Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00058 - 573 E 4th S - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/18/2019 2:52 pm Permit Details Permit Number: 13-00058 573 E 4th S - SFR 573 E 4th S New Single Family Residence Permit Issued Date: 04/26/2013 Permit Inspection Statistics 21Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 80.95% Permit Inspection History *Refer to Individual Inspection Report for more Details 03/05/2013PassQuinton OwensFooting Inspection 3 #4 rebar cont. in footing. Fix clearance to form on front footing and add support to rebar laying on dirt in front. Inspector Comments: 03/07/2013PassQuinton OwensFoundation Inspection #4 rebar at 2 ft oc each way with 2 in top 12" (4' walls with 2 horiz)Inspector Comments: 03/26/2013PassDon AllenPlumbing Water 03/26/2013PassDon AllenPlumbing Sewer 03/26/2013PassDon AllenPlumbing Underground Inspection 04/25/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-no temporary receptacles installed. Inspector Comments: 04/29/2013N/ATed DyeRadon-Ground Inspection 04/30/2013PassDon AllenHVAC Rough-in all good to cover the rough in gas presser held at 20# Inspector Comments: 04/30/2013FailDon AllenPlumbing Rough-in leak on on the tub in the west main bathroomInspector Comments: 04/30/2013PassBret StoddardElectrical Rough-in Approved for cover.Inspector Comments: 06/25/2013FailBret StoddardElectrical Final Inspection Not completed-call for a re-inspect when ready.Inspector Comments: 06/26/2013PassDon AllenPlumbing Final Inspection 06/27/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O.-cabinet not installed in room upstairs for proper receptacle placement-wrote on wall with spray paint "cabinet". Inspector Comments: 07/01/2013PassDon AllenPlumbing Rough-in Page 1 of 2 (Continued) Permit Details Permit Number: 13-00058 573 E 4th S - SFR 573 E 4th S New Single Family Residence Permit Status of (Open) as of Report Date: 11/18/2019 2:52 pm Permit Inspection Summary 07/16/2013FailTed DyeFraming/Structure Inspection -fire blocking of fur downs in basement -D-2 truss needs stiff backs Inspector Comments: 07/16/2013PassTed DyeFraming/Structure Inspection 07/16/2013PassTed DyeInsulation Inspection 07/16/2013PassTed DyeSheetrock/Drywall Inspection 07/16/2013PassTed DyeSidewalk Inspection 07/16/2013PassTed DyeBuilding Final Mechanical Inspection Type 07/16/2013PassTed DyeHVAC Final Inspection Page 2 of 2