HomeMy WebLinkAboutINPSECTION SUMMARY - 13-00165 - 366 Grand Loop - AvantguardPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/26/2019 12:49 pm Permit Details Permit Number: 13-00165 366 Grand Loop - Avantguard 366 Grand Loop New Commercial Building Permit Issued Date: 07/12/2013 Permit Inspection Statistics 31Total Inspections Completed: 25Total Inspections Passed: Inspection Pass Rate: 80.65% Permit Inspection History *Refer to Individual Inspection Report for more Details 06/07/2013PassQuinton OwensFooting Inspection 06/10/2013PassQuinton OwensFoundation Inspection Ufer ground not in at inspection, but will be added as soon as location is found.Inspector Comments: 07/17/2013N/ATed DyeRadon-Ground Inspection 07/19/2013PassDon AllenPlumbing Underground Inspection 07/19/2013PassDon AllenPlumbing Water 07/19/2013PassDon AllenPlumbing Sewer 08/30/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection. Inspector Comments: 08/30/2013PassBret StoddardElectrical Rough-in Approved for cover-south portion, north portion not finished. Inspected the electrical service on the rough-in inspection. Inspector Comments: 08/30/2013PassQuinton OwensFraming/Structure Inspection 09/03/2013N/AQuinton OwensFire Underground Inspection 09/03/2013N/AQuinton OwensFire Sprinkler Rough-in 09/03/2013PassTed DyeSheeting nail patterns good in areas able to check all sheets nailed to braced wall panel spec's Inspector Comments: 09/04/2013FailQuinton OwensInsulation Inspection Ducts insulated with R-8. Blown fiberglass in walls. Doors/windows sealed. vent baffles installed. WINDOW U-FACTOR? LABELS REMOVED. Inspector Comments: 09/05/2013PassBret StoddardFire Alarm Rough-in Approved for cover-fire alarm wiring only.Inspector Comments: 09/18/2013PassQuinton OwensHVAC Rough-in 09/20/2013PassQuinton OwensSheetrock/Drywall Inspection penetrations in 1 hour rated ceilings not protected. (Fire separation not required by code) Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 13-00165 366 Grand Loop - Avantguard 366 Grand Loop New Commercial Building Permit Status of (Open) as of Report Date: 11/26/2019 12:49 pm Permit Inspection Summary 09/24/2013PassDon AllenPlumbing Rough-in 11/13/2013PassQuinton OwensSuspending Ceiling Inspection Large room ceiling grid lateral bracing: 8' o.c. by 12' o.c. (12x12 req'd) Supply vent above grid (west of server room)? Penetrations still not protected in rated ceilings. Inspector Comments: 11/14/2013PassBret StoddardElectrical Rough-in Approved to install ceiling tiles for lighting seismic wiring, must leave open tiles that have junction boxes above them. Above ceilings is considered a plenum because return air registers are not ducted, they are going to duct them as per DAFAB, if they don't the cabling must be plenum rated. Will inspect above the ceiling tiles on the final inspection. Inspector Comments: 11/21/2013PassBret StoddardFire Alarm Final Inspection Approved for a final and C.O.-24 hour 5 minute test-12:58PM 11/20 AC loss-11/21/13 AC restored at 1:05 PM, witnessed all notification and initiating device operation, fire department was called-verified the monitoring, HVAC units are 1500 CFM as per Mike with DAFAB construction, report in file-emailed, plan is above fire alarm panel for fire department. Inspector Comments: 12/03/2013PassQuinton OwensHVAC Final Inspection Ducts penetrating ceilings to be rated per plan do not have fire dampers (No fire separation required by code). HVAC approved with this exception, but will need reinspection if 1 hr separation to be approved. Inspector Comments: 12/03/2013FailQuinton OwensBuilding Final Address numbers to be visible from street. HC parking identification signs not installed. Ceilings constructed as 1 hr fire rated ceilings as per plans except not all penetrations have been protected including duct penetrations (condition will be on C.O. unless 1hr separation is completed and inspected) Inspector Comments: 12/06/2013PassQuinton OwensInsulation Inspection 12/09/2013PassQuinton OwensBuilding Final Approved w/ condition: Ceilings not 1 hr fire rated as noted on plans due to unprotected penetrations. (not required by code). Inspector Comments: 12/10/2013PassDale PickeringFire Department Final Inspection 12/10/2013PassNatalie PowellPlanning and Zoning Final Inspection 12/10/2013PassJoel GrayPublic Works Final Inspection 12/10/2013PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: Building Inspection Type 08/31/2017PassQuinton OwensSidewalk Inspection No request made for sidewalk inspection * Public works approved final Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 13-00165 366 Grand Loop - Avantguard 366 Grand Loop New Commercial Building Permit Status of (Open) as of Report Date: 11/26/2019 12:49 pm Permit Inspection Summary Electrical Inspection Type 12/05/2013FailBret StoddardElectrical Final Inspection Server panels(2) need breaker blanks, panels need labeled throughout, time clock below panels need K.O. seal, green wire in transfer switches-spare? or ground?, NM-B exposed in unfinished space in north portion, fire wire needs stapled in north portion, call for a re-inspect when ready. Inspector Comments: 12/09/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O. in south portion, north portion is not finished and NM-B cable is exposed until this portion is completed. Inspector Comments: Page 3 of 3