HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00076 - 649 Tanglewood Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/13/2019 8:21 am Permit Details Permit Number: 13-00076 649 Tanglewood Dr - SFR 649 Tanglewood Dr New Single Family Residence Permit Issued Date: 03/29/2013 Permit Inspection Statistics 19Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 84.21% Permit Inspection History *Refer to Individual Inspection Report for more Details 03/29/2013PassTed DyeFooting Inspection 03/29/2013PassTed DyeFoundation Inspection 04/12/2013PassDon AllenPlumbing Underground Inspection all good to cover the ground workInspector Comments: 04/12/2013PassDon AllenRadon-Ground Inspection all good on the ground workInspector Comments: 06/20/2013PassBret StoddardElectrical Rough-in Approved for cover-east room in the basement is unfinished-inspected the electrical service on the rough-in inspection. Inspector Comments: 06/21/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection. Inspector Comments: 07/01/2013PassDon AllenHVAC Rough-in All good to cover the rough in Gas presser held at 20#Inspector Comments: 07/01/2013PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 07/02/2013PassQuinton OwensSheetrock/Drywall Inspection Smk det. on ceiling near bottom of stairs?Inspector Comments: 07/08/2013FailTed DyeFraming/Structure Inspection Sheeting inspection passed Framing inspection Failed Items were: Windows in front bedroom needs header. support exhaust fan hose in north bedroom. tyvec gables. tighten nuts on anchor bolts Inspector Comments: 07/08/2013FailTed DyeFraming/Structure Inspection anchor bolts on house foundation are loose tyvec missing in gables Inspector Comments: 07/08/2013PassTed DyeFraming/Structure Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 13-00076 649 Tanglewood Dr - SFR 649 Tanglewood Dr New Single Family Residence Permit Status of (Open) as of Report Date: 11/13/2019 8:21 am Permit Inspection Summary 07/08/2013PassTed DyeInsulation Inspection 09/26/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O.-east room in the basement is unfinished, no A/C unit is installed(15A OCPD), jet tub has access in the living room through a vent cover. Inspector Comments: 09/30/2013PassTed DyeSidewalk Inspection 09/30/2013FailTed DyeBuilding Final Smoke detector needed at bottom of stairs *** basement finish **** ***unfinished basement Sidewalk was checked with final inspection as noted on ticket. base as measured form side of sidewalk was OK Inspector Comments: 10/03/2013PassDon AllenPlumbing Final Inspection all good for the c/oInspector Comments: All good for the c/oInspector Comments: 10/03/2013PassDon AllenHVAC Final Inspection need to finish the fire place in the basementInspector Comments: Building Inspection Type 10/16/2015PassTed DyeResidential Building Final Page 2 of 2