HomeMy WebLinkAboutINSPECTION SUMMARY - 13-0087 - 1148 Coyote Willow Way - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 09/26/2019 1:45 pm Permit Details Permit Number: 13-00287 1148 Coyote Willow Way - SFR 1148 Coyote Willow Way New Single Family Residence Permit Issued Date: 08/06/2013 Permit Inspection Statistics 22Total Inspections Completed: 14Total Inspections Passed: Inspection Pass Rate: 63.64% Permit Inspection History *Refer to Individual Inspection Report for more Details 08/09/2013PassTed DyeFooting Inspection 08/09/2013PassTed DyeFoundation Inspection rebar overlaps good after corrections 2 rebar in top 12" Inspector Comments: 09/03/2013PassDon AllenPlumbing Underground Inspection All good to cover the under groundInspector Comments: 09/27/2013Fail Framing/Structure Inspection - Missed nailing sheeting --Marked with green paint -Braced wall panel blocking missed -Diaganal nails missing in joist hanger (South girder in bedroom) -Stud needed under girder (East end girder) -Provide truss spec's -one smoke detector needed at bottom of stairs in basement -anchor bolts needed in bearing walls -studs missing in basement on north wall (Notch to wall) ***note: end of fan blade to smoke detector can not be less than 36" Inspector Comments: 09/27/2013PassBret StoddardElectrical Rough-in Approved for cover-windows must be installed immediately to protect the wiring from water damage, meter base conduit is not tight for the service to be approved. Inspector Comments: 10/03/2013FailDon AllenRadon-Ground Inspection 10/03/2013N/ADon AllenRadon-Ground Inspection 10/03/2013PassDon AllenHVAC Rough-in All good to cover the rough inInspector Comments: 10/03/2013PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 10/07/2013Fail Framing/Structure Inspection Sheeting good Smoke detector needed at bottom of stairs truss's A-4SA through A-4SD missing lateral bracing (circled on spec's Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 13-00287 1148 Coyote Willow Way - SFR 1148 Coyote Willow Way New Single Family Residence Permit Status of (Open) as of Report Date: 09/26/2019 1:45 pm Permit Inspection Summary ufer at electrical conduit locations.Inspector Comments: 10/10/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 10/18/2013FailQuinton OwensInsulation Inspection No soffit venting (baffles up against roof sheathing). Windows & doors not installed. Draft stop in floor/ceiling if over 1000 sf. R-13 in basement (guess). blown fiberglass in main floor exterior walls. Need retaining material at edge of vault to hold up attic insulation. Inspector Comments: 10/28/2013PassTed DyeFraming/Structure Inspection 10/28/2013PassTed DyeInsulation Inspection 10/28/2013PassTed DyeSheetrock/Drywall Inspection 12/23/2013FailBret StoddardElectrical Final Inspection Kitchen receptacle not grounded-GFCI, no access to jet tubs for both upstairs and downstairs, no A/C unit is installed(30A OCPD), range is changed to a 20A 120V single pole circuit, generator connection outside is blanked off, call for a re-inspect when ready. Inspector Comments: need trim on washer box in the basementInspector Comments: 12/24/2013PassDon AllenPlumbing Final Inspection GOOD FOR THE C/OInspector Comments: 12/26/2013FailTed DyeBuilding Final -lower handrail to be between 34"-38" (handrail to basement) -back step needed -smoke/C.O. detector needed out side bedrooms in basement. -Ladders needed in bedroom window wells. -Post address (house) number -Sidewalk to be in before 1st of June *********Basement finished************* Inspector Comments: 12/27/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O.-no A/C unit installed, no generator installed-junction box outside blanked with interlock switch in subpanel. Inspector Comments: 12/30/2013FailTed DyeBuilding Final Back deck to be completed by June 1st city side walks to be completed by June 1st Temp. certificate to be issued untill June 1st. Inspector Comments: 10/15/2015PassNatalie PowellSidewalk Inspection side walks to be completed by June 1stInspector Comments: 10/15/2015Pass Commercial Building Final Page 2 of 2