HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00123 - 611 Johnson - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/21/2019 2:24 pm Permit Details Permit Number: 13-00123 611 Johnson - SFR 611 Johnson New Single Family Residence Permit Issued Date: 07/02/2013 Permit Inspection Statistics 20Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 80.00% Permit Inspection History *Refer to Individual Inspection Report for more Details 07/03/2013PassDon AllenRadon-Ground Inspection All good to cover the radonInspector Comments: 07/08/2013PassTed DyeFooting Inspection 07/08/2013PassTed DyeFoundation Inspection 07/31/2013PassDon AllenPlumbing Underground Inspection All good to cover to under groundInspector Comments: 08/07/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection. Inspector Comments: 08/07/2013FailBret StoddardElectrical Rough-in AFCI protection required for all bedroom outlets, master bedroom outlet cannot be on laundry circuit, laundry power can't leave the laundry room, floor receptacle required near stairway, bath receptacles must be on dedicated 20A circuit, romex connector needed for fan in bath(west), call for a re-inspect when ready, inspected the electrical service on the rough-in inspection. Inspector Comments: 08/09/2013PassBret StoddardElectrical Rough-in Approved for cover-unfinished basement-only the one room to the right of the stairs is finished(west). Inspector Comments: 08/09/2013FailTed DyeFraming/Structure Inspection Joist hangers are required on both sides of truss. Nail plate missing, in corner, for sink drain Riser height has a difference of 1" @ top tread; 3/8" allowed Need truss specs & approved drawing on site Sheeting missed nailing marked in red crayon Blocking missed in garage If a fan is planned on in a room, the end of blade to smoke detector is a min of 36" Inspector Comments: 08/13/2013PassTed DyeFraming/Structure Inspection 08/15/2013PassDon AllenPlumbing Rough-in good to cover the rough inInspector Comments: 08/19/2013PassTed DyeInsulation Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 13-00123 611 Johnson - SFR 611 Johnson New Single Family Residence Permit Status of (Open) as of Report Date: 11/21/2019 2:24 pm Permit Inspection Summary 08/21/2013PassTed DyeSheetrock/Drywall Inspection 09/18/2013PassDon AllenHVAC Rough-in 11/05/2013FailBret StoddardElectrical Final Inspection Bedrooms must have AFCI protection-GFCI is not required for bedrooms and that is what is installed, garage door openers must have GFCI protection, floor box in kitchen area for stair rail not done, unfinished basement entirely except west bedroom by stairs, no A/C unit is installed (30A OCPD), call for a re-inspect when done. Inspector Comments: 11/07/2013PassTed DyeSidewalk Inspection 6" plus of compactable fill be sure and compact Inspector Comments: 11/13/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O.-unfinished basement entirely except the west bedroom next to the stairs, no A/C unit installed (30A OCPD). Inspector Comments: 11/15/2013PassDon AllenPlumbing Final Inspection All good for the c/oiInspector Comments: 11/26/2013FailTed DyeBuilding Final -trim on access in garage is not fire rated. you can extend up with rock or with a 1x2 -1 smoke, CO detector combo needed up stairs out side of bedroom and down stairs in mechanical area -Handrail needed on back stairs measuring between 1-1/4 to 2-1/4 is code. -Ladder needed in window well of bedroom. 44" is the max from base to top of window well. -need screen of another 45 degree fitting on furnace exhaust Inspector Comments: 12/05/2013PassTed DyeBuilding Final 12/17/2013PassDon AllenHVAC Final Inspection Page 2 of 2