Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00022 - 76 E 1st S - SFR RemodelPermit Inspection Summary Permit Status of (Open) as of Report Date: 12/18/2019 9:50 am Permit Details Permit Number: 12-00022 76 E 1st S - SFR Remodel 76 E 1st S Single Family - Remodel Permit Issued Date: 07/08/2014 Permit Inspection Statistics 17Total Inspections Completed: 14Total Inspections Passed: Inspection Pass Rate: 82.35% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 03/13/2012FailQuinton OwensFraming/Structure Inspection Header missing above window (2x's on side do not count as header) Better sealant around window framing (caulking cracked already -outside also) Insulate around basement window. Smoke Det. missing outside bedroom. Inspector Comments: 03/13/2012PassQuinton OwensInsulation Inspection Insulate (foam) around bsmt window Better sealant around window framing needed Header missing above window Smoke det. outside bedroom Inspector Comments: 03/23/2012PassQuinton OwensFraming/Structure Inspection 03/23/2012PassQuinton OwensSheetrock/Drywall Inspection 2 hr ceiling and walls between Office space and apt. Will need fire rings around plastic pipe penetrations. Inspector Comments: 04/13/2012FailQuinton OwensBuilding Final Handrail return to wall (top&bottom) 34-38" high. Fire ring around ABS pipes in mech. room behind tub (Fire caulk upper pipe if too big for fire ring). Window well egress ladder. Corridor openings-doors (20 min. rating). Underside of stairs OK - not enclosed (framing only, no drywall). Inspector Comments: 10/30/2012PassQuinton OwensBuilding Final 11/01/2012PassQuinton OwensSidewalk Inspection Existing. no inspection required.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00022 76 E 1st S - SFR Remodel 76 E 1st S Single Family - Remodel Permit Status of (Open) as of Report Date: 12/18/2019 9:50 am Permit Inspection Summary Electrical Inspection Type 03/07/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-basement remodel-service is Approved to be energized for permanent power-existing service reused-no separate ticket was written for the service inspection-inspected this on the rough-in. Inspector Comments: 03/07/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-inspected this on the rough-in.Inspector Comments: 04/12/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to install K.O. seals in the junction box in the ceiling above the panel, need to install covers on the junction box in the storage room and the one above the panel, range wire only approved for 40A max breaker size-50A installed(#8), outlets in the bedroom not working(4), verify that the heaters in the unit have double pole thermostats-breaker locks required if not, call for a re-inspect when ready. Inspector Comments: 04/13/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-basement remodel-the side under the eye center only. Inspector Comments: Mechanical Inspection Type 03/09/2012PassQuinton OwensHVAC Rough-in Mech Rough-in OKInspector Comments: Plumbing Inspection Type 02/22/2012PassDon AllenPlumbing Underground Inspection All good to coverInspector Comments: 03/14/2012PassDon AllenPlumbing Rough-in Roughin all good.Inspector Comments: 05/01/2012PassDon AllenPlumbing Final Inspection All good for c/oInspector Comments: 05/01/2012PassDon AllenPlumbing Sewer 05/01/2012PassDon AllenPlumbing Water Page 2 of 2