HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00068 - 1190 N 9th E - County MechanicalPermit Inspection Summary Permit Status of (Expired) as of Report Date: 11/18/2019 2:12 pm Permit Details Permit Number: 13-00068 1190 N 9th E - County Mechanical 1190 N 9th E New Residential - Mechanical Misc. Permit Issued Date: 07/12/2013 Permit Inspection Statistics 1Total Inspections Completed: 0Total Inspections Passed: Inspection Pass Rate: 0.00% Permit Inspection History *Refer to Individual Inspection Report for more Details 03/18/2013FailQuinton OwensHVAC Rough-in One supply air above garage has R-value of 4.2 - must cover with attic insulation to meet R-6 requirement. B-vent through main floor is in closet - needs clearance protection from combustibles. One exhaust fan in bsmt bath - will need air transfer opening between watercloset and shower area. Seal all new and future penetrations in RA (Plumb & Elect not finished). One supply vent in bsmt is not finished. Supply vent to garage? (see bldg insp for garage insulation requirements). Inspector Comments: Inspections Required HVAC Final Inspection HVAC Rough-in