Loading...
HomeMy WebLinkAboutPLANS ELECTRICAL - 19-00649 - Mountain View Clinic - RemodelMO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E0 . 1 CD RB EL E C T R I C A L CO V E R S H E E T DESIGN CONTACTS ’ COMMISSIONING NOTES: ELECTRICAL GENERAL NOTES: (S) ABBREVIATIONS INDEX ELECTRICAL SYMBOLS SHEET INDEX MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E1 . 1 CD RB PO W E R P L A N N POWER PLAN ELECTRICAL KEYED NOTES: MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E1 . 2 CD RB LI G H T I N G P L A N ELECTRICAL KEYED NOTES: N LIGHTING PLAN MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E5 . 1 CD RB EL E C T R I C A L DE T A I L S COPPER FEEDER SCHEDULE EQUIPMENT GROUNDING CONDUCTORS SCHEDULE FIRE ALARM RISER DIAGRAM FACP RFAA NOTES: KEYED NOTES: DATA/VOICE JACK INSTALLATION DETAIL ELECTRICAL GENERAL NOTES: COMMUNICATIONS RISER DIAGRAM PARTIAL POWER ONE-LINE DIAGRAM KEYED NOTES: ------ --- --- MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E5 . 2 CD RB EL E C T R I C A L DE T A I L S DEVICE MOUNTING HEIGHTS INSTALLATION DETAIL--- MOTION SENSOR WITH LV SWITCH--- LIGHTING CONTROL PANEL WIRING DIAGRAM KEYED NOTE: --- "LCP" TYPICAL RECESSED FIXTURE MOUNTING DETAIL--- KEYED NOTES: ELECTRICAL EQUIPMENT WORK SPACE CLEARANCES GENERAL NOTE: --- ROUGH-IN DETAIL FOR MEDICAL GRADE MC CABLE KEYED NOTES: GENERAL NOTES: --- MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E5 . 3 CD RB EL E C T R I C A L DE T A I L S CONDENSING UNIT CONDUIT INSTALLATION DETAIL--- WALL PENETRATION FLOOR PENETRATION FIRE RATED PENETRATION DETAIL--- LIGHT/FAN INTERPOSING RELAY WIRING DIAGRAM--- WEATHERPROOF RECEPTACLE INSTALLATION DETAIL--- ELECTRIC WATER COOLER INSTALLATION DETAIL REGULAR ACCESSIBLE --- LOW-VOLTAGE TRANSFORMERS A.GENERAL 1.REFERENCE STANDARDS a.10 CFR 431, SUBPART K - ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT - DISTRIBUTION TRANSFORMERS; CURRENT EDITION. b.IEEE C57.94 - RECOMMENDED PRACTICE FOR INSTALLATION, APPLICATION, OPERATION, AND MAINTENANCE OF DRY-TYPE GENERAL PURPOSE DISTRIBUTION AND POWER TRANSFORMERS; INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS; 1982 (R2006). c.IEEE C57.96 - GUIDE FOR LOADING DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS; INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS; 1999 (R2004). d.NECA 1 - STANDARD FOR GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION; NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION; 2010. e.NECA 409 - STANDARD FOR INSTALLING AND MAINTAINING DRY-TYPE TRANSFORMERS; NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION; 2009. f.NEMA ST 20 - DRY-TYPE TRANSFORMERS FOR GENERAL APPLICATIONS; NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION; 2014. g.NEMA 250 - ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM); NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION; 2014 h.NFPA 70 - NATIONAL ELECTRICAL CODE; NATIONAL FIRE PROTECTION ASSOCIATION; MOST RECENT EDITION ADOPTED BY AUTHORITY HAVING JURISDICTION, INCLUDING ALL APPLICABLE AMENDMENTS AND SUPPLEMENTS. i.UL 506 - STANDARD FOR SPECIALTY TRANSFORMERS; CURRENT EDITION, INCLUDING ALL REVISIONS. j.UL 1561 - STANDARD FOR DRY-TYPE GENERAL PURPOSE AND POWER TRANSFORMERS; CURRENT EDITION, INCLUDING ALL REVISIONS. B.PRODUCTS 1.TRANSFORMERS - GENERAL REQUIREMENTS a.DESCRIPTION: FACTORY-ASSEMBLED, DRY TYPE TRANSFORMERS FOR 60 HZ OPERATION DESIGNED AND MANUFACTURED IN ACCORDANCE WITH NEMA ST 20 AND LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE INTENDED. b.UNLESS NOTED OTHERWISE, TRANSFORMER RATINGS INDICATED ARE FOR CONTINUOUS LOADING ACCORDING TO IEEE C57.96 UNDER THE FOLLOWING SERVICE CONDITIONS: 1)ALTITUDE: LESS THAN 3,300 FEET (1,000 M). 2)AMBIENT TEMPERATURE: a)GREATER THAN 10 KVA: NOT EXCEEDING 104 DEGREES F (40 DEGREES C). b)LESS THAN 10 KVA: NOT EXCEEDING 77 DEGREES F (25 DEGREES C). c.CORE: HIGH GRADE, NON-AGING SILICON STEEL WITH HIGH MAGNETIC PERMEABILITY AND LOW HYSTERESIS AND EDDY CURRENT LOSSES. KEEP MAGNETIC FLUX DENSITIES SUBSTANTIALLY BELOW SATURATION POINT, EVEN AT 10 PERCENT PRIMARY OVERVOLTAGE. TIGHTLY CLAMP CORE LAMINATIONS TO PREVENT PLATE MOVEMENT AND MAINTAIN CONSISTENT PRESSURE THROUGHOUT CORE LENGTH. d.IMPREGNATE CORE AND COIL ASSEMBLY WITH NON-HYDROSCOPIC THERMO-SETTING VARNISH TO EFFECTIVELY SEAL OUT MOISTURE AND OTHER CONTAMINANTS. e.BASIC IMPULSE LEVEL: 10 KV. f.GROUND CORE AND COIL ASSEMBLY TO ENCLOSURE BY MEANS OF A VISIBLE FLEXIBLE COPPER GROUNDING STRAP. g.ISOLATE CORE AND COIL FROM ENCLOSURE USING VIBRATION-ABSORBING MOUNTS. h.NAMEPLATE: INCLUDE TRANSFORMER CONNECTION DATA, RATINGS, WIRING DIAGRAMS, AND OVERLOAD CAPACITY BASED ON RATED WINDING TEMPERATURE RISE. 2.GENERAL PURPOSE TRANSFORMERS a.DESCRIPTION: SELF-COOLED, TWO WINDING TRANSFORMERS LISTED AND LABELED AS COMPLYING WITH UL 506 OR UL 1561; RATINGS AS INDICATED ON THE DRAWINGS. b.INSULATION SYSTEM AND ALLOWABLE AVERAGE WINDING TEMPERATURE RISE: 1)LESS THAN 15 KVA: CLASS 180 DEGREES C INSULATION SYSTEM WITH 115 DEGREES C AVERAGE WINDING TEMPERATURE RISE. 2)15 KVA AND LARGER: CLASS 220 DEGREES C INSULATION SYSTEM WITH 150 DEGREES C AVERAGE WINDING TEMPERATURE RISE. c.COIL CONDUCTORS: CONTINUOUS ALUMINUM WINDINGS WITH TERMINATIONS BRAZED OR WELDED. d.WINDING TAPS: 1)LESS THAN 3 KVA: NONE. 2)3 KVA THROUGH 15 KVA: TWO 5 PERCENT FULL CAPACITY PRIMARY TAPS BELOW RATED VOLTAGE. 3)15 KVA THROUGH 300 KVA: TWO 2.5 PERCENT FULL CAPACITY PRIMARY TAPS ABOVE AND FOUR 2.5 PERCENT FULL CAPACITY PRIMARY TAPS BELOW RATED VOLTAGE. 4)500 KVA AND LARGER: TWO 2.5 PERCENT FULL CAPACITY PRIMARY TAPS ABOVE AND TWO 2.5 PERCENT FULL CAPACITY PRIMARY TAPS BELOW RATED VOLTAGE. e.ENERGY EFFICIENCY: COMPLY WITH 10 CFR 431, SUBPART K. f.SOUND LEVELS: STANDARD SOUND LEVELS COMPLYING WITH NEMA ST 20. g.MOUNTING PROVISIONS: 1)LESS THAN 15 KVA: SUITABLE FOR WALL MOUNTING. 2)15 KVA THROUGH 75 KVA: SUITABLE FOR WALL, FLOOR, OR TRAPEZE MOUNTING. 3)LARGER THAN 75 KVA: SUITABLE FOR FLOOR MOUNTING. h.TRANSFORMER ENCLOSURE: COMPLY WITH NEMA ST 20. 1)ENVIRONMENT TYPE PER NEMA 250: UNLESS OTHERWISE INDICATED, AS SPECIFIED FOR THE FOLLOWING INSTALLATION LOCATIONS: 2)CONSTRUCTION: STEEL. a)LESS THAN 15 KVA: TOTALLY ENCLOSED, NON-VENTILATED. b)15 KVA AND LARGER: VENTILATED. 3)FINISH: MANUFACTURER'S STANDARD GREY, SUITABLE FOR OUTDOOR INSTALLATIONS. 4)PROVIDE LIFTING EYES OR BRACKETS. i.ACCESSORIES: 1)MOUNTING BRACKETS: PROVIDE MANUFACTURER'S STANDARD BRACKETS. 2)WEATHERSHIELD KITS: PROVIDE FOR VENTILATED TRANSFORMERS INSTALLED OUTDOORS TO PROVIDE A LISTED NEMA 250, TYPE 3R ASSEMBLY. 3)LUG KITS: SIZED AS REQUIRED FOR TERMINATION OF CONDUCTORS AS INDICATED ON THE DRAWINGS. C.EXECUTION 1.INSTALLATION a.PERFORM WORK IN A NEAT AND WORKMANLIKE MANNER IN ACCORDANCE WITH NECA 1. b.INSTALL TRANSFORMERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. c.INSTALL TRANSFORMERS IN ACCORDANCE WITH NECA 409 AND IEEE C57.94. d.USE FLEXIBLE CONDUIT, UNDER THE PROVISIONS OF THE CONDUIT SECTION OF THIS SPECIFICATION, 2 FEET (600 MM) MINIMUM LENGTH, FOR CONNECTIONS TO TRANSFORMER CASE. MAKE CONDUIT CONNECTIONS TO SIDE PANEL OF ENCLOSURE. e.ARRANGE EQUIPMENT TO PROVIDE MINIMUM CLEARANCES AS SPECIFIED ON TRANSFORMER NAMEPLATE AND IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NFPA 70. f.MOUNT WALL-MOUNTED TRANSFORMERS USING INTEGRAL FLANGES OR ACCESSORY BRACKETS FURNISHED BY THE MANUFACTURER. g.MOUNT FLOOR-MOUNTED TRANSFORMERS ON PROPERLY SIZED 3 INCH (80 MM) HIGH CONCRETE PAD CONSTRUCTED IN ACCORDANCE WITH MANUFACTURER SPECIFICATION. h.MOUNT FLOOR-MOUNTED, TRAPEZE-MOUNTED, WALL-MOUNTED, AND CEILING-MOUNTED TRANSFORMERS USING VIBRATION ISOLATORS SUITABLE FOR ISOLATING THE TRANSFORMER NOISE FROM THE BUILDING STRUCTURE. i.MOUNT TRAPEZE-MOUNTED TRANSFORMERS AS INDICATED. j.PROVIDE SEISMIC RESTRAINTS. k.PROVIDE GROUNDING AND BONDING IN ACCORDANCE WITH THE GROUNDING SECTION OF THIS SPECIFICATION. l.REMOVE SHIPPING BRACES AND ADJUST BOLTS THAT ATTACH THE CORE AND COIL MOUNTING BRACKET TO THE ENCLOSURE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS IN ORDER TO REDUCE AUDIBLE NOISE TRANSMISSION. m.WHERE NOT FACTORY-INSTALLED, INSTALL LUGS SIZED AS REQUIRED FOR TERMINATION OF CONDUCTORS AS SHOWN ON THE DRAWINGS. n.WHERE FURNISHED AS A SEPARATE ACCESSORY, INSTALL TRANSFORMER WEATHERSHIELD PER MANUFACTURER'S INSTRUCTIONS. 2.ADJUSTING a.MEASURE PRIMARY AND SECONDARY VOLTAGES AND MAKE APPROPRIATE TAP ADJUSTMENTS. b.ADJUST TIGHTNESS OF MECHANICAL AND ELECTRICAL CONNECTIONS TO MANUFACTURER'S RECOMMENDED TORQUE SETTINGS. 3.CLEANING a.CLEAN DIRT AND DEBRIS FROM TRANSFORMER COMPONENTS ACCORDING TO MANUFACTURER'S INSTRUCTIONS. b.REPAIR SCRATCHED OR MARRED EXTERIOR SURFACES TO MATCH ORIGINAL FACTORY FINISH. MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E6 . 1 CD RB EL E C T R I C A L SC H E D U L E S PANEL SCHEDULE "H1A" VOLTAGE:480 Y/ 277 VOLTS BUS RATING (AMPS):400 REMARKS: MOUNTING:FLUSH PHASE:3 MAIN LUGS ONLY ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 20 1 -HALLWAY LIGHTING ¾"#12 #12 1.25 2,627 4,993 2,366 1.25 #12 #12 ¾"E SIDE & RECEPTION LIGHTING -1 20 2 3 20 1 -W SIDE AND CENTER LIGHTING ¾"#12 #12 1.25 2,604 5,190 2,586 1.25 #12 #12 ¾"SPACE B RECPT LIGHTS -1 20 4 5 20 1 -PT GYM (LCP-2 THRU 5)¾"#12 #12 1.25 3,850 5,748 1,898 1.25 #12 #12 ¾"SPACE C LIGHTS -1 20 6 7 20 3 -RTU-4a ¾"#12 #12 1.00 4,157 8,702 4,545 1.00 #10 #10 ¾"RTU-5e -3 30 8 9 -----#12 -1.00 4,157 8,702 4,545 1.00 -#10 -----10 11 -----#12 -1.00 4,157 8,702 4,545 1.00 -#10 -----12 13 30 3 -RTU-5c ¾"#10 #10 1.00 4,545 9,090 4,545 1.00 #10 #10 ¾"RTU-5d -3 30 14 15 -----#10 -1.00 4,545 9,090 4,545 1.00 -#10 -----16 17 -----#10 -1.00 4,545 9,090 4,545 1.00 -#10 -----18 19 30 3 -RTU-5b ¾"#10 #10 1.00 4,545 9,090 4,545 1.00 #10 #10 ¾"RTU-5a -3 30 20 21 -----#10 -1.00 4,545 9,090 4,545 1.00 -#10 -----22 23 -----#10 -1.00 4,545 9,090 4,545 1.00 -#10 -----24 25 100 3 -X-RAY 1¼"#3 #8 1.00 22,160 22,160 1.00 SPACE -26 27 -----#3 -1.00 22,160 22,160 1.00 SPACE -28 29 -----#3 -1.00 22,160 22,160 1.00 SPACE -30 300A SUB-FEED CIRCUIT BREAKER TRANSFORMER A1 SEE ONE-LINE 1.00 53,145 53,145 --DIAGRAM FOR 1.00 44,090 44,090 -REQUIREMENTS 1.00 55,039 55,039 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.107,179 98,321 109,829 315,329 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 379 CONNECTED LOAD (A) ELECTRICAL CODE.1,248 1,298 1,437 3,983 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 108,427 99,619 111,266 319,312 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 391 359 401 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"401 MAXIMUM LOAD (A) 4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL 34%31%35%PHASE BALANCE EFFICIENCY CERTIFICATES PER IECC R401.3 5.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. PANEL SCHEDULE "L1A" VOLTAGE:208 Y/ 120 VOLTS BUS RATING (AMPS):600 REMARKS: MOUNTING:FLUSH PHASE:3 MAIN CIRCUIT BREAKER:600 ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 20 1 -MAIN BUILDING TERM BOARD ¾"#12 #12 1.00 720 1,440 720 1.00 #12 #12 ¾"LIGHTING CONTROL PANEL -1 20 2 3 20 1 RED FACP ¾"#12 #12 1.00 720 2,720 2,000 1.00 #10 #10 ¾"IT SERVER RCPT -1 30 4 5 30 1 -IT SERVER RCPT ¾"#10 #10 1.00 2,000 4,000 2,000 1.00 #10 #10 ¾"IT SERVER RCPT -1 30 6 7 20 1 -CONFERENCE RCPT ¾"#12 #12 1.00 1,080 2,340 1,260 1.00 #12 #12 ¾"RR/HALL RCPT -1 20 8 9 20 1 -DISPOSAL ¾"#12 #12 0.50 820 1,820 1,000 1.00 #12 #12 ¾"BREAK MICROWAVE -1 20 10 11 20 1 -BREAK COUNTER RCPT ¾"#12 #12 0.50 360 1,360 1,000 0.50 #12 #12 ¾"BREAK MICROWAVE -1 20 12 13 20 1 -BREAK FRIDGE RCPT ¾"#12 #12 0.50 1,200 1,920 720 0.50 #12 #12 ¾"OFFICE/EXAM RCPT -1 20 14 15 20 1 -EXAM RCPT ¾"#12 #12 0.50 720 1,800 1,080 0.50 #12 #12 ¾"BREAK ROOM RCPT -1 20 16 17 20 1 -EXAM RCPT ¾"#12 #12 0.50 720 1,440 720 0.50 #12 #12 ¾"NURSES STATION RCPT -1 20 18 19 20 1 -NURSES STATION RCPT ¾"#12 #12 0.50 1,080 1,440 360 0.50 #12 #12 ¾"SLEEP RCPT -1 20 20 21 20 1 -SLEEP TEC/EXAM RCPT ¾"#12 #12 0.50 540 1,080 540 0.50 #12 #12 ¾"EXAM RCPT -1 20 22 23 20 1 -PROCEDURE RCPT ¾"#12 #12 0.50 540 1,260 720 0.50 #12 #12 ¾"EXAM RCPT -1 20 24 25 20 1 -EXAM RCPT ¾"#12 #12 0.50 720 2,160 1,440 0.50 #12 #12 ¾"HALL/RR RCPT -1 20 26 27 20 1 -CCM/EXAM RCPT ¾"#12 #12 0.50 720 1,800 1,080 0.50 #12 #12 ¾"OFFICE RCPTS -1 20 28 29 20 1 -NURSES STATION RCPT ¾"#12 #12 0.50 1,080 2,520 1,440 0.50 #12 #12 ¾"JANITOR/LOBBY RCPT -1 20 30 31 20 1 -EWC ¾"#12 #12 0.50 800 2,240 1,440 0.50 #12 #12 ¾"CHECK-IN RCPT -1 20 32 33 20 1 -DEDICATED COPIER RCPT ¾"#12 #12 0.50 1,000 2,080 1,080 0.50 #12 #12 ¾"X-RAY RCPT -1 20 34 35 20 1 -CHECK-OUT RCPT ¾"#12 #12 0.50 1,440 2,940 1,500 0.50 #12 #12 ¾"ADA DOORS -1 20 36 37 20 1 -DBF-1 ¾"#12 #12 0.50 120 1,560 1,440 0.50 #12 #12 ¾"ROOFTOP RCPT -1 20 38 39 20 1 -SPARE 1.00 0 1.00 SPARE -1 20 40 41 20 1 -SPARE 1.00 0 1.00 SPARE -1 20 42 400A 3P SUB-FEED CIRCUIT BREAKER PANEL L1B SEE ONE-LINE 1.00 40,045 40,045 --DIAGRAM FOR 1.00 32,790 32,790 -REQUIREMENTS 1.00 41,519 41,519 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.53,145 44,090 55,039 152,274 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 423 CONNECTED LOAD (A) ELECTRICAL CODE.-4,660 -3,790 -4,760 -13,210 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 48,485 40,300 50,279 139,064 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 404 336 419 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"419 MAXIMUM LOAD (A) 4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL 35%29%36%PHASE BALANCE EFFICIENCY CERTIFICATES PER IECC R401.3 5.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. PANEL SCHEDULE "L1B" VOLTAGE:208 Y/ 120 VOLTS BUS RATING (AMPS):400 REMARKS: MOUNTING:FLUSH PHASE:3 MAIN LUGS ONLY ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 -SPACE 1.00 540 540 0.50 #12 #12 ¾"X-RAY ROOM RCPT -1 20 2 3 -SPACE 1.00 720 720 0.50 #12 #12 ¾"EXAM ROOM RCPT -1 20 4 5 -SPACE 1.00 1,440 1,440 0.50 #12 #12 ¾"LAB RCPT -1 20 6 7 20 1 -OFFICE RCPT ¾"#12 #12 0.50 720 1,800 1,080 0.50 #12 #12 ¾"EXAM /HALL RCPT -1 20 8 9 20 1 -OFFICE RCPT ¾"#12 #12 0.50 720 1,440 720 0.50 #12 #12 ¾"OFFICE RCPT -1 20 10 11 20 1 -HALL/RR RCPT ¾"#12 #12 0.50 1,440 2,520 1,080 0.50 #12 #12 ¾"KIDS WAIT/REC RCPT -1 20 12 13 20 1 -OFFICE RCPT ¾"#12 #12 0.50 720 1,440 720 0.50 #12 #12 ¾"PT OFFICE RCPT -1 20 14 15 20 1 -WASHER ¾"#12 #12 1.00 1,200 2,640 1,440 0.50 #12 #12 ¾"LOCKER/JANITOR RCPT -1 20 16 17 50 2 -RANGE ¾"#8 #10 0.50 4,000 6,500 2,500 1.00 #10 #8 ¾"DRYER -2 40 18 19 -----#8 -0.50 4,000 6,500 2,500 1.00 -#8 -----20 21 20 1 -ADL COUNTER RCPT ¾"#12 #12 0.50 360 1,860 1,500 0.50 #12 #12 ¾"D-WASHER/DISPOSAL -1 20 22 23 20 1 -BREAK MICROWAVE ¾"#12 #12 0.50 1,000 2,200 1,200 0.50 #12 #12 ¾"BREAK FRIDGE -1 20 24 25 20 1 -COPIER/CHART RCPT ¾"#12 #12 0.50 1,080 1,800 720 0.50 #12 #12 ¾"ADL/SENSORY RCPT -1 20 26 27 20 1 -VESTIBULAR/K GYM RCPT ¾"#12 #12 0.50 1,080 2,520 1,440 0.50 #12 #12 ¾"K GYM RECPT/STORAGE RCPT -1 20 28 29 20 1 -RECPT/PT RCPT ¾"#12 #12 0.50 1,080 2,160 1,080 0.50 #12 #12 ¾"PT/ADULYGYM RCPT -1 20 30 31 20 1 -PROCEDURE RCPT ¾"#12 #12 0.50 900 2,340 1,440 0.50 #12 #12 ¾"WAITING/RECPT RCPT -1 20 32 33 20 1 -DRUG SCREEN,RR RCPT ¾"#12 #12 0.50 1,080 1,800 720 0.50 #12 #12 ¾"EXAM RCPT -1 20 34 35 20 1 -EXAM RCPT ¾"#12 #12 0.50 720 1,440 720 0.50 #12 #12 ¾"EXAM/DR RCPT -1 20 36 37 20 1 -EXAM RCPT ¾"#12 #12 0.50 1,080 2,080 1,000 0.50 #12 #12 ¾"BREAK DISPOSAL RCPT -1 20 38 39 20 1 -BREAK FRIDGE ¾"#12 #12 0.50 1,200 1,560 360 0.50 #12 #12 ¾"BREAK COUNTER RCPT -1 20 40 41 20 1 -BREAKROOM MIROWAVE ¾"#12 #12 0.50 1,200 2,280 1,080 0.50 #12 #12 ¾"NAC RED 1 20 42 43 20 1 -RX ROOM RCPT ¾"#12 #12 0.50 1,080 2,160 1,080 0.50 #12 #12 ¾"NURSES STATION RCPT -1 20 44 45 20 1 -RX FRIDGE ¾"#12 #12 0.50 1,200 1,740 540 0.50 #12 #12 ¾"SPRINKLER BELL RED 1 20 46 47 20 1 -EWH-1 ¾"#12 #12 1.00 1,500 2,500 1,000 0.50 #12 #12 ¾"PT FREEZER RCPT -1 20 48 49 20 1 -EWH-1 ¾"#12 #12 1.00 1,500 3,000 1,500 1.00 #12 #12 ¾"EWH-1 -1 20 50 51 20 1 -UH-1 ¾"#12 #12 0.50 300 1,560 1,260 0.50 #12 #12 ¾"ROOFTOP RCPT -1 20 52 53 20 1 -DEDICATED COPIER RCPT ¾"#12 #12 0.50 1,080 1,080 1.00 SPARE -1 20 54 55 20 1 -SPARE 1.00 0 1.00 SPARE -1 20 56 200A 3P SUB-FEED CIRCUIT BREAKER PANEL L1C SEE ONE-LINE 1.00 18,385 18,385 --DIAGRAM FOR 1.00 16,950 16,950 -REQUIREMENTS 1.00 19,399 19,399 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.40,045 32,790 41,519 114,354 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 317 CONNECTED LOAD (A) ELECTRICAL CODE.-8,080 -7,320 -9,060 -24,460 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 31,965 25,470 32,459 89,894 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 266 212 270 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"270 MAXIMUM LOAD (A) 4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL 36%28%36%PHASE BALANCE EFFICIENCY CERTIFICATES PER IECC R401.3 5.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. PANEL SCHEDULE "L1C" VOLTAGE:208 Y/ 120 VOLTS BUS RATING (AMPS):225 REMARKS: MOUNTING:FLUSH PHASE:3 MAIN LUGS ONLY ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 20 1 -F-3.5 ¾"#12 #12 1.00 1,380 2,760 1,380 1.00 #12 #12 ¾"F-4 -1 20 2 3 20 1 -F-3 ¾"#12 #12 1.00 1,200 2,400 1,200 1.00 #12 #12 ¾"F-3 -1 20 4 5 20 1 -F-5 ¾"#12 #12 1.00 2,040 5,607 3,567 1.00 #10 #8 ¾"CU-5 -2 50 6 7 30 2 -CU-3 ¾"#10 #10 1.00 1,862 5,429 3,567 1.00 -#8 -----8 9 -----#10 -1.00 1,862 4,056 2,194 1.00 #10 #10 ¾"CU-4 -2 30 10 11 30 2 -CU-3.5 ¾"#10 #10 1.00 2,236 4,430 2,194 1.00 -#10 -----12 13 -----#10 -1.00 2,236 4,108 1,872 1.00 #10 #10 ¾"CU-24 -2 30 14 15 60 2 -CU-42 1"#6 #10 1.00 4,368 6,240 1,872 1.00 -#10 -----16 17 -----#6 -1.00 4,368 4,608 240 1.00 #12 #12 ¾"CP-1 -1 20 18 19 20 1 -EF-2,4,5 ¾"#12 #12 1.00 1,632 3,048 1,416 1.00 #12 #12 ¾"EF-3,4 -1 20 20 21 20 2 -CU-18 ¾"#12 #12 1.00 1,352 3,214 1,862 1.00 #10 #10 ¾"CU-3 -2 30 22 23 -----#12 -1.00 1,352 3,214 1,862 1.00 -#10 -----24 25 20 2 -WM & FC 09,18 ¾"#12 #12 1.00 624 1,040 416 1.00 #12 #12 ¾"WM18,24 -2 20 26 27 ----#12 -1.00 624 1,040 416 1.25 -#12 -----28 29 20 1 -ROOFTOP RCPT ¾"#12 #12 0.50 540 1,540 1,000 1.25 #12 #12 ¾"SIGNAGE (LCP-6)-1 20 30 31 20 1 -RFAA PANEL ¾"#12 #12 0.50 1,000 2,000 1,000 1.00 #12 #12 ¾"SIGNAGE (LCP-7)-1 20 32 33 -SPACE 1.00 0 1.00 SPACE -34 35 -SPACE 1.00 0 1.00 SPACE -36 37 -SPACE 1.00 0 1.00 SPACE -38 39 -SPACE 1.00 0 1.00 SPACE -40 41 -SPACE 1.00 0 1.00 SPACE -42 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.18,385 16,950 19,399 54,734 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 152 CONNECTED LOAD (A) ELECTRICAL CODE.-500 104 -20 -416 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 17,885 17,054 19,379 54,318 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 149 142 161 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"161 MAXIMUM LOAD (A) 4.E.C. SHALL COORDINATE WITH HVAC CONTRACTOR FOR PLACEMENT OF PANEL 33%31%36%PHASE BALANCE EFFICIENCY CERTIFICATES PER IECC R401.3 5.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 6.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E6 . 2 CD RB EL E C T R I C A L SC H E D U L E S EQUIPMENT SCHEDULE SYMBOL DESCRIPTION SERVICE DISCONNECT STARTER LOAD REMARKSVOLTSPHASESIZEFUSEHP/TON VA AMPS F 3 FURNACE FAN 120 V 1Ø MANUAL STARTER -INTEGRAL -1,200 10.0A F 3.5 FURNACE FAN 120 V 1Ø MANUAL STARTER -INTEGRAL -1,380 11.5A F 4 FURNACE FAN 120 V 1Ø MANUAL STARTER -INTEGRAL -1,380 11.5A F 5 FURNACE FAN 120 V 1Ø MANUAL STARTER -INTEGRAL -2,040 17.0A CU 3 AIR COOLED CONDENSING UNIT 208 V 1Ø 30A NEMA 3R -INTEGRAL 3 TON 3,723 17.9A CU 3.5 AIR COOLED CONDENSING UNIT 208 V 1Ø 30A NEMA 3R -INTEGRAL 3½ TON 4,472 21.5A CU 4 AIR COOLED CONDENSING UNIT 208 V 1Ø 30A NEMA 3R -INTEGRAL 4 TON 4,389 21.1A CU 5 AIR COOLED CONDENSING UNIT 208 V 1Ø 60A NEMA 3R -INTEGRAL 5 TON 7,134 34.3A CU 18 AIR COOLED CONDENSING UNIT 208 V 1Ø 30A NEMA 3R -INTEGRAL 1½ TON 2,704 13.0A CU 24 AIR COOLED CONDENSING UNIT 208 V 1Ø 30A NEMA 3R -INTEGRAL 2 TON 3,744 18.0A CU 42 AIR COOLED CONDENSING UNIT 208 V 1Ø 60A NEMA 3R -INTEGRAL 3½ TON 8,736 42.0A WM 09 WALL MOUNT INDOOR UNIT 208 V 1Ø 2 POLE SWITCH -INTEGRAL 1½ TON 208 1.0A CONTROLLED BY OUTDOOR UNIT WM 18 WALL MOUNT INDOOR UNIT 208 V 1Ø 2 POLE SWITCH -INTEGRAL 1½ TON 250 1.2A CONTROLLED BY OUTDOOR UNIT FC 18 DUCTED FAN COIL 208 V 1Ø 2 POLE SWITCH -INTEGRAL 1½ TON 250 1.2A CONTROLLED BY OUTDOOR UNIT WM 24 WALL MOUNT INDOOR UNIT 208 V 1Ø 2 POLE SWITCH -INTEGRAL 1½ TON 416 2.0A CONTROLLED BY OUTDOOR UNIT RTU 4 ROOF TOP UNIT 480 V 3Ø 30A NEMA 3R -INTEGRAL 12,471 15.0A RTU 5 ROOF TOP UNIT 480 V 3Ø 30A NEMA 3R -INTEGRAL 13,635 16.4A FACTORY INSTALLED TRCRPTACLE AND DISCONNECT EF 1 EXHAUST FAN 120 V 1Ø INTEGRAL PLUG --FRAC 120 1.0A EF CONTROLLED WITH LIGHTING EF 2 EXHAUST FAN 120 V 1Ø INTEGRAL PLUG --FRAC 240 2.0A SEE PLAN FOR EF CONTROL EF 3 EXHAUST FAN 120 V 1Ø INTEGRAL PLUG --FRAC 360 3.0A SEE PLAN FOR EF CONTROL EF 4 EXHAUST FAN 120 V 1Ø INTEGRAL PLUG --¼ HP 696 5.8A EF SHALL OPERATE WHILE BUILDING IS OCCUPIED EF 5 EXHAUST FAN 120 V 1Ø INTEGRAL PLUG --¼ HP 696 5.8A EF SHALL OPERATE WHILE BUILDING IS OCCUPIED DBF 1 DRYER BOOST FAN 120 V 1Ø INTEGRAL PLUG --FRAC 120 1.0A SHALL BE INTERLOCKED TO RUN DURING DRYER OPERATION EWH 1 ELECTRIC WALL HEATER 120 V 1Ø T-STAT ---1,500 12.5A UH 1 UNIT HEATER 120 V 1Ø MANUAL STARTER ---300 2.5A CP 1 RECIRCULATION PUMP 120 V 1Ø PLUG/ CORD --FRAC 240 2.0A NOTES: 1.VERIFY ALL EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS (i.e. VOLTAGE, PHASE, FLA, ETC.) WITH MECHANICAL DRAWINGS/SUBMITTALS BEFORE FOR ACTUAL EQUIPMENT INSTALLED. 2.ALL FUSES SHALL BE DUAL ELEMENT TIME DELAY. FINAL BREAKER/FUSE & DISCONNECT SIZE SHALL BE DETERMINED BY MANUFACTURER'S RECOMMENDATION FOR ACTUAL EQUIPMENT INSTALLED. 3.MAXIMUM VALUES INDICATED. 4.DISCONNECTING MEANS NOT REQUIRED FOR EQUIPMENT WITHIN SIGHT (AS DEFINED IN NEC) OF BRANCH PANEL SERVING EQUIPMENT. SEE NEC 422.31 (B). LIGHT FIXTURE SCHEDULE FIXTURE NUMBER FIXTURE MANUFACTURER FIXTURE CATALOG # LAMPS FIXTURE DESCRIPTION REMARKSTYPEQTY.VOLTS WATTS MOUNTING F1 HALO COMMERCIAL LITHONIA LIGHTOLIER ATLANTIC PRESCOLITE MAXILUME LD6B10D010/EU6B10208035/6LBSW1LI LDN6 35/10 LW6AR LSS MVOLT EZ1 P6RD10NZ10UVB W/P6RD835VB W/P6RLWCC LED6WW-DLM11-35K-U-6LED80-SS LF6SLWW-6LFSL11L35KWW HH6-LED-1200L-DIM10-MVOLT-MD-35K-90/HH6-6507-CL-WH LED 3500 KELVIN 1000 LUMENS 80 CRI -277 21 RECESSED LED WALLWASHER WITH ALZAK TRIM F2 METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 4WSNLED-LD4-32SL-F-UNV-L835-CD1-U LBL4-3000LM-80CRI-35K-MIN1-ZT-MVOLT OWL-4-40L-835-UNIV-DIM WNA10-LED-SS-WW-UE LWC4-35LW-EDU 4-OIW-LED-3400L-DIM10-MVOLT-35K-80 LED 3500 KELVIN 3200 LUMENS 80 CRI -277 46 SURFACE CEILING 1X4 SURFACE LED F2E METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 4WSNLED-LD4-32SL-F-UNV-EL14W-L835-CD1-U LBL4-3000LM-80CRI-35K-MIN1-ZT-MVOLT-EL14L OWL-4-40L-835-UNIV-DIM-EMLED WNA10-LED-SS-WW-UE-EM LWC4-35LW-EDU-ELL14 4-OIW-LED-3400L-DIM10-MVOLT-35K-80-O-EMG-LED LED 3500 KELVIN 3200 LUMENS 80 CRI -277 46 SURFACE CEILING 1X4 SURFACE LED WITH EMERGENCY BATTERY PACK F3 METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 24FR-LD4-40-UNV-L835-CD1-U 2BLT4-48L-ADP-EZ1-LP835 2FGG48L835-4-D-UNV-DIM PEC24-LED-HO-RAD-WW-UE LTRE24-35MLG-RFA-EDU 24-OD-LED-4000L-DIM10-MVOLT-35K-80-O LED 3500 KELVIN 4000 LUMENS 8 CRI -277 55 LAY-IN GRID 2X4 LED LAY-IN VOLUMETRIC F4 LSI OR APPROVED EQUAL AUM S LED 14L 40 ACSF16 GWT LED -277 108 SUSPENDED LED HIGH BAY PENDANT F5 METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 4SNLED-LD4-30SL-LW-UNV-L835-CD1-U ZL1N-L48-3000LM-FST-MVOLT-35K-80CRI-WH FSS440L835-UNV-DIM SDL-4-LED-SS-WW-UE LCL4-35LW-EDU 4-OC1-LED-3000L-DIM10-MVOLT-35K-80 LED 3500 KELVIN 3000 LUMENS 80 CRI -277 29 SURFACE 48" LED STRIP EG SURELITE LITHONIA PROLITE LSI DUAL-LITE MAXILUME SELW25XX AFN-DB-EXT DBEL-ACEM-W-SDT-CW CSN-DB-CT PGZ-HTR ELM-807-BZ 6W XENON INCLUDED 2 277 12 SURFACE WALL EMERGENCY EGRESS LIGHT FINISH TO BE SELECTED BY ARCHITECT EM SURELITE LITHONIA LIGHTOLIER LSI DUAL-LITE MAXILUME SEL17 ELM2 E611W LTEM-WH EZ-2 ELM-LED-861 INCLUDED 2 277 5.4 SURFACE WALL 2-HEAD EM WALL PACK (SURFACE) EX SURELITE LITHONIA CHLORIDE LSI DUAL-LITE MAXILUME APX7G LQM-S-W-3-G-EL-N ER55L3WG EX-G-U-WB-WH EVEUGWE ELX-603-G-W INCLUDED 2 277 1.5 UNIVERSAL UNIVERSAL MOUNT WITH EXTRA FACE PLATE FOR FIELD CONVERSION 1-2 FACE NICKEL/CADMIUM BATTERY SINGLE FACE EXIT LIGHTING CONTROL PANEL "LCP" SCHEDULE AUTOMATION SCHEDULE MOUNTING:FLUSH LOCATION: MECH ROOM WALL Sc h e d u l e O N / O F F Ma n u a l O N / A u t o O F F Du s k - D a w n Du s k - A u t o O F F 0- 1 0 V D i m m i n g Ph a s e D i m m i n g Da y l i g h t S e n s o r BRANCH CIRCUIT FOR CONTROL L1A-2 SPACE RELAY SUPPLY VA AREA SERVED LV SWITCH* NUMBER AMP POLE 1 20 1 H1A-3 330 COMMON HALLWAY X X X 2 20 1 H1A-5 1,080 PT GYM 3 20 1 H1A-5 1,080 PT GYM X X X 4 20 1 H1A-5 756 PT GYM X X X 5 20 1 H1A-5 540 PT GYM X X X 6 20 1 L1C-30 1,000 FRONT SIGNAGE X X 7 20 1 L1C-32 1,000 W SIDE SIGNAGE X X 8 20 1 --SPARE * SEE PLAN FOR LOCATION OF LOW VOLTAGE SWITCH MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E7 . 1 CD RB EL E C T R I C A L SP E C I F I C A T I O N ELECTRICAL SPECIFICATIONS GENERAL PROVISION A.REFERENCE 1.THE GENERAL CONDITIONS AND OTHER CONTRACT DRAWINGS AS SET FORTH IN THE FOREGOING PAGES ARE HEREBY INCORPORATED INTO AND BECOME A PART OF THE SPECIFICATIONS FOR WORK UNDER THIS TITLE, INSOFAR AS THEY APPLY HERETO. 2.ALL SPECIFICATIONS UNDER THIS DIVISION TITLE ARE DIRECTED TO AND ARE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR, UNLESS OTHER TRADES OR PERSONS ARE SPECIFICALLY MENTIONED, “ELECTRICAL CONTRACTOR” IS INFERRED AND INTENDED. B.CONTRACT DRAWINGS 1.THE DRAWINGS ACCOMPANYING THESE SPECIFICATIONS ARE COMPLEMENTARY EACH TO THE OTHER AND WHAT IS CALLED FOR BY ONE SHALL BE AS IF CALLED FOR BY BOTH. 2.CONSULT ALL CONTRACT DRAWINGS WHICH MAY AFFECT THE LOCATION OF EQUIPMENT, CONDUIT AND WIRING AND MAKE MINOR ADJUSTMENTS IN LOCATION TO SECURE COORDINATION. 3.WIRING LAYOUT IS SCHEMATIC AND EXACT LOCATIONS SHALL BE DETERMINED BY FIELD CONDITIONS. 4.OTHER THAN MINOR ADJUSTMENTS SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR APPROVAL BEFORE PROCEEDING WITH THE WORK. C.JOB-SITE COPY OF DOCUMENTS 1.MAINTAIN AT THE SITE, ONE COPY OF ALL DRAWINGS, SPECIFICATIONS, ADDENDA APPROVED SHOP DRAWINGS, CHANGE ORDERS AND OTHER MODIFICATIONS, IN GOOD ORDER AND MARKED TO RECORD ALL CHANGES MADE DURING CONSTRUCTION. THESE SHALL BE AVAILABLE TO THE OWNER'S REPRESENTATIVE. THE DRAWINGS MARKED TO RECORD ALL CHANGES MADE DURING CONSTRUCTION SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE FOR THE OWNER UPON COMPLETION OF THE WORK. AN ADDITIONAL SET OF DRAWINGS WILL BE FURNISHED BY THE OWNER'S REPRESENTATIVE FOR THIS PURPOSE UPON REQUEST. D.MANUFACTURER'S DRAWINGS 1.THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT FOR REVIEW. (6) COPIES OF MANUFACTURER'S DRAWINGS AND WIRING DIAGRAMS. THE ENGINEER WILL REVIEW CONTRACTOR'S SHOP DRAWINGS AND RELATED SUBMITTALS (AS INDICATED BELOW) WITH RESPECT TO THE ABILITY OF THE DETAILED WORK, WHEN COMPLETE, TO BE A PROPERLY FUNCTIONING INTEGRAL ELEMENT OF THE OVERALL SYSTEM DESIGNED BY THE ENGINEER. BEFORE SUBMITTING A SHOP DRAWING OR ANY RELATED MATERIAL TO THE ENGINEER, CONTRACTOR SHALL: REVIEW EACH SUCH SUBMISSION FOR CONFORMANCE WITH THE MEANS, METHODS, TECHNIQUES, SEQUENCES,AND OPERATIONS OF CONSTRUCTION, AND SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO, ALL OF WHICH ARE THE SOLE RESPONSIBILITY OF CONTRACTOR: APPROVE EACH SUCH SUBMISSION BEFORE SUBMITTING IT; AND SO STAMP EACH SUCH SUBMISSION BEFORE SUBMITTING IT. THE ENGINEER SHALL ASSUME THAT NO SHOP DRAWING OR RELATED SUBMITTAL COMPRISES A VARIATION UNLESS CONTRACTOR ADVISES ENGINEER OTHERWISE VIA A WRITTEN INSTRUMENT WHICH IS ACKNOWLEDGED BY ENGINEER IN WRITING. THE ITEMS, TYPES OF SUBMITTALS AND RELATED MATERIAL (IF ANY) CALLED FOR ARE INDICATED BELOW: ITEMS TYPE SUBMITTALS REQUESTED LIGHTING AND POWER PANELS SHOP DRAWINGS LIGHTING FIXTURES CATALOG CUTS E.GUARANTEES 1.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEFECTS, REPAIRS AND REPLACEMENTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF SUBSTANTIAL COMPLETION AS DETERMINED BY THE OWNER'S REPRESENTATIVE. PRODUCT GUARANTEES GREATER THAN ONE (1) YEAR SHALL BE PASSED ALONG TO THE OWNER FOR FULL BENEFIT OF THE MANUFACTURER'S WARRANTY. WORK INCLUDED A.INSTALLATION, MATERIALS, AND WORKMANSHIP 1.FURNISH AND INSTALL ALL NECESSARY ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS AND OTHER SIMILAR APPURTENANCES NOT INDICATED ON THE DRAWINGS BUT WHICH ARE REQUIRED FOR A COMPLETE AND PROPERLY INSTALLED SYSTEM CONSISTENT WITH THE ARCHITECTURAL TREATMENT OF THE BUILDING. 2.THE ELECTRICAL CONTRACTOR, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION. AND AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY DEBRIS AND EXCESS MATERIALS. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF DUMPSTER & REFUSED DISPOSAL AS REQUIRED FOR ELECTRICAL WORK. 3.ALL MATERIALS SHALL BE NEW AND UNDETERIORATED AND OF A QUALITY NOT LESS THAN THE MINIMUM SPECIFIED. B.COORDINATION OF PLANS AND SPECIFICATIONS 1.CONTACT THE OWNER'S REPRESENTATIVE IMMEDIATELY IF THERE IS ANY QUESTIONS REGARDING THE MEANING OR INTENT OF EITHER PLANS OR SPECIFICATIONS, OR UPON NOTICING ANY DISCREPANCIES OR OMISSIONS IN EITHER PLANS OR SPECIFICATIONS. C.CUTTING AND PATCHING 1.ALL ELECTRICAL EQUIPMENT SHALL BE KEPT DRY AND CLEAN DURING THE CONSTRUCTION PERIOD. INTERIOR OF ALL ENCLOSURES SHALL BE CLEANED OF DIRT AND DEBRIS BEFORE INSTALLING TRIM OR COVERS. 2.ALL FINISHED SURFACES OF EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL BE THOROUGHLY CLEANED OF DIRT AND ALL SCRATCHED OR DAMAGED SURFACES SHALL BE TOUCHED UP WITH MATCHING MATERIALS BEFORE FINAL ACCEPTANCE OF THE WORK. 3.WHEN ALL WORK IS COMPLETED AND ALL WORK HAS BEEN SATISFACTORILY TESTED AND ACCEPTED BY THE OWNER'S REPRESENTATIVE, ALL CONDUIT AND OTHER EXPOSED SURFACES SHALL BE THOROUGHLY CLEANED. CODES AND FEES A.CODES: 1.ALL WORK PERFORMED UNDER THIS SPECIFICATION SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AS PREPARED AND PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION AND ANY APPLICABLE STATE OR LOCAL CODES. B.FEES: 1.OBTAIN AND PAY FOR ANY AND ALL PERMITS REQUIRED BY ALL LAWS AND REGULATIONS AND PUBLIC AUTHORITY HAVING SUCH JURISDICTION. TESTS AND INSPECTIONS A.OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES, RULES, REGULATIONS OR PUBLIC AUTHORITY HAVING JURISDICTION AND OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE OWNER'S REPRESENTATIVE. PAY ALL FEES, CHARGES AND OTHER EXPENSES IN CONNECTION THEREIN. OBTAIN OCCUPANCY PERMIT AS REQUIRED BY OWNER. FINAL PAYMENT SHALL NOT BE MADE UNTIL OCCUPANCY PERMIT IS OBTAINED. B.WORK SHALL BE UNACCEPTABLE WHEN FOUND TO BE DEFECTIVE OR CONTRARY TO THE PLANS SPECIFICATIONS, CODES SPECIFIED OR ACCEPTED STANDARDS OF GOOD WORKMANSHIP. C.THE CONTRACTOR SHALL PROMPTLY CORRECT ALL WORK FOUND UNACCEPTABLE BY THE OWNER'S REPRESENTATIVE WHETHER OBSERVED BEFORE OR AFTER SUBSTANTIAL COMPLETION AND WHETHER OR NOT FABRICATED, INSTALLED OR COMPLETED. THE CONTRACTOR SHALL BEAR ALL COSTS OF CORRECTING SUCH UNACCEPTABLE WORK, INCLUDING COMPENSATION FOR THE OWNERS REPRESENTATIVE ADDITIONAL SERVICES MADE NECESSARY THEREBY. CONDUIT A.FURNISH AND INSTALL ALL CONDUITS, BOXES, FITTINGS, ETC., FOR A COMPLETE RACEWAY SYSTEM. B.ALL WIRING SHALL BE RUN IN EMT CONDUIT OR MC CABLE WITH GROUND CONDUCTOR UNLESS OTHERWISE NOTED. C.ALL CONDUIT SIZES STATED HEREIN OR MARKED ON THE DRAWINGS ARE MINIMUM SIZE AND SHALL BE NO LESS THAN 12" UNLESS OTHERWISE NOTED. D.ALL CONDUIT SHALL BE SUBSTANTIALLY SUPPORTED BY PIPE STRAPS OR SUITABLE CLAMPS OR HANGERS ATTACHED TO THE ELEMENTS OF THE BUILDING STRUCTURE TO PROVIDE RIGID INSTALLATION; IN NO CASE SHALL CONDUIT BE ATTACHED OR SUPPORTED FROM ADJOINING PIPE OR INSTALLED IN SUCH A MANNER AS TO PREVENT THE READY REMOVAL OF OTHER PIPE FOR REPAIRS. WIRE AND CABLE A.ALL CONDUCTORS SHALL BE COPPER AND OF THE AWG SIZE AND TYPE SHOWN ON THE DRAWINGS. WHERE NO SIZE OR TYPE IS SHOWN. CONDUCTORS SHALL NOT BE LESS THAN #12 TYPE XHHW, THHN, OR THWN. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED COPPER AND HAVE 600 VOLT INSULATION; BE UL LABELED AND OF AMERICAN MANUFACTURER. B.ALL BRANCH CIRCUITS IN PATIENT CARE AREAS SHALL BE MEDICAL GRADE MC CABLE. ALL BRANCH CIRCUITS IN OFFICE AND COMMON AREAS SHALL BE TYPE MC CABLE. C.ALL CONNECTIONS ARE TO BE MADE USING PRESSURE TYPE TERMINALS. D.THE FOLLOWING COLOR CODE SHALL BE USED: 120/240 VOLT 120/208 VOLT 277/480 VOLT PHASE A BLACK BLACK BROWN PHASE B RED RED ORANGE PHASE C BLUE YELLOW NEUTRAL WHITE WHITE WHITE GROUND GREEN GREEN GREEN E.CONDUCTORS NO. 10 AWG OR SMALLER SHALL HAVE INSULATION COLORED AS NOTED ABOVE. F.CONDUCTORS NO. 8 AWG OR LARGER SHALL HAVE INSULATION COLORED AS NOTED ABOVE OR COLORED TAPE, MINIMUM SIZE 12'', WRAPPED TWICE AROUND AT THE FOLLOWING POINTS: 1.AT EACH TERMINAL. 2.AT EACH CONDUIT ENTRANCE. 3.AT INTERVALS NOT MORE THAN 12 INCHES APART IN ALL BOXES, PANEL TUBS, SWITCHBOARDS, ETC. G.ALL BRANCH CIRCUITS SHALL BE MARKED IN THE PANEL BOARD GUTTERS. MARKERS SHALL INDICATE CORRESPONDING BRANCH--CIRCUIT NUMBERS. H.EACH BRANCH CIRCUIT REQUIRING A NEUTRAL SHALL BE FURNISHED WITH A SEPARATE INDIVIDUAL NEUTRAL CONDUCTOR. BOXES AND PLATES A.FURNISH AND INSTALL ALL OUTLET, JUNCTION, AND PULL BOXES AS INDICATED ON THE DRAWINGS AND AS NECESSARY TO INSTALL THE REQUIRED CONDUIT AND WIRING IN A NEAT AND WORKMANLIKE MANNER. B.PULL BOXES AND JUNCTION BOXES SHALL BE GALVANIZED AND OF THE CORRECT SIZE AND GAUGE, SIZED IN ACCORDANCE WITH CODE REQUIREMENTS AND SHALL BE U.L. LABELED. C.BOXES AT EXTERIOR AREAS TO BE WATERTIGHT AND DUST-TIGHT WITH CASKETED COVERS. D.ALL BOXES FOR EXPOSED WORK IN FINISHED SPACES SHALL BE ''FS'' TYPE WITH THREADED HUBS WITH RIGID CONDUIT RISER (DEEP WIRE MOLD BOXES). E.ALL BOXES SHALL BE RIGIDLY SUPPORTED INDEPENDENT OF THE CONDUIT SYSTEM. BOXES CAST INTO MASONRY OR CONCRETE ARE CONSIDERED TO BE RIGIDLY SUPPORTED. F.FLOOR BOXES: 1.DESCRIPTION: FLOOR BOXES COMPATIBLE WITH FLOOR BOX SERVICE FITTINGS PROVIDED IN ACCORDANCE WITH THE WIRING DEVICES SECTION OF THIS SPECIFICATION; WITH PARTITIONS TO SEPARATE MULTIPLE SERVICES; FURNISHED WITH ALL COMPONENTS, ADAPTERS, AND TRIMS REQUIRED FOR COMPLETE INSTALLATION. 2.USE CAST IRON OR NONMETALLIC FLOOR BOXES WITHIN SLAB ON GRADE. 3.USE SHEET-STEEL, CAST IRON, OR NONMETALLIC FLOOR BOXES WITHIN SLAB ABOVE GRADE. 4.METALLIC FLOOR BOXES: FULLY ADJUSTABLE (WITH INTEGRAL MEANS FOR LEVELING ADJUSTMENT PRIOR TO AND AFTER CONCRETE POUR). 5.MANUFACTURER: SAME AS MANUFACTURER OF FLOOR BOX SERVICE FITTINGS. G.UNDERGROUND BOXES/ENCLOSURES: 1.DESCRIPTION: IN-GROUND, OPEN BOTTOM BOXES FURNISHED WITH FLUSH, NON-SKID COVERS WITH LEGEND INDICATING TYPE OF SERVICE AND STAINLESS STEEL TAMPER RESISTANT COVER BOLTS. 2.SIZE: AS INDICATED ON DRAWINGS. 3.DEPTH: AS REQUIRED TO EXTEND BELOW FROST LINE TO PREVENT FROST UPHEAVAL, BUT NOT LESS THAN 12 INCHES. 4.APPLICATIONS: a.SIDEWALKS AND LANDSCAPED AREAS SUBJECT ONLY TO OCCASIONAL NONDELIBERATE VEHICULAR TRAFFIC: USE POLYMER CONCRETE OR COMPOSITE ENCLOSURE WITH MINIMUM SCTE 77, TIER 8 LOAD RATING. b.PARKING LOTS, IN AREAS SUBJECT ONLY TO OCCASIONAL NONDELIBERATE VEHICULAR TRAFFIC: USE POLYMER CONCRETE OR COMPOSITE ENCLOSURE WITH MINIMUM SCTE 77, TIER 15 LOAD RATING. c.DO NOT USE POLYMER CONCRETE ENCLOSURES IN AREAS SUBJECT TO DELIBERATE VEHICULAR TRAFFIC. H.COMPOSITE UNDERGROUND BOXES/ENCLOSURES: COMPLY WITH SCTE 77. WIRING DEVICES A.WIRING DEVICES SHALL BE SIMILAR TO THOSE LISTED BELOW AND OF SPECIFIED AMPERAGE. OTHER SPECIAL PURPOSE DEVICES SHALL BE AS SPECIFIED ON THE DRAWINGS. B.DUPLEX GROUNDING TYPE RECEPTACLE - 20 AMP, 125 VOLT 1.HUBBELL 5352 2.ARROW HART 5352 C.SINGLE POLE SWITCHES - 20 AMP, 120 VOLT D.WEATHERPROOF RECEPTACLES - 20 AMP, 125 VOLT - NEMA 5-20R 1.HUBBELL 5352 WITH 5205 COVER INTERMATIC GUARDIAN 2.I SERIES, NEMA 3R COVER 3.ARROW HART 5352 WITH 4500 COVER E.G.F.C.I. RECEPTACLE - 20 AMP, 125 VOLT - NEMA 5-20 R 1.HUBBELL GF 5262 WITH MATCHING NYLON COVER PLATE OR WO-26 W.P. COVER F.GROUND ALL RECEPTACLES IN ACCORDANCE WITH ARTICLE 250.146 OF NEC AND AS INDICATED IN THE GROUNDING SECTION OF THIS SPECIFICATION. IDENTIFICATION A.EACH PIECE OF SERVICE EQUIPMENT AND INDIVIDUAL SWITCHES, ALL DISCONNECTS, STARTERS, ALL EXHAUST FAN MANUAL STARTING SWITCHES. B.IDENTIFICATION SHALL BE IN THE FORM OF LAMINATED PLASTIC NAMEPLATES, BLACK RACE, WITH THE LETTERS ENGRAVED INTO THE WHITE BACKGROUND, MINIMUM ¼'' HIGH. PLATES SHALL BE DRILLED ON EACH END FOR SHEET METAL SCREW ATTACHMENT. NO “DYMO” OR SIMILAR TYPE LABELS WILL BE ALLOWED. C.PANEL BOARD DIRECTORY: A TYPED CIRCUIT DIRECTORY SHALL BE PROVIDED INDICATING LOCAL AREA SERVED AND LOCATION FOR EACH BRANCH CIRCUIT. GROUNDING A.ALL FEEDERS AND BRANCH CIRCUITS OVER 100 VOLTS SHALL INCLUDE A GROUNDING CONDUCTOR SIZED IN ACCORDANCE WITH NEC TABLE 250-122, EXCEPT NOT BE SMALLER THAN #12 FOR POWER AND LIGHTING CIRCUITS AND #14 FOR CONTROL CIRCUITS. ALL GROUND CONDUCTORS SHALL BE GREEN, OR AS SPECIFIED UNDER THE WIRE AND CABLE SECTION OF THIS SPECIFICATION. B.ALL GROUND CLAMPS SHALL BE PENN-UNION “GPL” TYPE OR SIMILAR BY O.Z. OR BURNDY. C.CONDUIT FOR SOLITARY GROUND CONDUCTORS SHALL BE RIGID SCHEDULE 40 PVC NON- METALLIC ELECTRICAL CONDUIT WITH U.L. LABEL SOLITARY GROUND CONDUCTORS SHALL NOT BE PLACED THROUGH METALLIC SLEEVES OR CONDUITS AND SHALL NOT BE COMPLETELY ENCIRCLED BY METALLIC HANGERS OR SUPPORTS. D.THE GROUND CONDUCTOR SHALL BE CONNECTED TO THE NEUTRAL IN ONLY TWO LOCATIONS -ON THE SUPPLY SIDE OF THE SERVICE DISCONNECT MEANS PER NEC--250--24 AND ON SEPARATELY DERIVED SYSTEMS PER NEC 250-30. E.AT EACH RECEPTACLE BOX, THE GROUND CONDUCTOR SHALL ENTER AND CONNECT, WITH NORMAL WIRING CONNECTOR, TO: 1) THE GROUND PIGTAIL TO RECEPTACLE: 2) THE GROUND PIGTAIL TO THE BOX GROUND SCREW; AND 3) THE OUTGOING GROUND CONDUCTOR TO NEXT DEVICE, IF NOT AT END OF RUN. METAL TO METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE. MOUNTED BOXES OR FLUSH TYPE BOXES. F.CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS SHALL CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON-CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. WHERE REDUCING WASHERS ARE USED AND WHERE CONCENTRIC OR ECCENTRIC KNOCKOUTS ARE NOT COMPLETELY REMOVED BONDING BUSHINGS SHALL BE REQUIRED. POWER AND LIGHTING PANELS A.FURNISH AND INSTALL, AS SCHEDULED AND SHOWN ON THE DRAWINGS, POWER PANELS FOR OPERATION ON VOLTAGES INDICATED. B.ALL TERMINATIONS SHALL BE MARKED “75°C ONLY”, “60/75° C” OR LISTED FOR USE OF 75° C INSULATED CONDUCTORS AT FULL 75° C AMPACITY. C.ALL BUS BARS SHALL BE SILVER OR TIN PLATED COPPER. D.CABINETS SHALL BE OF COMMERCIAL GALVANIZED SHEET STEEL, CODE GAUGE AND SIZE, SURFACE OR RECESSED MOUNTED AS CALLED FOR IN THE DRAWINGS. E.NEUTRAL ASSEMBLY SHALL HAVE INDIVIDUAL ANTI-TURN SOLDERLESS TERMINALS, SIMILAR TO SQUARE D TYPE PK, FOR CONNECTION OF ULTIMATE NUMBER OF NEUTRAL WIRES. SHEET METAL TERMINAL STRIPS AND CONNECTIONS WILL BE REJECTED. F.PANEL SHALL HAVE A COPPER GROUND BAR SIMILAR TO NEUTRAL BAR IN NUMBER, SIZE, AND TYPE OF ANTI-TURN SOLDERLESS LUGS. THIS GROUND BAR SHALL BE FACTORY BONDED TO THE PANEL TUB IN THE GUTTER SPACE OPPOSITE THE MAINS AND THE NEUTRAL ASSEMBLY AND SHALL HAVE THE SCREWDRIVER SLOTS FACING THE FRONT OF THE PANEL. G.QUALITY STANDARD: SQUARE D TYPE NF (480V) OR NQ (208V). LIGHTING FIXTURES A.CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING FIXTURES AS INDICATED IN FIXTURE SCHEDULE SHOWN ON DRAWINGS, AND SPECIFIED HEREIN. B.NEUTRAL ASSEMBLY SHALL HAVE INDIVIDUAL ANTI-TURN SOLDERLESS TERMINALS, SIMILAR TO SQUARE D TYPE PK, FOR CONNECTION OF ULTIMATE NUMBER OF NEUTRAL WIRES. SHEET METAL TERMINAL STRIPS AND CONNECTIONS WILL BE REJECTED. C.ALL LIGHTING FIXTURES INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE FURNISHED COMPLETE WITH AS INDICATED ON THE FIXTURE SCHEDULE. D.ANY LIGHTING FIXTURES SCRATCHED, BENT, CRACKED OR IN ANY WAY DAMAGED BEFORE ACCEPTANCE BY OWNER SHALL BE REPLACED AT THIS CONTRACTOR'S EXPENSE. E.ALL LIGHTING FIXTURES SHALL BE IN WORKING ORDER AT THE TIME OF FINAL ACCEPTANCE OF THE WORK BY THE OWNER. F.ALL LIGHTING FIXTURES ARE TO BE GROUNDED ON THE INTERIOR OF THE FIXTURE HOUSING, ON CLEAN BARE METAL (FREE OF PAINT). BY USE OF PIGTAIL AND FASTENED BY A SCREW USED FOR NO OTHER PURPOSE. ALARM & DETECTION SYSTEMS A.SUMMARY 1.INCLUDES BUT NOT LIMITED TO: FURNISH AND INSTALL MICROPROCESSOR-CONTROLLED, INTELLIGENT REPORTING FIRE ALARM EQUIPMENT REQUIRED TO FORM A COMPLETE COORDINATED SYSTEM THAT IS READY FOR OPERATION. B.SYSTEM DESCRIPTION 1.THE FIRE ALARM SYSTEM SHALL COMPLY WITH REQUIREMENTS OF NFPA STANDARD NO. 72 FOR PROTECTED PREMISES SIGNALING SYSTEMS EXCEPT AS MODIFIED AND SUPPLEMENTED BY THIS SPECIFICATION. THE SYSTEM SHALL BE ELECTRICALLY SUPERVISED AND MONITOR THE INTEGRITY OF ALL CONDUCTORS. 2.THE SYSTEM SHALL BE AN ACTIVE/INTERROGATIVE TYPE SYSTEM WHERE EACH DEVICE IS REPETITIVELY SCANNED, CAUSING A SIGNAL TO BE TRANSMITTED TO THE MAIN FIRE ALARM CONTROL PANEL (FACP) INDICATING THAT THE ASSOCIATED INITIATING DEVICE AND NOTIFICATION APPLIANCE CIRCUIT WIRING IS FUNCTIONAL. LOSS OF SUCH A SIGNAL AT THE MAIN FACP SHALL RESULT IN A TROUBLE INDICATION AS SPECIFIED HEREINAFTER FOR THE PARTICULAR INPUT. 3.SYSTEM OPERATION: OPERATION OF MANUAL STATION OR AUTOMATIC ACTIVATION OF ANY SMOKE DETECTOR SHALL: a.CAUSE SYSTEM EVACUATION HORNS TO SOUND AND LAMPS TO FLASH. b.THE 80 CHARACTER LCD DISPLAY SHALL INDICATE ALL INFORMATION ASSOCIATED WITH THE FIRE ALARM CONDITION, INCLUDING THE TYPE OF ALARM POINT AND ITS LOCATION WITHIN THE PROTECTED PREMISES. c.INITIATE OFF-SITE ALARM NOTIFICATION. d.RELEASE MAGNETIC DOOR HOLDERS. e.INITIATE SHUT DOWN OF MECHANICAL UNITS WITH AIR FLOW IN EXCESS OF 2000CFM. f.INITIATE CLOSURE OF ALL FIRE/SMOKE DAMPERS. 4.WIRING: THE MULTIPLEX BUSS AND DATA COMMUNICATION BUS (OPTIONS BUS) SHALL BE WIRED WITH STANDARD NEC 760 COMPLIANT WIRING. ALL FACP SCREW TERMINALS SHALL BE CAPABLE OF ACCEPTING 14 AWG (1.8 MM) TO 18 AWG (1.2 MM) WIRE. ALL SYSTEM WIRING SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 70, THE NATIONAL ELECTRICAL CODE (NEC) AND ALSO COMPLY WITH ARTICLE 760 OF THE NEC. C.QUALITY ASSURANCE 1.REGULATORY REQUIREMENTS a.SYSTEM SHALL MEET APPROVAL OF AUTHORITY HAVING JURISDICTION (AHJ). CHANGES OR ADDITIONS SHALL BE MADE TO THE SYSTEM AS REQUIRED WITHOUT ADDITIONAL COST TO OWNER. b.EQUIPMENT, DEVICES, AND CABLE SHALL BE UL OR FACTORY MUTUAL LISTED FOR USE IN FIRE ALARM SYSTEMS. c.DESIGNER QUALIFICATIONS: NICET LEVEL III OR IV (3 OR 4) CERTIFIED FIRE ALARM TECHNICIAN OR REGISTERED FIRE PROTECTION ENGINEER, EMPLOYED BY FIRE ALARM CONTROL PANEL MANUFACTURER, CONTRACTOR, OR INSTALLER. d.INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM 3 YEARS DOCUMENTED EXPERIENCE INSTALLING FIRE ALARM SYSTEMS OF THE SPECIFIED TYPE AND PROVIDING CONTRACT MAINTENANCE SERVICE AS A REGULAR PART OF THEIR BUSINESS. 1)AUTHORIZED REPRESENTATIVE OF CONTROL UNIT MANUFACTURER; SUBMIT MANUFACTURER'S CERTIFICATION THAT INSTALLER IS AUTHORIZED; INCLUDE NAME AND TITLE OF MANUFACTURER'S REPRESENTATIVE MAKING CERTIFICATION. 2)INSTALLER PERSONNEL: FACTORY TRAINED AND CERTIFIED WITH AT LEAST 2 YEARS OF EXPERIENCE INSTALLING FIRE ALARM SYSTEMS. 3)SUPERVISOR: NICET LEVEL III OR IV (3 OR 4) CERTIFIED FIRE ALARM TECHNICIAN; FURNISH NAME AND ADDRESS. D.FACP COMPONENTS: 1.EQUIPMENT AND ACCESSORIES FURNISHED UNDER TERMS OF THIS SPECIFICATION SHALL BE STANDARD PRODUCTS OF SINGLE MANUFACTURER, OR INCLUDE WRITTEN STATEMENT BY CONTROL PANEL MANUFACTURER CONFIRMING COMPATIBILITY OF COMPONENTS AND INCLUSION OF THESE COMPONENTS UNDER SYSTEM WARRANTY. 2.THE MAIN FACP CENTRAL CONSOLE SHALL CONTAIN A MICROPROCESSOR BASED CENTRAL PROCESSING UNIT (CPU). THE FACP SHALL COMMUNICATE WITH AND CONTROL THE FOLLOWING TYPES OF EQUIPMENT USED TO MAKE UP THE SYSTEM: ADDRESSABLE DETECTORS, ADDRESSABLE MODULES, LOCAL AND REMOTE OPERATOR TERMINALS, ANNUNCIATORS, AND OTHER SYSTEM CONTROLLED DEVICES. a.THE MAIN FACP AND CENTRAL CONSOLE SHALL PERFORM THE FOLLOWING FUNCTIONS: b.SUPERVISE AND MONITOR ALL ADDRESSABLE DETECTORS AND MONITOR MODULES CONNECTED TO THE SYSTEM FOR NORMAL, TROUBLE AND ALARM CONDITIONS. c.SUPERVISE ALL NOTIFICATION CIRCUITS THROUGHOUT THE FACILITY. d.VISUALLY AND AUDIBLY ANNUNCIATE ANY TROUBLE, SUPERVISORY OR ALARM CONDITION ON OPERATOR'S TERMINAL, PANEL DISPLAY, AND ANNUNCIATORS. 3.THE FIRE ALARM CONTROL PANEL SHALL INCLUDE A FULL FEATURED OPERATOR INTERFACE CONTROL AND ANNUNCIATION PANEL WHICH SHALL INCLUDE A BACKLIT LIQUID CRYSTAL DISPLAY, INDIVIDUAL, COLOR CODED SYSTEM STATUS LEDS, AND AN ALPHA-NUMERIC KEYPAD FOR FIELD PROGRAMMING AND CONTROL OF THE FIRE ALARM SYSTEM. 4.THE SYSTEM SHALL INCLUDE EMERGENCY EVACUATION SIGNAL UTILIZING INTELLIGENCE SUCH THAT LOSS OF OPERATION BY THE MAIN FACP WILL NOT RESULT IN THE LOSS OF EVACUATION SIGNAL THROUGHOUT THE BALANCE OF THE BUILDING. 5.THE MAIN COMMUNICATION BUS (OPTIONS BUS) SHALL BE CAPABLE OF CLASS A OR CLASS B CONFIGURATION WITH A TOTAL BUS LENGTH OF 5,900 FEET (1,798 M). 6.OFF-SITE ALARM NOTIFICATION SYSTEM a.PROVIDE TELEPHONE LINE CONNECTION FROM TELEPHONE TERMINAL BOARD TO FIRE ALARM CONTROL PANEL. b.PROVIDE DIALER DEVICE TO NOTIFY OFF-SITE PERSONNEL OF ALARM OR ABNORMAL CONDITIONS. c.CONNECT TO FIRE ALARM CONTROL PANEL SO SPECIFIED CONDITIONS INITIATE OFF-SITE CALL. USE ONE ALARM CODE FOR ALARM AND SECOND CODE FOR SUPERVISORY/TROUBLE ALARM. 7.AUDIBLE HORN ALARM ANNUNCIATION a.PROVIDE SEPARATE AND DISTINCT ALARM SIGNALS FOR ALARM AND TROUBLE CONDITIONS. b.ALARM SIGNAL SHALL ALSO OPERATE STROBE LIGHTS, IF SPECIFIED. c.PROVIDE ALARM SILENCE SWITCHES AT CONTROL PANEL. d.TROUBLE ALARM SHALL BE HORN INTEGRAL TO CONTROL PANEL. e.SUPERVISORY ALARM MAY BE SAME AUDIBLE ALARM AS TROUBLE ALARM, BUT WITH SEPARATE VISUAL ANNUNCIATION. E.FIELD MOUNTED SYSTEM COMPONENTS 1.FIRE ALARM INITIATING DEVICES a.DUCT DETECTOR HOUSING: PROVIDE SMOKE DETECTOR DUCT HOUSING ASSEMBLIES TO MOUNT AN ADDRESSABLE DETECTOR ALONG WITH A STANDARD, RELAY OR ISOLATOR DETECTOR MOUNTING BASE. THE HOUSING SHALL ALSO PROTECT THE MEASURING CHAMBER FROM DAMAGE AND INSECTS. THE HOUSING SHALL UTILIZE AN AIR EXHAUST TUBE AND AN AIR SAMPLING INLET TUBE THAT EXTENDS INTO THE DUCT AIR STREAM UP TO TEN FEET. DRILLING TEMPLATES AND GASKETS TO FACILITATE LOCATING AND MOUNTING THE HOUSING SHALL ALSO BE PROVIDED. THE HOUSING SHALL BE FINISHED IN BAKED RED ENAMEL. REMOTE ALARM LED INDICATORS AND REMOTE TEST STATIONS SHALL BE PROVIDED. b.ADDRESSABLE SMOKE DETECTORS 1)CEILING MOUNTED, ADDRESSABLE PHOTOELECTRIC 2)UL LISTED COMPATIBLE WITH THE FIRE ALARM CONTROL PANEL. 3)SHALL HAVE A FLASHING STATUS LED FOR VISUAL SUPERVISION. WHEN THE DETECTOR IS ACTUATED, THE FLASHING LED WILL LATCH ON SOLID. THE LED SHALL FLASH AT A 1/SEC RATE IF THE CHAMBER IS OUT OF CALIBRATION RANGE. THE DETECTOR MAY BE RESET BY ACTUATING THE CONTROL PANEL'S RESET SWITCH. c.SMOKE DETECTOR GUARDS 1)UNDERWRITERS LABORATORIES TESTED AND LISTED BY FOR USE WITH THE SMOKE DETECTORS THEY PROTECT. 2)GUARD DESIGN SHALL NOT AFFECT THE DETECTOR OPERATING SENSITIVITY AND SHALL NOT REDUCE THE LISTED DETECTOR SPACING. 3)CONSTRUCTED OF 16-GAUGE STEEL WITH A BAKED WHITE FINISH TO MATCH THE DETECTORS. 4)TAMPERPROOF MOUNTING HARDWARE SHALL BE PROVIDED. d.DETECTOR BASES: STANDARD DETECTOR MOUNTING BASES SUITABLE FOR MOUNTING ON EITHER NORTH AMERICAN 1-GANG, 3½ OR 4 INCH OCTAGON BOX AND 4 INCH SQUARE BOX, OR EUROPEAN BESA OR 1-GANG BOX. THE BASE SHALL, CONTAIN NO ELECTRONICS AND SUPPORT ALL SERIES DETECTOR TYPES. e.ADDRESSABLE MANUAL STATION 1)ADDRESSABLE DOUBLE ACTION, SINGLE STAGE 2)POLYCARBONATE CONSTRUCTION WITH INTERNAL TOGGLE SWITCH. 3)FINISHED IN RED WITH SILVER "PULL IN CASE OF FIRE" LETTERING 4)SUITABLE FOR MOUNTING ON NORTH AMERICAN 2 ½ (64MM) DEEP 1-GANG BOXES AND 1 ½ (38MM) DEEP 4 SQUARE BOXES WITH 1-GANG COVERS. 2.FIRE ALARM ACTUATING DEVICES a.NOTIFICATION APPLIANCES 1)LOW PROFILE HORN-STROBES a)AUDIBLE OUTPUT OF 92 DBA AT 10 FT. WHEN MEASURED IN REVERBERATION ROOM PER UL-464. b)INTEGRALLY MOUNTED FLASHING LIGHT UNIT WITH BLOCK LETTERS 'FIRE'. MULTI-CANDELA WITH FIELD-SELECTABLE SETTINGS OF 15CD, 30CD, 60CD, 75CD & 110CD, AND FLASH RATE BETWEEN ONE AND THREE HERTZ. ALL UNITS SHALL FLASH IN SYNCHRONIZATION WITH EACH OTHER. c)THE HORN SHALL HAVE A SELECTABLE STEADY OR SYNCHRONIZED TEMPORAL OUTPUT. d)IN AND OUT SCREW TERMINALS SHALL BE PROVIDED FOR WIRING. e)LOW PROFILE HORN/STROBES SHALL MOUNT IN A NORTH AMERICAN 1-GANG BOX. 2)LOW PROFILE STROBES a)PROVIDE LOW PROFILE WALL MOUNTED STROBES AT THE LOCATIONS SHOWN ON THE DRAWINGS. IN AND OUT SCREW TERMINALS SHALL BE PROVIDED FOR WIRING. STROBES SHALL PROVIDE SYNCHRONIZED FLASH OUTPUTS. STROBE OUTPUT SHALL BE DETERMINED AS REQUIRED BY ITS SPECIFIC LOCATION AND APPLICATION FROM A FAMILY OF 15CD, 30CD, 60CD, 75CD, OR 110CD DEVICES. LOW PROFILE STROBES SHALL MOUNT IN A NORTH AMERICAN 1-GANG BOX. 3.INITIATION & CONTROL MODULES a.RELAY MODULE 1)PROVIDE ADDRESSABLE CONTROL RELAY CIRCUIT MODULES AS REQUIRED. THE MODULE SHALL PROVIDE ONE (1) FORM C DRY RELAY CONTACTS RATED AT 24VDC @ 2 AMPS (PILOT DUTY) TO CONTROL EXTERNAL APPLIANCES OR EQUIPMENT. THE POSITION OF THE RELAY CONTACT SHALL BE CONFIRMED BY THE SYSTEM FIRMWARE. F.BATTERIES 1.SHALL BE 12 VOLT, GELL-CELL TYPE. 2.BATTERY SHALL HAVE SUFFICIENT CAPACITY TO POWER THE FIRE ALARM SYSTEM FOR NOT LESS THAN TWENTY-FOUR HOURS PLUS 5 MINUTES OF ALARM UPON A NORMAL AC POWER FAILURE. 3.THE BATTERIES ARE TO BE COMPLETELY MAINTENANCE FREE. NO LIQUIDS ARE REQUIRED. FLUID LEVEL CHECKS REFILLING, SPILLS AND LEAKAGE SHALL NOT BE REQUIRED. G.INSTALLATION 1.INSTALL FIRE ALARM AND DETECTION SYSTEMS AS INDICATED, IN ACCORDANCE WITH EQUIPMENT MANUFACTURER'S WRITTEN INSTRUCTIONS, AND COMPLYING WITH APPLICABLE PORTIONS OF NEC, NFPA AND NECA'S "STANDARD OF INSTALLATION". 2.INSTALL WIRING, RACEWAYS, CONDUCTORS, ELECTRICAL BOXES AND FITTINGS IN ACCORDANCE WITH CONDUIT, WIRE AND CABLE, AND BOXES AND PLATES SECTION OF THIS SPECIFICATION. 3.LABEL PULL AND JUNCTION BOXES "FIRE ALARM" WITH RED INDELIBLE INK. 4.LOOP WIRES THROUGH EACH DEVICE ON ZONE FOR PROPER SUPERVISION. TEE-TAPS NOT PERMITTED. 5.PROVIDE DUST PROTECTION FOR INSTALLED SMOKE DETECTORS UNTIL FINISH WORK IS COMPLETED AND BUILDING IS READY FOR OCCUPANCY. 6.PROTECT CONDUCTORS FROM CUTS, ABRASION AND OTHER DAMAGE DURING CONSTRUCTION. 7.MINIMUM CONDUCTOR SIZE SHALL BE 14 AWG UNLESS OTHERWISE SPECIFIED. 8.DO NOT INSTALL CEILING MOUNTED DETECTORS WITHIN 3 FEET OF AIR DISCHARGE GRILLS. COORDINATE WITH OTHER TRADES AS REQUIRED. 9.POST COPY OF WIRE IDENTIFICATION LIST INSIDE FIRE ALARM PANEL DOOR OR OTHER AREA ACCESSIBLE TO FIRE ALARM SERVICE PERSONNEL. 10.INSTALL CONDUCTORS AND MAKE CONNECTIONS TO ALL, WATER FLOW SWITCHES, VALVE TAMPER SWITCHES, LOW AIR PRESSURE SWITCHES, AND DOOR HOLDING DEVICES. 11.FIELD QUALITY CONTROL 1.TEST & INSPECTION a.ALL INTELLIGENT ADDRESSABLE DEVICES SHALL BE TESTED FOR CURRENT ADDRESS AND USER DEFINED MESSAGE. b.ALL WIRING SHALL BE TESTED FOR CONTINUITY, SHORTS, AND GROUNDS BEFORE THE SYSTEM IS ACTIVATED. c.ALL TEST EQUIPMENT, INSTRUMENTS, TOOLS AND LABOR REQUIRED TO CONDUCT THE TESTS SHALL BE MADE AVAILABLE BY THE INSTALLING CONTRACTOR. d.THE SYSTEM INCLUDING ALL ITS SEQUENCE OF OPERATIONS SHALL BE DEMONSTRATED TO THE OWNER, HIS REPRESENTATIVE, AND THE LOCAL FIRE INSPECTOR. IN THE EVENT THE SYSTEM DOES NOT OPERATE PROPERLY, THE TEST SHALL BE TERMINATED. CORRECTIONS SHALL BE MADE AND THE TESTING PROCEDURE SHALL BE REPEATED UNTIL IT IS ACCEPTABLE TO THE OWNER, HIS REPRESENTATIVES AND THE FIRE INSPECTOR. e.ALL FIRE ALARM TESTING SHALL BE IN ACCORDANCE WITH NATIONAL FIRE ALARM CODE, NFPA 72. I.MANUFACTURER'S FIELD SERVICE 1.INSTRUCT OWNER'S REPRESENTATIVE IN PROPER OPERATION AND MAINTENANCE PROCEDURES. 2.PROVIDE A MINIMUM OF 4 HOURS TRAINING. TELEPHONE/DATA SYSTEMS A.SUMMARY 1.INCLUDES BUT NOT LIMITED TO a.FURNISH AND INSTALL BUILDING TELEPHONE AND COMPUTER NETWORK RACEWAY AND CABLE SYSTEM AS DESCRIBED IN CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO, RACEWAY, OUTLETS, MODULAR JACKS, DEVICE PLATES, CABLES, PUNCH DOWN BLOCKS, BACKBOARDS, CABINETS, PATCH PANELS, GROUNDING AND OTHER MISCELLANEOUS ITEMS REQUIRED FOR A COMPLETE SYSTEM. b.FURNISH AND INSTALL MAIN SERVICE RACEWAY AS DESCRIBED IN CONTRACT DOCUMENTS AND TO COMPLY WITH TELEPHONE COMPANY REQUIREMENTS. B.COMPONENTS 1.TELEPHONE OUTLET BOX SHALL BE SINGLE DEVICE BOX. 2.BUILDING TELEPHONE AND COMPUTER NETWORK SYSTEM CABLE a.23 GAUGE, SOLID TINNED COPPER, FOUR TWISTED PAIRS. CATEGORY 6 b.USE PLENUM-RATED CABLE IN CEILINGS AND AREAS USED FOR PLENUM AIR RETURN 3.TELEPHONE/NETWORK JACKS a.WALL JACKS 1)CAT6 - HUBBELL HXJ6 OR ALTERNATE MANUFACTURER WITH EQUIVALENT PERFORMANCE STANDARD. b.PLATES 1)HUBBELL - IFP SERIES (PORT QUANTITY AS REQUIRED, COLOR BY ARCHITECT) 6.BACKBOARDS: INTERIOR GRADE PLYWOOD WITHOUT VOIDS, 3 4 INCH THICK; UL-LABELED FIRE RETARDANT. a.SIZE: 48 INCHES WIDE 96 INCHES HIGH. b.DO NOT PAINT OVER UL LABEL. c.PROVIDE ONE 48" MULTI-OUTLET POWER STRIP WITH INTEGRAL SURGE PROTECTION AND OUTLETS AT 6" O.C. (MINIMUM 7 OUTLETS) MOUNTED AT CENTER OF TERMINAL BOARD. 7.EQUIPMENT RACKS AND CABINETS: CEA-310 STANDARD 19 INCH WIDE COMPONENT RACKS. a.FLOOR MOUNTED RACKS: 16 GAGE STEEL CONSTRUCTION WITH CORROSION RESISTANT FINISH; VERTICAL AND HORIZONTAL CABLE MANAGEMENT CHANNELS, TOP AND BOTTOM CABLE TROUGHS, AND GROUNDING LUG. 8.CONNECTOR BLOCKS FOR CATEGORY 6 AND UP CABLING: TYPE 110 INSULATION DISPLACEMENT CONNECTORS; CAPACITY SUFFICIENT FOR CABLES TO BE TERMINATED PLUS 25 PERCENT SPARE. 9.PATCH PANELS FOR COPPER CABLING: SIZED TO FIT EIA STANDARD 19 INCH WIDE EQUIPMENT RACKS; 0.09 INCH THICK ALUMINUM; CABLING TERMINATED ON TYPE 110 INSULATION DISPLACEMENT CONNECTORS; PRINTED CIRCUIT BOARD INTERFACE. a.JACKS: NON-KEYED RJ-45, SUITABLE FOR AND COMPLYING WITH SAME STANDARDS CABLE TO BE TERMINATED; MAXIMUM 48 PORTS PER STANDARD WIDTH PANEL. b.CAPACITY: PROVIDE PORTS SUFFICIENT FOR CABLES TO BE TERMINATED PLUS 25 PERCENT SPARE PLUS MOUNTING SPACE FOR ALL ACTIVE COMPONENTS/EQUIPMENT REQUIRED TO CROSS-CONNECT TO ANY/ALL MODULAR JACK PORTS ON THE PATCH PANELS. c.LABELS: FACTORY INSTALLED LAMINATED PLASTIC NAMEPLATES ABOVE EACH PORT, NUMBERED CONSECUTIVELY; COMPLY WITH TIA/EIA-606 USING ENCODED IDENTIFIERS. d.PROVIDE INCOMING CABLE STRAIN RELIEF AND ROUTING GUIDES ON BACK OF PANEL. e.PATCH CORDS: PROVIDE ONE PATCH CORD FOR EACH PAIR OF PATCH PANEL PORTS. 10.CABLE MANAGEMENT a.EQUIP EACH RACK OR CABINET WITH VERTICAL CABLE SECTION. b.EQUIP EACH RACK OR CABINET WITH HORIZONTAL CABLE MANAGERS ABOVE AND BELOW EACH PATCH SECTION. 1)7 RINGS 2)6 PASS-THROUGH HOLES 3)HINGED FRONT COVER c.USE VELCRO CABLE WRAPS ON ALL CABLE - TIE WRAPS ARE NOT ACCEPTABLE. C.INSTALLATION 1.RUN 1" CONDUIT TO ACCESSIBLE CEILING SPACE FROM EACH OUTLET. INSTALL CABLE FROM TERMINAL BOARD TO EACH TELEPHONE/NETWORK OUTLET. 2.TERMINATE CABLES AT EACH OUTLET WITH SPECIFIED MODULAR JACK ASSEMBLY. 3.TERMINATE CABLES ON PUNCH DOWN BLOCKS OR PATCH PANELS AT TERMINAL BOARD. 4.PROVIDE TYPED LABELS AT ALL JACKS CORRESPONDING TO TYPED NUMBERING SYSTEM AT PATCH PANEL OR TERMINAL STRIP. D.QUALITY ASSURANCE 1.COMPLY WITH APPLICABLE PORTIONS OF NEC ANSI/EIA/TIA 568 AS TO TYPE PRODUCTS USED AND INSTALLATION OF COMPONENTS. PROVIDE PRODUCTS AND MATERIALS WHICH HAVE BEEN UL-LISTED AND LABELED. MO U N T A I N V I E W C L I N I C 40 4 N o r t h 2 n d E a s t Re x b u r g , I d a h o 8 3 4 4 0 THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THEINFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITHROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS ANDADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR INPART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW.COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR.511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT17 U.S.C. PAR. 301 (1991). COPYRIGHT©JOB#DATE PLOTTED:10/16/2019 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J19138.00 THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. PROJECT: THE RICHARDSON DESIGN PARTNERSHIP, L.L.C. TH E G R A P H I C M A T E R I A L A N D D E S I G N O N T H I S S H E E T A R E IN S T R U M E N T S O F S E R V I C E A N D R E M A I N A T A L L T I M E S T H E P R O P E R T Y OF T H E R I C H A R D S O N D E S I G N P A R T N E R S H I P , L . L . C . R E P R O D U C T I O N OR R E U S E O F T H E M A T E R I A L A N D D E S I G N C O N T A I N E D H E R E I N I S PR O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E R I C H A R D S O N DE S I G N P A R T N E R S H I P , L . L . C . © DR A W N B Y : PR O J E C T # : 1 9 - 1 1 5 . 0 1 CH E C K E D B Y : DATE: 510 South 600 East Salt Lake City, Utah 84102 P: 801.355.6868 F: 801.355.6880 DESCRIPTION 6/3/2019 D.D. SHEET # E6 . 3 CD RB EL E C T R I C A L SC H E D U L E S