HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00191 - 353 Lemmon Ln, Rigby - SFRPermit
Inspection
Summary
Permit Status of (Expired) as of Report Date: 11/27/2019 3:56 pm
Permit Details Permit Number: 13-00191
353 Lemmon Ln - SFR
353 LEMMON LN, RIGBY
Single Family Residence Rigby
Permit Issued Date: 07/02/2013
Permit Inspection Statistics
22Total Inspections Completed:
14Total Inspections Passed:
Inspection Pass Rate: 63.64%
Permit Inspection History *Refer to Individual Inspection Report for more Details
07/08/2013PassTed DyeFooting Inspection
08/12/2013PassTed DyeFoundation Inspection
09/10/2013N/ATed DyeRadon-Ground Inspection
12/06/2013PassDon AllenHVAC Rough-in
12/06/2013N/ADon AllenPlumbing Underground Inspection
01/09/2014PassBret StoddardElectrical Service Inspection
Approved to be energized for permanent power-slip coupling required for RMP.Inspector Comments:
01/16/2014PassBret StoddardElectrical Rough-in
Approved for cover in all 4 townhomes-only one ticket was written for all.Inspector Comments:
Building Inspection Type
09/03/2013FailTed DyeSheeting
-Some sheeting has staples missing studs.
-Add trimmer along existing one in garage door/staple.
-Braced wall blkcing missing and they will also need sheeting stapled to them.
-Nuts missing on anchor bolts by garage door.
-Some sheeting has been missed nailing.
Braced wall blocking missing and will also need nailing.
*All areadrs makred with green paint.
Inspector Comments:
09/10/2013FailTed DyeSheeting
13-00191-192
braced wall panels in garage missed
braced wall on northwest corner up stairs missed 13-00193
Inspector Comments:
02/27/2014PassTed DyeInsulation Inspection
studs needed girders
joist hangers needed on garage trusses
Inspector Comments:
03/04/2014FailTed DyeFraming/Structure Inspection
-hurricane clips needed on garage trusses
-lateral bracing needed on main trusses
-add insulation to cavity's disturbed when adding trimmers under girder truss's
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 13-00191
353 Lemmon Ln - SFR
353 LEMMON LN, RIGBY
Single Family Residence Rigby
Permit Status of (Expired) as of Report Date: 11/27/2019 3:56 pm
Permit
Inspection
Summary
03/05/2014PassTed DyeFraming/Structure Inspection
Made necessary correctionsInspector Comments:
03/25/2014PassTed DyeSheetrock/Drywall Inspection
Screw patterns good
firerock in proper locations
Inspector Comments:
11/19/2014FailTed DyeResidential Building Final
Please correct items and call for a reinspect.
Thank you.
Inspector Comments:
11/25/2014PassTed DyeSheeting
11/26/2014PassTed DyeResidential Building Final
Electrical Inspection Type
11/10/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Mechanical Inspection Type
11/21/2014FailDon AllenHVAC Final Inspection
need to hook up the exhaust on the furnace.Inspector Comments:
11/26/2014PassDon AllenHVAC Final Inspection
All good for the c/oInspector Comments:
Plumbing Inspection Type
12/10/2013PassDon AllenPlumbing Rough-in
Good to cover the rough inInspector Comments:
11/21/2014FailDon AllenPlumbing Final Inspection
neeed to run the drain from the water heater pan to the drainInspector Comments:
11/26/2014PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments:
Page 2 of 2