HomeMy WebLinkAboutTRUSS SPECS - 19-00535 - 2125 Summerfield Ln - New SFRJob
19-099916T
Truss
A1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:42:53 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-R6QED6lGSgvGUWsAn_ZcK4pH7m2bv8_UCDOVZOyetem
Scale = 1:88.6
T3 T3
B1
W1 W2
W3
W4
W1W2
W3
W4
T2 T2
B1B2B2B2
T1 T1
ST19
ST17
ST18
ST15
ST16
ST13
ST14
ST11
ST12ST10
ST8
ST9
ST6
ST7
ST5ST4ST3
ST2
ST1
ST17
ST18
ST15
ST16
ST13
ST14
ST11
ST12 ST10
ST8
ST9
ST6
ST7
ST5
ST4
ST3
ST2
ST1
A B
C
D
E
F
G
H I
M L K J
BS
BT BU
BV
BW BX BY BZ CA CB
7x10
6x8
7x10
5x8
7x10
3x6
7x10 7x10
7x10
7x10
7x10
5x8
10-8-0
10-8-0
21-4-0
10-8-0
32-0-0
10-8-0
42-8-0
10-8-0
53-4-0
10-8-0
-1-0-0
1-0-0
8-10-11
8-10-11
17-9-5
8-10-11
26-8-0
8-10-11
35-6-11
8-10-11
44-5-5
8-10-11
53-4-0
8-10-11
54-4-0
1-0-0
0-
6
-
3
11
-
7
-
9
12
-
0
-
5
0-
6
-
3
5.00 12
Plate Offsets (X,Y)-- [B:0-2-1,Edge], [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [E:0-2-0,0-0-0], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [H:0-2-1,Edge], [J:0-1-8,0-0-2], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8]
, [L:0-5-0,0-4-8], [M:0-3-0,0-2-8], [M:0-5-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.47
0.60
0.96
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.44
-0.64
0.21
0.21
(loc)
K-L
K-L
H
K-L
l/defl
>999
>996
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 515 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST19: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-1-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-8-9 oc bracing.
WEBS 1 Row at midpt F-K, D-L
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2706/0-5-8 (min. 0-2-14), H=2698/0-3-8 (min. 0-2-14)
Max Horz B=232(LC 11)
Max UpliftB=-457(LC 12), H=-454(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-BS=-5709/1870, C-BS=-5575/1886, C-D=-5384/1891, D-BT=-4120/1558, E-BT=-3963/1576,
E-BU=-3969/1578, F-BU=-4126/1561, F-G=-5419/1906, G-BV=-5612/1902, H-BV=-5748/1886
BOT CHORD B-M=-1572/5120, M-BW=-1211/4161, BW-BX=-1211/4161, L-BX=-1211/4161, L-BY=-767/3097,
BY-BZ=-767/3097, K-BZ=-767/3097, K-CA=-1219/4171, CA-CB=-1219/4171, J-CB=-1219/4171,
H-J=-1584/5162
WEBS E-K=-467/1454, F-K=-1179/568, F-J=-355/1041, G-J=-651/374, E-L=-463/1444,
D-L=-1169/564, D-M=-342/1014, C-M=-631/364
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=53ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3) -1-1-1 to 4-2-15, Exterior(2) 4-2-15 to 26-8-0, Corner(3) 26-8-0 to 32-0-0,
Exterior(2) 32-0-0 to 54-5-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=457,
H=454.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-099916T
Truss
A2
Truss Type
Common
Qty
10
Ply
1
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:42:57 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-Ktfl3TpmWuPiz7Ax0pdYUw_z6NPXr3447qMji9yetei
Scale = 1:88.6
T3 T3
B1
W1 W2
W3
W4
W1W2
W3
W4
T2 T2
B1B2B2B2
T1 T1
A B
C
D
E
F
G
H I
M L K J
N
O P
Q
R S T U V W
7x10
6x8
7x10
5x8
7x10 7x10 7x10
7x10
7x10
7x10
5x8
10-8-0
10-8-0
21-4-0
10-8-0
32-0-0
10-8-0
42-8-0
10-8-0
53-4-0
10-8-0
-1-0-0
1-0-0
8-10-11
8-10-11
17-9-5
8-10-11
26-8-0
8-10-11
35-6-11
8-10-11
44-5-5
8-10-11
53-4-0
8-10-11
54-4-0
1-0-0
0-
6
-
3
11
-
7
-
9
12
-
0
-
5
0-
6
-
3
5.00 12
Plate Offsets (X,Y)-- [B:0-2-1,Edge], [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [H:0-2-1,Edge], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8], [L:0-5-0,0-4-8], [M:0-5-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.47
0.60
0.51
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.44
-0.64
0.21
0.20
(loc)
K-L
K-L
H
K-L
l/defl
>999
>996
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 333 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-1-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-4-6 oc bracing.
WEBS 1 Row at midpt F-K, D-L
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2706/0-5-8 (min. 0-2-14), H=2698/0-3-8 (min. 0-2-14)
Max Horz B=232(LC 11)
Max UpliftB=-457(LC 12), H=-454(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-N=-5709/998, C-N=-5575/1013, C-D=-5384/1027, D-O=-4120/862, E-O=-3963/879,
E-P=-3969/881, F-P=-4126/863, F-G=-5419/1035, G-Q=-5612/1023, H-Q=-5748/1007
BOT CHORD B-M=-823/5120, M-R=-610/4161, R-S=-610/4161, L-S=-610/4161, L-T=-364/3097,
T-U=-364/3097, K-U=-364/3097, K-V=-624/4171, V-W=-624/4171, J-W=-624/4171,
H-J=-828/5162
WEBS E-K=-246/1454, F-K=-1179/347, F-J=-179/1041, G-J=-651/240, E-L=-245/1444,
D-L=-1169/345, D-M=-172/1014, C-M=-631/234
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=53ft; eave=6ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-1-1 to 4-2-15, Interior(1) 4-2-15 to 26-8-0, Exterior(2) 26-8-0 to 32-0-0,
Interior(1) 32-0-0 to 54-5-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) All plates are 7x10 MT20 unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=457,
H=454.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-099916T
Truss
A3
Truss Type
Common
Qty
3
Ply
1
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:42:59 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-o3D7GppOHCXZbHk8ZX8n17X9jnm2aSBDLU5GEayeteh
Scale = 1:89.0
T3 T3
B1
W1
W2 W3
W4
W1W2
W3
W4
W5
T2
T1
B1B2B2B2
T2
T1
A B
C
D
E
F
G
HI
N M L K J
O
P Q
R
S T U V W X
7x10
6x8
7x10
5x8
7x10 7x10 7x10
7x10
7x10
7x10
4x5
5x6
10-8-0
10-8-0
21-4-0
10-8-0
32-0-0
10-8-0
42-8-0
10-8-0
46-11-8
4-3-8
53-4-0
6-4-8
-1-0-0
1-0-0
8-10-11
8-10-11
17-9-5
8-10-11
26-8-0
8-10-11
35-6-11
8-10-11
44-5-5
8-10-11
53-4-0
8-10-11
54-4-0
1-0-0
0-
6
-
3
11
-
7
-
9
12
-
0
-
5
0-
6
-
3
5.00 12
Plate Offsets (X,Y)-- [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [F:0-5-0,0-4-8], [G:0-4-12,0-4-8], [K:0-5-0,0-4-8], [L:0-5-0,0-4-8], [M:0-5-0,0-4-8], [N:0-5-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.42
0.51
0.71
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.30
-0.43
0.12
0.12
(loc)
M-N
M-N
J
M-N
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 338 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4,W5: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-5-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: H-J.
WEBS 1 Row at midpt E-L, F-L, F-K, D-M, G-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2341/0-5-8 (min. 0-2-8), J=3065/0-5-8 (min. 0-3-4)
Max Horz B=232(LC 11)
Max UpliftB=-397(LC 12), J=-511(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-O=-4798/803, C-O=-4665/819, C-D=-4472/832, D-P=-3185/662, E-P=-3053/680,
E-Q=-2624/571, F-Q=-2747/554, F-G=-1804/306, G-R=-651/1173, H-R=-665/1019
BOT CHORD B-N=-645/4322, N-S=-416/3394, S-T=-416/3394, M-T=-416/3394, M-U=-180/2301,
U-V=-180/2301, L-V=-180/2301, L-W=-250/2440, W-X=-250/2440, K-X=-250/2440,
J-K=-27/1014, H-J=-939/702
WEBS E-L=-53/573, F-L=-330/243, F-K=-1445/435, G-K=-215/1232, E-M=-246/1448, D-M=-1173/347,
D-N=-177/1026, C-N=-638/238, G-J=-3378/847
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=53ft; eave=6ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-1-1 to 4-2-15, Interior(1) 4-2-15 to 26-8-0, Exterior(2) 26-8-0 to 32-0-0,
Interior(1) 32-0-0 to 54-5-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) All plates are 7x10 MT20 unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=397,
J=511.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-099916T
Truss
A4
Truss Type
Common
Qty
6
Ply
1
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:43:01 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-CevGvrsHa7v8SkTjFfiUem9ed_m7ns?f2SKxrwyetee
Scale = 1:88.6
T3 T3
B1
W1 W2
W3
W4
W1W2
W3
W4
T2
T4
B1B2B2B2
T1
T2
A B
C
D
E
F
G
H
L K J I
M
N O
P
Q R S T U V
7x10
6x8
7x10
5x8
7x10 7x10 7x10
7x10
7x10
7x10
5x8
10-8-0
10-8-0
21-4-0
10-8-0
32-0-0
10-8-0
42-8-0
10-8-0
53-4-0
10-8-0
-1-0-0
1-0-0
8-10-11
8-10-11
17-9-5
8-10-11
26-8-0
8-10-11
35-6-11
8-10-11
44-5-5
8-10-11
53-4-0
8-10-11
0-
6
-
3
11
-
7
-
9
12
-
0
-
5
0-
6
-
3
5.00 12
Plate Offsets (X,Y)-- [B:0-1-5,Edge], [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [H:0-1-5,Edge], [I:0-5-0,0-4-8], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8], [L:0-5-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.51
0.62
0.51
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.45
-0.64
0.21
0.20
(loc)
J-K
J-K
H
J-K
l/defl
>999
>988
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 330 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-0-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 8-11-9 oc bracing.
WEBS 1 Row at midpt F-J, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2711/0-5-8 (min. 0-2-14), H=2598/Mechanical
Max Horz B=231(LC 11)
Max UpliftB=-459(LC 12), H=-405(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-M=-5722/1000, C-M=-5589/1016, C-D=-5397/1029, D-N=-4134/864, E-N=-3977/882,
E-O=-3989/893, F-O=-4145/876, F-G=-5479/1077, G-P=-5636/1066, H-P=-5811/1051
BOT CHORD B-L=-839/5132, L-Q=-641/4174, Q-R=-641/4174, K-R=-641/4174, K-S=-383/3109,
S-T=-383/3109, J-T=-383/3109, J-U=-639/4196, U-V=-639/4196, I-V=-639/4196,
H-I=-890/5230
WEBS E-J=-249/1467, F-J=-1192/350, F-I=-211/1080, G-I=-675/260, E-K=-245/1444,
D-K=-1169/345, D-L=-172/1014, C-L=-631/234
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=53ft; eave=6ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-1-1 to 4-2-15, Interior(1) 4-2-15 to 26-8-0, Exterior(2) 26-8-0 to 32-0-0,
Interior(1) 32-0-0 to 53-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) All plates are 7x10 MT20 unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=459,
H=405.
8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-099916T
Truss
A5
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:43:04 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-dDaOXsu9t2HiJCCHwoFBGOn9sCoq_6Z6kQYbSFyeteb
Scale = 1:88.9
T3 T3
B1
W1 W2
W3
W4
W1W2
W3
W4
T2
T4
B1B2B2B2
T1
T2
ST19
ST17
ST18
ST15
ST16
ST13
ST14
ST11
ST12ST10
ST8
ST9
ST6
ST7
ST5ST4ST3
ST2
ST1
ST17
ST18
ST15
ST16
ST13
ST14
ST11
ST12 ST10
ST8
ST9
ST6
ST7
ST5
ST4
ST3
ST2
ST1
A B
C
D
E
F
G
H
L K J I
BR
BS BT
BU
BV BW BX BY BZ CA
7x10
6x8
7x10
5x8
7x10
3x6
7x10 7x10
7x10
7x10
7x10
6x12
10-8-0
10-8-0
21-4-0
10-8-0
32-0-0
10-8-0
42-8-0
10-8-0
53-4-0
10-8-0
-1-0-0
1-0-0
8-10-11
8-10-11
17-9-5
8-10-11
26-8-0
8-10-11
35-6-11
8-10-11
44-5-5
8-10-11
53-4-0
8-10-11
0-
6
-
3
11
-
7
-
9
12
-
0
-
5
0-
6
-
3
5.00 12
Plate Offsets (X,Y)-- [B:0-2-1,Edge], [C:0-5-0,0-4-8], [D:0-5-0,0-4-8], [E:0-2-0,0-0-0], [F:0-5-0,0-4-8], [G:0-5-0,0-4-8], [I:0-1-8,0-0-2], [I:0-5-0,0-4-8], [J:0-5-0,0-4-8], [K:0-5-0,0-4-8],
[L:0-5-0,0-4-8], [L:0-3-0,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.51
0.62
0.97
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.45
-0.64
0.21
0.22
(loc)
J-K
J-K
H
J-K
l/defl
>999
>988
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 513 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST19: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-0-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-5-6 oc bracing.
WEBS 1 Row at midpt F-J, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2711/0-5-8 (min. 0-2-14), H=2598/Mechanical
Max Horz B=231(LC 11)
Max UpliftB=-459(LC 12), H=-405(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-BR=-5722/1874, C-BR=-5589/1890, C-D=-5397/1896, D-BS=-4134/1563, E-BS=-3977/1580,
E-BT=-3988/1599, F-BT=-4145/1582, F-G=-5479/1977, G-BU=-5636/1976, H-BU=-5811/1960
BOT CHORD B-L=-1592/5132, L-BV=-1246/4174, BV-BW=-1246/4174, K-BW=-1246/4174, K-BX=-797/3109,
BX-BY=-797/3109, J-BY=-797/3109, J-BZ=-1244/4196, BZ-CA=-1244/4196, I-CA=-1244/4196,
H-I=-1684/5230
WEBS E-J=-471/1467, F-J=-1192/573, F-I=-409/1080, G-I=-675/409, E-K=-463/1444,
D-K=-1169/564, D-L=-342/1014, C-L=-631/364
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=53ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3) -1-1-1 to 4-2-15, Exterior(2) 4-2-15 to 26-8-0, Corner(3) 26-8-0 to 32-0-0,
Exterior(2) 32-0-0 to 53-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=459,
H=405.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-099916T
Truss
B1
Truss Type
Common
Qty
1
Ply
1
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:43:06 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-Zci9yYwQOfXQYWMg1CHfLpsbD?caSFbOBk1hX8yeteZ
Scale = 1:27.8
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
HW1 HW1
A
B
C
D
E
F
G
H
I
J
K
P O N M L
4x5
3x4
3x4
3x4
3x4
13-4-0
13-4-0
-1-0-0
1-0-0
6-8-0
6-8-0
13-4-0
6-8-0
14-4-0
1-0-0
0-
8
-
3
4-
6
-
1
4
4-
9
-
1
1
0-
8
-
3
7.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.02
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
J
J
J
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 64 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
SLIDER Left 2x4 DF Stud/Std 1-6-8, Right 2x4 DF Stud/Std 1-6-8
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 13-4-0.
(lb) - Max Horz B=-100(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) B, J, O, P, M, L
Max Grav All reactions 250 lb or less at joint(s) N, O, P, M, L except B=256(LC 1), J=256(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3) -1-0-14 to 1-11-2, Exterior(2) 1-11-2 to 6-8-0, Corner(3) 6-8-0 to 9-8-0,
Exterior(2) 9-8-0 to 14-4-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, J, O, P, M, L.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-099916T
Truss
B2
Truss Type
Common Girder
Qty
1
Ply
2
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:43:08 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-V_qvNExgwHo8npV39dK7RExr7p9xw3yhf2Wob0yeteX
Scale = 1:29.5
T1 T1
B1
W1
W2
W1
W2
A
B
C
D
E
G FHIJK L M
7x10
9x12 MT18HS
7x10 12x12
1.5x4
12x12
1.5x4
Special Special Special Special
Special
Special
4-5-5
4-5-5
8-10-11
4-5-5
13-4-0
4-5-5
3-4-0
3-4-0
6-8-0
3-4-0
10-0-0
3-4-0
13-4-0
3-4-0
0-
8
-
3
4-
6
-
1
4
0-
8
-
3
7.00 12
Plate Offsets (X,Y)-- [E:0-2-1,Edge], [F:0-6-0,0-8-0], [G:0-6-0,0-8-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.49
0.61
0.44
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.12
-0.17
0.03
0.06
(loc)
F-G
F-G
E
F-G
l/defl
>999
>889
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT18HS
Weight: 171 lb FT = 20%
GRIP
220/195
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x10 DF 1950F 1.7E or 2x10 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W2: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-10-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)A=8708/0-5-8 (min. 0-4-10), E=8056/0-5-8 (min. 0-4-5)
Max Horz A=-89(LC 23)
Max UpliftA=-1389(LC 8), E=-1285(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-11220/1800, B-C=-11066/1814, C-D=-10999/1804, D-E=-11153/1790
BOT CHORD A-H=-1457/9266, H-I=-1457/9266, G-I=-1457/9266, G-J=-984/6544, J-K=-984/6544,
F-K=-984/6544, F-L=-1447/9207, L-M=-1447/9207, E-M=-1447/9207
WEBS C-F=-977/6059, D-F=-244/711, C-G=-996/6177, B-G=-244/709
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-3-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate
grip DOL=1.33
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=1389,
E=1285.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2584 lb down and 419 lb up at
1-4-12, 2584 lb down and 419 lb up at 3-4-12, 2584 lb down and 419 lb up at 5-4-12, 2584 lb down and 419 lb up at 7-4-12, and 2584
lb down and 419 lb up at 9-4-12, and 2584 lb down and 419 lb up at 11-4-12 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
Continued on page 2
Job
19-099916T
Truss
B2
Truss Type
Common Girder
Qty
1
Ply
2
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:43:09 2019 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-V_qvNExgwHo8npV39dK7RExr7p9xw3yhf2Wob?yeteX
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-C=-84, C-E=-84, A-E=-14
Concentrated Loads (lb)
Vert: H=-2584(B) I=-2584(B) J=-2584(B) K=-2584(B) L=-2584(B) M=-2584(B)
Job
19-099916T
Truss
V1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF1AB10 ATHENS
Job Reference (optional)
8.220 s Feb 10 2019 MiTek Industries, Inc. Tue Sep 10 22:43:10 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:rEZtIt9KfS6hZhiugAVpmhyewwi-SNxgowzwSu2s17fRG2MbWf0IPd_LO2u_6M?vgvyeteV
Scale = 1:40.3
T1 T1
B1
ST5
ST4
ST3
ST2
ST1
B1
ST4
ST3
ST2
ST1
A
B
C
D
E
F
G
H
I
J
K
T S R Q P O N M L
U
V W
X
3x4
4x5
3x4
5x6
21-10-11
21-10-11
10-11-6
10-11-6
21-10-11
10-11-6
0-
0
-
4
6-
4
-
1
0
0-
0
-
4
7.00 12
Plate Offsets (X,Y)-- [P:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.05
0.03
0.09
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
K
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 102 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 21-10-11.
(lb) - Max Horz A=-135(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) A, Q, R, S, T, O, N, M, L
Max Grav All reactions 250 lb or less at joint(s) A, K, P, Q, R, S, O, N, M except T=252(LC 1), L=252(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 10-11-6, Exterior(2) 10-11-6 to 13-11-6,
Interior(1) 13-11-6 to 21-4-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) A, Q, R, S, T, O, N, M,
L.
8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard