HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00074 - 650 Tanglewood Dr - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 11/18/2019 1:22 pm
Permit Details Permit Number: 13-00074
650 Tanglewood Dr - SFR
650 Tanglewood Dr
New Single Family Residence
Permit Issued Date: 04/11/2013
Permit Inspection Statistics
17Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 88.24%
Permit Inspection History *Refer to Individual Inspection Report for more Details
03/29/2013FailQuinton OwensFooting Inspection
2 #4 rebar cont. & supported. Dowels being cut at end of inspection. Return visit
found dowels placed without bends. Need engineer's approval or recommended
fix.
Inspector Comments:
04/01/2013PassQuinton OwensFooting Inspection
Fix: Added 3' dowels epoxied into footing between each existing dowel.Inspector Comments:
04/02/2013PassQuinton OwensFoundation Inspection
06/03/2013PassBret StoddardElectrical Rough-in
06/04/2013PassBret StoddardElectrical Service Inspection
Approved to be energized for permanent power-inspected the electrical service
on the rough-in inspection-no seperate ticket was written.
Inspector Comments:
06/05/2013PassQuinton OwensHVAC Rough-in
Mech. rough-in ok (pressure regulator not installed yet). Gas line tested at 71 psi.Inspector Comments:
06/11/2013PassDon AllenPlumbing Underground Inspection
all good to coverInspector Comments:
06/11/2013PassDon AllenPlumbing Rough-in
all good to cover the rough inInspector Comments:
06/17/2013PassQuinton OwensSheetrock/Drywall Inspection
Sheeting: Missed Nails
Staples spacing to far apart
Staples to deep.
sheeting inspecton failed
2nd inspection passed.
Inspector Comments:
07/17/2013PassTed DyeFraming/Structure Inspection
Anchor bolts need tightening OK
Girder truss in S.W. bedroom needs a stud under north side OK
Inspector Comments:
07/17/2013PassTed DyeInsulation Inspection
Insulation OK
OK to cover all but returns to tub window over the tub. Tempered window
needed.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 13-00074
650 Tanglewood Dr - SFR
650 Tanglewood Dr
New Single Family Residence
Permit Status of (Open) as of Report Date: 11/18/2019 1:22 pm
Permit
Inspection
Summary
09/10/2013PassBret StoddardElectrical Final Inspection
Approved for a final and C.O. as per Jane Shaw.Inspector Comments:
09/11/2013PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments:
09/11/2013PassDon AllenHVAC Final Inspection
All good for the c/oInspector Comments:
09/11/2013PassTed DyeSidewalk Inspection
09/11/2013FailTed DyeBuilding Final
ladder needed in one window well
handrail needed on back stairs
Inspector Comments:
09/13/2013PassTed DyeBuilding Final
Page 2 of 2