HomeMy WebLinkAboutFIRE ALARM REPORT - 19-00602 - Madison Middle School - Fire Alarm PanelForm Completion Date: 10-15-19 Supplemental Pages Attached: 1. PROPERTY INFORMATION Name of property: Madison Middle School 2. 3 9 Address: 575 W 7th S, Rexburg ID 83440 Description of property: Middle School Name of property representative: Madison School District (Reed Ellis) Address: 60 W Main St, Rexburg ID 83440 Phone: 208-359-3300 Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Fire Services of Idaho Address: 610 Mallard St Chubbuck Id, 83202 Phone: 208-232-3640 Fax: Service organization: Fire Services of Idaho Address: 610 Mallard St Chubbuck Id, 83202 Phone: 208-232-3640 Fax: Testing organization: Fire Services of Idaho Address: 610 Mallard St Chubbuck Id, 83202 Phone: 208-232-3640 Fax: Effective date for test and inspection contract: Monitoring organization: Avantguard Address: Phone: 877-206-9141 Fax: Account number: AE01-0257 Phone line 1: Means of transmission: Alarm Contacts Entity to which alarms are retransmitted: Avantguard DOCUMENTATION On-site location of the required record documents and site-specific FACP software: DESCRIPTION OF SYSTEM OR SERVICE This is a: New System Modification to existing system X Permit number: NFPA 72 edition: 2016 4.1 Control Unit Manufacturer: Silent Knight 4.2 Software and Firmware Firmware revision number: 6.0.20 1 208-232-0449 E-mail: 208-232-0449 E-mail: 208-232-0449 E-mail: Model number: 6820 E-mail: P] P] 4.3 Alarm Verification Number of devices subject to alarm verification: 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: Overcurrent protection: Type: Branch circuit disconnecting means location: This system does not incorporate alarm verification. Alarm verification set for sec 24 Control panel amps: Amps: Number: 5.1.2 Secondary Power Type of secondary power: Batteries Location, if remote from the plant: in FACP Calculated capacity of secondary power to drive the system:24V In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit This system does not have power extender panels X Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line 21 Addressable B Device Power 61 Addressable alarm photoelectric Initiating Device B Notification Appliance Other (specify): 7. REMOTE ANNUNCIATORS Type Location None 8. INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 21 Addressable alarm Smoke Detectors 61 Addressable alarm photoelectric 2 Duct Smoke Detectors 0 Description Audible Hold -Open Door Releasing Devices Heat Detectors 3 0 Fire/Smoke Dampers RO R Gas Detectors 0 Elevator Recall 0 Elevator Shunt Trip Waterflow Switches 3 Addressable alarm paddle Tamper Switches 3 Addressable Supervisory 9. NOTIFICATION APPLIANCES Type Quantity Description Audible Hold -Open Door Releasing Devices 0 Visible 0 Fire/Smoke Dampers Combination Audible and Visible 49 0 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold -Open Door Releasing Devices 0 HVAC Shutdown 0 Fire/Smoke Dampers 0 Door Unlocking 0 Elevator Recall 0 Elevator Shunt Trip 0 11. INTERCONNECTED SYSTEMS This system does not have interconnected systems. X Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: Dan Sneigoski Organization: FSI Title: Alarm Technician Date: Phone: 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Printed name: Dan Sneigoski Date: Organization: FSI Title: Alarm Tech Phone: 12.3 Acceptance Test 3 Date and time of acceptance test: 10-15-19 Installing contractor representative: Dan Sneigoski Testing contractor representative: Dan Sneigoski Property representative: AHJ representative: Reed Ellis