HomeMy WebLinkAboutTRUSS - 19-00671 - 2061 Summerfield Ln - New SFRJob
19-101255T
Truss
A1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:47 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-aMGKYy8DPQEaO_sSikY43ea1Su3zRk9zc_XbtNySqhI
Scale = 1:71.3
T2 T2
B1
W1
W2
W3
W4
W2
W3
W4T1 T1
B1B2B2
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3ST2
ST1
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3 ST2
ST1
A B
C
D
E
F
G
H I
L K JBEBFBGBH
5x6
5x6
5x8
2x4
5x8
3x4
5x8
4x5
5x8
3x4
5x8
5x6
10-0-0
10-0-0
20-0-0
10-0-0
30-0-0
10-0-0
40-0-0
10-0-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
10
-
9
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [C:0-4-0,0-3-0], [G:0-4-0,0-3-0], [H:0-1-11,Edge], [J:0-2-0,0-2-0], [J:0-4-0,0-3-0], [K:0-4-0,0-3-4], [L:0-4-0,0-3-4], [L:0-1-8,0-0-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.65
0.68
0.67
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.13
(loc)
K-L
J-K
H
K
l/defl
>999
>847
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 303 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-7-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-3-4 oc bracing.
WEBS 1 Row at midpt F-K, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2043/0-3-8 (min. 0-2-3), H=2051/0-5-8 (min. 0-2-3)
Max Horz B=-224(LC 8)
Max UpliftB=-351(LC 10), H=-355(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3705/1073, C-D=-3297/1008, D-E=-2302/802, E-F=-2302/802, F-G=-3276/1002,
G-H=-3675/1063
BOT CHORD B-L=-833/3194, L-BE=-572/2584, BE-BF=-572/2584, K-BF=-572/2584, K-BG=-570/2575,
BG-BH=-570/2575, J-BH=-570/2575, H-J=-821/3158
WEBS E-K=-486/1426, F-K=-927/401, F-J=-124/593, G-J=-488/275, D-K=-937/404, D-L=-131/612,
C-L=-508/284
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=40ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=351,
H=355.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-101255T
Truss
A2
Truss Type
Common
Qty
24
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:50 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-_xyTA_A5hLc9FRb1Nt6ngHCXh65ge4uPIymFUiySqhF
Scale = 1:67.1
T2 T2
B1
W1 W2
W3
W4
W2
W3
W4T1 T1
B1B2B2AB
C
D
E
F
G
H I
L K JMNOP
5x6
5x6
5x8 5x8
3x4
5x8
5x8
3x4
5x8
5x6
10-0-0
10-0-0
20-0-0
10-0-0
30-0-0
10-0-0
40-0-0
10-0-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
10
-
9
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [C:0-4-0,0-3-0], [G:0-4-0,0-3-0], [H:0-1-11,Edge], [J:0-4-0,0-3-4], [K:0-4-0,0-3-4], [L:0-4-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.65
0.68
0.67
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.13
(loc)
K-L
J-K
H
K
l/defl
>999
>847
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 188 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-7-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-3-4 oc bracing.
WEBS 1 Row at midpt F-K, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2043/0-3-8 (min. 0-2-3), H=2051/0-5-8 (min. 0-2-3)
Max Horz B=194(LC 9)
Max UpliftB=-351(LC 10), H=-355(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-3705/1073, C-D=-3297/1008, D-E=-2302/802, E-F=-2302/802, F-G=-3276/1002,
G-H=-3675/1063
BOT CHORD B-L=-833/3194, L-M=-572/2584, M-N=-572/2584, K-N=-572/2584, K-O=-570/2575,
O-P=-570/2575, J-P=-570/2575, H-J=-821/3158
WEBS E-K=-486/1426, F-K=-927/401, F-J=-124/580, G-J=-488/275, D-K=-937/404, D-L=-131/599,
C-L=-508/284
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=351,
H=355.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-101255T
Truss
A3
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:52 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-wJ3DbgCMDyssUlkPUI8FmiHurvoC609imFFMYbySqhD
Scale = 1:70.1
T2 T2
B1
W1
W2
W3
W4 W5
W2W3
W4W5
ST8
ST9
ST6
ST7
ST4
ST5
ST3ST2
ST1
ST8
ST9
ST6
ST7
ST4
ST5
ST3
T1 T1
B1B2AB
C
D
E
F
G
H I
O N L K JAPAQARMAS
5x8
5x6
5x8
3x6
5x8 4x8
3x4
5x6
3x6
3x6
Special
Special Special
6-8-0
6-8-0
13-1-4
6-5-4
13-4-0
0-2-12
18-6-0
5-2-0
20-0-0
1-6-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
20-0-0
6-8-0
26-8-0
6-8-0
33-4-0
6-8-0
40-0-0
6-8-0
41-0-0
1-0-0
0-
4
-
3
10
-
4
-
3
10
-
9
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [C:0-4-0,0-3-4], [G:0-4-0,0-3-0], [H:0-2-12,0-1-8], [K:0-3-0,0-3-0], [N:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.61
0.55
0.56
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.10
-0.16
0.03
0.05
(loc)
K-L
K-L
H
M-N
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 283 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W3,W5: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-4-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt E-L, F-L, D-N
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 0-5-8 except (jt=length) H=0-3-8, M=0-3-8.
(lb) - Max Horz B=-194(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) except B=-108(LC 8), N=-411(LC 8), H=-208(LC 8), M=-227(LC 8)
Max Grav All reactions 250 lb or less at joint(s) except B=580(LC 17), N=2373(LC 1), H=1161(LC 1), M=695(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-546/306, C-D=-31/750, D-E=-422/153, E-F=-401/153, F-G=-1106/213, G-H=-1827/266
BOT CHORD B-O=-248/381, N-O=-250/378, N-AP=-568/202, AP-AQ=-568/202, AQ-AR=-568/202,
M-AR=-568/202, L-M=-568/202, L-AS=0/874, K-AS=0/874, J-K=-149/1516, H-J=-148/1519
WEBS E-L=-332/51, F-L=-988/234, F-K=-26/480, G-K=-733/175, D-L=-44/1105, D-N=-1693/268,
C-N=-747/167
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint B, 411 lb uplift at joint N,
208 lb uplift at joint H and 227 lb uplift at joint M.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 190 lb down and 88 lb up at
13-11-4, and 190 lb down and 88 lb up at 15-11-4, and 190 lb down and 88 lb up at 17-11-4 on bottom chord. The design/selection of
such connection device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Continued on page 2
Job
19-101255T
Truss
A3
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:53 2019 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-PWdcp0C__G_j6vJc2?fUIvq3bJ8RrTPr?v_v41ySqhC
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-E=-84, E-I=-84, B-H=-14
Concentrated Loads (lb)
Vert: AP=-190(B) AQ=-190(B) AR=-190(B)
Job
19-101255T
Truss
B1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:54 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-tiB_0LDclZ6ak3uocjAjr7MHBjWFawh?DZkTdTySqhB
Scale = 1:39.0
T1 T2
B1
W1
W2 W3W2W3
ST4ST2
ST3ST1
ST4 ST2
ST3 ST1
B1A
B
C
D
E
F
I H GXYZAAABACADAE AF AG
5x6
3x6 3x6 5x8
3x4 3x4
Special Special Special Special
Special
Special Special Special Special Special
4-9-0
4-9-0
10-9-0
6-0-0
16-9-0
6-0-0
21-6-0
4-9-0
-1-0-0
1-0-0
4-9-0
4-9-0
10-9-0
6-0-0
16-9-0
6-0-0
21-6-0
4-9-0
0-
4
-
3
5-
8
-
1
1
6-
2
-
7
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [H:0-4-0,0-3-0], [L:0-1-12,0-0-12], [U:0-1-12,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.42
0.38
0.56
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.10
-0.14
0.05
0.05
(loc)
H-I
H-I
F
H-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 113 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-4-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)F=1143/0-3-8 (min. 0-1-8), B=1244/0-3-8 (min. 0-1-8)
Max Horz B=108(LC 7)
Max UpliftF=-249(LC 8), B=-296(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2110/456, C-D=-1419/343, D-E=-1420/343, E-F=-2130/467
BOT CHORD B-X=-361/1804, X-Y=-361/1804, I-Y=-361/1804, I-Z=-361/1804, Z-AA=-361/1804,
AA-AB=-361/1804, H-AB=-361/1804, H-AC=-374/1825, AC-AD=-374/1825, AD-AE=-374/1825,
G-AE=-374/1825, G-AF=-374/1825, AF-AG=-374/1825, F-AG=-374/1825
WEBS D-H=-163/686, E-H=-748/221, C-H=-725/208
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 249 lb uplift at joint F and 296 lb uplift at joint
B.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 21 lb down and 18 lb up at 2-0-12,
21 lb down and 18 lb up at 4-0-12, 21 lb down and 18 lb up at 6-0-12, 21 lb down and 18 lb up at 8-0-12, 21 lb down and 18 lb up at
10-0-12, 21 lb down and 18 lb up at 12-0-12, 21 lb down and 18 lb up at 14-0-12, 21 lb down and 18 lb up at 16-0-12, and 21 lb down
and 18 lb up at 18-0-12, and 21 lb down and 18 lb up at 20-0-12 on bottom chord. The design/selection of such connection device(s)
is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Continued on page 2
Job
19-101255T
Truss
B1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:54 2019 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-tiB_0LDclZ6ak3uocjAjr7MHBjWFawh?DZkTdTySqhB
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-F=-84, B-F=-14
Concentrated Loads (lb)
Vert: X=-21(F) Y=-21(F) Z=-21(F) AA=-21(F) AB=-21(F) AC=-21(F) AD=-21(F) AE=-21(F) AF=-21(F) AG=-21(F)
Job
19-101255T
Truss
B2
Truss Type
Common
Qty
1
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:55 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-LulMDhEEWtERLDT_AQhyNKvTA7t?JSc8SDT09wySqhA
Scale = 1:36.2
T1 T2
B1
W1
W2
W1
W2
B2A
B
C
D
E
F
H G
4x5
3x6 3x6 5x6
1.5x4
3x4
1.5x4
7-2-0
7-2-0
14-4-0
7-2-0
21-6-0
7-2-0
-1-0-0
1-0-0
5-4-8
5-4-8
10-9-0
5-4-8
16-1-8
5-4-8
21-6-0
5-4-8
0-
4
-
3
5-
8
-
1
1
6-
2
-
7
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [G:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.34
0.35
0.26
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.13
0.04
0.04
(loc)
F-G
F-G
F
F-G
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 89 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-7-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)F=1036/0-3-8 (min. 0-1-8), B=1144/0-3-8 (min. 0-1-8)
Max Horz B=108(LC 9)
Max UpliftF=-160(LC 10), B=-212(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-1853/533, C-D=-1595/521, D-E=-1606/531, E-F=-1865/544
BOT CHORD B-H=-406/1566, G-H=-182/1028, F-G=-419/1580
WEBS D-G=-175/579, E-G=-446/244, D-H=-159/563, C-H=-438/237
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 160 lb uplift at joint F and 212 lb uplift at joint
B.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-101255T
Truss
C1
Truss Type
Common
Qty
1
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:57 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-HHt6eNFU2UU9bWdNHrkQTl_t_wdanPORvXy7DoySqh8
Scale = 1:24.8
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
A
B
C
D
E
F
G
H
I
N M L K J
4x5
3x4 3x4
13-4-0
13-4-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
14-4-0
1-0-0
0-
4
-
3
3-
8
-
3
4-
1
-
1
5
0-
4
-
3
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.02
0.05
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
I
I
H
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 55 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-4-0.
(lb) - Max Horz B=-71(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) B, H, M, N, K, J
Max Grav All reactions 250 lb or less at joint(s) B, H, L, M, N, K, J
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-101255T
Truss
C2
Truss Type
Common
Qty
3
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:58 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-lTRUsjG7poc0CgCZrYFf?zXxRKt_Wrha8BigmFySqh7
Scale = 1:23.3
T1
T2
B1
W1
A
B
C
D
E
5x6
3x6 3x6 1.5x4
6-8-0
6-8-0
13-4-0
6-8-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
0-
4
-
3
3-
8
-
3
4-
1
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-2-9,0-1-8], [D:0-2-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.53
0.40
0.11
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.12
0.01
0.04
(loc)
D-E
D-E
D
D-E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 44 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-8-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)D=625/0-5-8 (min. 0-1-8), B=745/0-5-8 (min. 0-1-8)
Max Horz B=70(LC 9)
Max UpliftD=-95(LC 10), B=-153(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-906/271, C-D=-903/269
BOT CHORD B-E=-143/690, D-E=-143/690
WEBS C-E=0/261
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=153.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-101255T
Truss
J1
Truss Type
Jack-Open
Qty
3
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:53:59 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-Df_t33Hla6ktqqnmPGmuYA49EkHDFJhkNrREIhySqh6
Scale = 1:17.3
T1
B1
W1
A
B
C
D
1.5x4
2x4 1.5x4
5-0-0
5-0-0
-1-0-0
1-0-0
5-0-0
5-0-0
0-
4
-
3
2-
1
0
-
3
3-
3
-
1
5
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.34
0.14
0.06
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.03
-0.04
0.00
0.00
(loc)
B-D
B-D
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 19 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=346/0-3-8 (min. 0-1-8), D=218/Mechanical
Max Horz B=103(LC 10)
Max UpliftB=-71(LC 10), D=-49(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-101255T
Truss
J2
Truss Type
Jack-Open
Qty
10
Ply
1
KARTCHNER HOMES SF4BB10 ATHENS B
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Wed Oct 16 11:54:00 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:T0JV11M2SeCbfihfSNRYxZz1Lh4-hsYFHPINLPskS_MyyzH74OcOK8fp_mrtcVBnq7ySqh5
Scale = 1:8.2
T1
B1
A
B
C
D
3x4
1-6-0
1-6-0
-1-0-0
1-0-0
1-6-0
1-6-0
0-
4
-
3
1-
1
-
3
1-
6
-
1
5
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.13
0.05
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
B
B-D
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 6 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 1-6-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=198/0-3-8 (min. 0-1-8), D=38/Mechanical
Max Horz B=91(LC 10)
Max UpliftB=-124(LC 10), D=-24(LC 10)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=124.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard