HomeMy WebLinkAboutPLANS - M19-00141 - McBride - 990 River Run - New SFR4" STEP DOWNONTO PORCH
4" STEP DOWNONTO PORCH
12" STEP DOWNINTO GARAGE
F.F.L. OF GARAGE TO BE LOWERED 12" BELOW F.F.L. OF MAIN RESIDENCE.
20
5
221 221
22
1
20
5
205
205
221 221
22
1
220
220
22
0
22
0
220
20
5
205
205
20
5
22
0
22
0
22
0
22
0
220
220 220
223
SL
O
P
E
AS
R
E
Q
'
D
SL
O
P
E
AS
R
E
Q
'
D
SL
O
P
E
AS
R
E
Q
'
D
SLOPEAS REQ'D
SLOPEAS REQ'D
20
5
SI
M
.
220
SIM.
SIM.
220
SIM.
220
SIM.
223
223
SLOPEAS REQ'D
22
0
SI
M
.
24" x 24" x 8" FOOTING
4" CONC. SLAB
4" CONC. SLAB
4" CONC. SLAB
THREE CAR
GARAGE ABOVE
CRAWL-SPACE
20'-0"7'-0"
27'-0"
7'
-
3
"
11
'
-
5
"
11
'
-
5
"
6'
-
1
1
"
37
'
-
0
"
2'-
0
"
39
'
-
0
"
13'-6"24'-10"14'-10"
53'-2"
43
'
-
2
"
3'-
4
"
4'-
4
"
8'-
0
"
3'-
0
"
9'
-
2
"
71
'
-
0
"
15'-2"29'-10"12'-4"
57'-4"
84'-4"
31'-2"
84'-4"
27
'
-
6
"
71
'
-
0
"
4'
-
6
"
11'-8"12'-0"12'-0"9'-10"24'-2"14'-8"
16
'
-
0
"
16
'
-
0
"
10
'
-
8
"
11
'
-
2
"
15
'
-
0
"
7'-
4
"
11
'
-
2
"
15
'
-
0
"
14
'
-
0
"
8'-
0
"
9'-8"21'-2"
12
'
-
6
"
6'-
8
"
10'-10"32'-2"14'-0"
4'-2"
12'-8"12'-0"12'-0"16'-10"
9'-
8
"
15
'
-
4
"
8'-
8
"
24" x 24" x 8" FOOTING
24" x 24" x 8" FOOTING
BLOCK-OUT FOR
GARAGE DOOR
BLOCK-OUT FOR
GARAGE DOOR
BLOCK-OUT FOR
GARAGE DOOR
SCALE:-
1A1.0 CRAWL-SPACE PLAN
1/4" = 1'-0"
2
A3.0
27'-4"
BLOCK-OUT
FOR DOOR
3'-2"3'-10"
TO MEET ALL APPLICABLE CODES AND TYPICAL BUILDING PRACTICES.
4. CONTRACTOR TO PROVIDE WATERPROOFING AS REQ'D
5. CONCRETE SLABS TO BE 4" (3000 psi MIN.), REINFORCED AS PER CODE
ALL APPLICABLE CODES AT SITE.
1. ALL FOOTING SIZES AND LOCATIONS TO BE
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH FLOOR PLAN
VERIFIED BY A LICENSED STRUCTURAL ENGINEER.
PRIOR TO CONSTRUCTION AND MAKE ANY NECESSARY ADJUSTMENTS.
2. CONTRACTOR TO ADAPT PLANS AS REQUIRED TO MEET
SLAB FOUNDATION NOTES:
OR AS DETERMINED BY LICENSED ENGINEER.
FIN. GRADE, SLOPEAWAY FROMBUILDING
221 FTG. DET.
2'-0"
1'-
0
"
MIN.
MI
N
.
AS PER CODE4" CONC. SLAB, REINF.
8"
GROUT
COMPACTED FILLTHOROUGHLY
.006 POLYETHYLENE
MI
N
.
SEEP HOLES AS PER CODE
MASONRY SILL
MASONRY
CONT. REBAR AS PER CODE
8" CONC. BLK., FILLED W/ CONC.
VERT. REINFORCING AS PER CODE
220 FTG. DET.
AS PER CODE4" CONC. SLAB, REINF.
COMPACTED FILLTHOROUGHLY
205 FTG. DET.
1'-4"
1'
-
0
"
WALL FRAMING
.006 POLYETHELENE
STEP DOWN (VERIFY AT SITE)
MIN.
EXTERIOR SHEATHING
EXTEND FOOTING FOR
MASONRY, IF APPLICABLE
MASONRY, IF APPLICABLE
TREATED SILL PLATE
±5"
AS PER CODE4" CONC. SLAB, REINF.
COMPACTED FILLTHOROUGHLY
MI
N
.
INSUL. AS PER CODE
ANCHOR BOLTS AS PER CODE CONT. REBAR AS PER CODE
CONT. REBAR AS PER CODE
DRIVEWAY, SLOPED
223 FTG. DET.
2'-0"
1'
-
0
"
MIN.
MI
N
.
AS PER CODE4" CONC. SLAB, REINF.
8" CONC. BLK., FILLED W/ CONC.
COMPACTED FILLTHOROUGHLY
.006 POLYETHYLENE
VERT. REINFORCING AS PER CODE
1/2" EXPANSION JOINT
REBAR AS PER CODE
AWAY FROM BUILDING
WATER STOP
CONT. REBAR AS PER CODE
FIN. GRADE, SLOPEAWAY FROMBUILDING
2'-0"
1'
-
0
"
MIN.
MI
N
.
EXTERIOR SHEATING
SIDING
AS PER CODE4" CONC. SLAB, REINF.
8"
MORTAR SMEAR
WALL FRAMING
8" CONC. BLK., FILLED W/ CONC.
COMPACTED FILLTHOROUGHLY
CONT. REBAR AS PER CODE
.006 POLYETHELENE
VERT. REINFORCING AS PER CODE
MI
N
.
TREATED SILL PLATE
INSUL. AS PER CODE
ANCHOR BOLTS AS PER CODE
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
A1.0
3068 C.O.
3068 3068
2870 2870
3068
2870 2870
30
6
8
30
6
8
90
8
0
90
8
0
20
3
6
20
3
6
20
3
6
2450 2860 2860
30
8
0
28
6
8
3068
3070 3070 3070
2868
50
6
8
3068
3070 3070 3070
30
8
0
287028702870
2868
26
6
8
2860 2860
286828682868
30
1
0
30
1
0
28
6
0
4068
2680
28
6
8
26
6
8
30
6
8
26
6
8
P
K
T
.
D
R
.
UP
MI
C
R
O
.
MASTER BED
GLASSWALL ANDDOOR
CO
O
K
T
O
P
w
/
V
E
N
T
HO
O
D
A
B
O
V
E
9:12
VAULT
M. BATH
DR
E
S
S
E
R
START VAULT@9'-0" PLATE HT.
M. CLOSET
9:12
VAULT
VAULTED
9' CLG. HT.
UTILITY
9' CLG. HT.
9' CLG. HT.
9' CLG. HT.
10' CLG. HT.
WASHERSPACE
PWD.
ENTRYLOCKERS
STOR. 1
ST
O
R
.
2
THREE CAR
GARAGE
9' CLG. HT.
12'-0" CLG. HT.
PANTRY
12' CLG. HT.
±10'-4" CLG. HT.
10' CLG. HT.
OFFICE
9' CLG. HT.
8" SQ. COLUMN
(TYP.)
9' CLG. HT.
9' CLG. HT.
9' CLG. HT.
9' CLG. HT.
4" STEPDOWN
16" TRANSOM
ABOVE
BEDROOM 4FOYER
BEDROOM 3
±11'-4" CLG. HT.
HALL
BATH 2
60
"
X
3
6
T
U
B
/
SH
O
W
E
R
CLOS.BATH 3
BEDROOM 2
GREAT ROOM
S
E
A
T
RA
I
L
I
N
G
P
E
R
C
O
D
E
BREAKFAST
12" STEPDOWN
KITCHEN
6" WALLEXTERIOR
NOTE: F.F.L. OF GARAGE TO BELOWERED 12" BELOW F.F.L. OF MAINRESIDENCE.
±10'-0" CLG. HT.
REAR PORCH
10' CLG. HT.
EA
T
I
N
G
B
A
R
COUNTERDEPTH REF.
FRONT PORCH
8" WALL
CUSTOM TILEDSHWR.
LI
N
.
SEAT
CLOS.
COUNTER
GLASSWALL ANDDOOR
6" WALL
LINEN
AWNING ABOVE
BU
I
L
T
-
I
N
S
BU
I
L
T
-
I
N
S
9' CLG. HT.
HALL
9' CLG. HT.
OV
E
N
(2)
EQUALRISERS
8'-6" TOP OFOPENING
10
'
C
L
G
.
H
T
.
±10'-0" CLG. HT.
±1
0
'
-
0
"
C
L
G
.
H
T
.
GARAGE DOOR
OPENER
GARAGE DOOR
OPENER
72
"
X
4
2
"
T
U
B
COUNTER
HEIGHTTO BE 36"
DRYERSPACE
LIN.
CUSTOM
TILED
SHWR.
6" WALL
SINK
ICE
DW
10" SQ.COLUMNS
CLOS.
NON-VENTEDGAS LOGS
STAIR DATA:
17 EQUAL RISERS
11" TREADS16" SUBFLOOR
TOTAL RISE 124"
16" TRANSOM ABOVE
OPTIONALOUTDOORKITCHEN
START VAULT@9'-0" PLATE HT.
CLG. JSTS. AS PERSPAN CHARTS
CLG. JSTS. AS PERSPAN CHARTS
2
A3.0
3070
2450
90
8
0
16
"
T
R
A
N
S
O
M
A
B
O
V
E
GARAGE DOOR
OPENER
30
6
8
30
6
8
30
6
8
CO
A
T
CL
O
S
E
T
6'-8"3'-4"3'-4"6'-8"3'-2"3'-10"
20'-0"7'-0"
27'-0"
7'
-
3
"
11
'
-
5
"
11
'
-
5
"
6'
-
1
1
"
4'
-
6
"
10
'
-
4
"
1'-
7
"
3'
-
1
1
"
1'
-
1
1
"
2'-
2
"
2'-
3
"
5'-
4
"
37
'
-
0
"
5'
-
6
"
2'-
0
"
39
'
-
0
"
7'-1"2'-6"4'-9"2'-6"11'-10"2'-6"
3'-10"3'-2"3'-2"4'-2"
5"12'-0"12'-0"5"
5'-4"3'-2"3'-2"3'-2"3'-8"5'-8"5'-11"2'-10"5'-11"
14'-4"24'-2"14'-8"
14'-4"13'-6"24'-10"14'-10"
53'-2"
4'-
4
"
2'-
1
0
"
2'
-
6
"
3'
-
1
"
2'
-
9
"
2'-
4
"
14
'
-
0
"
11
'
-
4
"
5'-
4
"
5'
-
1
0
"
16
'
-
4
"
3'-
4
"
3'-
1
1
"
5"
4'-
4
"
7'-
8
"
4"
8'-
0
"
3'-
0
"
9'
-
2
"
71
'
-
0
"
5'-5"2'-10"5'-1"3'-7"2'-11"
2'-4"
3'-1"2'-10"5'-5"
13'-4"13'-4"6'-6"11'-4"10'-6"
4"9'-9"9'-8"9'-9"4"
15'-2"29'-10"12'-4"
57'-4"
84'-4"
6'-
4
"
16'-10"
31'-2"
84'-4"
4'-4"10'-0"
10'-10"10'-6"9'-6"14'-4"18'-10"
9'-0"2'-2"3'-6"7'-0"5'-0"4'-2"4'-6"5'-6"21'-2"6'-4"7'-6"4'-2"
10'-4"7'-8"
11'-0"2'-0"6'-8"
4'
-
6
"
3'-
0
"
7'-
0
"
8'
-
1
0
"
16
'
-
2
"
7'-
0
"
11
'
-
6
"
10
'
-
1
0
"
5'-
0
"
6'-
8
"
3'-
8
"
9'
-
4
"
6'
-
2
"
10
'
-
0
"
4'-
4
"
3'
-
9
"
5'
-
4
"
3'
-
9
"
4'
-
4
"
12
'
-
0
"
3'-
0
"
21
'
-
6
"
5'
-
4
"
4'-
0
"
5'-
8
"
15
'
-
0
"
7'-
8
"
4"
3'-
1
1
"
5"
7'-
4
"
20
'
-
6
"
32
'
-
0
"
71
'
-
0
"
SCALE:-
1A1.1 MAIN FLOOR PLAN
1/4" = 1'-0"
MIRROR
3'-
4
"
5'-1"5'-5"
13'-0"13'-0"
9' CLG. HT.
2'-4"
6'-8"7'-8"6'-0"
2860 2860
2'-10"
30
1
0
T
R
N
S
M
W
N
D
W
.
5'
-
2
"
5'
-
2
"
EATING BAR
LIN.
2068
2'-0"
5'
-
1
0
"
3'
-
1
0
"
2'-
0
"
5'-
4
"
5'
-
1
0
"
ACCENT BEAMS
ACCENT BEAMS
ACCENT BEAMS
ACCENT BEAMS
MO
M
'
S
D
E
S
K
6'-
8
43
64
"
6'-
8
43
64
"
6'
-
8
43
64
"
BU
T
L
E
R
'
S
PA
N
T
R
Y
12"10"12 FEET
10" or 12"8" or 10"11 FEET 10"8"10 FEET 8"6"9 FEET
4"6"8 FEET
BEAM HEIGHTBEAM WIDTHCEILING HEIGHT
DECORATIVE BEAM SIZES BASED ON CEILING HEIGHT
AREAS:
3118 S.F. HEATED- TOTAL
900 S.F. UNHEATED - BONUS ROOM
239 S.F. UNHEATED - FRONT PORCH
342 S.F. UNHEATED - REAR PORCH
1033 S.F. UNHEATED - THREE CAR GARAGE
41 S.F. UNHEATED - STORAGE 1
47 S.F. UNHEATED - STORAGE 2
2602 S.F. UNHEATED TOTAL
5720 S.F. TOTAL UNDER ROOF
NOTES:
1. ALL DIMENSIONS & SITE CONDITIONS TO BE VERIFIED BY CONTRACTOR PRIOR TO
CONSTRUCTION.2. ALL FINISHES (INTERIOR & EXTERIOR) TO BE VERIFIED WITH OWNER PRIOR TO
CONSTRUCTION.
3. VERIFY ALL DOOR AND WINDOW STYLES AND SIZES WITH OWNER PRIOR TO
CONSTRUCTION. MANUFACTURER TO SUPPLY ALL ROUGH OPENING SIZES.4. CONTRACTOR TO VERIFY ALL CLEARANCES OF ALL DOORS, WINDOWS AND OTHERITEMS THAT ARE CRITICAL, PRIOR TO CONSTRUCTION.5. CONTRACTOR TO ADAPT PLANS AS REQUIRED TO MEET ALL APPLICABLE CODES ATSITE.
6. ALL BEAMS TO BE SIZED BY A LICENSED STRUCTURAL ENGINEER. 7. PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCATED MORE THEN 30 INCHESABOVE THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36 INCHES HORIZONTALLYSHALL HAVE GUARDS NOT LESS THAN 36 INCHES IN HEIGHT. OPEN SIDES OF STAIRS WITHA TOTAL RISE OF MORE THAN 30 INCHES ABOVE THE FLOOR OR GRADE BELOW SHALLHAVE GUARDS NOT LESS THAN 34 INCHES IN HEIGHT MEASURED VERTICALLY FROM THENOSING OF THE TREADS. INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD.IRC 2015, R312.1.1 & R312.1.2
8. M1305.1.3 APPLIANCES IN ATTICS. ATTICS CONTAINING APPLIANCES SHALL BE
PROVIDED WITH AN OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE
ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT NOT LESS THAN 30
INCHES HIGH AND 22 INCHES WIDE AND NOT MORE THAN 20 FEET LONG MEASURED
ALONG THE CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE APPLIANCE.
THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH
CHAPTER 5 NOT LESS THAN 24 INCHES WIDE. A LEVEL SERVICE SPACE AT LEAST 30
INCHES DEEP AND 30 INCHES WIDE SHALL BE PRESENT ALONG ALL SIDES OF THEAPPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS OPENING DIMENSIONSSHALL BE A MINIMUM OF 20 INCHES BY 30 INCHES, AND LARGE ENOUGH TO ALLOWREMOVAL OF THE LARGEST APPLIANCE.EXCEPTIONS:a. THE PASSAGEWAY AND LEVEL SERVICE SPACE ARE NOT REQUIRED WHERE THE
APPLIANCE CAN BE SERVICED AND REMOVED THROUGH THE REQUIRED OPENING.
b. WHERE THE PASSAGEWAY IS UNOBSTRUCTED AND NOT LESS THAN 6 FEET HIGH AND22 INCHES WIDE FOR ITS ENTIRE LENGTH, THE PASSAGEWAY SHALL BE NOT MORE THAN50 FEET LONG.9. APPLIANCE ACCESS FOR INSPECTION SERVICE, REPAIR AND REPLACEMENT.
APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND
REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES,
OR ANY OTHER PIPING OR DUCTS NOT
CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED OR REPLACED.
A LEVEL WORKING SPACE AT LEAST 30 INCHES DEEP AND 30 INCHES WIDE SHALL BE
PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. INSTALLATION
OF ROOM HEATERS SHALL BE PERMITTED WITH AT LEAST AN 18-INCH WORKING SPACE. APLATFORM SHALL NOT BE REQUIRED FOR ROOM HEATERS.
M1305.1.1 FURNACES AND AIR HANDLERS. FURNACES AND AIR HANDLERS WITHIN
COMPARTMENTS OR ALCOVES SHALL HAVE A MINIMUM WORKING SPACE CLEARANCE OF3 INCHES ALONG THE SIDES, BACK AND TOP WITH A TOTAL WIDTH OF THE ENCLOSINGSPACE BEING AT LEAST 12 INCHES WIDER THAN THE FURNACE OR AIR HANDLER.FURNACES HAVING A FIREBOX OPEN TO THE ATMOSPHERE SHALL HAVE AT LEAST A 6-INCH WORKING SPACE ALONG THE FRONT COMBUSTION CHAMBER SIDE. COMBUSTIONAIR OPENINGS AT THE REAR OR SIDE OF THE COMPARTMENT SHALL COMPLY WITH THEREQUIREMENTS OF CHAPTER 17.
EXCEPTION: THIS SECTION SHALL NOT APPLY TO REPLACEMENT APPLIANCES INSTALLEDIN EXISTING COMPARTMENTS AND ALCOVES WHERE THE WORKING SPACE CLEARANCESARE IN ACCORDANCE WITH THE EQUIPMENT OR APPLIANCE MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
10. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THEINSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE.
WINDOW OPENING CONTROL DEVICES COMPLYING WITH ASTM F 2090 SHALL BEPERMITTED FOR USE ON WINDOWS SERVING AS A REQUIRED EMERGENCY ESCAPE AND
RESCUE OPENING. ALL SLEEPING ROOMS TO HAVE AN EXTERIOR ACCESS THROUGH ADOOR OR WINDOW WITH A MINIMUM OF 5.7 SQUARE FEET NET CLEAR OPENING AS PER
IRC 2015 R310.2.1. EXCEPTION: GRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVEA MINIMUM NET CLEAR OPENING OF 5 SQUARE FEET. MAXIMUM SILL HEIGHT TO BE 44
INCHES. MINIMUM NET CLEAR OPENING HEIGHT TO BE 24 INCHES. MINIMUM NET CLEAR
OPENING WIDTH TO BE 20 INCHES.
11. ALL RETURN AIR GRILLS ARE TO BE LOCATED TO COMPLY WITH SECTION M1602 OFTHE IRC 2015.12. ALL SQUARE FOOTAGE MEASUREMENTS ARE APPROXIMATE AND MAY DIFFER FROM
ACTUAL CONSTRUCTED RESIDENCE OR BUILDING.13. FIRE SPRINKLER SYSTEM TO BE DESIGNED AND INSTALLED (IF REQUIRED BY LOCALCODES) AS PER THE IRC 2015 AND BY A LICENSED PROFESSIONAL IN THE AREA OF
CONSTRUCTION.14. ALL BATHROOM EXHAUST VENTS SHALL BE VENTED DIRECTLY TO THE EXTERIOR OFTHE HOME AND NOT INTO THE ATTIC. IRC 2015, M1507.2
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
A1.1
9' CLG. HT.
BONUS ROOM
BAR
CL
O
S
E
T
CL
O
S
E
T
MI
C
R
O
DN
17'-4"
22
'
-
4
"
15
'
-
4
"
2'
-
6
"
2'
-
6
"
7'-
0
"
5'-
1
0
"
10
'
-
8
"
27
'
-
4
"
43
'
-
1
0
"
4'-6"
24'-2"
8'-7"2'-10"5'-11"
2'-8"
2'-4"
17'-4"
24'-2"
27
'
-
6
"
49
'
-
1
0
"
6'-
0
"
49
'
-
1
0
"
8'-
2
"
24
'
-
8
"
10'-8"9'-4"
9'-0"
2'
-
6
"
10'-4"
5'-
1
0
"
19
'
-
0
"
24
2
4
24
2
4
24
2
4
9'
-
8
"
D
O
R
M
E
R
P
L
A
T
E
2860 2860
2456
4'-2"
60
6
8
60
6
8
26
6
8
30
6
8
P
K
T
.
D
R
.
3068
2456
4'-9"2'-6"4'-9"
10'-9"12'-0"10'-9"
STORAGE
SCALE:-
1A1.2 BONUS FLOOR PLAN
1/4" = 1'-0"
10'-6"
24
2
4
24
2
4
9'
-
8
"
D
O
R
M
E
R
P
L
A
T
E
3'-
1
1
"
2'-
6
"
4'-
3
"
BEDROOM 5
9' CLG. HT.
9' CLG. HT.
5'-
1
0
"
5'-
1
0
"
9:
1
2
10'-0" PLATE HT.
14'-0" PLATE HT.17'-4" PLATE HT.14'-0" PLATE HT.
9'-0" PLATE HT.
10'-0" PLATE HT.10'-0" PLATE HT.
12'-0" PLATE HT.
11'-0" PLATE HT.
9'-0" PLATE HT.
9'-0" PLATE HT.
17'-4" PLATE HT.
20
'
-
0
"
P
L
A
T
E
H
T
.
17'-4" PLATE HT.
9'-0" PLATE HT.
12
:
1
2
12
:
1
2
4:
1
2
9:12 9:12
9:12 9:12
4:12
9:
1
2
9:
1
2
12
:
1
2
12
:
1
2
4:12
9:12
9:12
8:12
9:
1
2
9:
1
2
4:12
METAL ROOF
METAL ROOF
METAL ROOF
4"4"
1'-4"
1'-4"
1'-4"
1'
-
4
"
1'
-
4
"
1'
-
4
"
1'
-
4
"
1'-4"
2'-6"
1'-4"
1'-4"1'-4"
1'-
4
"
1'
-
4
"
1'
-
4
"
1'-4"1'-4"
5"
5"
20
'
-
0
"
P
L
A
T
E
H
T
.
4:
1
2
METAL ROOF
2'-6"
5"
5"
4:12
SCALE:-
2A1.2 ROOF PLAN
3/16" = 1'-0"
RISE/ RUN SLOPE
1/12 5°
2/12
3/12
4/12
5/12
6/12
7/12
8/12
9/12
10/12
11/12
12/12
10°
14°
18°
23°
27°
30°
34°
37°
40°
42°
45°
RISE/ RUN SLOPE
1/17 3°
2/17
3/17
4/17
5/17
6/17
7/17
8/17
9/17
10/17
11/17
12/17
7°
10°
13°
16°
19°
22°
25°
28°
30°
33°
35°
ROOF PITCH FACTOR
1.053/12
4/12
5/12
6/12
7/12
8/12
9/12
10/12
11/12
12/12
1.07
1.10
1.14
1.17
1.20
1.25
1.30
1.35
1.40
1.54
1.70
IF COMMON RAFTER ROOF PITCH IS...
THEN HIP/ VALLEYRAFTER ROOF PITCH BECOMES...
14/12
16/12
RAFTER LENGTH CHART
MULTIPY HORIZONTAL SPAN OF MEMBER BY FACTOR.CHOOSE APPROPRIATE FACTOR BY ROOF PITCH.
HIP/ VALLEY CONVERSION
CONVERSION CHART FOR SIMPLE ROOFS ONLY.CHART DOES NOT APPLY FOR DUAL PITCH ROOFS.
(UNINHABITABLE ATTICS WITHOUT STORAGE, LIVE LOAD = 20psf, L/ =240)CEILING JOIST SPANS FOR SOUTHERN PINE SPECIES
SIZE
REFER TO THE INTERNATIONAL RESIDENTIAL CODE, SPAN TABLES.***
2 x 10
NOTES:
2 x 6
2 x 8
2 x 4 8-016.0
19.2
19.2
24.0
12.0
24.0
16.0
12.0
24.0
16.0
19.2
19.2
24.0
16.0
12.0
13-11
16-6
14-9
20-11
12-6
18-1
9-10
17-7
15-3
11-0
7-4
6-7
12-0
13-11
VISUALLY GRADED #2
(MAXIMUM CEILING JOIST SPANS)SOUTHERN PINE
***IF HABITABLE ATTIC SPACE OR STORAGE IS DESIRED,
DEAD LOAD = 10psf
SPACING
12.0
(INCHES)
9-3
(FT. - IN.)
CEILING JOIST SPANS
The above tables are based on the IRC 2015 TABLE R802.4(2)
, L/ =180
BETWEEN BRACING)
SPANS
RAFTER SPANS
(FT. - IN.)
12-11
11-2
10-2
DEAD LOAD = 10psf
(INCHES)
12.0
16.0
19.2
SPACING
RAFTER SPANS FOR SOUTHERN PINE SPECIES
(MAXIMUM RAFTER SPANS
14-2
12-11
16-4
9-2
15-4
13-9
19-5
16-10
11-7
18-1
16-2
22-10
19-10
16.0
19.2
12.0
24.0
19.2
24.0
12.0
16.0
24.0
19.2
24.0
16.0
12.0
2
x
6
2
x
8
2
x
1
2
2
x
1
0
LIVE LOAD=30psf
SIZE
NOTES:
The above tables are based on the IRC 2015 TABLE R802.5.1(3)
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
A1.2
RR
RR
RR
RR
RR
RR
GF
C
I
GF
C
I
S
S
S S S
SS
RR RR
RRRR
SD
S3S3S3
S 3
S 3
S 3
RR
S
RR
GFCIGFCI
GFCI
S
GFCI
RR S S
RR
GFCI GFCI
GFCI220VGFCI
S
RR RR
RR
RR
RR
SD
CM
S4
S 4
S4
WP
GFCI
GFCI
GFCI
GFCI GFCI
GFCI GFCI
GF
C
I
GF
C
I
BREAKER BOX (VERIFY LOCATION AT SITE)
CLG.
PLUG
CLG. PLUG
CLG.
PLUG
ENTRY LOCATIONVERIFY EXTERIOR POWER
RR RR
RR
RR RR
GFCI
GFCI
PENDANT
LIGHTING
S 3
TO ABOVE
RR RR
RR RR
RR
GFCI
SS3
S GFCI
S 3 S
S 3
S 3
S
RR
RR
RR
S
22
0
V
22
0
V
GFCI
GFCI
GFCI
RR
RRRRRR
RR RR
S
S
SSS
RR
S
RR
S
S3
S 3
S
RR RR
RRRR
SDRR
S
SSS
RR RR
RRRR
SSS
SD
S
RR
WP
RRRRSDCM
S
RRRRSSS
RR RR
GFCI GFCI
SS
S
RR RR
GFCI
SS
RR
SS
RR SD
CM
S
SD
RR RR
RRRR
S S S
RR RR RR
RR RR
RR RR RR
OUTLET LOCATIONS W/ OWNER
CONTRACTOR TO VERIFY FLOOR
S4
S4S4
SS
RR RR
RR RR
RR RR
RR RR
WP
WP
GFCI
S S S
WP WP
RR RR RR
SS
S
S
MASTER BED
M.
B
A
T
H
M. CLOSET
UTILITY
PWD.
ENTRY
STOR. 1
THREE CAR
GARAGE
PANTRY
OFFICE
BEDROOM 4
FOYER BEDROOM 3
HALL
BATH 2
CLOS.BATH 3
BEDROOM 2
GREAT ROOM
BREAKFAST REAR PORCH
FRONT PORCH
LI
N
.
CLOS.
HALL
CLOS.
CO
A
T
CL
O
S
E
T
SD
SCALE:-
1A2.0
MAIN FLOOR ELECTRICAL PLAN
1/4" = 1'-0"
SS3
KITCHEN
ST
O
R
.
2
BU
T
L
E
R
'
S
PA
N
T
R
Y
CM
4
3
C5
SD
T
TV
D
DM
RR
WP
ELECTRICAL SYMBOLS LEGEND
SYMBOL DESCRIPTION
AUDIO SPEAKERS
UNDER COUNTER LIGHTING
OVERHANG MOUNTED FLOODLIGHTS
CARBON MONOXIDE DETECTOR
CAT5 NETWORKING JACK (OWNER TO LOCATE)
DOOR ACTIVATED SWITCH
CEILING FAN w/LIGHT
CHANDELIER
DISCONNECTING MEANS.
CONNECTED TO THE LOAD SIDE OF THE HVAC EQUIPMENT
EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE
LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET OF THE
AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE
LOCATION FOR THE SERVICING OF HEATING, AIR CONDITIONING
RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
4. A 125 VOLT, SINGLE PHASE, 15-20 AMPERE RATED
WITH ATTACHED GARAGES.
FIRED APPLIANCES ARE INSTALLED AND IN DWELLING UNITS
OF THE BEDROOMS IN DWELLING UNITS WITHIN WHICH FUEL-
OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY
3. CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE
SHALL BE HARD WIRED WITH A BATTERY BACK UP.
ACTIVATE ALL OF THE ALARMS IN THE UNIT. SMOKE ALARMS
SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL
DWELLING THE ALARM DEVICES SHALL BE INTERCONNECTED IS
SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN A
BASEMENTS AND HABITABLE ATTICS. WHEN MORE THAN ONE
ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS,
LOCATIONS: EACH SLEEPING ROOM, OUTSIDE EACH SEPARATE
2. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
SITE.
1. ALL WORK SHALL COMPLY WITH ALL CODES APPLICABLE AT
ELECTRICAL NOTES:
TRACK LIGHTING (OWNER TO LOCATE)
WALL SCONCE (OWNER TO LOCATE)
CEILING EXHAUST FAN, VENT TO EXTERIOR
THERMOSTAT (CONTRACTOR TO LOCATE)
DOORBELL BUTTON (CONTRACTOR TO LOCATE)
TELEVISION OUTLET (OWNER TO LOCATE)
TELEPHONE OUTLET (OWNER TO LOCATE)
DIMMER SWITCH (OWNER TO LOCATE)
FOUR WAY SWITCH
THREE WAY SWITCH
SWITCH
SMOKE DETECTOR
FLUORESCENT LIGHT
RECESSED CEILING FIXTURE
WALL MOUNTED FLOODLIGHTS
CEILING HUNG FIXTURE
FLOOR OUTLET (OWNER TO LOCATE)
220 VOLT RECEPTACLE
WEATHERPROOF OUTLET
GROUND FAULT PROTECTED OUTLET
110 VOLT OUTLET
CEILING FAN
CEILING EXHAUST FAN w/LIGHT, VENT TO EXT.
WALL MOUNTED LIGHTING FIXTURE
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
A2.0
RRRRSD
RR
S
S
RR RR
RRRR
RRRR
S S
S
GFCI
RR RR
RRRR
SD
S S
S
S 3
S
TO BELOW
BONUS ROOM
STORAGE
SCALE:-
1A3.0 BONUS FLOOR ELECTRICAL PLAN
1/4" = 1'-0"
CM
4
3
C5
SD
T
TV
D
DM
RR
WP
ELECTRICAL SYMBOLS LEGEND
SYMBOL DESCRIPTION
AUDIO SPEAKERS
UNDER COUNTER LIGHTING
OVERHANG MOUNTED FLOODLIGHTS
CARBON MONOXIDE DETECTOR
CAT5 NETWORKING JACK (OWNER TO LOCATE)
DOOR ACTIVATED SWITCH
CEILING FAN w/LIGHT
CHANDELIER
DISCONNECTING MEANS.
CONNECTED TO THE LOAD SIDE OF THE HVAC EQUIPMENT
EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE
LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET OF THE
AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE
LOCATION FOR THE SERVICING OF HEATING, AIR CONDITIONING
RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
4. A 125 VOLT, SINGLE PHASE, 15-20 AMPERE RATED
WITH ATTACHED GARAGES.
FIRED APPLIANCES ARE INSTALLED AND IN DWELLING UNITS
OF THE BEDROOMS IN DWELLING UNITS WITHIN WHICH FUEL-
OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY
3. CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE
SHALL BE HARD WIRED WITH A BATTERY BACK UP.
ACTIVATE ALL OF THE ALARMS IN THE UNIT. SMOKE ALARMS
SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL
DWELLING THE ALARM DEVICES SHALL BE INTERCONNECTED IS
SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN A
BASEMENTS AND HABITABLE ATTICS. WHEN MORE THAN ONE
ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS,
LOCATIONS: EACH SLEEPING ROOM, OUTSIDE EACH SEPARATE
2. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
SITE.
1. ALL WORK SHALL COMPLY WITH ALL CODES APPLICABLE AT
ELECTRICAL NOTES:
TRACK LIGHTING (OWNER TO LOCATE)
WALL SCONCE (OWNER TO LOCATE)
CEILING EXHAUST FAN, VENT TO EXTERIOR
THERMOSTAT (CONTRACTOR TO LOCATE)
DOORBELL BUTTON (CONTRACTOR TO LOCATE)
TELEVISION OUTLET (OWNER TO LOCATE)
TELEPHONE OUTLET (OWNER TO LOCATE)
DIMMER SWITCH (OWNER TO LOCATE)
FOUR WAY SWITCH
THREE WAY SWITCH
SWITCH
SMOKE DETECTOR
FLUORESCENT LIGHT
RECESSED CEILING FIXTURE
WALL MOUNTED FLOODLIGHTS
CEILING HUNG FIXTURE
FLOOR OUTLET (OWNER TO LOCATE)
220 VOLT RECEPTACLE
WEATHERPROOF OUTLET
GROUND FAULT PROTECTED OUTLET
110 VOLT OUTLET
CEILING FAN
CEILING EXHAUST FAN w/LIGHT, VENT TO EXT.
WALL MOUNTED LIGHTING FIXTURE
212
SHINGLES 17'-4" PLATE HEIGHT (DORMER)
9
12
9
12
14'-0" PLATE HEIGHT
FINISHED FLOOR
10'-0" PLATE HEIGHT
11'-0" PLATE HEIGHT
FINISHED FLOOR
GAS LOGS
GREAT
ROOM
VENTLESS
CABINETSCABINETS
VERIFY BRACING AND WIND STRAPPING REQUIREMENTS AT SITE.
OFFICE
10
'
-
0
"
FRONT
PORCH
REAR
PORCH
BM. AS REQ'D(RE: FLOOR PLAN)
BM. AS REQ'D(RE: FLOOR PLAN)
SHINGLES
12
'
-
0
"
10
'
-
0
"
SCALE:-
2A3.0
CROSS SECTION
1/4" = 1'-0"
FOYER
BEYOND
GRADEGRADE
CRAWL-SPACE
AS PER CODE AND TYPICAL BUILDING PRACTICES.
6. ALL LUMBER SIZES AND SPACING TO BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION.
5. ALL BEAMS TO BE SIZED BY A LICENSED STRUCTURAL ENGINEER.
3. CONTRACTOR TO PROVIDE RAFTER BRACING TO MEET APPLICABLE CODES.
2. ALL RIDGE BEAMS, HIP RAFTERS, & VALLEY RAFTERS TO BE 2" x 10",
1. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES AT SITE.
CROSS SECTION NOTES:
4. CONTRACTOR TO THOROUGHLY WATERPROOF ALL EXTERIOR INTERSECTIONS
OR AS REQ'D BY ENGINEER.
7. CONTRACTOR TO PROVIDE ADEQUATE ROOF VENTILATION AS REQ'D. BY CURRENT CODES.
SUPPORT BRACKET AS REQ'D.
KITCHEN KITCHEN
COOKTOP
KITCHEN KITCHEN
MICRO
ICE
OVEN
VENT
REF.(O.T.S.)
DW.(O.T.S.)
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
A3.0
7'
-
0
"
1'-
4
"
9'
-
0
"
2" TRIM
9'-0" PLATE HEIGHT
F.F.L. BONUS ROOM
7'-0" PLATE HEIGHT BONUS RM.
2" TRIM
4" CORNER BOARD (TYP.)WOOD
METAL ROOF
MORTAR SMEAR
BRACKET
SHINGLES
17'-4" DORMER PLATE HT.
F.F.L. MAIN HOUSE
F.F.L. GARAGE
18
'
-
4
"
FINISHED FLOOR
BRICK
WALL LIGHT
WOOD BRACKETSEE DETAIL 504
MORTAR SMEAR
EXPOSED RAFTER TAILS
VERIFY STEPS @ SITEPROVIDE HANDRAILS AS PER CODE
SEE 503
12
12
12
12
12
12
4
12
1'-
0
"
8'
-
0
"
WALL LIGHT
8:12 METAL ROOF
9
12
DETAILFRAMING
CLG. JST.
RAFTER
2'-6"
BOARDAND BATTEN
BOARDAND BATTEN
10
'
-
1
0
"
NOTE: CONTRACTOR TO
PROVIDE ADEQUATE ROOF
VENTILATION AS PER CODE.
8'
-
0
"
8'
-
0
"
8'
-
0
"
2'
-
0
"
MI
N
.
9'-0" PLATE HEIGHT
6'-8" TOP OF WINDOW (TYP.)
SCALE:-
1A4.0
FRONT ELEVATION
1/4" = 1'-0"
2 12
LOUVERED VENT
SHINGLES
WOOD PANEL
17'-4" PLATE HEIGHT (DORMER)
2" TRIM
2" TRIM
MORTAR SMEAR
13
'
-
5
"
R
A
F
T
E
R
B
E
A
R
I
N
G
4" CORNER BOARD (TYP.)
9
12
9
12
9
12
4
12
14'-0" PLATE HEIGHT
9'-
0
"
FINISHED FLOOR
BOARDAND BATTEN
6'-8" TOP OF WINDOW (TYP.)
10'-0" PLATE HEIGHT
9'-0" PLATE HEIGHT
FINISHED FLOOR
VERIFY STEPS @ SITEPROVIDE HANDRAILS AS PER CODE VERIFY STEPS @ SITEPROVIDE HANDRAILS AS PER CODEBRICK
NOTE: CONTRACTOR TO
PROVIDE ADEQUATE ROOF
VENTILATION AS PER CODE.
8'-
0
"
SCALE:-
2A4.0 RIGHT ELEVATION
1/4" = 1'-0"
EXTERIOR ELEVATION NOTES:
1. CONTRACTOR TO VERIFY ALL WINDOW AND DOOR STYLES AND
SIZES WITH OWNER PRIOR TO CONSTRUCTION.
2. PROVIDE STEPS AND GUARD RAILS AS PER CODE BASED ON
SITE CONDITIONS.
3. GROUND LINES SHOWN FOR REFERENCE ONLY AND VARY
DEPENDING ON SITE CONDITIONS.
4. ALL FINISH MATERIALS TO BE VERIFIED WITH OWNER PRIOR TO
CONSTRUCTION.
5. REFER TO TYPICAL WALL DETAIL FOR FRAMING METHODS AND
OTHER MISC. INFORMATION.
6. CONTRACTOR TO PROVIDE ADEQUATE ROOF VENTILATION AS
REQ'D BY CURRENT CODES.
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
A4.0
SHINGLES
SHINGLES
BRACKET
LOUVERED VENT
4" CORNER BOARD (TYP.)
MORTAR SMEAR
10" BAND
2" TRIM10'-0" PLATE HEIGHT
11'-0" PLATE HEIGHT
9'-0" PLATE HEIGHT
9
12
FINISHED FLOOR
6'-8" TOP OF WINDOW (TYP.)
2'-
0
"
MORTAR SMEAR
LOUVERED VENT
VERIFY STEPS @ SITEPROVIDE HANDRAILS AS PER CODE
9
12
4
12
WOOD
10'-0" PLATE HEIGHT
CHANGE IN PITCH 9:12
4:12
CHANGE IN PITCH 9:12
4:12
BOARDAND BATTEN
BOARDAND BATTEN
9
12
BRICK
9
12
12
12
8'
-
0
"
8'
-
0
"
SCALE:-
1A4.1 REAR ELEVATION
1/4" = 1'-0"
20
'
-
0
"
SHINGLES
MORTAR SMEAR
4" CORNER BOARD (TYP.)
9'-0" PLATE HEIGHT
17
'
-
4
"
7'-0" PLATE HEIGHT
F.F.L. BONUS ROOM
9'-8" PLATE HEIGHT DORMER
F.F.L. GARAGE
SHINGLES
WOOD BRACKETSEE DETAIL 504
F.F.L. MAIN HOUSE
6'-
8
"
BOARDAND BATTEN
7'-
0
"
1'-
4
"
9'-
0
"
1'-
0
"
VERIFY STEPS @ SITEPROVIDE HANDRAILS AS PER CODE
8'-
0
"
METAL ROOF
EXPOSED RAFTER TAILS
SCALE:-
2A4.1 LEFT ELEVATION
1/4" = 1'-0"
METAL ROOF
EXTERIOR ELEVATION NOTES:
1. CONTRACTOR TO VERIFY ALL WINDOW AND DOOR STYLES AND
SIZES WITH OWNER PRIOR TO CONSTRUCTION.
2. PROVIDE STEPS AND GUARD RAILS AS PER CODE BASED ON
SITE CONDITIONS.
3. GROUND LINES SHOWN FOR REFERENCE ONLY AND VARY
DEPENDING ON SITE CONDITIONS.
4. ALL FINISH MATERIALS TO BE VERIFIED WITH OWNER PRIOR TO
CONSTRUCTION.
5. REFER TO TYPICAL WALL DETAIL FOR FRAMING METHODS AND
OTHER MISC. INFORMATION.
6. CONTRACTOR TO PROVIDE ADEQUATE ROOF VENTILATION AS
REQ'D BY CURRENT CODES.
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
A4.1
BEAM PER CODE
BEAM PER CODE
BEAM PER CODE
PR
E
-
E
N
G
I
N
E
E
R
E
D
FL
O
O
R
J
O
I
S
T
S
PR
E
-
E
N
G
I
N
E
E
R
E
D
FL
O
O
R
J
O
I
S
T
S
PR
E
-
E
N
G
I
N
E
E
R
E
D
FL
O
O
R
J
O
I
S
T
S
PR
E
-
E
N
G
I
N
E
E
R
E
D
FL
O
O
R
J
O
I
S
T
S
PR
E
-
E
N
G
I
N
E
E
R
E
D
FL
O
O
R
J
O
I
S
T
S
CRAWL-SPACE
SCALE:-
1REF-1
CRAWL-SPACE STRUCTURAL PLAN
1/4" = 1'-0"
FOR REFERENCE USE ONLY
NOTE:-
THIS SHEET IS FOR REFERENCE ONLY. THE CONTENT ON THIS SHEET WAS CREATED BY
THE ORIGINAL DESIGNER OF THIS PLAN. THIS CONTENT HAS BEEN INCLUDED IN THE DRAWINGS
SET TO CONVEY THE INTENT OF THE ORIGINAL DESIGN. NO CHANGES OR UPDATES HAVE BEEN
MADE TO THE CONTENT ON THIS SHEET, THEREFORE IT MAY NOT CORRESPOND WITH THE OTHER
SHEETS IN THIS DRAWING SET. ReDesign HP DOES NOT ENDORSE AND / OR TAKE RESPONSIBILITY
FOR THE CONTENT ON THIS SHEET. IT IS THE RESPONSIBILITY OF THE BUILDER TO ASSURE THAT
ALL WORK IS IN ACCORDANCE WITH THE LATEST EDITION OF ALL APPLICABLE NATIONAL, STATE,
AND LOCAL BUILDING CODES.
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
REF-1
PRE-ENGINEERED FLOOR JOISTS ABOVE
BEAM ABV. AS REQ'D
(FURR BEAM OUT TO 8")
BEAM ABV.AS REQ'D
BEAM ABV.AS REQ'D
BEAM ABV. AS REQ'D
(FURR BEAM OUT TO 10")
BEAM ABV. AS REQ'D
BEAM ABV. AS REQ'D
(BEAM IN ATTIC)
STRUCTURAL BEAM ASREQD. IN ATTIC ABOVE
BEAM ABOVE AS REQD.FOR RAFTER BEARING
BEAM ABOVE AS REQD.FOR RAFTER BEARING
CLG. JSTS. AS PERSPAN CHARTS
CLG. JSTS. AS PERSPAN CHARTS
CLG. JSTS. AS PERSPAN CHARTS CLG. JSTS. AS PERSPAN CHARTS
CLG. JSTS. AS PER
SPAN CHARTS
CLG. JSTS. AS PERSPAN CHARTS
CLG. JSTS. AS PER
SPAN CHARTS
CLG. JSTS. AS PERSPAN CHARTS
CLG. JSTS. AS PERSPAN CHARTS
CLG. JSTS. AS PERSPAN CHARTS
CL
G
.
J
S
T
S
.
A
S
P
E
R
SP
A
N
C
H
A
R
T
S
CL
G
.
J
S
T
S
.
A
S
P
E
R
SP
A
N
C
H
A
R
T
S
CL
G
.
J
S
T
S
.
A
S
P
E
R
SP
A
N
C
H
A
R
T
S
BEAM ABV.AS REQ'D
MASTER BED
M.
B
A
T
H
M. CLOSET
UTILITY
PWD.ENTRYSTOR. 1
ST
O
R
.
2
THREE CAR
GARAGE
PANTRY
OFFICE
BEDROOM 4FOYER
BEDROOM 3
HALL
BATH 2
CLOS.BATH 3
BEDROOM 2
GREAT ROOM
BREAKFAST
KITCHEN
REAR PORCH
FRONT PORCH
LI
N
.
CLOS.
HALL
CLOS.
CO
A
T
CL
O
S
E
T
SCALE:-
1REF-2
MAIN FLOOR STRUCTURAL PLAN
1/4" = 1'-0"
BU
T
L
E
R
'
S
PA
N
T
R
Y
FOR REFERENCE USE ONLY
NOTE:-
THIS SHEET IS FOR REFERENCE ONLY. THE CONTENT ON THIS SHEET WAS CREATED BY
THE ORIGINAL DESIGNER OF THIS PLAN. THIS CONTENT HAS BEEN INCLUDED IN THE DRAWINGS
SET TO CONVEY THE INTENT OF THE ORIGINAL DESIGN. NO CHANGES OR UPDATES HAVE BEEN
MADE TO THE CONTENT ON THIS SHEET, THEREFORE IT MAY NOT CORRESPOND WITH THE OTHER
SHEETS IN THIS DRAWING SET. ReDesign HP DOES NOT ENDORSE AND / OR TAKE RESPONSIBILITY
FOR THE CONTENT ON THIS SHEET. IT IS THE RESPONSIBILITY OF THE BUILDER TO ASSURE THAT
ALL WORK IS IN ACCORDANCE WITH THE LATEST EDITION OF ALL APPLICABLE NATIONAL, STATE,
AND LOCAL BUILDING CODES.
DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
REF-2
AWNING DETAIL
DECO. WD. BRACKET
4 x 10 WD. BM.
2 x VERTICAL SUPPORTANCHORED SECURELY TO WALL
2 x 6 RAFTER
SIDE VIEW
MTL. ROOF
8
12
METAL ROOF
3'-0"
9
0
°
EXPOSED RAFTER TAILS
FRONT VIEW
4"3'-2"4"3'-0"4"3'-2"4"
124
AWNING DETAIL
2'-6"
90 °
4"8'-0"
DECO. WD. BRACKET
4 x 10 WD. BM.
2 x 6 RAFTER
MTL. ROOF
METAL ROOF
EXPOSED RAFTER TAILS
SIDE VIEW FRONT VIEW
4"
FOR REFERENCE USE ONLY
NOTE:-
THIS SHEET IS FOR REFERENCE ONLY. THE CONTENT ON THIS SHEET WAS CREATED BY
THE ORIGINAL DESIGNER OF THIS PLAN. THIS CONTENT HAS BEEN INCLUDED IN THE DRAWINGS
SET TO CONVEY THE INTENT OF THE ORIGINAL DESIGN. NO CHANGES OR UPDATES HAVE BEEN
MADE TO THE CONTENT ON THIS SHEET, THEREFORE IT MAY NOT CORRESPOND WITH THE OTHER
SHEETS IN THIS DRAWING SET. ReDesign HP DOES NOT ENDORSE AND / OR TAKE RESPONSIBILITY
FOR THE CONTENT ON THIS SHEET. IT IS THE RESPONSIBILITY OF THE BUILDER TO ASSURE THAT
ALL WORK IS IN ACCORDANCE WITH THE LATEST EDITION OF ALL APPLICABLE NATIONAL, STATE,
AND LOCAL BUILDING CODES.
TYP. CORNICE DETAIL
1/2" CDX PLYW'D
1"X TRIM BD.
1"x2" TRIM
or 7/16" O.S.B.
2"x SUB-FASCIA
BAFFLES, BETWEEN RAFTER
OVER 30# FELT, OVER
FIBERGLASSASPHALT SHINGLES,
A MAX. OF 12' O.C.24" O.C., BRACE @2"x6" RAFTERS @
INSULATION
2 - 2"x4" TOP PLATE 'S
WALL COVERING
2"x4" STUDS @ 16" O.C.
CEILING JOISTS
INSULATION
GYP. BD.
MOLD
ELEVATIONSSEE
SIDING
VERIFY W/ CODE
VERIFY W/ CODE
VERIFY W/ CODE
STRUCTURAL SHEATHING (RE:NOTE "A")
PROVIDE A MINIMUM OF 7/16" STRUCTURAL WOOD PANEL ATTACHED w/
8d COMMON OR 10d BOX NAILS AT 4" SPACING ON EDGE AND 12" IN FIELD.
PROVIDE HURRICANE
STRAPS ON ALL RAFTERS
AS PER CODE.
NOTE "A":
VENTED HARDIE SOFFIT
1" x FASCIA
NOTE "B": CORNICE DETAIL FOR REFERENCE ONLY. REFER TO BUILDER
SPECS FOR ACTUAL MATERIALS.
OR SIMILAR, REFER TO BUILDER SPECS
INSULATED GARAGE DOOR
BEAM AS REQ'D
GARAGE DOOR TRACK
DOOR STOP WITHFITTED SEAL
RE: FLOOR PLAN
2x4 CASING
CLEARANCE
2"x4" STUDS @ 16" O.C.
RE:FLOOR PLAN FOR SIZE
FOR DOOR HEIGHT
THE INTENT OF THIS DETAIL IS TO SHOW THE MINIMUM REQUIRED DISTANCE FROM
THE TOP OF THE GARAGE DOOR OPENING TO THE CEILING OF THE GARAGE.
GARAGE DOOR DATE :
SCALE : AS NOTED
DRAWN BY : -------------
PROJECT :Landon and Kimberley McBride
SHEET
La
n
d
o
n
a
n
d
K
i
m
b
e
r
l
e
y
M
c
B
r
i
d
e
80
7
Y
o
s
t
S
t
r
e
e
t
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ReDesign HPDesigning for tomorrow
"This plan is a derivative and has been modified by ReDesign HP from the original House Plan Zonestock home plan."
House Plan Zone
LIMITED LICENSE
*You may use these plans for the construction of one and
only one house as depicted by the plans. This license is non-transferable.
*You may change or modify the plans. By changing or modifying the plans, you relieve ReDesign HPand House Plan Zone , of all liability associated with the modified design and plans.
*Building codes are subject to various changes and interpretations. The purchaser is responsible for compliance with all local and national building codes, ordinances, site conditions, subdivision restrictions, and structural design. A licensed engineer should review your plans before you apply for a building permit and before construction begins.
*Final selections of materials are the responsibility of the
homeowner and/or builder, including, but not limited to
proper installation of materials, nailing, gluing, caulking,
insulating, flashing, roofing, weatherproofing and many
other small items and details not necessarily indicated on
the plans, and over which ReDesign HP and House Plan
Zone, has no control or responsibility. ReDesign HP and
House Plan Zone , shall not be held liable for any errors,
omissions, or deficiencies in any form by any party
whatsoever.
*You may loan all or part of the plans to third parties
including contractors and sub-contractors for the sole
purpose of the construction of your house. You agree to
retrieve all loaned copies of the plans after construction is
completed. Mortgage companies and building officials
may retain plans for their records.
House Plan Zone , retains copyright ownership of the original plans and assumes sole copyright ownership of the modified plans. Your payment of a fee for the use of the plans does not transfer any right, title, or interest in the plans.
*Unauthorized use or copying of the plans, or the design they depict infringes upon rights under the copyright act. Copyright infringement carries penalties of up to $100,000 per infringement.
CUSTOM CHANGES
ReDesign HP
COPYRIGHT
These drawings are the exclusive property of House Plan
Zone, Reproduction in whole or in part without the written
permission of House Plan Zone , is in violation and subject
to penalties under the Copyright Laws.
ORIGINAL DESIGN
OCT/01/2019
REF-3