HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00148 & 13-00149 - JSM 9 PlexPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/22/2019 12:24 pm Permit Details Permit Number: 13-00149 JSM 9 Plex 458 W 6th S New Multi-Family Residence Permit Issued Date: 07/08/2013 Permit Inspection Statistics 37Total Inspections Completed: 26Total Inspections Passed: Inspection Pass Rate: 70.27% Permit Inspection History *Refer to Individual Inspection Report for more Details 07/05/2013FailQuinton OwensFraming/Structure Inspection Fireblocking and Firecaulking not done. Separation required at large hole at tub drain. Seal foundation penetrations. Seams on rated ceiling & wall to be taped. Truss bracing not complete. Inspector Comments: 07/05/2013FailQuinton OwensHVAC Rough-in Protect plastic connection between bath fan and exhaust vent with metal and firecaulk. Inspector Comments: 07/08/2013PassBret StoddardElectrical Rough-in 07/08/2013PassDon AllenPlumbing Rough-in 07/08/2013PassTed DyeFooting Inspection 07/08/2013PassTed DyeFoundation Inspection Footings: ufer in place overlaps of rebar good Foundation: rebar good set in center of wall and overlaps good 2 bars in top foot and 18" on center Inspector Comments: 07/09/2013FailQuinton OwensInsulation Inspection All floors Windows not sealed. Bath fans not redone with Fire CAULK AC Line penetrating ceiling also needs Fire Caulk 3rd Floor not done firecaulking plate penetrations (Also Bsmt) Separation under tubs not done at drain. (Main & Upper floor) Inspector Comments: 07/11/2013PassQuinton OwensFraming/Structure Inspection Fire partition penetrations don Framin &Mech rough-in OK OK to drywall Insulation good Blown Cellulose (Walls &flr) Windows V=0.34, Wndws/Drs sealed. Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 13-00149 JSM 9 Plex 458 W 6th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 11/22/2019 12:24 pm Permit Inspection Summary 07/11/2013PassQuinton OwensHVAC Rough-in Fire partition penetrations don Framing &Mech rough-in OK OK to drywall Insulation good Blown Cellulose (Walls &flr) Windows V=0.34, Wndws/Drs sealed. Inspector Comments: 07/12/2013PassBret StoddardElectrical Rough-in 07/15/2013PassDon AllenPlumbing Underground Inspection All good to cover the rough in on the east 3 unitsInspector Comments: 07/15/2013PassDon AllenPlumbing Rough-in Middle three apartments are good to cover.Inspector Comments: 07/16/2013FailDale PickeringFire Sprinkler Rough-in 7/8,QO: 3 East units- Hi-temp silicone caulk not approved. 7/9,QO: Proper firecaulking applied. OK to insulate Inspector Comments: 7/11,QO: Middle 3 units approvedInspector Comments: 07/17/2013PassQuinton OwensHVAC Rough-in 7/17,QO: 3 West units approved for Mech.Inspector Comments: 07/19/2013PassBret StoddardElectrical Rough-in Approved for cover in the west units(3) only-inspected the electrical service on this inspection also. Inspector Comments: 07/19/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection. Inspector Comments: 07/19/2013PassQuinton OwensFraming/Structure Inspection RE-Inspect Was disapproved on inspection ticket but further reinspect paper wasn't found. Needed to move on the permit Multiple holes not fire-caulked between bathrooms (Top & bottom plate) Main flr. Seal top of windows in SW bedroom (main flr) Basement unit between bathrooms and by door to bathroom No Hi-Temp silicone where fiecaulk required (see gas line in basement) Finish top floor w/ Fire Caulk Inspector Comments: 07/22/2013PassQuinton OwensSheetrock/Drywall Inspection West 3 units OK to tape Drywall 5/8" type x on fire partitions (double on ceilings) Action required:1" clearance around B-vent (downstairs)--(by Final) Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 13-00149 JSM 9 Plex 458 W 6th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 11/22/2019 12:24 pm Permit Inspection Summary 07/22/2013PassQuinton OwensSheetrock/Drywall Inspection Middle 3 units Drywall OK to tape OK to hang Drywall in West Apts. Dove Inspector Comments: 7/11,QO: Items on east side units completed. Insulation approved for middle 3 units. Inspector Comments: 07/22/2013PassQuinton OwensInsulation Inspection 7/22,QO: West 3 units approved.Inspector Comments: 7/1,QO: Sheeting - re-nail missed locations marked inside.Inspector Comments: 7/11,QO: Middle 3 units (all floors): Framing approved and penetrations firecaulked. Separation under tubs, done. Inspector Comments: 7/8,QO: Framing 3 east units(all floors)- Ok to insulate exterior walls and floors. FINISH firecaulking interior and separation at tub drain. Hi-temp SILICONE caulk not approved. 7/9,QO: 3 East side units Ok to drywall. Inspector Comments: 7/17,QO:Fail 3 west units- Need approval on cut joist repair. Missing stud in upstairs bath. Finish firecaulking/fireblocking. Inspector Comments: 7/19,QO:Items not done on 3 west units. Hi-temp silicone not approved.Inspector Comments: 7/22,QO:Approved 3 west units for cover.Inspector Comments: 07/25/2013PassQuinton OwensFraming/Structure Inspection 7/25,QO: Repair submitted for cut joist above basement.Inspector Comments: 08/26/2013PassDale PickeringFire Sprinkler Rough-in 08/26/2013FailQuinton OwensHVAC Final Inspection Firecaulk gaps around comb. air vents. 1" clearance around all B-vents.Inspector Comments: 08/26/2013FailQuinton OwensBuilding Final Window well covers adjacent to walking surfaces. Egress ladders in all bsmt bdrm windows. 1hr fire rating under stairs. Apt & Bldg #'s not posted. Firecaulk at ceiling sprinkler in kitchen (102). Grade slope away from bldg. Landing/steps at riser room. Sprinkler heads still covered (301). Patch ceiling in water heater closet (203). Seal floor next to tubs. Inspector Comments: 08/26/2013FailBret StoddardElectrical Final Inspection Bottom west unit kitchen GFCI won't reset, middle unit on main level receptacle in living room reverse polarity, under stair space not wired or sheetrocked, upstairs unit bathroom-switches are together with fan and light-two switches(not code violation just inconsistent), intersystem bonding termination required by phone/TV location outside, A/C units have to large of breaker installed(20A with 15A max), riser room not done with sheetrock, electrical panel and fire alarm panel, call for a re-inspect when ready. Inspector Comments: 08/30/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O. in units and entire building.Inspector Comments: Page 3 of 4 (Continued) Permit Details Permit Number: 13-00149 JSM 9 Plex 458 W 6th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 11/22/2019 12:24 pm Permit Inspection Summary 08/30/2013FailBret StoddardFire Alarm Final Inspection 24 Hour/5 minute test witnessed for FACP not NAC, flow switch test not done, horn strobes upstairs units not working, re-inspect panels, labels, gong, etc. Inspector Comments: 08/30/2013FailQuinton OwensBuilding Final PVC penetration under stairs not properly firecaulked. 102-fireclk around sprinkler in kitchen. Some combustion air vents still with gaps not firecaulked (201, 203,302,303). Tape patched ceiling in WH closet (203). Metal escutcheon in WH closet (301). Weather protection under Fire Riser room door. Inspector Comments: 09/03/2013PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: 09/03/2013PassDale PickeringFire Sprinkler Final Inspection 09/03/2013PassDale PickeringFire Alarm Final Inspection 09/03/2013PassQuinton OwensHVAC Final Inspection 09/23/2013PassDale PickeringFire Alarm Final Inspection 09/23/2013PassDale PickeringFire Department Final Inspection 9/3 flow test 35 sec - Pass, 24 hour test from 9/2 to 9/3 + 5 minutes - Pass, tampers #1 and #2 - Pass, main drain static 75 psi and 55 psi residual, smoke detect (6) - pass, monitoring - pas per madison dispatch @ 1043 Inspector Comments: 10/27/2015N/AQuinton OwensSidewalk Inspection Public sidewalk already existing. No inspection request for sidewalk around building. Inspector Comments: Building Inspection Type 09/03/2013PassQuinton OwensCommercial Building Final Previous items were completed. Inspection not scheduled through permit tech (did as a planned follow up) Inspector Comments: Page 4 of 4