —— — ——— — — 60 —— — ——— — — 100 —— — ——— — — 200 —— — ——— — — 400 HU265 1833.00 HU265R 2509.00 HU265DS 8541.00 — —HU265AWK 2141.00 — — — — — —50 50 600 HU266 3264.00 HU266R 5022.00 HU266DS 12303.00 — —HU266AWK 3605.00 — — — — — —50 50 800 HU267 4978.00 HU267Re 8589.00 — — — —HU267AWK 8638.00 50 —50 —50 ——50 1200 HU268 6817.00 HU268Re 11595.00 — — — —HU268AWK 11681.00 50 —50 ———50 50 3 Wire (3 Blades)—600 Vac, 600 Vdc 30 HU361 186.00 HU361RB 325.00 HU361DS 1413.00 HU361A 459.00 HU361AWK 431.00 5 10 7-1/2 20 10 30 5 15 30 HU361EIf 425.00 HU361RBEIf 564.00 HU361DSEIf 1653.00 HU361AEIf 698.00 HU361AWKEIf 671.00 5 10 7-1/2 20 10 30 5 15 30 HU3612g 246.00 HU3612RBg 425.00 — —HU3612Ag 473.00 HU3612AWKg 444.00 5 10 7-1/2 20 10 30 5 15 60 HU362 325.00 HU362RB 584.00 HU362DS 1680.00 HU362A 583.00 HU362AWK 555.00 10 20 25 50 30 60 10 30 60 —— — —HU362DSEIf 1981.00 — — — —10 20 25 50 30 60 10 30 100 HU363 522.00 HU363RB 817.00 HU363DS 3401.00 HU363A 843.00 HU363AWK 796.00 20 40 40 75 40 100 20 50 200 HU364 806.00 HU364RB 990.00 HU364DS 4640.00 HU364A 1131.00 HU364AWK 1069.00 15 60 50 125 50 150 40 50 400 HU365 1869.00 HU365R 2560.00 HU365DS 9529.00 — —HU365AWK 2682.00 —125 —250 —350 50 50 600 HU366 3328.00 HU366R 5122.00 HU366DS 12708.00 — —HU366AWK 4474.00 —200 —400 —500 50 50 800 HU367 6652.00 HU367Re 8700.00 — — — —HU367AWK 8731.00 50 250 50 500 50 500 50 50 1200 HU368 8947.00 HU368Re 11911.00 — — — —HU368AWK 11960.00 50 250 50 500 50 500 50 50 4 Wire (4 Blades)—600 Vac, 600 Vdck 2Ø 3Ø 2Ø 3Ø 2Ø 3Ø 30 HU461h 551.00 — —HU461DS 1724.00 — —HU461AWKi 610.00 10 10 20 20 25 30 10j 15j 60 HU462h 609.00 — —HU462DS 2018.00 — —HU462AWK 672.00 20 20 40 50 50 60 10 30 100 HU463h 1098.00 — —HU463DS 4934.00 — —HU463AWK 1194.00 30 40 50 75 50 75 20 30 200 HU464h 1599.00 — —HU464DS 7496.00 — —HU464AWK 1888.00 50 60 50 125 50 150 40 50 400 HU465 3467.00 — — — — — —HU465AWK 3781.00 — 125 — 250 —350 50 50 600 HU466 6048.00 — — — — — — — — — 200 — 400 — 500 50 50 6 Wire (6 Blades)—600 Vack 3Ø 3Ø 3Ø 30 —— — —HU661DS 7935.00 — —HU661AWKl 2238.00 —10 —20 —30 —— 60 —— — —HU662DS 8836.00 — —HU662AWKl 2589.00 —20 —50 —60 —— 100 —— — —HU663DS 13762.00 — —HU663AWKl 3195.00 —40 —75 —75 —— 200 —— — —HU664DS 18877.00 — —HU664AWKl 7025.00 —60 —125 —150 —— a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c Refer to page 7-32 for additional motor application data. d For switching dc, use two switching poles. e Suitable for NEMA 5 applications with drain screw installed. f Switches with EI suffix are stocked with factory-installed electrical interlocks with one normally open and one normally closed contact. g Use 60 A enclosure accessories, including electrical interlocks. h No knockouts are provided. i Check series number on switch for correct accessory. See page 3-13. j HU461AWK (Series E1) is rated 5 hp@250 Vdc, 10 hp@600 Vdc. k Not suitable for use as service equipment. l One enclosure for NEMA 1, 3, 3R or 12 applications. UL Listed. Table 3.13: Fusible Safety Switches For the short circuit current rating, refer to the table below. Heavy DutySafety Switch Type UL ListedFuse Class UL Listed Short CircuitCurrent Ratings Fusible H, K 10 kA R, J, L 200 kAm Table 3.14: Maximum I 2t and Ip Ratings of Heavy Duty Switchesn Switch Rating(A)Max. I2t Rating(Amp2 sec.)Max Ip Rating(A) 30 50,000 14,000 60 200,000 26,000 100 500,000 32,000 200 2,000,000 50,000 400 6,000,000 75,000 600 12,000,000 100,000 800 10,000,000 80,000 1200 15,000,000 120,000 n Per UL 489, Table 7.12, page 7-11. Table 3.15: Non-Fusible Safety Switches Heavy Duty Safety Switch Type Switch Rating(A) o Fuse or Circuit Breaker Typep UL Listed Short Circuit Current Rating Non-FusedSwitches All Any Brand Circuit Breaker Up to 10 kAH, K R,T,J.L 200 kA 30–100 FA 14 kA 30–100 FH 18 kA 200 KA 22 kA400 LA 600 MA 200 KH 25 kA400 LH 600 MH o Applies to NEMA 1, 3R, 4X stainless, 12 switches. p Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. DE1 Discount Schedule Modified4/17/09 www.schneider-electric.us 3 SA F E T Y S W I T C H E S © 2007 Schneider Electric All Rights Reserved 3-7 Heavy Duty Safety Switches–Special Applications Class 3110 316 Grade Stainless Steel—NEMA 3, 3R, 4, 4X, 5, 12 Type 316 stainless steel enclosure safety switches offer superior corrosion resistance to a wider range of chemicals than Type 304 stainless switches. Type 316 better resists chloride and is often used in marine, waste treatment and transportation applications. Use watertight hubs from page 3-9. Equipment grounding lugs are supplied as standard. (For Type 304 stainless switches see pages 3-4–3-6.) Fiberglass Reinforced Polyester Enclosures—NEMA 4X Fiberglass reinforced polyester enclosures are watertight, corrosion resistant, and impervious to windblown dust, rain, and splashing liquid. The molded fiberglass is extremely stable in a wide range of operating temperatures and can withstand heavy impact. Switches are furnished with hubs (page 3-13) and equipment grounding lugs. UL Listed. Krydon® Enclosures—NEMA 4X Krydon enclosures are compression molded of fiberglass reinforced polyester, specially formulated to withstand attack from almost any corrosive atmosphere found in the toughest industrial application. Switches are furnished with hubs (page 3-13) and equipment grounding lugs. UL Listed. NEMA 7 and 9 An enclosed automatic molded case switch for use in Divisions 1 and 2 of the following: Class I, Groups C and D; Class II, Groups E, F and G; or Class III, Hazardous Locations as defined in NEC® Article 500. Furnished with threaded conduit openings in both top and bottom endwall (page 3-13). Suitable for use as service equipment and listed as “Raintight’’ for outdoor applications. UL Listed, and CSA Certified. Equipment grounding lugs supplied as standard. a Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. b For switching dc use two switching poles. c For EI Kit information and pricing refer to page 3-9. d Not suitable for use as service equipment. e Electrical interlock not available. For auxiliary switches, refer to page 7-4 for catalog number suffix and price adder (e.g. H60XFA1212). f Includes PKDB1, breather and drain kit, required for rainproof application—NEMA 7 only. g Not UL Listed or CSA Certified due to wire bending space requirements. Table 3.16: 3P 600 Vac, 600 Vdc Amperes Cat. No $ Price Horsepower Ratings– 3Øa 480 Vac 600 Vac 600 Vdcb Std. Max. Std. Max. Max. Fusible 30 H361SS 2296.00 5157-1/22015 60 H362SS 2528.00 15 30 15 50 30 100 H363SS 5041.00 25 60 30 75 50 200 H364SS 7061.00 50 125 60 150 50 Non-Fusible 30 HU361SS 1932.00 —20 —30 15 60 HU362SS 2296.00 —50 —60 30 100 HU363SS 4686.00 —75 —100 50 200 HU364SS 6415.00 —125 —150 50 Table 3.17: 3P 600 Vac, 600 Vdc Amperes Cat. No. $ Price Class R Fuse Kits Electrical Interlock Kits Field-Installable Cat. No. c Horsepower Ratings– 3Øa 480 Vac 600 Vac 600 Vdcb Cat. No. $ Price 1 NO/1 NC Contact 2 NO/2 NC Contacts Std. Max. Std. Max. Max. Fusible 30 H361DF 2380.00 RFK06 17.00 9999TC10 9999TC20 5 15 7-1/2 20 15 60 H362DF 2645.00 RFK06H 17.00 9999TC10 9999TC20 15 30 15 50 30 100 H363DF 5075.00 RFK10 31.80 9999TC10 9999TC20 25 60 30 75 50 200 H364DFd 6486.00 HRK1020 31.80 9999R8 9999R9 50 125 60 150 50 Non-Fusible 30 HU361DF 2268.00 — —9999TC10 9999TC20 —20 —30 15 60 HU362DF 2521.00 — —9999TC10 9999TC20 —50 —60 30 100 HU363DF 4827.00 — —9999TC10 9999TC20 —75 —100 50 200 HU364DFd 6463.00 — —9999R8 9999R9 —125 ——50 Table 3.18: 3P, 600 Vac, 600 Vdc Amperes Cat. No. $ Price Class R Fuse Kits Electrical Interlock KitsField-Installable Cat. No. c Horsepower Ratings– 3Øa 480 Vac 600 Vac 600 Vdcb Cat. No. $ Price 1 NO/1 NC Contact 2 NO/2 NC Contacts Std. Max. Std. Max. Max. Fusible 30 H361DX 2774.00 RFK06 17.00 9999TC10 9999TC20 5 15 7 1⁄2 20 15 60 H362DX 3084.00 RFK06H 17.00 9999TC10 9999TC20 15 30 15 50 30 100 H363DX 5905.00 RFK10 31.80 9999TC10 9999TC20 25 60 30 75 50 Non-Fusible 30 HU361DX 2640.00 — —9999TC10 9999TC20 —20 —30 15 60 HU362DX 2937.00 — —9999TC10 9999TC20 —50 —60 30 100 HU363DX 5625.00 — —9999TC10 9999TC20 —75 —100 50 Table 3.19: 3P, Non-Fusible, 600 Vac, 250 Vdc Maximum, Short Circuit Rating 10 kA AIR Amperes Enclosed Molded Case Switchf Solid Neutral Assembly Horsepower Ratings—3Ø Cat. No.g $ Price Cat. No. $ Price 240 Vac 480 Vac 600 Vacb 60 H60XFA 1714.00 100SNA 95.00 15 30 50 60 H60XFA1212 1924.00 100SNA 95.00 15 30 50 100 H100XFA 2030.00 100SNA 95.00 30 60 75 100 H100XFA1212 2191.00 100SNA 95.00 30 60 75 225 H225XKAg 4258.00 225SNA 126.00 60 125 150 H362SS H363DF H361DX H60XFA DE1 Discount Schedule MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL