Permit Status of (Expired) as of Report Date: 09/20/2019 9:21 am
Permit Details Permit Number: 13-00372
570 Pheasant Run, Rigby - SFR
570 Pheasant Run
Single Family Residence Rigby
Permit Issued Date: 10/09/2013
Permit Inspection Statistics
19Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 78.95%
Permit Inspection History *Refer to Individual Inspection Report for more Details
09/25/2013PassTed DyeFooting Inspection
Ufer in garageInspector Comments:
10/01/2013PassTed DyeFoundation Inspection
Ufer bar w/ electrical conduitInspector Comments:
10/11/2013PassDon AllenPlumbing Underground Inspection
All good to cover the underground and sewer waterInspector Comments:
12/17/2013N/ATed DyeRadon-Ground Inspection
12/24/2013FailDon AllenPlumbing Rough-in
Need clean out on the shower
need clean out after 135 degree of change
Inspector Comments:
12/31/2013PassDon AllenPlumbing Rough-in
All good to cover the rough in they installed the clean outs the where neededInspector Comments:
01/06/2014PassBret StoddardElectrical Service Inspection
Approved to be energized for permanent power-inspected the electrical service
on the rough-in inspection.
Inspector Comments:
01/06/2014PassBret StoddardElectrical Rough-in
Approved for cover after the receptacle is installed near the stairway, inspected
the electrical service on the rough-in inspection. Basement is wired entirely. Need
to install a receptacle near the stairway.
Inspector Comments:
01/09/2014FailQuinton OwensFraming/Structure Inspection
Anchor bolts needed on bsmt bearing walls. Need Truss details. Smk det. needed
outside bsmt bdrms. Microlam from stairs to bedrm is not 14" as shown on
submitted floor layout plan. Dbl LVL ok at bay windows.
Inspector Comments:
01/13/2014PassDon AllenHVAC Rough-in
All good to cover the rough in
Gas presser held at 20 lb
Inspector Comments:
01/23/2014PassTed DyeFraming/Structure Inspection
Lateral bracing for truss's good
fire blocking was covered up and was not able to see
other items from past ticket were taken care of.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 13-00372
570 Pheasant Run, Rigby - SFR
570 Pheasant Run
Single Family Residence Rigby
Permit Status of (Expired) as of Report Date: 09/20/2019 9:21 am
Permit
Inspection
Summary
01/29/2014PassTed DyeInsulation Inspection
Fire blocking with insulation needs to be 16" below bottom of fur down
Insulate around front door
Lateral bracing missing in truss's
Inspector Comments:
01/29/2014PassTed DyeSheetrock/Drywall Inspection
Ok to tapeInspector Comments:
04/15/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved for a final and C.O.-no A/C unit installed(30A OCPD).Inspector Comments:
04/16/2014PassTed DyeSidewalk Inspection
04/16/2014PassTed DyeBuilding Final
The full basement is finish.Inspector Comments:
Mechanical Inspection Type
04/15/2014FailDon AllenHVAC Final Inspection
need to finish fire place in basement
need to fasten gas line in mech. room to water heater and furnace
Inspector Comments:
04/16/2014PassDon AllenHVAC Final Inspection
All good for c/oInspector Comments:
Plumbing Inspection Type
04/15/2014PassDon AllenPlumbing Final Inspection
All good for c/oInspector Comments:
Page 2 of 2