HomeMy WebLinkAboutFA602 NAC CKT 2 CALCS - 19-00604 - America First Credit Union - RemodelTHIS IS BASED ON 24 VOLT DEVICES ONLY Project Name Date Circuit Number Area Covered Nominal System Voltage Minimum Device Voltage Total Circuit Current Distance from source to 1st device Wire Gauge for balance of circuit Enter current in amps. .150 = 150 ma Device Number Device 1 Device 2 Device 3 Device 4 Device 5 Deivce 6 Device 7 END END END END END END END END END END END END END END END END END Totals Device Current 0.218 0.218 America First Credit Union - Rexburg 11/24/2019 2 Waterflow horn/strobe 0.218 Distance from previous device 20 10 20.4 16 10 Voltage At Device 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 20.3732296 End of Line Voltage Wire Gauge 14 14 Drop from source 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 2.67704000000002E-02 Ohm's Per 1000 3.07 3.07 Percent Drop 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 1.31227450980393E-03 20.3732296 Calculations and allowable voltage drop are based on revised UL 1971 & 464 standards for current and limits. End of Line method uses only the wire guage for the first device to source for calculation Standard Wire Resistance in Ohms per 1000 feet @ 27 C. This circuit is sourced from: Notes: Wire resistance is doubled in the calculations for two wires (Positive and Negative) The voltage calculated to the last device in any method must not be lower then the manufactures listed minimum operating voltage (IE: rated operating voltage16-33 VDC). Device Manufacturer Horn Strobes Model # P2RK 18-14 Awg = Solid Conductors 12-10 Awg = Stranded Conductors 18=7.61 Firelite panel ES-50X System Sensor Candela 110 Point to Point Method CIRCUIT IS WITHIN LIMITS Totals Current 0.218 16=4.73 Current @Rated Voltage 0.218 Distance 10 End of Line Voltage Percent Drop 14=2.92 Voltage Drop 2.67704000000002E-02 20.3732296 1.31227450980393E-03 12=1.83 Device Manufacturer Strobe Only Model # End of Line Method CIRCUIT IS WITHIN LIMITS Totals Current 0.218 10=1.10 Distance 10 End of Line Voltage Percent Drop SYSTEM SENSOR Candela Voltage Drop 0.0133852 20.3866148 6.56137254901961E-04 Current @Rated Voltage