Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00147 - 261 Seagull Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/22/2019 11:56 am Permit Details Permit Number: 13-00147 261 Seagull Dr - SFR 261 Seagull Dr New Single Family Residence Permit Issued Date: 04/30/2013 Permit Inspection Statistics 19Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 78.95% Permit Inspection History *Refer to Individual Inspection Report for more Details 05/01/2013PassTed DyeFooting Inspection 05/10/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-1 box with receptacles installed(2). Inspector Comments: 05/29/2013PassTed DyeFoundation Inspection ufer in place overlaps of rebar good Inspector Comments: 06/06/2013PassBret StoddardElectrical Rough-in 06/11/2013PassDon AllenPlumbing Underground Inspection ground work is all good to coverInspector Comments: 06/11/2013N/ATed DyeRadon-Ground Inspection radon not inspected. was not called for if it was completed..Inspector Comments: 07/01/2013PassDon AllenPlumbing Rough-in All good to cover rough inInspector Comments: 07/01/2013PassDon AllenHVAC Rough-in Allo good to cover the rough inInspector Comments: 07/08/2013FailTed DyeFraming/Structure Inspection Sheeting: missed nailing Location: upper floor, east side, straight east of stairs. Marked with red crayon. Call when corrected. Inspector Comments: 07/08/2013FailTed DyeFraming/Structure Inspection sheeting corrected. Truss A-2 missing lateral bracing. Truss's J on lower area missing mechanical connection as per truss spec's (note 7) Truss's J-A, JB's and J-C missing upper joist hangers Elictrical not done Call when items are corrected Inspector Comments: 07/08/2013PassTed DyeFraming/Structure Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 13-00147 261 Seagull Dr - SFR 261 Seagull Dr New Single Family Residence Permit Status of (Open) as of Report Date: 11/22/2019 11:56 am Permit Inspection Summary 07/08/2013PassTed DyeInsulation Inspection windows and doors are sealed. Walls insulated both house and garage. Vents in place. OK to drywall Inspector Comments: 07/08/2013PassTed DyeSheetrock/Drywall Inspection OK to cover. *****Note: door's from garage to home do not have a 20 min sticker(plate)on it Called and left message Inspector Comments: 07/15/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O.-outside light up high is blanked off, no A/C unit is installed(30A OCPD). Inspector Comments: 07/22/2013PassDon AllenHVAC Final Inspection All good for the c/oInspector Comments: 07/22/2013PassDon AllenPlumbing Final Inspection All good for c/oInspector Comments: 07/23/2013PassTed DyeSidewalk Inspection 07/23/2013FailTed DyeBuilding Final handrail missingInspector Comments: 07/23/2013PassTed DyeBuilding Final Page 2 of 2