Loading...
HomeMy WebLinkAboutPLANS - 19-00745 - Webb - New SFRR E V I S I O N T A B L E N U M B E R D A T E R E V I S E D B Y D E S C R I P T I O N D R A W I N G S P R O V I D E D B Y : DATE: R i v e r B e n d D r a f t i n g a n d D e s i g n E l i s e S h u r t l i f f 2 0 8 -5 5 7 -3 6 2 1 E l i s e @ r i v e r b e n d h o u s e p l a n s .c o m 11/26/2019 T W e b b C o n s t r u c t i o n P i n e B r o o k E s t a t e s D i v . 2 , B l o c k 6 , L o t 1 4 Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers or more refer to TJXert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathroom 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already Ventilation R408.1 The under-floor space between the bottom of the floor joistand the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor area, unless the ground surface is covered by a class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of the building. Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft w/min horiz projection & width of 36" Exception: Window Wells w/ depth greater than 44" will have a permanently affixed ladder or steps Ladder or Steps 12" width Inside, 3" from walls, spaced no more than 18" O.C. Foundation Walls System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1/2" Anchor Bolts @72" O.C. 10" Long, 7" Embedded Max 12" from all Corners or Splices Concrete wall 8' and under (1) Horizontal Rebar in top 12" and one at mid height 8'1" TO 9'6" (1) Horizontal Rebar in top 12" and one bar at each third point Min (2) Anchor Bolts per Sill Plate w/nut & ROUND Plate Washer 2 1/20 x 1/4" Min. for each Bolt over Concrete Foundation Wall Consistent w/2012 IRC R401-403 with Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/2015 IRC Section R106.1 over Undisturbed Soil 3' Hallway Clearance 2015 IRC, Section R106 and R311.6 Safety Glazing 2015 IRC, Sections R106 and R308.4.5 Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Crawl Space: Through Floor min 18"x24" or through perimeter wall min 16"x24" required crawl space opening. If applicable, refer to mechanical code for access requirements where mechanical equipment is located under floors. 2015 IRC, Section R106, R408.4 M1305.1.4 Furnace: Location of furnace and water heater 2015 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2015 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2015 IRC, Section R106, M1307.3.1 General Notes For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Elise Shurtliff. General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by Elise Shurtliff. Braced Wall Lines 2015 IRC Code Section R602.10.1 For the Prupse of determining the amount and location of bracing required in each story level of a building, braced wall lines shall be designated as straight lines in the building plan The length of a braced wall line shall be the distance between its ends. The end of a braced wall line shall be the intersection with a perpendicular braced wall line, or an angled braced wall line as permitted in section R602.10.1.4 Pg 1 R E V I S I O N T A B L E N U M B E R D A T E R E V I S E D B Y D E S C R I P T I O N D R A W I N G S P R O V I D E D B Y : DATE: R i v e r B e n d D r a f t i n g a n d D e s i g n E l i s e S h u r t l i f f 2 0 8 -5 5 7 -3 6 2 1 E l i s e @ r i v e r b e n d h o u s e p l a n s .c o m Front Elevation Back ElevationElevations 7:12 Pitch Main, Front and sides 8' Main walls 9' Basement foundation walls Garage to match TYP 11/26/2019 T W e b b C o n s t r u c t i o n P i n e B r o o k E s t a t e s D i v . 2 , B l o c k 6 , L o t 1 4 Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by Elise Shurtliff. Pg 2 R E V I S I O N T A B L E N U M B E R D A T E R E V I S E D B Y D E S C R I P T I O N D R A W I N G S P R O V I D E D B Y : DATE: R i v e r B e n d D r a f t i n g a n d D e s i g n E l i s e S h u r t l i f f 2 0 8 -5 5 7 -3 6 2 1 E l i s e @ r i v e r b e n d h o u s e p l a n s .c o m Right Elevation Left Elevation Elevations cont.11/26/2019 7:12 Pitch Main, Front and sides 8' Main walls 9' Basement foundation walls Garage to match TYP T W e b b C o n s t r u c t i o n P i n e B r o o k E s t a t e s D i v . 2 , B l o c k 6 , L o t 1 4 Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by Elise Shurtliff. Pg 3 S S SS SS SS S S S S 81'-3" 2' 1 3 ' 6 '-5 " 1 2 '-1 0 " 4 5 ' 5 ' 7 ' 5 ' 5 '-8 " 12'16'-10"11'-6"24'-6" 81'-3" 2' 14'-5" 7 ' 5 '-9 " 3 2 '-3 " 7 ' 4 5 ' 3 '-6 " 5 ' 1 '-5 " 6'18'-6" 25'-11"13' 3 '-8 " 3 '-5 " 13'-2"12'-9"6'-0 1/2"7' 2 3 '-4 " 23'-10 1/2" 1 7 ' 6 '-4 " 2'-5 1/2"11'-11 1/2" 18'-10" 8 '-1 1 " 8 '-1 1 " 11'-4" 3'-1"13'-9"10'-8"9'-9"11'-3" 1 1 '-1 1 " 3 ' 4 '-1 0 " 6 '-6 " 10'3'-2"3'-3 1/2"18'-6" 4 '-8 " 2970 SQ FT GARAGE 4' Porch walls LIVING AREA 1st Floor R E V I S I O N T A B L E N U M B E R D A T E R E V I S E D B Y D E S C R I P T I O N D R A W I N G S P R O V I D E D B Y : DATE: R i v e r B e n d D r a f t i n g a n d D e s i g n E l i s e S h u r t l i f f 2 0 8 -5 5 7 -3 6 2 1 E l i s e @ r i v e r b e n d h o u s e p l a n s .c o m 11/26/2019 T W e b b C o n s t r u c t i o n P i n e B r o o k E s t a t e s D i v . 2 , B l o c k 6 , L o t 1 4 Footings Plan Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper 8' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP Footings with Sanna Tube General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by Elise Shurtliff. Pg 4 SSSSS S S S S S SB24R B24R SB24RSB24RB24RSB24R 2868 5050RS 4040RS 4 0 4 0 R S 4 0 4 0 R S 2 8 6 8 2 8 6 8 2668 2 8 6 8 2668 5068 2668 2868 2068 2868 UP 4 ' 81'-3" 2' 1 3 ' 6 '-5 " 1 2 '-1 0 " 4 5 ' 5 ' 7 ' 5 ' 5 '-8 " 12'16'-10"11'-6"24'-6" 81'-3" 2' 14'-5" 7 ' 5 '-9 " 3 2 '-3 " 7 ' 4 5 ' 3 '-6 " 5 ' 1 '-5 " 6'18'-6" 25'-11"13' 3 '-5 9 /1 6 " 3 '-7 7 /1 6 " 12'-10 1/8"13'-0 7/8"6'-6 7/8"6'-5 5/8" 2 3 '-4 " 23'-10 1/2" 1 7 ' 18'-10" 8 '-1 1 " 8 '-1 1 " 7 ' 6 ' 11'-4" 6 ' 6 '-1 0 " 3'-1"13'-9" 12'-0 1/2"10'11'-3 1/2" 29'-10"10' 40'-1 1/2" 5'-10"5'-10 1/2" 1 /2 " 1 2 '-7 1 /2 " 4 '-4 " 1 2 '-8 1 /2 " 19'-3"9'-1"9'-11 1/2" 1 /2 " 1 7 '-1 1 " 1 2 '-6 1 /2 " 2 '-1 " 3 '-8 1 /2 " 1 6 '-6 1 /2 " 2 '-1 " 1 4 '-7 " 1758 SQ FT 12'-0" X 18'-10" 9'-0" X 5'-7" 37'-7" X 23'-4" 9'-11" X 12'-8" 19'-2" X 10'-7" 9'-11" X 12'-7" 9'-11" X 12'-6" LIVING AREA GARAGE UTILITY THEATER ROOM BEDROOM BEDROOM BEDROOM STORAGE Cut 18' for Garage Door Opening with Req. Blocking Cut 9' for Garage Door Opening with Req. Blocking 4' Porch walls Foundation R E V I S I O N T A B L E N U M B E R D A T E R E V I S E D B Y D E S C R I P T I O N D R A W I N G S P R O V I D E D B Y : DATE: R i v e r B e n d D r a f t i n g a n d D e s i g n E l i s e S h u r t l i f f 2 0 8 -5 5 7 -3 6 2 1 E l i s e @ r i v e r b e n d h o u s e p l a n s .c o m Foundation Plan 11/26/2019 8' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP F l o o r J o i s t D i r e c t i o n 10 CFM Fresh Air Smoke Detector Smoke Detector 3' clearance in front of Furnace Seismic Straps around WH 9' Foundation Walls Family Room 10 CFM Fresh Air Triple Car Garage 4" Concrete Slab Slope Conc. Floor to drain to garage Floor 10 CFM Fresh Air Smoke Detector 10 CFM Fresh Air Smoke Detector 10 CFM Fresh Air Smoke Detector T W e b b C o n s t r u c t i o n P i n e B r o o k E s t a t e s D i v . 2 , B l o c k 6 , L o t 1 4 Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper Floor Joist Direction cut 3' for Door opening with Reg Blocking cut 3' for Door opening with Reg Blocking General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by Elise Shurtliff. pg 5 Main Floor 1686 s/f Basement 1758 s/f Garage 1053 s/f total 4497 s/f cut 6' for Door opening with Reg Blocking DN SB44 B 2 4 R S B 2 4 R B 2 4 R S B 2 4 R B 2 4 R B24R B 2 4 R B 2 4 R R B 3 6 B 2 4 R B 2 4 R S B 3 6 B 2 4 R SB44 B 2 4 R S B 2 4 R B 2 4 R S B 2 4 R B 2 4 R B24R B 2 4 R B 2 4 R R B 3 6 B 2 4 R B 2 4 R S B 3 6 B 2 4 R W 2 4 3 6 R W 2 4 3 6 R W 2 4 3 6 R 4050RS 3060DH 3060DH 3060DH 2 6 6 8 3060DH 3060DH 4040RS 3068 2 6 6 8 2668 2868 2 6 6 8 18080 3 0 6 8 4040RS 3050DH 3050DH 10080 2626FX2626FX 1268FX306851016FX1268FX 5050FX 3 0 6 8 2668 3068 4068 4068 3068 1 5 6 8 3 0 6 8 1 5 6 8 4 0 4 0 D H 3 0 6 8 6060 3068 UP2'-2"5'1'-10" 7 ' 5 '-6 " 2' 2' 4 5 ' 5 ' 5 '-8 " 3 '-6 " 1 2 ' 1 2 '-6 7 /8 " 3 '-6 " 3 '-6 " 2'-6" 24'-6" 6'-6"6'-6" 12'-11" 10'-5"25'-11" 13' 13' 14'-5" 5'-4"3'-4"15'-10" 11'-8" 3'-4"3'-10" 16'-10" 4'-6" 3'-4"3'-4"5'-1"5'-1" 12' 6'6' 79'-4" 2 '-1 " 2 '-4 1 /2 " 1 2 '-1 0 " 6 '-0 1 /2 " 6 '-5 " 12'7'-7"10'-6" 5'-3"5'-3" 3'-5 1/2" 6 '-6 1 /2 " 10'-11 15/16"12'-3" 1 3 '-3 " 13'-3 1/8" 28'-8 3/4" 6 ' 9 '9 ' 3'3' 3 '-2 " 5 '-6 " 1 '-8 " 81'-4 1/16" 2' 5 '-9 " 3 2 '-3 " 7 ' 4 5 ' 3 '-6 " 5 ' 2 5 '-2 " 2 '-2 " 4 5 ' 5 '-8 " 7 ' 81'-4 1/16" 2' 6'-5"5'-6" 8'-0" X 11'-0" 8'-5" X 11'-5" 37'-10" X 23'-5" 1686 SQ FT GARAGE OPEN BELOW LIVING AREA DECK B r a c e d W a l l P a n e l H2 H2 H2 1st Floor R E V I S I O N T A B L E N U M B E R D A T E R E V I S E D B Y D E S C R I P T I O N D R A W I N G S P R O V I D E D B Y : DATE: R i v e r B e n d D r a f t i n g a n d D e s i g n E l i s e S h u r t l i f f 2 0 8 -5 5 7 -3 6 2 1 E l i s e @ r i v e r b e n d h o u s e p l a n s .c o m 8' Main Walls, 10' Entry and Living Room 9' Basement Foundation Walls Garage to Match TYP Main Floor 11/26/2019 10 CFM Fresh Air Smoke Detector 8' Tray Ceiling 10 CFM Fresh Air Smoke Detector 10 CFM Fresh Air Smoke Detector Main Floor 1686 s/f Basement 1758 s/f Garage 1053 s/f total 4497 s/f Smoke Detector/ carbon monoxide detector 50 CFM 50 CFM 50 CFM Contractor to locate exact location of req. 22"x30" Attic Access point Min 30" vertical Head Room Clearance T W e b b C o n s t r u c t i o n P i n e B r o o k E s t a t e s D i v . 2 , B l o c k 6 , L o t 1 4 Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by Elise Shurtliff. 10' Ceiling 8' Ceiling 8' Ceiling 100 CFM Posts for Covered Patio (2) 2x10 for portal framing refer to page 8 figure 1 (2) 2x10 for portal framing refer to page 8 figure 1 H1 - STHD 14 H2 - RJSTHD 14 H1H1 H1 H1 H1 H1 H1 H1 H1 Pg 6 Smoke Detector/ carbon monoxide detector DN SB44 B24R SB24R B24R SB24R B24R B24R B24R B24R RB36 B24R B24R SB36 B24R SB44 B24R SB24R B24R SB24R B24R B24R B24R B24R RB36 B24R B24R SB36 B24R W2436RW2436R W2436R 4050RS 3060DH 3060DH 3060DH 2668 3060DH 3060DH 4040RS 4040RS 3068 2668 2668 2868 2668 18080 3050DH 3050DH 10080 2626FX2626FX 1268FX306851016FX1268FX 5050FX 3068 2668 3068 4068 4068 3068 1568 3068 15684040DH 3068 3068 UP 6' 133'-0 3/8" 2 6 7 ' - 2 3 / 8 " 2 1 7 ' - 4 7 / 8 " 106'-8 1/8" 6 ' 5 ' 3 0 '4 4 '-8 1 3 /1 6 " 7 5 ' - 0 9 / 1 6 " 8 9'-2 1 5/ 1 6 " 1 4 8 ' - 1 1 / 2 " 1 6 5 '-8 7 /1 6 " 8'-0" X 11'-0" 8'-5" X 11'-5" 37'-10" X 23'-5" 1686 SQ FT GARAGE OPEN BELOW LIVING AREA DECK Mow Strip Sidewalk 1st Floor R E V I S I O N T A B L E N U M B E R D A T E R E V I S E D B Y D E S C R I P T I O N D R A W I N G S P R O V I D E D B Y : DATE: R i v e r B e n d D r a f t i n g a n d D e s i g n E l i s e S h u r t l i f f 2 0 8 -5 5 7 -3 6 2 1 E l i s e @ r i v e r b e n d h o u s e p l a n s .c o m 11/26/2019Plot Plan Scale: 1/32" =1'-0" 11" x 17" paper Scale: 1/16"=1'-0" 24" x 36" paper T W e b b C o n s t r u c t i o n P i n e B r o o k E s t a t e s D i v . 2 , B l o c k 6 , L o t 1 4 Pine Brook Estates Division 2, Block 6, Lot 14 Building Parcel Madison County, Idaho General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by Elise Shurtliff. N o r t h Pg 7 2 9 ' 8 " 9 ' 1 ' 1 0 ' 6 '-1 " 8 " 9 ' 1 ' 8 ' 1 0 '-4 " 8 " 4 ' 1 ' 10" 7 " 10'-11" 1 9 '-9 1 /2 " R E V I S I O N T A B L E N U M B E R D A T E R E V I S E D B Y D E S C R I P T I O N Roof System: 2015 IRC Code Architectural Grade, 25 year Asphalt Shingles over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 6:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2015 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall D R A W I N G S P R O V I D E D B Y : Stair System: 2015 IRC R106, R302.7, 311.7.2, R311.7.5, R311.7.8 Eq Stair risers 7 3/3" Max height Eq Stair treads 10" Min depth over (3) 11.5" MIN Stair Stringers securely mounted to framing with Cont. Handrail System mounted 36" above stair plane with Handrail return to wall with a min 6'-8" Head clearance above stair plane with all other Railing system to be a min 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 1/2" gypsum board under stairs DATE: R i v e r B e n d D r a f t i n g a n d D e s i g n E l i s e S h u r t l i f f 2 0 8 -5 5 7 -3 6 2 1 E l i s e @ r i v e r b e n d h o u s e p l a n s .c o m 11/26/2019 A Soffit System: 2015 IRC code 2x6 Facia Board with style "D" Metal Drip Edge with 3/8" soffit Sheeting with 3" Continuous Soffit Venting with add'l 2x4 support as required B Exterior Walls: 2015 IRC code R602.10.1 A braced wall panel shall begin within 10 ft from each end of a braced wall line. The distance between adjacent edges of braced wal panels along a braced wall line shall not be greater than 20 ft. 2015 IRC code R106.1 Vinyl Siding and Brick over Weather Resistive Barrier 7/16" APA OSB & Nailing Pattern 6" - edge 12" - field 2x6 Stud framed @24" O.C. UNO with (2) 2x6 Top Plates with (1) 2x6 Bottom Plate with min R-21 Bottom Insulation with 1/2" Sheetrock Inside Occupancy separation between house, attic, and garage 2015 IRC, Section R106 and R308.4.5 Taped Prep'd for Interior finishes C Interior Walls: 2015 IRC COde 2x4 Stud framed @ 24" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides Taped Prep'd For Interior Finishes D Floor System: 2015 IRC Code 3/4" T&G Sub-floor Glued and Nailed over 11-7/8 TJI Engineered Floor Joist Series, Placement, and O.C Spacing as determined & indicated on TJXpert Layout (Version 6.0 or later) connected to Rim Joist, spliced using gal. metal ties not less than .058" x 1.5" wide fastened w/6 16d nails ea. side over 1/2" Sheetrock on Ceiling side Taped and Prep'd for Interior finishes E Basement Furring: 2x4 Stud Framed @24" O.C. with Baring Walls @ 16" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with R-13 Batt Insulation with 6-Mill Poly Vapor Barrier with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes F Foundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1/2" Anchor Bolts @72" O.C. 10" Long, 7" Embedded Max 12" from all Corners or Splices Concrete wall 8' and under (1) Horizontal Rebar in top 12" and one at mid height 8'1" TO 9'6" (1) Horizontal Rebar in top 12" and one bar at each third point Min (2) Anchor Bolts per Sill Plate w/nut & ROUND Plate Washer 2 1/20 x 1/4" Min. for each Bolt over Concrete Foundation Wall Consistent w/2015 IRC R401-403 with Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/2015 IRC Section R106.1 over Undisturbed Soil G Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq ft 7 Sill height no higher than 44" above FFL Window Wells provide a net clear of 9 sq ft w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps Ladder or Steps 12"- width Inside, 3" from walls, Spaced no more than 18" O.C J Cross Section Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fastners for Preservative treated wood Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasterners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Ventilation 2015 IRC, Section R408.1, R408.2, and R408.3 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 300 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. A B C D E F G J T W e b b C o n s t r u c t i o n P i n e B r o o k E s t a t e s D i v . 2 , B l o c k 6 , L o t 1 4 Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by Elise Shurtliff. Figure R602.10.6.2 Alternate Braced Wall Panel Garage Portal Design Figure 1 Pg 8