HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00137 - 662 Cook St - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 11/22/2019 8:50 am
Permit Details Permit Number: 13-00137
662 Cook St - SFR
662 Cook St
New Single Family Residence
Permit Issued Date: 04/26/2013
Permit Inspection Statistics
21Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 76.19%
Permit Inspection History *Refer to Individual Inspection Report for more Details
04/26/2013PassTed DyeFooting Inspection
04/29/2013PassQuinton OwensFoundation Inspection
Vertical #4 rebar 24" o.c., and 5 #4 Horizontal rebar equally spaced as per
engineer. City ordinance would also require 5 bars, but with 2 of them in top 12".
Inspector Comments:
06/14/2013PassTed DyeSheeting
06/27/2013PassBret StoddardElectrical Rough-in
06/27/2013PassBret StoddardElectrical Service Inspection
Approved to be energized for permanent power-inspected the electrical service
on the rough-in inspection.
Inspector Comments:
06/27/2013FailTed DyeFraming/Structure Inspection
Backing for hold down straps to run from bottom plate to header. Tighten nuts
on anchor bolts. Truss details do not match installed trusses. Toenail header in
basement to TJI's. Bearing walls missing anchor bolts (6' oc).
Inspector Comments:
06/28/2013PassDon AllenPlumbing Underground Inspection
all good to cover the undergroundInspector Comments:
06/28/2013PassDon AllenHVAC Rough-in
all good to cover the rough inInspector Comments:
07/01/2013PassDon AllenPlumbing Rough-in
All good to cover the rough inInspector Comments:
07/01/2013PassQuinton OwensFraming/Structure Inspection
most bracing missing per truss details. Approved at insulation inspection (7-3).Inspector Comments:
07/03/2013PassQuinton OwensInsulation Inspection
windows U=.34, walls - blown fiberglass, venting baffles ok, basement walls =
R13, Windows/Doors sealed EXCEPT door to cold storage.
Inspector Comments:
07/18/2013PassTed DyeSheetrock/Drywall Inspection
09/13/2013PassTed DyeSidewalk Inspection
-Approved 6" base or more,of reject material
-trunk dome on site
-grade brought from neighbors high grade to regular standard grade
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 13-00137
662 Cook St - SFR
662 Cook St
New Single Family Residence
Permit Status of (Open) as of Report Date: 11/22/2019 8:50 am
Permit
Inspection
Summary
09/24/2013FailBret StoddardElectrical Final Inspection
No access for jet tub motor, call for a re-inspect when ready.Inspector Comments:
09/24/2013FailDon AllenPlumbing Final Inspection
need to finish the kitchen sink and dish washer
need 2 foot of clearance on the main clean out on the out side
sewage injector needs to be working
water needs to be turned in to the house
water heater needs to be vented
need access to the motor on the jetted tub
Inspector Comments:
09/24/2013FailDon AllenHVAC Final Inspection
need to vent the water heaterInspector Comments:
09/25/2013PassBret StoddardElectrical Final Inspection
Approved for a final and C.O.-unfinished basement and no wiring installed for an
A/C unit outside.
Inspector Comments:
09/25/2013FailTed DyeBuilding Final
-Fire tape garage
-Kitchen sink not installed
-Back steps unfinished
-Smoke detector at bottom of stairs missing
-Smoke detector in main living area missing
-slope grade away from foundation 6" in the first 10'
-jetted tub needs a access door
-insulation certificate needed. mount on electrical panel
Inspector Comments:
09/25/2013PassTed DyeBuilding Final
10/03/2013PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments:
10/03/2013PassDon AllenHVAC Final Inspection
All good for the c/oInspector Comments:
Page 2 of 2