HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00190 - 351 Lemmon Ln, Rigby - SFRPermit Inspection Summary Permit Status of (Expired) as of Report Date: 11/27/2019 3:21 pm Permit Details Permit Number: 13-00190 351 Lemmon Ln, Rigby - SFR 351 LEMMON LN, RIGBY Single Family Residence Rigby Permit Issued Date: 07/02/2013 Permit Inspection Statistics 23Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 69.57% Permit Inspection History *Refer to Individual Inspection Report for more Details 07/08/2013PassTed DyeFooting Inspection 07/19/2013PassQuinton OwensFoundation Inspection Garage foundation only. Running late, called to check pour time and was told it would be about 3pm. Arrived at 3 and foundations were completely poured. Viewed photos of rebar emailed on 7-19. approved, QO. Inspector Comments: 08/12/2013N/ATed DyeRadon-Ground Inspection 09/18/2013PassDon AllenPlumbing Underground Inspection 12/06/2013FailDon AllenHVAC Rough-in All good on the rough in Gas presser held at 20lb Inspector Comments: 12/06/2013PassDon AllenHVAC Rough-in 12/06/2013PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 01/09/2014PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-slip coupling required for RMP.Inspector Comments: 01/16/2014PassBret StoddardElectrical Rough-in Approved for cover in all 4 townhomes-only one ticket was written for all.Inspector Comments: 02/27/2014FailTed DyeFraming/Structure Inspection -joist hangers missing on both sides of trusses in garage -studs missing under 1 side of girder truss Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 13-00190 351 Lemmon Ln, Rigby - SFR 351 LEMMON LN, RIGBY Single Family Residence Rigby Permit Status of (Expired) as of Report Date: 11/27/2019 3:21 pm Permit Inspection Summary Building Inspection Type 09/10/2013FailTed DyeSheeting 13-00191-192 braced wall panels in garage missed braced wall on northwest corner up stairs missed 13-00193 Inspector Comments: 02/27/2014PassTed DyeInsulation Inspection 03/05/2014PassTed DyeFraming/Structure Inspection Necessary Corrections MadeInspector Comments: 03/24/2014PassTed DyeSheetrock/Drywall Inspection screw patterns good 5/8" fire code drywall on separation walls and on ceilings Inspector Comments: 11/19/2014FailTed DyeResidential Building Final Please correct items and call for a reinspect. Thank you Inspector Comments: 11/25/2014PassTed DyeSheeting 11/25/2014PassTed DyeResidential Building Final This permit was marked s passed but still has items that need to be completed. Sorry for the error Inspector Comments: 11/26/2014PassTed DyeResidential Building Final Electrical Inspection Type 11/10/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Mechanical Inspection Type 11/21/2014FailDon AllenHVAC Final Inspection All 3 apt. need the discharge covers put on the out side of the buildingInspector Comments: 11/26/2014PassDon AllenHVAC Final Inspection All good for the c/oInspector Comments: Plumbing Inspection Type 11/21/2014FailDon AllenPlumbing Final Inspection drain on water heater pan needs to be ran to the floor drainInspector Comments: 11/26/2014PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: Page 2 of 2