Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00192 - 355 Lemmon Ln, Rigby - SFRPermit Inspection Summary Permit Status of (Expired) as of Report Date: 11/27/2019 4:07 pm Permit Details Permit Number: 13-00192 355 Lemmon Ln, Rigby - SFR 355 LEMMON LANE, RIGBY Single Family Residence Rigby Permit Issued Date: 08/12/2013 Permit Inspection Statistics 23Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 65.22% Permit Inspection History *Refer to Individual Inspection Report for more Details 08/12/2013PassTed DyeFooting Inspection 08/12/2013PassTed DyeFoundation Inspection 09/20/2013N/ADon AllenPlumbing Underground Inspection 12/06/2013PassDon AllenHVAC Rough-in 12/10/2013N/ADon AllenRadon-Ground Inspection 01/09/2014PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-slip coupling required for RMP.Inspector Comments: 01/16/2014PassBret StoddardElectrical Rough-in Approved for cover in all 4 townhomes-only one ticket was written for all.Inspector Comments: Building Inspection Type 9/3/13 TD: Sheeting - missed nailing of sheeting. -Braced wall blocking missing and nailings of sheeting to them. -Add trimmer sunder garage header. **All marked with green paint. -Anchor bolt missing in garage by garage door. -Anchor bolt missing washer and nut in garage. Inspector Comments: 09/03/2013PassTed DyeSheeting 9/3/13 TD: Sheeting - some sheeting has staples missing stuls. -Add trimmer & anchor bolts/both sides/ add 2 trimmer on east side. Braced wall blocking missing and they would also need sheeting stapled to them. *All areas marked in green paint. Inspector Comments: 09/10/2013FailTed DyeSheeting 13-00191-192 braced wall panels in garage missed braced wall on northwest corner up stairs missed 13-00193 Inspector Comments: 02/27/2014PassTed DyeInsulation Inspection 03/04/2014FailTed DyeFraming/Structure Inspection studs needed under girders joist hangers needed on garage trusses Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 13-00192 355 Lemmon Ln, Rigby - SFR 355 LEMMON LANE, RIGBY Single Family Residence Rigby Permit Status of (Expired) as of Report Date: 11/27/2019 4:07 pm Permit Inspection Summary 03/05/2014PassTed DyeFraming/Structure Inspection Made necessary correctionsInspector Comments: 03/25/2014PassTed DyeSheetrock/Drywall Inspection Screw patterns good firerock in proper locations Inspector Comments: 11/19/2014FailTed DyeResidential Building Final 11/25/2014PassTed DyeSheeting sheeting passed off with framing inspectionInspector Comments: 11/25/2014FailTed DyeResidential Building Final 11/26/2014PassTed DyeResidential Building Final Electrical Inspection Type 11/10/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Mechanical Inspection Type 11/21/2014FailDon AllenHVAC Final Inspection furnace has a drip comming out of the to exhaust vent cover gril needs to be installed at the top of stairs Inspector Comments: 11/26/2014PassDon AllenHVAC Final Inspection Plumbing Inspection Type 12/10/2013PassSAUREY AMANDAPlumbing Rough-in 11/21/2014FailDon AllenPlumbing Final Inspection drain on water heater pan needs to be ran to the floor drain floor drain needs cover put on Inspector Comments: 11/26/2014PassDon AllenPlumbing Final Inspection Page 2 of 2