HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00027 - 426 Farnsworth Way, #3 Rigby Tenant FinishPermit Inspection Summary Permit Status of (Open) as of Report Date: 12/18/2019 11:03 am Permit Details Permit Number: 12-00027 426 Farnsworth Way, #3 Rigby Tenant Fin. 426 Farnsworth Way, Rigby Commercial Tenant Finish Rigby Permit Issued Date: 07/09/2014 Permit Inspection Statistics 12Total Inspections Completed: 10Total Inspections Passed: Inspection Pass Rate: 83.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 01/18/2012PassSAUREY AMANDAFoundation Inspection Previously approved by City of RigbyInspector Comments: 01/19/2012PassQuinton OwensFraming/Structure Inspection Sheathing & Firewall inspections done by Mike McGowen. This inspection was for tenant framing. Inspector Comments: 01/23/2012PassQuinton OwensInsulation Inspection no vapor barrier installed.. paint to be vapor barrier. dual lighting or occupancy sensors required per IECC Exit sign required above door from hallway to lobby. Inspector Comments: 01/25/2012PassQuinton OwensSheetrock/Drywall Inspection North and south window need to be sealed around perimeter.Inspector Comments: 02/24/2012FailQuinton OwensBuilding Final ADA bathroom: Pipe protection under sink required. Change in floor surface greater than 1/4" must be beveled or ramped (if > 1/2") - at ADA restroom and front entry to hallway. This unit, south end, is identified as unit 1, not 3. Rigby can decide to approve numbering or not. Inspector Comments: 02/28/2012PassQuinton OwensBuilding Final Electrical Inspection Type 01/19/2012PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in Approved for cover in the far south tenant space-service was inspected by the State (DBS), 6 exam rooms wired with green (redundant grounding MC cable). Inspector Comments: 02/24/2012PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-panel and SE cable inspected by the State (DBS), No A/C unit was installed-disconnect only (30A)-separate permit will be required for A/C unit later. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00027 426 Farnsworth Way, #3 Rigby Tenant Fin. 426 Farnsworth Way, Rigby Commercial Tenant Finish Rigby Permit Status of (Open) as of Report Date: 12/18/2019 11:03 am Permit Inspection Summary Mechanical Inspection Type 01/19/2012PassQuinton OwensHVAC Rough-in Gas line pressure test done by others.Inspector Comments: 02/24/2012FailQuinton OwensHVAC Final Inspection need to label or be able to identify regulator & installation compliance.Inspector Comments: 02/28/2012PassQuinton OwensHVAC Final Inspection Brought identical regulator still in package with tag. Tag ok's regulator to not be vented in horizontal position. Inspector Comments: Plumbing Inspection Type 01/18/2012PassSAUREY AMANDAPlumbing Rough-in Previously approved by the State of Idaho.Inspector Comments: Page 2 of 2