HomeMy WebLinkAboutPLANS REDLINED REVISIONS - 19-00590 - Fullmer - Medical Office BuildingReview Report Current Building Review Status: REVISIONS Application Number: 19-00590Permit Details Application Received Date: 09/27/2019 New Commercial Building Application Approved Date: Application Approved Status: ACCEPTED 09/27/2019 RPR6N39E246501 Fullmer - RPR6N39E246501 - Medical Office Building Status of Plan Reviews Completed 10/01/2019Electrical Review COMPLETED 10/02/2019Fire Department Review - Site Plan COMPLETED 10/09/2019Public Works Review - Site Plan COMPLETED 10/11/2019HVAC Review COMPLETED 10/11/2019Plumbing Review COMPLETED 10/11/2019Planning and Zoning Review - Site Plan REVISIONS 10/15/2019Building Review REVISIONS Permit Review Status Plan Reviews Still in Progress Fire Alarm Review Fire Sprinkler Review Planning and Zoning Review - Site Plan DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Incidental use meets the requirements of Table 509 REVISIONSAmbulatory care facilities require 1 hour separation for the following incidental uses: * Laboratories not classified as group H (N/A - no labs included in this building) * Waste and linen rooms with containers having an aggregate volume of 10 cubic feet or greater. * Storage rooms greater than 100 sf. *Revisions Response : Fire resistance rating of building elements meet Sect. 704 & Table 601 REVISIONSAs per V-A construction, structural elements are to have fire rated protection per Table 601. * Fire rated protection is not identified on plans details. *Revisions Response : Handrails and Guards meet the requirements of IBC Sections 1014 and 1015 REVISIONSNo drawings or details included for handrails. *Revisions Response : Reviewed By: Quinton Owens Review Date: 10/15/2019 Plan Review Details quinton.owens@rexburg.org Building Review Status: REVISIONS Page 1 of 2 Approval of plans does not constitute approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Building complies with IECC (IBC 1301)REVISIONS* Plans do not show all R-values for thermal barrier compliance. * Is basement and/or crawl space conditioned? Building section shows floor insulation with no foundation insulation and no ventilation vents in foundation, and all ducts in crawl space are required to be insulated if the space is unconditioned. *Revisions Response : Glass and Glazing meets the requirements of IBC Chapter 24 REVISIONSWindow type A is not identified as tempered per 2406.4.3. Is there an exception for these windows or was it just overlooked? *Revisions Response : Stairways meet the requirements of IBC Section 1011 & 1019 REVISIONSNo drawings or details included for interior stairs. *Revisions Response : Type of construction is identified.Type VA construction is identified on plans.COMPLETED Penetrations comply with IBC Section 714 for rated assemblies Maintain fire rated protection at all penetrations in protected assemblies. COMPLETED Automatic sprinklers are provided or exempted as per IBC Section 903.2 Sprinkler system not required, but a fire alarm system is required per 907.2.2 (see IBC 422.5) COMPLETED Occupant load is identified on plans as per IBC Section 1004 Occupant loads are not identified on plans as required. * Default occupant load for entire building will be 97 based on B occupancy COMPLETED Toilets, Bathing Fac., Sinks, Kit. and Drink. Fount. meet IBC Sec. 1109 Toilet rooms accessed only through a private office do not require grab bars, but shall have backing installed for potential installation of grab bars (A117.1, 604.5) COMPLETED Page 2 of 2 Approval of plans does not constitute approval of variance from code