HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00058 - 573 E 4th S - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 11/18/2019 2:52 pm
Permit Details Permit Number: 13-00058
573 E 4th S - SFR
573 E 4th S
New Single Family Residence
Permit Issued Date: 04/26/2013
Permit Inspection Statistics
21Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 80.95%
Permit Inspection History *Refer to Individual Inspection Report for more Details
03/05/2013PassQuinton OwensFooting Inspection
3 #4 rebar cont. in footing. Fix clearance to form on front footing and add
support to rebar laying on dirt in front.
Inspector Comments:
03/07/2013PassQuinton OwensFoundation Inspection
#4 rebar at 2 ft oc each way with 2 in top 12" (4' walls with 2 horiz)Inspector Comments:
03/26/2013PassDon AllenPlumbing Water
03/26/2013PassDon AllenPlumbing Sewer
03/26/2013PassDon AllenPlumbing Underground Inspection
04/25/2013PassBret StoddardElectrical Service Inspection
Approved to be energized for permanent power-no temporary receptacles
installed.
Inspector Comments:
04/29/2013N/ATed DyeRadon-Ground Inspection
04/30/2013PassDon AllenHVAC Rough-in
all good to cover the rough in
gas presser held at 20#
Inspector Comments:
04/30/2013FailDon AllenPlumbing Rough-in
leak on on the tub in the west main bathroomInspector Comments:
04/30/2013PassBret StoddardElectrical Rough-in
Approved for cover.Inspector Comments:
06/25/2013FailBret StoddardElectrical Final Inspection
Not completed-call for a re-inspect when ready.Inspector Comments:
06/26/2013PassDon AllenPlumbing Final Inspection
06/27/2013PassBret StoddardElectrical Final Inspection
Approved for a final and C.O.-cabinet not installed in room upstairs for proper
receptacle placement-wrote on wall with spray paint "cabinet".
Inspector Comments:
07/01/2013PassDon AllenPlumbing Rough-in
Page 1 of 2
(Continued)
Permit Details Permit Number: 13-00058
573 E 4th S - SFR
573 E 4th S
New Single Family Residence
Permit Status of (Open) as of Report Date: 11/18/2019 2:52 pm
Permit
Inspection
Summary
07/16/2013FailTed DyeFraming/Structure Inspection
-fire blocking of fur downs in basement
-D-2 truss needs stiff backs
Inspector Comments:
07/16/2013PassTed DyeFraming/Structure Inspection
07/16/2013PassTed DyeInsulation Inspection
07/16/2013PassTed DyeSheetrock/Drywall Inspection
07/16/2013PassTed DyeSidewalk Inspection
07/16/2013PassTed DyeBuilding Final
Mechanical Inspection Type
07/16/2013PassTed DyeHVAC Final Inspection
Page 2 of 2