Loading...
HomeMy WebLinkAboutRESCHECK - 19-00745 - Webb - New SFRREScheck Software Version 4.6.5 Compliance Certificate Project T.Webb Cons-Michael & Elisse Shurtliff Energy Code:2015 IECC Location:Ammon, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:3,679 ft2 Glazing Area 13% Climate Zone:6 (7918 HDD) Permit Date: Construction Site:Owner/Agent: T.Webb Cons-Michael & Elisse Shurtliff Designer/Contractor: Freedom Heating, Inc. Freedom Heating, Inc. P.O Box 51966 Idaho Falls, ID 83405 208-339-0344 Freedomheatinginc@yahoo.com Permit Number: Compliance: Passes using UA trade-off 0.3% Better Than Code Maximum UA:328 Your UA:327 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.582 21.0 0.0 0.057 25 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 143 0.320 46 Wall 2: Wood Frame, 16" o.c.406 21.0 0.0 0.057 21 Door 1: Solid 21 0.140 3 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.320 4 Wall 3: Wood Frame, 16" o.c.582 21.0 0.0 0.057 29 Door 1: Solid 42 0.140 6 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 33 0.320 11 Wall 4: Wood Frame, 16" o.c.402 21.0 0.0 0.057 23 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 614 19.0 0.0 0.045 26 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.320 10 Basement Wall 2: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 430 19.0 0.0 0.045 18 Project Title: T.Webb Cons-Michael & Elisse Shurtliff Data filename: C:\Users\Freedom Heating\Documents\REScheck\T.Webb Cons-Michael & Elisse Shurtliff.rck Page 1 of 2 06/10/19Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.320 10 Basement Wall 3: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 614 19.0 0.0 0.045 28 Basement Wall 4: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 430 19.0 0.0 0.045 19 Ceiling 1: Flat Ceiling or Scissor Truss 1,863 50.0 0.0 0.026 48 Freedom Heating, Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: T.Webb Cons-Michael & Elisse Shurtliff INFORMATION CONTAIN WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: T.Webb Cons-Michael & Elisse Shurtliff Data filename: C:\Users\Freedom Heating\Documents\REScheck\T.Webb Cons-Michael & Elisse Shurtliff.rck Page 2 of 2 06/10/19Report date: 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 21.00Above-Grade Wall 19.00Below-Grade Wall 0.00Floor 50.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.32Window 0.14Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments