HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00075 - 638 Tanglewood Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 11/13/2019 7:44 am Permit Details Permit Number: 13-00075 638 Tanglewood Dr - SFR 638 Tanglewood Dr New Single Family Residence Permit Issued Date: 03/27/2013 Permit Inspection Statistics 23Total Inspections Completed: 19Total Inspections Passed: Inspection Pass Rate: 82.61% Permit Inspection History *Refer to Individual Inspection Report for more Details 03/28/2013PassQuinton OwensFooting Inspection Over laps depths of footing good OK to pour Inspector Comments: 03/29/2013PassQuinton OwensFoundation Inspection 06/12/2013PassBret StoddardElectrical Rough-in 06/12/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection-no seperate ticket was written. Inspector Comments: 06/25/2013PassDon AllenPlumbing Underground Inspection under ground all goodInspector Comments: 06/25/2013PassDon AllenHVAC Rough-in HVAC all good to coverInspector Comments: 07/01/2013PassDon AllenPlumbing Rough-in plumbing is all good to coverInspector Comments: 07/08/2013PassTed DyeFraming/Structure Inspection Sheeting inspection complete and was OK Framing inspection was disapproved for lack of lateral bracing on D-6 truss. re-inspected at the insulation inspection and was OK Inspector Comments: 07/08/2013FailTed DyeInsulation Inspection Rim Joist cavities are not filled properley with insulation. Some With no insulation, some with partial, and a lot with improper fit. Inspector Comments: 07/08/2013PassTed DyeInsulation Inspection 07/12/2013FailSAUREY AMANDASheetrock/Drywall Inspection 06/25/13: Drywall interior ok to tape. Closet by main entry not done. Garage not done. Needs to be reinspected. Inspector Comments: 08/12/2013PassBret StoddardElectrical Rough-in Approved for cover-basement finish only.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 13-00075 638 Tanglewood Dr - SFR 638 Tanglewood Dr New Single Family Residence Permit Status of (Open) as of Report Date: 11/13/2019 7:44 am Permit Inspection Summary 08/15/2013PassDon AllenHVAC Rough-in All good to cover the rough in in the basementInspector Comments: 08/15/2013PassDon AllenPlumbing Rough-in good to cover the rough in in the basementInspector Comments: 08/16/2013FailTed DyeFraming/Structure Inspection -2x4 in bathroom has to much cut (notched) out for plumbing -insulation needed in plumbing wall for fire blocking ** call when repaired, and when insulation is replaced. Inspector Comments: 08/16/2013PassTed DyeFraming/Structure Inspection 08/20/2013PassTed DyeSheetrock/Drywall Inspection 10/10/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O.-west room next to the stairs not finished-(by mechanical room), no A/C unit installed (15A OCPD). Inspector Comments: 10/11/2013FailQuinton OwensBuilding Final CO detector needed near south bedroom in basement.Inspector Comments: 10/14/2013PassQuinton OwensBuilding Final 10/15/2013PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: 10/15/2013PassDon AllenHVAC Final Inspection All good for the c/oInspector Comments: 10/15/2015PassNatalie PowellSidewalk Inspection Page 2 of 2