HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00340 - Windsor ManorPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 09/20/2019 10:09 am
Permit Details Permit Number: 13-00340
151 S 1st E - Windsor Manor Triplex - Apt. G1, G2, G3
151 S 1st E
New Multi-Family Residential/Dormitory
Permit Issued Date: 02/07/2014
Permit Inspection Statistics
33Total Inspections Completed:
22Total Inspections Passed:
Inspection Pass Rate: 66.67%
Permit Inspection History *Refer to Individual Inspection Report for more Details
02/06/2014FailQuinton OwensFraming/Structure Inspection
Double drywall on firewall behind tubs not in yet and at mech. chase. Attic
access? Roof vents missing. Smoke Det. required on each level. Entry from
garage included due to potential hazard from storage placed in front of wall
heater. South wall is firewall with other bldg- drywall to roof deck. RFI the
designer on rating at cricket overbuild.
Inspector Comments:
02/07/2014PassDon AllenPlumbing Underground Inspection
All good to cover the under groundInspector Comments:
02/12/2014FailQuinton OwensInsulation Inspection
West end TH: R-19 in ext. walls. Vent baffles installed. WINDOWS NOT
INSTALLED YET. Install insulation rulers in attic. Windows to be inspected.
Inspector Comments:
04/24/2014N/AJoel GrayPublic Works Final Inspection
10/29/2015PassJoel GraySidewalk Inspection
Building Inspection Type
11/08/2013PassQuinton OwensFoundation Inspection
CW10A v= 2 #5 @ 10" o.c.
h= 2 #4 @ 18" o.c.
w/ 2 #5 top & bottom
CW13: v=2 #5 @ 10" o.c.
h=2 #5 @ 16" o.c.
w/ 2 #5 top & bottom
Inspector Comments:
11/27/13 TD: Masonry Grout - approved.Inspector Comments:
1/16/14 TD: Rebar for slab - approved.Inspector Comments:
01/16/2014PassTed DyeFoundation Inspection
11/8/13: Fnd wall approved (requested for bldg 1 - incorrect) this was for
building 3. - approved.
CW10A - Vrt. 2 #5 @ 10" oc/Hrz 2 #4 at 18" oc w/ 2 #5 in top & bottom.
CW13 - Vrt 2 #5 @ 10" oc/Hrz 2 #5 @ 16" oc. w/2 #5 in top & bottom.
Inspector Comments:
02/04/2014FailTed DyeFraming/Structure Inspection
Insulate under bottom plate west apt. north wall.
Anchor bolts needed eat apt on north wall.
ok to sheetrock party walls.
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 13-00340
151 S 1st E - Windsor Manor Triplex - Apt. G1, G2, G3
151 S 1st E
New Multi-Family Residential/Dormitory
Permit Status of (Open) as of Report Date: 09/20/2019 10:09 am
Permit
Inspection
Summary
02/10/2014FailQuinton OwensInsulation Inspection
not all penetrations in attic Firewall are firestopped. Attic vents to be added.
Insulation pulled out of back wall in several locations. Missing attic access to be
22×30 min. rgh. Opening.
Inspector Comments:
02/11/2014PassQuinton OwensSheetrock/Drywall Inspection
west end townhouse only.Inspector Comments:
02/11/2014PassTed DyeInsulation Inspection
Middle apt fire caulking finished.
Framing - anchor bolt completed in middle apt.
Inspector Comments:
02/14/2014PassQuinton OwensSheetrock/Drywall Inspection
Screw spacing too far in both lower bathrooms next to tubs. Missed some screws
in stairwell, upper west bdrm in closet, and back right corner of kitchen. Finish
upper east bthrm. Firewalls complete.
Inspector Comments:
02/19/2014PassTed DyeFraming/Structure Inspection
passed items completed OK to insulatedInspector Comments:
03/14/2014PassTed DyeFooting Inspection
04/07/2014FailTed DyeBuilding Final
apt. 2 and 3 smoke detectors too close to fan blade
1,2 and 3 need ion sensing smoke/c.o. detector
2 hr wall needed at crickets
Inspector Comments:
04/11/2014FailTed DyeBuilding Final
04/24/2014PassTed DyeBuilding Final
building is complete. Exterior items, landscaping and sidewalks to be done.
Issue a temp C.O.
Inspector Comments:
Electrical Inspection Type
02/05/2014PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
02/06/2014PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
02/10/2014PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
02/26/2014PassBret StoddardCOM & MFR Electrical Service Inspection
02/26/2014PassBret StoddardCommercial Electrical Rough-in
04/02/2014FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
04/04/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved for a final and C.O. all three units.Inspector Comments:
Fire Inspection Type
04/30/2014PassDale PickeringFire Department Final Inspection
Page 2 of 3
(Continued)
Permit Details Permit Number: 13-00340
151 S 1st E - Windsor Manor Triplex - Apt. G1, G2, G3
151 S 1st E
New Multi-Family Residential/Dormitory
Permit Status of (Open) as of Report Date: 09/20/2019 10:09 am
Permit
Inspection
Summary
Mechanical Inspection Type
02/19/2014PassQuinton OwensHVAC Rough-in
all good to cover the rough inInspector Comments:
04/02/2014FailDon AllenHVAC Final Inspection
G3 exhaust fan upper west bath does not work
G2 exhaust fan upper east bath does not work
G1 G2 G3 needs return air for furnace
Inspector Comments:
04/07/2014PassDon AllenHVAC Final Inspection
All good for c/oInspector Comments:
Plumbing Inspection Type
02/07/2014FailDon AllenPlumbing Rough-in
all good to cover the rough inInspector Comments:
02/20/2014PassDon AllenPlumbing Rough-in
03/14/2014PassDon AllenPlumbing Water
delivered meterInspector Comments:
03/27/2014PassDon AllenPlumbing Final Inspection
Page 3 of 3