HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00037 - Ashbury Meadows AptsPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 12/18/2019 1:58 pm
Permit Details Permit Number: 12-00037
Ashbury Meadows Apts
333 W 6th S
New Multi-Family Residence
Permit Issued Date: 07/11/2014
Permit Inspection Statistics
35Total Inspections Completed:
28Total Inspections Passed:
Inspection Pass Rate: 80.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/03/2012PassPLL ADMINFooting Inspection
As Per Jon Berry.
OK 4/13 Elevator footings
4/13/12 Footings look good.
4/2/12 All footings OK to pour
Inspector Comments:
04/20/2012PassPLL ADMINFoundation Inspection
As Per Jon Berry.
4/20 - Foundation - partial S. wall 1/2 west wall E wall minus elev/lobby and 1/2
N wall plus columns
4/26 - Concrete Wall - east lobby and elevator area rebar and forms ok
5/9 - Rebar Slab & In-wall - South slab 1st level and N. middle wall look good
5/11 - Slab on grade - Slab NE half looks good
7/16 west half of upper PT slab rebar and cables looks good SI to verify.
5/23 - Concrete, wall, foundation - Slab on grade OK NW corner. Hold rebar
above grade
5/17 SW corner foundation 1st lvl garage OK
5/29 - Rebar PT Deck - Rebar and cables look good for 1st PT slab east half
6/7 West half of PT slab 1st floor look good
6/15 East end 2nd level walls and rebar look good.
6/28 (QO) West end foundation walls & columns OK.
6/29 (QO) East 2nd floor slab ok so far. Pour Sat. morning- Spec. Insp & Engr
will also inspect.
Inspector Comments:
09/07/2012PassPLL ADMINSheeting
Sheathing & Nailing on first floor. As Per Jon Berry. 1st floor sheathing OK as
noted.
Inspector Comments:
10/03/2012FailQuinton OwensInsulation Inspection
R-19 & R-21 in exterior walls windows ufactor = .28
* Most windows not sealed across bottom
*Some Int/Ext wall intersections not insulated
Note: Be sure insulation R-value label faces the interior.
Inspector Comments:
Page 1 of 6
(Continued)
Permit Details Permit Number: 12-00037
Ashbury Meadows Apts
333 W 6th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 12/18/2019 1:58 pm
Permit
Inspection
Summary
10/05/2012FailPLL ADMINInsulation Inspection
As Per Jon Berry.
1- A-35s missing at Pantrywalls see #4 sheet 702
2- Several window bottoms not sealed
3- Insulation 1st floor ok to cover.
4- Dummy data boxes not allowed in fire rated walls (Pantry and Corr) USG full
boxes.
Inspector Comments:
10/09/2012FailQuinton OwensFraming/Structure Inspection
10/9 (QO) 2nd floor rough framing. (unblocked sheathing joints above some
windows. Penetrations above dropped ceilings to be fire-caulked. Mgr bath ceiling
dropped below drywall fire-block. NW unit has broken stud at bathroom
(plumbers making holes too big). NE unit Protective plates for plumbing not done
(see plumb. insp.) Drywall SE unit 1st level ok for taping.
Inspector Comments:
10/22/2012PassPLL ADMINFraming/Structure Inspection
As Per Jon Berry.
SE corner floor framing on slab approved: R-19 and R-7.5 foam board with
sleepers (7-24, QO)
7/27 1st Floor framing completed except for plumbing CW
9/7 sheathing on 1st floor ok to cover. 1/2 floor straps installed CW
9/17 Sheathing on 2nd and 3rd floors ok to cover. straps mostly in place except
south side. East 1/3rd roof sheathing ok to cover.
10/8 1st floor completed (need engineers ok on party wall a-35 clips)
Dummy boxes for data C/Not be used in party walls.
10/22 Framing completed
Inspector Comments:
10/22/2012PassPLL ADMINInsulation Inspection
As per Jon Berry. Insulation 2 & 3 looks good. Framing on 3 & 4 looks good.Inspector Comments:
10/22/2012PassPLL ADMINSheetrock/Drywall Inspection
Inspector not indicated. 10/22 drywall on 1st floor ok to coverInspector Comments:
12/28/2012FailQuinton OwensBuilding Final
FINAL FOR TEMPORARY CO PERMIT
12/28: Fire separation not maintained at penetrations in Mech. closet and under
kitchen sink and bathrooms. S.D. in very N.W. corner bdrm of 1st floor not
working. (Also 2 SD not working in unit East of coutyard). No Apt #'s posted.
Need rated penetrations above garage. Mgr unit missing handrails. Missing
Handrail on one side of NE stairs. Fix stair handrail returns on west side.
Inspector Comments:
Page 2 of 6
(Continued)
Permit Details Permit Number: 12-00037
Ashbury Meadows Apts
333 W 6th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 12/18/2019 1:58 pm
Permit
Inspection
Summary
01/28/2013FailQuinton OwensBuilding Final
1/2/13: Mgr. Unit Missing Handrails. Firecaulking must fill annular space (not just
on surface of regular caulk) or install fire collars around drain pipe.
Directional arrow on 3rd floor exit sign East end. 3rd floor Rec. room bathroom
has no grab bars or pipe covers. Emergency lights at 4th level of ast stairs
missing. Directional arrow at bottom of west stairs' exit sign. Missing some
handrail extensions on west exterior stairs. Firecaulk gas pip penetration behind
rec. room fireplace.
Inspector Comments:
01/30/2013PassQuinton OwensBuilding Final
1/02: mgr unit handrails to return to wall. Firecaulking must fill annular space
(not just on surface of regular caulk).
1/04: Firecaulked penetrations done. Temp CO for 1st & 2nd floor & 2nd level
parking OK. waiting on mgr unit hndrl to return to wall.
Inspector Comments:
Page 3 of 6
(Continued)
Permit Details Permit Number: 12-00037
Ashbury Meadows Apts
333 W 6th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 12/18/2019 1:58 pm
Permit
Inspection
Summary
Electrical Inspection Type
10/01/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-nail plates are being installed-will re-inspect nail plates and
SER cable supporting on the next rough-in inspection on the next floor.
Inspector Comments:
10/08/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover in the second level units only-not the hallways or corridors.
Approved for cover in the hallway(corridor) on the first level except the stairways.
Inspector Comments:
10/17/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover in the 3rd floor units only.Inspector Comments:
10/23/2012N/ABret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
No inspection-unintelligible message left on the inspection hotline that seemed to
indicate a request to cancel inspection as it was not ready. Several attempts were
made to contact for verification, but were unsuccessful-as per Jane Shaw.
Inspector Comments:
10/24/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover in the 4th floor units only, not the hallway-some stapling is
needed in the hallway-as per Jane Shaw.
Inspector Comments:
10/31/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover in the hallways on the 1st and 2nd floors excluding the
stairways.
Inspector Comments:
11/06/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-all six locations - RMP had to
feed this building with this many services.
Inspector Comments:
12/21/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for finals in the units on the first and second floors excluding the
hallways and a few items listed below, A/C units are 30A OCPD-possibly to large
for units, ranges are #8 wire on 50A OCPD's-to large, receptacle not installed
behind bedroom door on second floor NW end, NM-B cable is not protected in the
east unit on the first floor in the peninsula, will re-inspect on the next final
inspection.
Inspector Comments:
12/31/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
AFCI tripping in the managers unit, reverse polarity in the kitchen circuit in the
managers unit, receptacle is not cut into the kitchen cabinet peninsula in the
managers unit, heater covers in the hallway not installed, 2nd floor parking area
not done, range breakers are 50A on #8 wire-need to have 40A max installed,
call for a re-inspect when ready.
Inspector Comments:
01/10/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
1/2/13: Approve fot a final TCO for the 1st and 2nd levels only.
Approved for a final-level one parking outside of the construction fenced area
only.
Inspector Comments:
Page 4 of 6
(Continued)
Permit Details Permit Number: 12-00037
Ashbury Meadows Apts
333 W 6th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 12/18/2019 1:58 pm
Permit
Inspection
Summary
01/22/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-entire building-heat tape circuits in the fourth floor
panel blanked off and no heat tape is installed.
Inspector Comments:
Fire Inspection Type
06/14/2012PassDale PickeringFire Sprinkler Hydro
06/27/2012PassBret StoddardFire Underground Inspection
Fire Line Flush: Approved as witnessed-15 minute flush with 4" discharge
hose(3:56PM-4:12PM).
Inspector Comments:
09/28/2012PassPLL ADMINFire Sprinkler Rough-in
As Per Jon Berry. 9/28 Sprinkler rough 1st and 2nd floors ok to cover.Inspector Comments:
12/31/2012PassBret StoddardFire Alarm Final Inspection
Fire-Sprinkler Final. TI
Extinguisher Final. TI
Fire Alarm Final. TI
Hydrostatic Call 3 floors: 200 @ 11 200 @13 Pass
Approved for a final-1st and second floors, witnessed 24 hour/5 minute test on
entire system(all floors), elevator recall and smoke detector in the top of the
shaft is not done, PIV does not have tamper switch installed on it outside, call for
a re-inspect when ready.
Inspector Comments:
Mechanical Inspection Type
10/29/2012PassPLL ADMINHVAC Rough-in
As Per Jon Berry.
9/24 Duct rough looks good ok to cover 1/2 floors
10/11 3rd floor looks good ok to cover
10/25 4th floor HVAC in units completed common areas still in work. Reducer
seam needs sealing.
Inspector Comments:
01/30/2013PassQuinton OwensHVAC Final Inspection
12/20: Temp floors 1&2 only and 2nd level parking. OK for Mech other than
fire-caulking required penetrations. (see Bldg final).
1/18: Apt. level 3 & 4 pending approval of firestop foam around plastic vent
pipe(Abesco FP200)
1/28: Firecaulked places previously filled with firestop foam.
Inspector Comments:
Page 5 of 6
(Continued)
Permit Details Permit Number: 12-00037
Ashbury Meadows Apts
333 W 6th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 12/18/2019 1:58 pm
Permit
Inspection
Summary
Plumbing Inspection Type
06/04/2012PassDon AllenPlumbing Sewer
All good to cover.Inspector Comments:
08/02/2012PassDon AllenPlumbing Rough-in
7/23/12 - Southeast 2 apartment are good on the grade work.
7/26/12 - Southwest cover of apt building all good to cover ground work.
8/1/12 - The underground for the apt. on the Northwest side.
8/2/12 - All good to cover the ground work on the northeast apt.
Inspector Comments:
08/03/2012PassDon AllenPlumbing Underground Inspection
Underground slab on-gradeInspector Comments:
11/13/2012PassDon AllenWater Meter Inspection
Water-line Pressure Test. All good to cover.Inspector Comments:
02/08/2013PassDon AllenPlumbing Water
02/08/2013PassDon AllenPlumbing Final Inspection
12/28/12: 2nd floor northwest apt need dishwasher hose put up the the top of
stall. 2nds floor northeast apt. kitchen need a P-TRAP. Need to check maryer apt.
not done.
1/22/13: All good for the C/O
1/24/13: All good for the C/O
Inspector Comments: