HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00122 - 225 Pollard - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 11/21/2019 2:09 pm
Permit Details Permit Number: 13-00122
225 Pollard - SFR
225 Pollard
New Single Family Residence
Permit Issued Date: 04/09/2013
Permit Inspection Statistics
20Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 85.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
04/09/2013PassTed DyeFooting Inspection
04/10/2013PassTed DyeFoundation Inspection
overlaps good
bar spacing right
Ufer bar in place, located by electrical service pipes
Inspector Comments:
04/12/2013PassDon AllenPlumbing Underground Inspection
ground work is all good to coverInspector Comments:
04/16/2013PassBret StoddardElectrical Service Inspection
Approved to be energized for permanent power-no receptacles installed.Inspector Comments:
05/03/2013PassTed DyeRadon-Ground Inspection
05/07/2013PassBret StoddardElectrical Rough-in
05/10/2013PassBret StoddardElectrical Rough-in
Approved for cover-partial unfinished basement (by the storage room).Inspector Comments:
05/16/2013PassDon AllenPlumbing Rough-in
rough in looks good can cover the wallsInspector Comments:
06/07/2013PassQuinton OwensHVAC Rough-in
06/10/2013PassTed DyeFraming/Structure Inspection
06/10/2013PassTed DyeInsulation Inspection
06/18/2013FailBret StoddardElectrical Final Inspection
06/19/2013FailQuinton OwensHVAC Final Inspection
1/2 bath exhaust termination location? Elbow termination on furnace exhaustInspector Comments:
06/19/2013FailQuinton OwensHVAC Final Inspection
Half bath exhaust termination? Elbow termination on furnace exhaust pipe
needed to inhibit foreign objects and birds.
Inspector Comments:
06/19/2013PassBret StoddardSheetrock/Drywall Inspection
Page 1 of 2
(Continued)
Permit Details Permit Number: 13-00122
225 Pollard - SFR
225 Pollard
New Single Family Residence
Permit Status of (Open) as of Report Date: 11/21/2019 2:09 pm
Permit
Inspection
Summary
06/19/2013PassBret StoddardElectrical Final Inspection
Approved for a final and C.O.-no A/C unit installed, one room unfinished in the
basement next to the stairs. Notes were not saved in the fail line-GFCI protection
required for the door opener receptacle, A/C unit wire not terminated, j box
needs a blank in the unfinished room in the basement.
Inspector Comments:
06/24/2013PassQuinton OwensHVAC Final Inspection
1/2 bath vent out patio vented soffit.Inspector Comments:
07/10/2013PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments:
09/05/2013PassTed DyeSidewalk Inspection
09/05/2013PassTed DyeBuilding Final
Page 2 of 2