HomeMy WebLinkAboutENGINEER LETTER - 19-00540 - 240 W 3rd N - Solar Panel September 10, 2019 ONE SOLAR UTAH 2391 S 1650 W #C Woods Cross, UT 84087 SOLAR PANEL ROOF CERTIFICATION LETTER Jamison Residence 240 W 3rd North Rexburg, ID 83440 One Solar Utah prepared calculations for the roof trusses located at the residence referenced above. It was assumed that the lateral seismic and wind loads acting perpendicular to the trusses were distributed to the roof sheathing and into the walls and were not included in the calculations. The analysis was limited to each single roof truss and did not include any analysis of the wall, footing, etc. The loadings and analysis were in accordance with the following codes 1. 2015 International Residential Code 2. ASCE 7-10 Minimum Design Loads for Buildings and Other Structures 3. 2015 National Design Specification for Wood Construction 1. Dead Load a. Roof Members Self-weight b. Roof Load 10 psf c. Solar Panel 3 psf d. Ceiling Loads 5 psf 2. Live Load 20 psf 3. Ground Snow Load 50 psf 4. Wind a. 3 Second Wind Gust Velocity 115 mph b. Importance Factor 1.0 c. Exposure C 5. Seismic a. Site Classification D b. Design Spectral Reponses i. SDS 0.426 ii. SD1 0.226 c. Importance Factor 1.0 Based on the calculations of the existing trusses, the additional loading from the solar panels did not cause any of the roof trusses to become overstressed. Prepared By: ______________________________ Dereck Hodson, P.E. Professional Engineer State of Idaho License No. 18199 Expires 31 Dec 2019 10-Sep-19