Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00097 - 2296 W 960 S - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/13/2019 2:38 pm Permit Details Permit Number: 13-00097 2296 W 960 S - SFR 2296 W 960 S New Single Family Residence Permit Issued Date: 04/10/2013 Permit Inspection Statistics 18Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 83.33% Permit Inspection History *Refer to Individual Inspection Report for more Details 04/11/2013PassTed DyeFooting Inspection bars of the ground ufer on east wall all over laps good OK to pour Inspector Comments: 04/11/2013PassTed DyeFoundation Inspection 04/11/2013N/ATed DyeRadon-Ground Inspection 04/19/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-no receptacles installed.Inspector Comments: 04/22/2013PassDon AllenPlumbing Underground Inspection under ground is all good to coverInspector Comments: 05/14/2013FailQuinton OwensHVAC Rough-in 1" min clearance around b-vent at roof sheathing. Finish Kitchen exhaust vent. Need exhaust fan in bath area of mstr bth (No window) Inspector Comments: 05/16/2013PassDon AllenPlumbing Rough-in rough in looks all good can cover the wallsInspector Comments: 05/16/2013PassBret StoddardElectrical Rough-in Approved for cover.Inspector Comments: 05/16/2013PassQuinton OwensHVAC Rough-in add power to new exhaust fan.Inspector Comments: 06/26/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O.-no A/C unit installed(30A OCPD).Inspector Comments: 07/01/2013PassQuinton OwensHVAC Final Inspection 07/01/2013PassQuinton OwensBuilding Final Page 1 of 2 (Continued) Permit Details Permit Number: 13-00097 2296 W 960 S - SFR 2296 W 960 S New Single Family Residence Permit Status of (Open) as of Report Date: 11/13/2019 2:38 pm Permit Inspection Summary 07/18/2013FailTed DyeFraming/Structure Inspection Sheeting: Staple patterns look good braced wall panels done correctly Framing: J-1 truss hangers are missing diaganol nailing A-3, A-2, A-5G and A5G are missing bracing Call when electrition is done Inspector Comments: 07/18/2013PassTed DyeFraming/Structure Inspection All corrections madeInspector Comments: 07/18/2013PassTed DyeInsulation Inspection insulation installation looks good OK to cover Inspector Comments: 07/19/2013PassTed DyeSheetrock/Drywall Inspection 5/8" Fire Code in garage both wall and ceiling 5/8" Fire code also on 2nd floor ceiling Nail patterns look good OK to TAPE Inspector Comments: 09/24/2013PassDon AllenPlumbing Final Inspection 10/07/2013PassTed DyeSidewalk Inspection 6 inches +Inspector Comments: Page 2 of 2