HomeMy WebLinkAboutCOMCHECK MECHANICAL - 19-00604 - American First Credit Union - RemodelCOMcheck Software Version 4.1.1.0 Mechanical Compliance Certificate Project Title: 90.1 (2013) Standard Project Type:New Construction Location:Rexburg, Idaho Climate Zone:6b Construction Site: 510 N 2nd East, Suite 3 Rexburg, ID 83440 Owner/Agent: America First Credit Union 1344 West 4675 South Riverdale, UT 84405 Designer/Contractor: Prescott Muir Architect 171 West Pierpoint Ave Salt Lake City, UT 84101 801-521-9111 Project Information Energy Code: AFCU Rexburg TI Mechanical Systems List Quantity System Type & Description Split System Heat Pump Heating Mode: Capacity = 13 kBtu/h, Proposed Efficiency = 11.00 HSPF, Required Efficiency = 8.20 HSPF Cooling Mode: Capacity = 18 kBtu/h, Proposed Efficiency = 24.60 SEER, Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 2 | SAC-1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 2 Supply, Constant Volume, 600 CFM, 0.1 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System 1 (Single Zone): Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 91 ofPage JASON A. WENDEL, P.E.10/02/19 Inspection Checklist Requirements: 95.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.1.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2013) Standard Section # & Req.ID Plan Review Complies?Comments/Assumptions 4.2.2, 6.4.4.2.1, 6.7.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable Requirement will be met. 4.2.2, 8.4.1.1, 8.4.1.2, 8.7 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable 6.7.2.4 [PR5]1 Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects >=50,000 ft2. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 92 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions 6.4.3.7 [FO9]3 Freeze protection and snow/ice melting system sensors for future connection to controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 93 ofPage Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 6.4.1.4, 6.4.1.5 [ME1]2 HVAC equipment efficiency verified. Non-NAECA HVAC equipment labeled as meeting 90.1. Efficiency:_____Efficiency:_____Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. 6.4.3.4.1 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.3.4.2, 6.4.3.4.3 [ME4]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.4.5 [ME39]3 Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.3.4.4 [ME5]3 Ventilation fans >0.75 hp have automatic controls to shut off fan when not required. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.8 [ME6]1 Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable Exception: Systems with a design outdoor airflow less than 1200 cfm. 6.5.3.2.1 [ME40]2 DX cooling systems >= 75 kBtu/h (>= 65 kBtu/h effective 1/2016) and chilled-water and evaporative cooling fan motor hp >= ¼ designed to vary indoor fan airflow as a function of load and comply with operational requirements. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. See the Mechanical Systems list for values. 6.4.4.1.1 [ME7]3 Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.2 [ME8]2 HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. R-_____R-_____Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.3 [ME9]2 HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. _____ in._____ in.Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 94 ofPage Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 6.4.4.1.4 [ME41]3 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.4.2.1 [ME10]2 Ducts and plenums sealed based on static pressure and location. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.2.3 [ME19]3 Dehumidification controls provided to prevent reheating, recooling, mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.2.4.1 [ME68]3 Humidifiers with airstream mounted preheating jackets have preheat auto-shutoff value set to activate when humidification is not required. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.2.4.2 [ME69]3 Humidification system dispersion tube hot surfaces in the airstreams of ducts or air- handling units insulated >= R- 0.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.2.5 [ME70]3 Preheat coils controlled to stop heat output whenever mechanical cooling, including economizer operation, is active. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.3.5 [ME72]2 Motors for fans >= 1/12 hp and < 1 hp are electronically- commutated motors or have a minimum motor efficiency of 70%. These motors are also speed adjustable for either balancing or remote control. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.3.3 [ME42]3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. See the Mechanical Systems list for values. 6.5.4.2 [ME25]3 HVAC pumping systems >10 hp designed for variable fluid flow. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.6.1 [ME56]1 Exhaust air energy recovery on systems meeting Tables 6.5.6.1- 1, and 6.5.6.1-2. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.7.1.1 [ME32]2 Kitchen hoods >5,000 cfm have make up air >=50% of exhaust air volume. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 95 ofPage Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 6.5.7.1.2 [ME46]3 Conditioned supply air to space with a kitchen hood shall not exceed the greater of a) supply flow required to meet space heating or cooling, or b) hood exhaust flow minus the available air transfer from available spaces. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.7.1.5 [ME49]3 Approved field test used to evaluate design air flow rates and demonstrate proper capture and containment of kitchen exhaust systems. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.8.1 [ME34]2 Unenclosed spaces that are heated use only radiant heat. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.3.9 [ME63]2 Heating for vestibules and air curtains include automatic controls that shut off the heating system when outdoor air temperatures > 45F. Vestibule heating systems controlled by a thermostat in the vestibule with setpoint <= 60F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.10 [ME73]3 Doors separating conditioned space from the outdoors have controls that disable/reset heating and cooling system when open. Complies Does Not Not Observable Not Applicable Exception: Building entrances have automatic closing devices. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 96 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions 8.4.2 [EL10]2 At least 50% of all 125 volt 15- and 20-Amp receptacles are controlled by an automatic control device. Complies Does Not Not Observable Not Applicable 10.4.1 [EL9]2 Electric motors meet requirements where applicable. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 97 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions 6.4.3.1.2 [FI3]3 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.2 [FI20]3 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.3.1 [FI21]3 HVAC systems equipped with at least one automatic shutdown control. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.3.2 [FI22]3 Setback controls allow automatic restart and temporary operation as required for maintenance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.5 [FI5]3 Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.6 [FI6]3 When humidification and dehumidification are provided to a zone, simultaneous operation is prohibited. Humidity control prohibits the use of fossil fuel or electricity to produce RH > 30% in the warmest zone humidified and RH < 60% in the coldest zone dehumidified. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.2 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.3 [FI9]1 An air and/or hydronic system balancing report is provided for HVAC systems serving zones >5,000 ft2 of conditioned area. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.7.2.4 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable Requirement will be met. 10.4.3 [FI24]2 Elevators are designed with the proper lighting, ventilation power, and standby mode. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 98 ofPage Project Title: Data filename: AFCU Rexburg TI J:\Project Files\2019 Jobs\19093 - AFCU Rexburg TI\ENG\COMCheck\AFCU Rexburg Remodel.cck 10/03/19Report date: 99 ofPage