HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00137 - 662 Cook St - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/22/2019 8:50 am Permit Details Permit Number: 13-00137 662 Cook St - SFR 662 Cook St New Single Family Residence Permit Issued Date: 04/26/2013 Permit Inspection Statistics 21Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 76.19% Permit Inspection History *Refer to Individual Inspection Report for more Details 04/26/2013PassTed DyeFooting Inspection 04/29/2013PassQuinton OwensFoundation Inspection Vertical #4 rebar 24" o.c., and 5 #4 Horizontal rebar equally spaced as per engineer. City ordinance would also require 5 bars, but with 2 of them in top 12". Inspector Comments: 06/14/2013PassTed DyeSheeting 06/27/2013PassBret StoddardElectrical Rough-in 06/27/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection. Inspector Comments: 06/27/2013FailTed DyeFraming/Structure Inspection Backing for hold down straps to run from bottom plate to header. Tighten nuts on anchor bolts. Truss details do not match installed trusses. Toenail header in basement to TJI's. Bearing walls missing anchor bolts (6' oc). Inspector Comments: 06/28/2013PassDon AllenPlumbing Underground Inspection all good to cover the undergroundInspector Comments: 06/28/2013PassDon AllenHVAC Rough-in all good to cover the rough inInspector Comments: 07/01/2013PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 07/01/2013PassQuinton OwensFraming/Structure Inspection most bracing missing per truss details. Approved at insulation inspection (7-3).Inspector Comments: 07/03/2013PassQuinton OwensInsulation Inspection windows U=.34, walls - blown fiberglass, venting baffles ok, basement walls = R13, Windows/Doors sealed EXCEPT door to cold storage. Inspector Comments: 07/18/2013PassTed DyeSheetrock/Drywall Inspection 09/13/2013PassTed DyeSidewalk Inspection -Approved 6" base or more,of reject material -trunk dome on site -grade brought from neighbors high grade to regular standard grade Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 13-00137 662 Cook St - SFR 662 Cook St New Single Family Residence Permit Status of (Open) as of Report Date: 11/22/2019 8:50 am Permit Inspection Summary 09/24/2013FailBret StoddardElectrical Final Inspection No access for jet tub motor, call for a re-inspect when ready.Inspector Comments: 09/24/2013FailDon AllenPlumbing Final Inspection need to finish the kitchen sink and dish washer need 2 foot of clearance on the main clean out on the out side sewage injector needs to be working water needs to be turned in to the house water heater needs to be vented need access to the motor on the jetted tub Inspector Comments: 09/24/2013FailDon AllenHVAC Final Inspection need to vent the water heaterInspector Comments: 09/25/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O.-unfinished basement and no wiring installed for an A/C unit outside. Inspector Comments: 09/25/2013FailTed DyeBuilding Final -Fire tape garage -Kitchen sink not installed -Back steps unfinished -Smoke detector at bottom of stairs missing -Smoke detector in main living area missing -slope grade away from foundation 6" in the first 10' -jetted tub needs a access door -insulation certificate needed. mount on electrical panel Inspector Comments: 09/25/2013PassTed DyeBuilding Final 10/03/2013PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: 10/03/2013PassDon AllenHVAC Final Inspection All good for the c/oInspector Comments: Page 2 of 2