Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FIRE ALARM PRODUCT INFO - 19-00154 - 1450 N 2nd E - Walmart - Grocery pickup Addition
Intrusion Alarm Systems | D9412GV4 Series Control Panels D9412GV4 Series Control Panels www.boschsecurity.com u Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three u Conettix IP‑based communication options provide high‑speed, secure alarm transport and control through connection of wired and/or cellular network interfaces u Up to 32 programmable areas, each supporting both perimeter and interior points u 246 hardwired, addressable or wireless points with flexible configuration options to meet multiple installation requirements u Your choice of touch screen, vacuum florescent, ATM style or LED keypads GV4 panels are the premier commercial control panel line from Bosch. GV4 panels integrate intrusion, fire and access control providing one simple user interface for all systems. With the ability to adapt to large and small applications, the D9412GV4 provides up to 246 individually identified points that can be split into 32 areas. The control panel includes a communicator that sends events to selected public switched telephone network (PSTN), IP network, or cellular network destinations through four programmable route groups. With the D9412GV4 you can: • Monitor alarm points for intruder or fire alarms while operating keypads and other outputs • Program all system functions local or remote using Remote Programming Software (RPS) or by using basic programming through the keypad. • Add up to eight doors of access control using the optional D9210C Access Control Interface Module. Functions Programmable Outputs • 2 A alarm power at 12 VDC • 1.4 A auxiliary power at 12 VDC • Four alarm‑output patterns • Programmable bell test System Response • High-performance micro‑controller provides industry‑leading system response • High-speed device bus (NEW) • 31 custom point indexes, including fire supervisory • Selectable point response time • Cross point capability • Fire alarm verification • Fire inspector’s local test • Watch mode • Scheduled events (SKEDS) arm, disarm, bypass and unbypass points, control relays, control authority levels, and control door access User Interface • Supervision of up to 16 keypads (up to 32 unsupervised keypads can be used) • Remote Programming Software (RPS) Lite allows end users to perform control panel management tasks – Add/Delete/Change user passcodes and authorities, view and print the panel history event log • Custom keypad text is fully programmable, including remote programming • Full function command menu including Custom Functions • Authority by area and 16‑character name for each user • 14 custom authority levels control user’s authority to change, add, or delete passcodes or access control credentials; to disarm or bypass points; and to start system tests Area Configurations Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master or associate). Any area can be configured for perimeter and interior arming, not requiring a separate area for this function. Custom Functions For added convenience, Custom Functions can be programmed to eliminate keystrokes for users allowing the installer to program an easy command for a complicate function. For example, a custom function can be written to bypass a group of points and arm the system, allowing the user to perform this function with one easy command. This can be used to control a particular room, or even a single door allowing customized access. In additions, Custom Functions can be activated with a token or card, or automatically as a scheduled event (SKED) providing further flexibility and ease of use. Door‑Activated Custom Function A custom function activates when user credentials are presented to a D9210C Access Control Interface Module door controller's reader. The custom function behaves as though the user performed a function at the keypad associated with the door controller. Passcode Security For high security applications, GV4 can be configured for several different passcode options. • Dual Authentication – requires a user to enter their passcode and also use a token or card (NEW). • Two-Man Rule - Requires two people with two unique passcodes to be present at the time of opening. • Early Ambush - Allows users to verify that the facility is safe by requiring two passcode entries at the same keypad, sending a duress event if the user does not enter the passcode a second time after inspecting the premises. Easy Exit Control The D9412GV4 Control Panel changes from one armed state to another armed state without disarming. For example, if you change the state from Perimeter Arm to Master Arm, the control panel complies and reports the change. Easy Exit Control reduces the number of keystrokes, simplifying system operation. Programmable Passcode‑controlled Menu List The system prompts users to enter a passcode prior to viewing the keypad menu. The keypad display shows the user the menu options allowed according to the user’s authority level. Passcode-controlled menus provide users only with the options and information pertinent to them, simplifying system operation. Flexible Control The system provides the flexibility to select added convenience or high security. For example, you can restrict passcode arming and disarming to a keypad's immediate local area, even if the user has access to other areas. This is particularly useful for high security areas, where a user may have access to the area, but would prefer to only disarm the area individually rather than with the rest of the system. Another option is to program the system to disarm all areas the user can access from any keypad. Invisible Walk Test A menu item allows the user to test invisible 24‑hour points within the scope of the keypad without sending a report to the central station. System Users The system supports up to 1000 users, each can have a passcode, an access token and a wireless keyfob (NEW). User passcodes contain three to six digits. Passcodes can be assigned to one of 14 customized authority levels in each area, and can be restricted to operate only during certain times. Communication Formats The D9412GV4 Control Panel prioritizes and sends reports in Contact ID or Modem IIIa2 communications formats to four route groups. Each group has a programmable primary and backup destination. The D9412GV4 provides flexible communications for most central stations with reporting capabilities such as: • Individual point numbers • Opening or closing reports by user and area number • Remote programming attempts • Diagnostic reports IP Communication The D9412GV4 uses the B420 Ethernet Communication Module (NEW), DX4020 and/or the ITS‑DX4020‑G Cellular Communicator to communicate with the Conettix D6600 and D6100i Communications Receiver/Gateways. Using Conettix IP communication offers a secure path that includes anti-replay/anti- substitution features and provides enhanced security with encryption. The B420, DX4020 and ITS‑DX4020‑G can all be used for remote programming. GV4 is the first Security Control panel to support DNS (Domain Name System) for both remote programming and central station communication. DNS provides ease of use, eliminating the need to use static IP addresses as your reporting destination and accommodates a simple solution for central station disaster recovery. 2 | D9412GV4 Series Control Panels IP Setup is available via the installer keypad menus and the remote programming software, eliminating the need to use complicated internet programming tools such as ARP and Telnet (NEW). Communication Paths D9412GV4 Control Panels accommodate up to four separate destinations for primary, alternate, and backup receivers for automatic test reports. When resetting alarms or arming or disarming a system, the user is identified by name and number. Firmware Updates (NEW) Remote firmware updates using the RPS Firmware Update wizard through the IP connection (B420 Ethernet Communication Module) as well as an on-site flash update key, provides for easy feature enhancements without replacing ROM chips. A wide variety of input options Each point: • Accommodates normally‑open (NO) and normally‑closed (NC) devices with end‑of‑line (EOL) resistor supervision. • Is programmable for fire, fire supervisory, or intrusion application. • Can be hard-wired, addressable, or wireless. Security and Fire Detection The D9412GV4 Control Panel provides eight on‑board points, and up to 238 additional off‑board points. You can program individual points to monitor all types of burglar alarms, fire alarms, and supervision devices. Access Control The D9412GV4 provides custom door strike, point shunt and auto disarming response by area. There are 14 panel‑wide access levels with both manual and scheduled control. Store, view, or print access events such as: • Access granted • No entry • Request to enter • Request to exit Wireless Interface (NEW) The B820 SDI2 Inovonics Interface Module connects an Inovonics EN4200 Serial Receiver to the control panel SDI2 bus, allowing this UL Listed (NEW) wireless system to be programmed locally via the panel keypad, as well as remotely through RPS. Event Log The event log stores up to 1,000 local and transmitted events. The event log includes time, date, event, area, point, user number, and transmission status (NEW). View the event log from a keypad or use RPS to remotely retrieve event information. RPS operators can retrieve events periodically using one call, rather than receiving several calls each day. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver. Scheduled Events (SKEDS) The internal clock and calendar start individually scheduled events (SKEDS). SKEDS perform functions such as arm or disarm, relay control, or point bypassing. The D9412GV4 Control Panel offers: • 40 scheduled events with up to 25 different functions • Eight opening windows and eight closing windows • Eight user windows • Day-of-week, date-of-month, or holiday only schedules • Four holiday schedules of 366 days each (leap year) Fire Test When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. The keypad and annunciator show all testing data. An automatic sensor reset feature saves time; you do not need to reset the sensors manually. At the end of test, the keypad shows the number of untested points. Programming, Diagnostics and Controls Installers can program locally or remotely through RPS as well as basic keypad programming. A programmable system passcode prevents unauthorized remote programming. Two Data Buses (NEW) GV4 provides 2 data buses which support a wide array of components. The SDI bus supports keypads access and communications modules and also allows connection of existing components in a retrofit application. The new SDI2 bus supports input and output devices as well as a new wireless interface module, and an Ethernet communicator. SDI2 allows these devices to be mounted up to 1000 ft (305 m) from the control panel, providing installation convenience and flexibility. Commercial Fire Alarm Support Suitable for Commercial Fire (UL 864, 9th Edition) applications. Certifications and Approvals USA: UL 365 Police Station Connected Burglar Alarm Units and Systems UL 609 Local Burglar Alarm Units and Systems UL 636 (NEW)Holdup Alarm Units and Systems UL 864 Control Units and Accessories for Fire Alarm Systems (Commercial Fire) UL 985 Household Fire Warning System Units UL 1023 Household Burglar Alarm System Units UL 1076 Proprietary Burglar Alarm Units and Systems UL 1610 Central Station Burglar Alarm Units ANSI/SIA CP-01:2010 False Alarm Reduction CSFM California Office of The State Fire Marshall 3 | D9412GV4 Series Control Panels FCC Part 15 Class B Region Certification USA UL AMCX.S1871, Central Station AlarmUnits; AMTB. S1871, Control Panels,SIA False Alarm Reduction;AOTX.S1871, Local Alarm Units;APAW.S1871, Police Station AlarmUnits; APOU.S1871, Proprietary AlarmUnits; NBSX.S1871, Household BurglarAlarm System Units; UOJZ.S1871, Con-trol Units, System; UTOU.S1871, Con-trol Units and Accessories, HouseholdSystem Type FDNY-CoA #6102 UL 864 9th Edition [D9412GV4,D7412GV4] CSFM 7167-1615:0243 Catagory 7167 - Con-trol Unit (Household). [D9412GV4,D7412GV4, D7212GV4] Installation/Configuration Notes Compatible Products Keypads D1265 Touch Screen Keypad D1255 Series Keypads (D1255, D1255W, D1255B, D1255RB, D1265) D1260 Series Keypads (D1260, D1260W, D1260R, D1260BLK, D1260B) D1256RB Fire Keypad D1257RB Remote Fire Alarm Annunciator D720 Series Keypads (D720, D720W, D720R, D720B) D279A Independent Zone Control Detectors D278S Four‑wire Addressable Detector Base, 12 VDC D285/TH Photoelectric Smoke Detector Heads D298S Addressable Detector Base, 24 VDC D7050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads F220‑B6PM/S 12/24 VDC Addressable Detector Bases with POPITs FCC-380 Carbon Monoxide Detector MX775i Addressable PIR Detector MX794i Long Range Multiplex PIR Detector MX934i Addressable PIR Detector MX938i Addressable PIR Detector ZX776Z PIR Detector ZX794Z Long Range PIR Detector ZX835 TriTech Microwave/PIR Detector ZX935Z PIR Detector ZX938Z PIR Detector ZX970 PIR/Microwave Detector Bosch conventional detectors, including Professional Series, Blue Line Gen2, Blue Line, Classic Line, Commercial Line, and Ceiling Mount motion detectors, as well as glass break, seismic, request-to-exit, photoelectric, heat, and smoke detectors. Enclosures D8103 Universal Enclosure D8108A Attack‑resistant Enclosure D8109 Fire Enclosure Magnetic Contacts Bosch magnetic contacts include recessed, terminal connection, miniature, overhead door, and surface mount. Modules Conettix B420 Ethernet Communication Module (NEW) Conettix ITS‑DX4020-G Cellular Integrated Communicator Conettix DX4020 Network Interface Module Conettix DX4010V2 USB/Serial Interface Module Conettix C900V2 Dialer Capture Module D113 Battery Lead Supervision Module D125B Dual Class B Initiating Module D127 Reversing Relay Module D129 Class A Initiating Module D130 Auxiliary Relay Module D185 Reverse Polarity Signaling Module D192G Notification Appliance Circuit Module D928 Phone Line Switcher D5060 MUX Programmer B208 Octo-input Module (NEW) B308 Octo-output Module (NEW) B820 SDI2 Inovonics Interface Module (NEW) D8125 POPEX Point Expander D8128D OctoPOPIT Eight‑point Expander D8125MUX Point Expander D8125INV Wireless Interface Module D8129 Octo‑relay Module D8130 Door Release Module D9127 Series POPIT Modules D9131A Parallel Printer Interface Module D9210C Access Control Interface Module DS7432 Eight‑input Remote Module 4 | D9412GV4 Series Control Panels DS7457i Series Single‑zone Multiplex Input Modules DS7460i Two‑input Module DS7461i Single‑input Multiplex Module DS7465i Input and Output Module ICP-SDI-9114 SDI Splitter Programming RPS or RPS‑LITE Remote Programming Software Readers ARD‑R10 iCLASS Mullion Reader ARD‑R40 iCLASS Switchplate Reader ARD‑RK40‑09 iCLASS PIN Reader ARD‑VSMART iCLASS Reader D8223 Prox Pro Reader D8224 Mullion Reader D8224‑SP Switch Plate Reader D8225 Mini Mullion Reader D8301W Low‑profile Proximity Readers Wireless B820 SDI2 Inovonics Interface Module SDI2 Inovonics Interface and Receiver Kit. Includes B820 and EN4200 (ENKIT-SDI2) EN1210 Universal Transmitter (Single-input) EN1210EOL Universal Transmitter with EOL Resistor EN1210W Door-Window Transmitter with Reed Switch EN1215EOL Universal Transmitter with Wall Tamper, Reed Switch, and EOL Resistor EN1223D Water‑resistant Pendant Transmitter (Double‑button) EN1223S Water‑resistant Pendant Transmitter (Single‑button) EN1224-ON Multiple-Condition Pendant Transmitter EN1233D Necklace Pendant Transmitter (Double-button) EN1233S Necklace Pendant Transmitter (Single-button) EN1235D Beltclip Pendant Transmitter (Double-button) EN1235DF Fixed-location Transmitter (Double-button) EN1235S Beltclip Pendant Transmitter (Single-button) EN1235SF Fixed-location Transmitter (Single-button) EN1247 Glass-break Detector Transmitter EN1249 Bill Trap Transmitter EN1242 Smoke Detector Transmitter EN1260 Wall Mount Motion Detector EN1261HT High Traffic Motion Detector EN1262 Motion Detector with Pet Immunity EM1265 360° Ceiling Mount Motion Detector EN4200 Serial Receiver EN5040-T High Power Repeater with Transformer Parts Included The D9412GV4 includes the following parts: Quant.Component 1 D9412GV4 Board 1 Mounting Skirt 1 Faceplate with D9412GV4 Label 1 Literature pack • Installation Instructions • Owners Manual • Release Notes 1 Literature CD containing all product literature The available kits come with the parts indicated in the following table: Kits Components ‑A ‑B ‑C D9412GV4 Board 1 1 1 D122 Dual Battery Harness 1 D161 Dual Modular Phone Cord 2 D928 Dual Phone Line Switcher 1 D1640 Transformer 1 1 D8103 Enclosure 1 D8108A Attack‑resistant Enclosure 1 D8109 Fire Enclosure 1 D101 Lock and Key Set 1 1 D101F Lock and Key Set 1 Technical Specifications Communications Telephone Connection: • One telephone line • D928 Dual Phone Line Module required for two telephone lines Environmental Considerations Relative Humidity:5% to 93% at +30°C (+86°F), non‑condensing Temperature (Operating):0°C to +50°C (+32°F to +122°F) Number of… Areas:32 Card Readers (Doors):8 5 | D9412GV4 Series Control Panels Credentials (Tokens):999 Custom Functions:16 Events:Up to 1000 Passcode Users:999, plus 1 service passcode Parallel Printers:3 Points:246 (8 on‑board, up to 238 off‑board) Programmable Relay Outputs:131 RF Points:238 SKEDs:64 Power Requirements Current Draw (Maximum):300 mA Output (Alarm):2 A at 12 VDC Output (Auxiliary, Continuous Power, and Switched Auxiliary combined): 1.4 A at 12 VDC nominal Voltage (Operating):12 VDC nominal Voltage (AC):16.5 VAC 40 VA plug‑in transformer (D1640) Trademarks Inovonics is a trademark of Inovonics Wireless Corporation. Ordering Information D9412GV4 246-point Control Communicator Order number D9412GV4 D9412GV4-A Attack-resistant Package Contains one PCB, one transformer, and one attack- resistant enclosure. Order number D9412GV4-A D9412GV4-B Fire/Burglar Package Contains one PCB, one dual battery harness, two telephone cords, one telephone line switcher, one transformer, and one fire enclosure. Order number D9412GV4-B D9412GV4-C Standard Burglar Package Contains one PCB, one lock and key set, one transformer, and one universal enclosure. Order number D9412GV4-C Accessories SDI2 Inovonics Interface and Receiver Kit Kit containing B820 and EN4200 for use on SDI2 bus panels. Order number ENKIT-SDI2 D928 Dual Phone Line Switcher Allows the control panel to operate over and supervise two separate phone lines. Only one D162 phone cord is supplied. Two additional D161 or D162 phone cords are required. Order number D928 D122 Dual Battery Harness Harness with circuit breaker. Connects two batteries to a compatible control panel. Order number D122 D122L Dual Battery Harness with Long Leads Color-coded harness with circuit breaker and leads measuring 89 cm (35 in.). Connects 12 V batteries to compatible control panels. Order number D122L D126 Standby Battery (12 V, 7 Ah) Sealed lead‑acid standby and auxiliary rechargeable power supply. Order number D126 D1218 Battery (12 V, 18 Ah) A 12 V sealed lead‑acid battery for standby and auxiliary power with two bolt‑fastened terminals. Includes hardware for attaching battery leads or spade connectors Order number D1218 D1224 Battery (12 V, 26‑28 Ah) A 12 V sealed lead‑acid battery for standby and auxiliary power with two bolt‑fastened terminals. Includes hardware for attaching battery leads or spade connectors. Order number D1224 D1238 Battery (12 V, 38 Ah) A 12 V sealed lead-acid battery for standby and auxiliary power with two bolt‑fastened terminals. Includes hardware for attaching battery leads or spade connectors. Order number D1238 D137 Mounting Bracket Used to mount accessory modules in D8103, D8108A, and D8109 enclosures. Order number D137 D138 Mounting Bracket, Right Angle Used to mount accessory modules in D8103, D8108A, and D8109 enclosures. Order number D138 D1640 Transformer System transformer rated at 16.5 VAC, 40 VA. Order number D1640 D8004 Transformer Enclosure For applications such as fire alarm that might require a transformer enclosure. Order number D8004 6 | D9412GV4 Series Control Panels D9002‑5 Mounting Skirt Mounts inside D8103, D8108A, and D8109 enclosures. Can accept up to six standard 7.62 cm x 12.7 cm (3 in. x 5 in.) cards. Order number D9002-5 D101 Lock and Key Set Standard lock set with one key supplied. Uses the D102 (#1358) replacement key. Order number D101 D110 Tamper Switch Screw‑on tamper switch that fits all enclosures. Shipped in packages of two. Order number D110 ICP‑EZTS Dual Tamper Switch Combination tamper switch with a wire loop for additional tamper outputs. Order number ICP-EZTS D8108A Attack Resistant Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. Includes lock and key set. Requires the D2402 Mounting Plate. Order number D8108A D8103 Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). Order number D8103 D8109 Fire Enclosure Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock and key set. Order number D8109 Software Options RPS Kit (USB) Account management and control panel-programming software with USB security key (dongle). Order number D5500C-USB 7 | D9412GV4 Series Control Panels Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 al.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems 2012 | Data subject to change without notice 2495537803 | en, V7, 10. Jul 2012 Intrusion Alarm Systems | D9127 Series POPIT Modules D9127 Series POPIT Modules www.boschsecurity.com u Provides point identification of initiating devices u Supervises wiring to devices for circuit integrity u Expands the number of points in the system u Compact size u Terminal connections for reliability The D9127 Series POPIT Modules includes the D9127T (with magnetic tamper switch) and the D9127U (without tamper). They are used with a D8125 Addressable Expansion Module when there is a need to expand a compatible control panel beyond its standard number of on-board initiating zones or points. Future system expansion is very economical as D9127 Series POPITs can be added anywhere along the two-wire data expansion loop from the D8125 module. Both modules include proven technology that combines zone and point supervision with individual device addressing on one pair of wires. Screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Install a 33 kΩ end-of-line resistor at the farthest point on the loop for proper supervision. The units are small and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations. Certifications and approvals Region Certification USA UL UL UL 365 - Police Station Connected Bur-glar Alarm Units UL UL 464 - Standard for Audible Signal Ap-pliances UL UL 609 - Standard for Local BurglarAlarm Units and Systems UL UL 864 - Standard for Control Units andAccessories for Fire Alarm Systems UL UL 985 - Household Fire Warning Sys-tem Units UL UL 1023 - Household Burglar Alarm Sys-tem Units UL UL 1076 - Proprietary Burglar AlarmUnits and Systems UL UL 1610 - Central Station Burglar AlarmUnits UL UL 1635 - Standard for Digital AlarmCommunicator System Units FM Region Certification CSFM see our website FDNY-CoA 6059 [D9412GV3 & D7412GV3] FDNY-CoA 6174 FDNY-CoA 6196 Australia CTICK C-Tick Canada ULC AMCX7.S1871 - Central Station AlarmUnits Certified for Canada ULC AOTX7.S1871 Local Alarm Units Certi-fied for Canada ULC APAW7.S1871 Police-station-connec-ted Alarm Units Certified for Canada ULC APOU7.S1871 Proprietary Alarm UnitsCertified for Canada ULC NBSX7.S1871 Household Burglar AlarmSystem Units Certified for Canada Installation/configuration notes Compatibility Information Control Panels All G Series control panels, D9412, D7412, D7212, D7212B1, D9112, D9112B1, D8112G1, D8112G2, and D9124 Module D8125 The D8125 Multiplex Zone Expander is required. The D9127 modules are wired in parallel on the D8125 data loop. Number of POPIT Modules per Control Panel D7212G, D7212GV2, D7212GV3 32 D9127 POPITs D7212B1 40 D9127 POPITs D7212, D7412, D7412G, D7412GV2, D7412GV3 67 D9127 POPITs D9124 119 D9127 POPITs D9112B1 126 D9127 POPITs D9112, D9412, D9412G, D9412GV2, D9412GV3 238 D9127 POPITs Wiring Considerations Wire Size Maximum Length of all Data Expansion Loops Combined 0.8 mm (22 AWG)549 m (1800 ft) 1.0 mm (20 AWG)881 m (2890 ft) 1.2 mm (18 AWG)1402 m (4600 ft) 1.5 mm (16 AWG)2231 m (7320 ft) 1.8 mm (14 AWG)3551 m (11650 ft) D8125 to POPIT Loops Use one two-wire data expansion loop, or distribute the POPITs on up to three loops. The maximum lengths shown in the following table are for all data expansion loops combined connected to the same D8125 module. Setting DIP switches on the POPIT modules assigns them to point numbers. The switch setting on each POPIT assigns it a point number, regardless of its physical location. POPIT to Sensor Loops The number of detection devices each sensor loop can supervise is limited only by the resistance on the loop. Resistance on each sensor loop must be less than 100 Ω not including the end-of-line (EOL) resistor. Certain UL and National Fire Protection Association (NFPA) applications can limit the number of detection devices. Consult the appropriate UL or NFPA standards. Terminate each POPIT sensor loop with the 33 kΩ EOL resistor included with each POPIT. Use a twisted-pair wire (six twists per foot) in all POPIT installations for both the data expansion loop wiring and the POPIT sensor loops. Run wires away from AC sources to prevent AC induction. Parts included Quantit y Component 1 POPIT module 1 33 kΩ EOL resistor 1 Magnet (D9127T only) 1 Hardware pack 1 Literature pack Technical specifications Environmental Considerations Relative humidity Up to 93% non-condensing Temperature (operating) 0°C to +50°C (+32°F to +122°F) Properties Color Off white Dimensions 8.1 cm x 3.8 cm x 2.4 cm (3.2 in. x 1.5 in. x 0.9 in.) Material UL Listed fire-resistant 2 | D9127 Series POPIT Modules Power Requirements Current draw 0.8 mA maximum Resistance Maximum increase in resistance on the POPIT loop is 1000 Ω. Maximum resistance between the D8125 module and each POPIT is 90 Ω. Voltage (operating)12 VDC nominal Sensor Loop Resistance Maximum resistance on the sensor loop is 100 Ω. Response time 1 sec approximately Ordering information D9127T POPIT Module Includes a magnetic tamper switch. Order number D9127T D9127U POPIT Module No tamper switch. Order number D9127U 3 | D9127 Series POPIT Modules Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 203 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2016 | Data subject to change without notice 2538178443 | en, V10, 22. Jan 2016 Intrusion Alarm Systems | D1256RB Fire Keypad D1256RB Fire Keypad www.boschsecurity.com u Compatible with Bosch GV3 control panels and GV2 control panels (firmware version 7.04 and higher) u Provides system control with easy to use function keys u Built-in multi-tone sounder u Easy to read vacuum-fluorescent display (VFD) shows complete system status in English u Programmable custom text for each point The D1256RB Fire Keypad is a full-function system controller and annunciator. This SDI bus compatible device works with the Bosch Security Systems, Inc. GV3 control panels and GV2 control panels (firmware version 7.04 and higher). Four one-touch function keys provide user-friendly control over the system. The function keys allow the user to silence the audible alarm output, silence the trouble sounder, reset the annunciator display, and reset the system detectors. Four additional navigational keys allow access to other programmed system functions. The D1256RB can be mounted in secure areas. Functions Display The display uses words, numbers, and symbols to show the status of the fire system. When several events occur, each event is shown in order of priority followed by the time of occurrence. In conjunction with the 16‑character vacuum-fluorescent display (VFD), four LEDs provide the following system status indications: • Fire • Silenced • Supervisory • Trouble Certifications and approvals Region Certification USA UL UOXX: Control Unit Accessories, System(ANSI/UL 864) FM CSFM see our website FDNY-CoA 6174 FDNY-CoA 6059 [D9412GV3 & D7412GV3] FDNY-CoA 6196 Installation/configuration notes Compatible Control Panels • B9512G/B9512G-E • B8512G/B8512G-E • D9412GV4/D7412GV4/D7212GV4 1 • D9412GV3/D7412GV3/D7212GV3 1 • D9412GV2/D7412GV2/D7212GV2 1 1The D7212GV4, D7212GV3, and D7212GV2 are not listed for commercial fire applications. Mounting Considerations The keypad is a low profile, surface-mounted unit molded in durable red plastic with three mounting holes in the base that allow secure, correct positioning during installation. Protect the surface-mounted keypad by mounting it to a D56 or D56R Conduit Back Box. For desktop applications, the keypad can be mounted to a D55 Desk Stand. Notice Do not install the keypad in direct sunlight. This damages the module components and makes the display less visible. Do not mount in wet or moist locations. Wiring Considerations The keypad connects to the control panel for data and power through a standard four-wire flying lead cable. For field wiring use 0.8 mm (22 AWG) or 1.2 mm (18 AWG) wires. Resistance cannot exceed 25 Ω. The field wiring connects to a four-wire harness supplied with the unit. Notice Use shielded cable where excessive electromagnetic interference is a problem. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. Parts included Quant.Component 1 Keypad 1 Hardware pack 1 Literature pack Technical specifications Environmental Considerations Relative humidity 5% to 93% at +32°C (+90°F) Temperature (operating) 0°C to +49°C (+32°F to +120°F) Mechanical Properties Color:Red Dimensions:11.7 cm x 21 cm x 2 cm (4.6 in. x 8.2 in. x 0.8 in.) Material:CHI MEI POLYLAC PA757 ABS with UV Stabilizer. UL94-HB Fire Rated Power Requirements Current:104 mA minimum, 225 mA maximum Voltage:12 VDC nominal supplied by the control panel Ordering information D1256RB Fire Keypad The D1256RB Fire Keypad provides our one-touch function keys for user-friendly control over the system Order number D1256RB Accessories D55 Keypad Desk Stand Portable desk stand in smoke colored Plexiglas. Order number D55 D56 Surface Mount Conduit Box White surface mount box. Order number D56 D56R Red Surface Mount Conduit Box Red surface mount box. Order number D56R 2 | D1256RB Fire Keypad 3 | D1256RB Fire Keypad Represented by: North America:Europe, Middle East, Africa:Asia-Pacific:China:Latin America and Caribbean: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 203 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2016 | Data subject to change without notice 2529023371 | en, V10, 09. Feb 2016 Intrusion Alarm Systems | D1257RB Fire Annunciator D1257RB Fire Annunciator www.boschsecurity.com u Compatible with Bosch GV4 control panels, Bosch GV3 control panels, and GV2 control panels (firmware version 7.04 and higher) u Can be remotely installed in public access areas u Built-in multi-tone sounder u Easy to read vacuum fluorescent display (VDF) shows complete system status in English u Programmable custom text for each point The D1257RB Fire Annunciator is typically installed in building entrances and areas with unrestricted access because it lacks function keys. This SDI bus compatible device works with the Bosch Security Systems, Inc. GV4 control panels, GV3 control panels, and GV2 control panels (firmware version 7.04 and higher). Two navigational keys allow the user to step forward or backward through a list of system events. This allows a responding agency or persons evacuating the building to quickly and safely identify the type and location of the emergency. The annunciator has a built-in sounder that allows it to be installed out of sight. Audible tones alert personnel to fire system events and assist fire fighters to locate the annunciator. Functions Display The display uses words, numbers, and symbols to show the status of the fire system. When several events occur, each event is shown in order of priority followed by the time of occurrence. In conjunction with the 16‑character vacuum-fluorescent display (VFD), four LEDs provide the following system status indications: • Fire • Silenced • Supervisory • Trouble Certifications and approvals Region Certification USA UL UOXX: Control Unit Accessories, System(ANSI/UL 864) FM CSFM see our website FDNY-CoA 6174 FDNY-CoA 6059 [D9412GV3 & D7412GV3] FDNY-CoA 6196 Installation/configuration notes Compatible Control Panels • B9512G/B9512G-E • B8512G/B8512G-E • D9412GV4/D7412GV4/D7212GV4 1 • D9412GV3/D7412GV3/D7212GV3 1 • D9412GV2/D7412GV2/D7212GV2 1 1The D7212GV4, D7212GV3, and D7212GV2 are not listed for commercial fire applications. Mounting Considerations The annunciator is a low profile, surface-mounted unit molded in durable red plastic with three mounting holes in the base that allow secure, correct positioning during installation. Protect the surface-mounted annunciator by mounting it to a D56 or D56R Conduit Back Box. For desktop applications, the annunciator can be mounted to a D55 Desk Stand. Notice Do not install the annunciator in direct sunlight. This damages the module components and makes the display less visible. Do not mount in wet or moist locations. Wiring Considerations The annunciator connects to the control panel for data and power through a standard four-wire flying lead cable. For field wiring use 0.8 mm (22 AWG) or 1.2 mm (18 AWG) wires. Resistance cannot exceed 25 Ω. The field wiring connects to a four-wire harness supplied with the unit. Notice Use shielded cable where excessive electromagnetic interference is a problem. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. Parts included Quant.Component 1 Annunciator 1 Hardware pack 1 Literature pack Technical specifications Environmental Considerations Relative humidity 5% to 93% at +32°C (+90°F) Temperature (operating) 0°C to +49°C (+32°F to +120°F) Mechanical Properties Color:Red Dimensions:11.7 cm x 21 cm x 2 cm (4.6 in. x 8.2 in. x 0.8 in.) Material:CHI MEI POLYLAC PA757 ABS with UV Stabilizer. UL94-HB Fire Rated Power Requirements Current:104 mA minimum, 225 mA maximum Voltage:12 VDC nominal supplied by the control panel Ordering information D1257RB Fire Annunciator Red and gray case. Order number D1257RB Accessories D55 Keypad Desk Stand Portable desk stand in smoke colored Plexiglas. Order number D55 D56 Surface Mount Conduit Box White surface mount box. Order number D56 D56R Red Surface Mount Conduit Box Red surface mount box. Order number D56R 2 | D1257RB Fire Annunciator 3 | D1257RB Fire Annunciator Represented by: North America:Europe, Middle East, Africa:Asia-Pacific:China:Latin America and Caribbean: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 203 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2016 | Data subject to change without notice 2529069963 | en, V11, 09. Feb 2016 Fire Alarm Systems | D273 Photoelectric Smoke and Smoke and Heat Detectors D273 Photoelectric Smoke and Smoke and Heat Detectors www.boschsecurity.com u 12 VDC or 24 VDC input u Designed for commercial or residential use u Four-wire application u Light-emitting diodes (LEDs) indicate the status of the chamber, power, and alarm u Removable terminal block to simplify wiring connections The D273 Family includes the following detector models: Model Description D273 Four-wire D273IS1 Four-wire with an isolated 135°F (57°C) heat sensor and sounder D273TH Four-wire with 135°F (57°C) heat sensor D273THC Four-wire with 135°F (57°C) heat sensor and auxiliary relay D273THCS1 Four-wire with 135°F (57°C) heat sensor, auxiliary relay, and sounder D273THE Four-wire with 135°F (57°C) heat sensor and EOL relay D273THR2 Four-wire with 135°F (57°C) heat sensor and trouble relay D273THS1 Four-wire with 135°F (57°C) heat sensor and sounder D273THES1 Four-wire with 135°F (57°C) heat sensor, sounder, and EOL relay 1 Sounders produce 85 dB at 10 ft (3 m). 2 The trouble relay indicates both Dirty Smoke Chamber and/or Power Loss conditions. Each of the detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. System overview These detector models use an infrared (IR) LED light source and a silicon photodiode to measure light in a chamber. A fine screen covers the chamber to deter insects and reduce dust accumulation and nuisance alarms. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. When a D132B Reversing Relay Module is used, the LED does not latch on alarm. Functions Chamber Calibration Tests Check the sensitivity and calibration of any of these detectors using a visual check, a magnet test, or a voltage measurement test. Refer to the D263/D273 Families Installation Guide for specific instructions to perform these sensitivity tests. Certifications and approvals Region Certification USA UL UROX: Smoke - Automatic Fire Detectors(UL268 and A), UROX7: Smoke - Auto-matic Fire Detectors Certified for Cana-da (cULus) CSFM see our website NYC-MEA 274-93-E, Vol. VII MSFM Hong Kong HKFSD J-005/C/023 Installation/configuration notes Use smoke detectors for detection circuits that protect people. Use heat detectors for circuits that protect property. Compatible Products The following products are compatible with the D273 Family detectors: Category Product ID Product Description Control Panels These detector models are compatible with UL Listed four-wire control panels. Refer to the manufacturer’s installation instructions to select the correct EOL resistor. Modules D132B Reversing relay module Loop Supervision For loop supervision, install a Bosch Security Systems D275 Power Supervision Module and an EOL resistor after the last device on the loop. Mounting The detector has a mounting plate that attaches to a standard four-inch back box. For commercial and industrial installations in accordance with NFPA 72, space each detector 30 ft (9.2 m) apart. Wiring The terminal block accepts up to 12 AWG (ISO 2.5 mm2) wire. You can remove the terminal block from the detector for easier wiring. The terminal block snaps in and out of the detector. Parts included Quant.Component 1 Detector 1 Literature pack – Installation Manual, Technical Service Note on installation Technical specifications Environmental Considerations Relative Humidity:Up to 93%, non-condensing Operating and Storage Temperature: +32°F to +120°F (0°C to +40°C) Radio Frequency Interference (RFI) Immunity No alarm or setup on critical frequencies in the range of 26 MHz to 950 MHz. Mechanical Properties Dimensions (Diameter x H):5 in. x 2 in. (12.7 cm x 5.1 cm) Material:High impact, fire retardant ABS plastic Power Requirements Power-up Time:22 sec maximum RMS Ripple:25% of DC input maximum Voltage (stand-by):10 VDC to 30 VDC Current Draw (alarm) at 30 VDC D273, D273TH:18 mA maximum D273THC: 33 mA maximum D273THE, D273THR: 36 mA maximum D273THS: 78 mA maximum D273THCS: 90 mA maximum D273THES:96 mA maximum D273IS: 100 mA maximum Current Draw (standby) D273, D273TH, D27THC, D273THCS, D273THS: 0.1 mA maximum D273IS:15 mA D273THE, D273THES:15 mA D273THR:18 mA maximum Ordering information D273 Four‑Wire Smoke Detector Four‑wire smoke detector. Order number D273 2 | D273 Photoelectric Smoke and Smoke and Heat Detectors D273IS Four‑Wire Smoke Detector with Isolated Heat Sensor and Sounder Four‑wire smoke detector with an isolated 135°F (57°C) heat sensor and a sounder. Order number D273IS D273TH Four‑Wire Smoke/Heat Detector Four‑wire smoke detector with a 135°F (57°C) heat sensor. Order number D273TH D273THC Four‑Wire Smoke/Heat Detector with Auxili- ary Relay Four‑wire smoke detector with an isolated 135°F (57°C) heat sensor and an auxiliary relay. Order number D273THC D273THCS Four‑Wire Smoke/Heat Detector with Auxili- ary Relay and Sounder Four‑wire smoke detector with a 135°F (57°C) heat sensor, an auxiliary relay, and a sounder. Order number D273THCS D273THE Four‑Wire Smoke/Heat Detector with EOL Re- lay Four‑wire smoke detector with a 135°F (57°C) heat detector and an EOL relay. Order number D273THE D273THES Four‑Wire Smoke/Heat Detector with EOL Relay and Sounder Four‑wire smoke detector with a 135°F (57°C) heat sensor, a sounder, and an EOL relay. Order number D273THES D273THR Four‑Wire Smoke/Heat Detector with Trouble Relay Four‑wire smoke detector with a 135°F (57°C) heat sensor and a trouble relay. Order number D273THR D273THS Four‑Wire Smoke/Heat Detector with Sounder Four‑wire smoke detector with a 135°F (57°C) heat sensor and a sounder. Order number D273THS Accessories D275 Power Supervision Module Line supervision device for four-wire fire detection circuits Order number D275 D1005 Test Cable Connects a digital voltmeter to the detector's calibration pin for verifying that the detector is within its calibration range Order number D1005 DT‑2 Detector Removal Tool Use the DT‑2 to remove, replace, or test the detector head Order number DT-2 TP280 Trim Plate For retrofit and remodeling purposes; 16.2 cm (6 in.) diameter Order number TP280 3 | D273 Photoelectric Smoke and Smoke and Heat Detectors 4 | D273 Photoelectric Smoke and Smoke and Heat Detectors Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2014 | Data subject to change without notice 2700558987 | en, V5, 31. Oct 2014 Fire Alarm Systems | FMM‑100 Die‑cast Metal Fire Alarm Manual Stations FMM‑100 Die‑cast Metal Fire Alarm Manual Stations www.boschsecurity.com u Single or dual action u Terminal connections u Gold‑plated alarm contacts for corrosion resistance u Surface or weatherproof back boxes The FMM‑100 family are versatile, high‑quality, metal fire alarm manual stations. Single‑action or dual‑action models are available. All models come with a key lock and contain gold‑plated contacts to resist corrosion. Functions Operation Single-action When the bar on the front of the manual station is pulled, it latches open and is easily visible from 50 ft (15 m). Reset the activation bar by opening the manual station with the key and placing the activation bar in its normal upright position. An optional scored acrylic break rod is available. Dual-action With the dual‑action configuration the upper bar on the front of the manual station rotates inward allowing the activation bar to be grasped and operated by a single hand. Certifications and approvals Region Certification USA UL UNIU: Boxes, Non-Coded (UL38),UNIU7: Boxes, Non-Coded Certified forCanada (cULus) CSFM see our website NYC-MEA 382-94-E, Vol. VI Installation/configuration notes Compatibility Information These manual stations are compatible with all Bosch Security Systems, Inc. Fire Alarm Control Panels. Mounting Considerations These manual stations can be surface mounted on either the FMM‑100BB‑R Surface‑mount Back Box or the FMM‑100WPBB‑R Weatherproof Back Box. They can also be flush mounted on a standard single‑gang back box. Notice When properly mounted on the FMM‑100WPBB‑R Weatherproof Back Box, these manual stations meet UL requirements for outdoor use. To comply with ADA standards, the manual station must be less than 48 in. (1.2 m) above the floor for front wheelchair access and less than 54 in. (1.3 m) above the floor for side wheelchair access. Parts included Quant.Component 1 Manual station 1 D102 Key (1358 key) 1 FMM‑100GR Acrylic Break Rod 1 Hardware pack 1 Literature pack Technical specifications Environmental Relative Humidity:90% at +100°F (+38°C) Temperature (operating): -40°F to +150°F (-40°C to +66°C) Mechanical Color:Red Dimensions (H x W x D): 4.75 in. x 3.25 in. x 1.1 in. (12 cm x 8.3 cm x 2.8 cm) Material:die‑cast metal Inputs Switch Rating:1 A at 30 VDC or 125 VAC Ordering information FMM‑100SATK Single‑action Manual Station (red) Versatile, high‑quality, metal single‑action fire alarm manual station with key lock and gold‑plated contacts Order number FMM-100SATK FMM‑100SATK‑NYC Single‑action Manual Station for New York City Versatile, high‑quality, metal single‑action fire alarm manual station for New York City with key lock and gold‑plated contacts Order number FMM-100SATK-NYC FMM‑100DATK Dual‑action Manual Station (red) Versatile, high‑quality, metal dual‑action fire alarm manual station with key lock and gold‑plated contacts Order number FMM-100DATK Accessories D102 Replacement Key Replacement key (#1358) for LOCK‑1358 and the D101 lock. Order number D102 FMM‑100BB‑R Surface‑mount Back Box (red) Red cast‑metal back box Order number FMM-100BB-R FMM‑100WPBB‑R Weatherproof Back Box (red) Red cast‑metal weatherproof back box Order number FMM-100WPBB-R FMM‑100GR Scored Acrylic Break Rods Scored acrylic rods (12 per package) Order number FMM-100GR 2 | FMM‑100 Die‑cast Metal Fire Alarm Manual Stations 3 | FMM‑100 Die‑cast Metal Fire Alarm Manual Stations Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2014 | Data subject to change without notice 2708627339 | en, V2, 11. Aug 2014 SAFEPATH®4 Facility Communications System & Expansion Options SP40S Facility Communications System 2-4 Expansion Options SAFEPATH®4 2-Zone Class A or 4-Zone Class B Speaker Audio Splitter 5 SAFEPATH®4 Audio Boosters 6-7 System Diagram 8-9 SAFEPATH®4 Addressable Paging Splitter and Telephone Zone Controller 10 SAFEPATH®4 Supervised Volume Control and Remote Microphone 11 Remote Microphone Expansion Module 12 Description Page SP40S SPRM SP4Z-A/B SP-SVC SP4-TZC THE CITY OF NEW YORK DEPARTMENT OF BUILDINGS UL® 151-92-ES5361 6911-0785:157 SPB-80/4 SPB-160 SPB-320 SP4-APS Notification SAFEPATH®4 Facility Communications SP40S Description The SP40S is a Multi-Function Supervised Paging, Messaging, Background Music delivery and Emergency Voice Evacuation System with 24 VDC battery backup. The SP40S integrates with fire alarm systems and provides full control of building audible and visual notification appliances. This single channel system is capable of delivering 40 watts of supervised high fidelity audio power and 2 amps of supervised 24 VDC synchronized strobe power. It comes standard with an on-board digital voice messaging system with 8 standard messages, a hand-held microphone, power supply/battery charger and numerous additional features. The SAFEPATH4 system is expandable to 5280 watts utilizing the SPB-80/4 (80 watts and 4 amps of strobe power), the SPB-160 (160 watts) or SPB-320 (320 watts) supervised audio power boosters. All models available in 115 VAC ir 220 VAC. Applications for the SP40S • Multi-use applications—The system can function as an evacuation system, an emergency messaging system, a paging system, an employee notification system and a background music system per NFPA 72 (2002), section 6.8.4 Combination Systems • Fire code applications—The system is listed under UL Standard 864, 9th edition delivering supervised audio and voice messaging with strobes and notification appliance circuits (NAC) for visual alerting • Economic OSHA applications—The system is OSHA 1910.165 compliant; this means that it does not require reliability inspections every two months, or the required spare parts inventory • Wide ranging applications—from small to large facilities • Can connect to pagers for private alerting of emergency/ trouble conditions System Activation • Contact closure message activation Approvals & Compliance • Approvals: UL Standard 864, 9th edition, UL Standard 1711, California State Fire Marshal (CSFM), New York City (MEA), FCC Part 15 • OSHA 1910.165 and ADA Compliant • 1 Year Warranty Background Music • Capable of broadcasting from a supplied BGM source • Unique supervision method allows for full system supervision even during background music (BGM) • Line Level input for music source • Frequency Response 100 - 15KHz Strobe Inputs and Activation • 2 Amps of 24 VDC supervised strobe power with built-in Wheelock sync protocol. Power limited. • Strobe output is selectable for control of Wheelock sync protocol or non-sync operation • Strobe terminals have pass thru capability for Wheelock sync or non-sync operation • Any of the 8 messages can be dip switch selected to activate strobes • Microphone activation can be dip switch selected to activate strobes • Auxiliary activation (Remote MIC) can be dip switch selected to activate strobes • 24 VDC supervised and synchronized strobe power can be expanded to meet the requirements of the installation via connecting to optional Wheelock power boosters General Paging • Easily interfaces with most existing phone system page port, CO port and line level signals • Automatically mutes BGM • Frequency Response 275 - 6.5kHz • Night ringer or security alert connection Voice Evacuation • Complies to NFPA-72 requirements • Supervised NAC speaker and strobe circuits • Live microphone override • 8 digitally pre-recorded voice messages • Uses selectable pre-tones for messages Speaker Output • 40 watts of supervised audio power • Speaker outputs: 25V or 70.7V power limited Features 2 Audio/Technical Specifications Switch mode, Class D amplifier (40 Watts) Speaker Outputs 25V or 70.7V power limited Frequency Response Voice: 275 Hz – 6.5 kHz BGM: 100 Hz - 15 kHz Meets UL Voice Evacuation Requirements of 800 - 2800 Hz Signal to Noise Ratio better than 65 dB Dynamic Range better than 65 dB Total Harmonic Distortion less than 2% Stand by Current Draw 130 mA Alarm Current Draw 4.7 amps Inputs – Audio and Activation Priority Ordered Inputs Priority Level Type of Input On Board Microphone 1 Push to Talk (PTT) Microphone Auxiliary 2 Remote Microphone or Remote Microphone Expander Digital Message Input 1 3 Contact Closure activation Digital Message Input 2 4 Digital Message Input 3 5 Digital Message Input 4 6 Digital Message Input 5 7 Digital Message Input 6 8 Digital Message Input 7 9 Digital Message Input 8 10 Night Ringer Input 11 Contact Closure input Telephone Paging Input 12 Page port input Background Music Input 13 Line Level Input, 600 ohm, input voltage must be less then 2.5 V peak to peak, or .3 volts RMS Compatible Wheelock Products All Wheelock Speaker/Strobes All Wheelock Strobes All Wheelock Speakers All Cluster Speakers Wheelock Strobe Power Supply Live & Pre-recorded Message Announcement • Supplied with 8 pre-recorded emergency messages • Capable of in-field recording of all messages via 1/8” line level audio input jack • Preset audio levels for emergency messaging (prerecorded and live mic) - system reverts back to a pre set level regardless of the volume set for BGM or general paging • On board Push-to-Talk Microphone • Telephone paging input, disconnects BGM when in use • Auxiliary input for Remote Microphone connection Installation/Maintenance • Multiple trouble LED indicators for quick system diagnostics • Fully supervised circuitry always in effect – even during BGM and general paging (via patent pending technology) • Removable quick connect/disconnect terminals for ease of wiring, accepts #12 to #22 AWG • Power limited circuitry with Class “B” or Class “A” wiring. Class “A” only with use of Audio Splitter • Surge protected circuitry • Audio and strobe power limiter reset button Power Supply & Batteries • 24 VDC, 33AH Max rechargeable battery back-up power circuitry built-in • Batteries can be housed in the enclosure (Up to two (BAT-1212), 12 volt, 12 ampere hour batteries can fit in the enclosure. Actual battery size required will depend on speaker and/or strobe load. Batteries are sold separately). Benefits and Advantages of the Multi-Function SAFEPATH4 • One System Multi-Function Facility Communications System • Background Music (BGM) system, with patent pending supervision during BGM operation • Supervised Emergency/Fire Voice Evacuation System • Interfaces with telephone system for general paging requirements • Built in power for visual notification appliances e.g., Strobes • Expandable for larger system requirements (with optional equipment) Audio Processing • Volume and tone controls for general paging and BGM • Connectivity of optional speaker splitter modules • Dual-tone tone generator with: Code 3 Tone and Slow Whoop for alerting of system trouble • Night ringer/security alerting capability • Audio power can be expanded by connecting to optional audio power boosters -SPB-80/4 80 Watt Supervised Audio Power Booster with 4 Amp of Synchronized Strobe Power -SPB-160 160 Watt Supervised Audio Power Booster -SPB-320 320 Watt Supervised Audio Power Booster 3 Mechanical Dimensions 21” H x 16” W x 6” D (wall mount) Weight 36 lbs. (without batteries) Finish Red or black exterior enclosure Door Lock Wheelock Key-lock Message Capabilities Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters’ Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Model Number Order Code Description SP40S 9929 Multi-Function Supervised Paging, Messaging, Background Music delivery and Emergency Voice Evacu- ation System with 24 VDC battery backup circuitry. Single channel system with 40 watts of supervised audio power and 2 amps of supervised 24 VDC synchronized strobe power and 8 standard messages. (batteries not included, 2 required) Red Enclosure SP40S-B 9935 Same as above but with black enclosure SP40SE 6138 Same as above but with 220 VAC input SP40SE-B 6139 Same as above but with 220 VAC input and black enclosure BAT-1212 7390 12 volt, 12-ampere hour battery SP40S-PMK 9936 SP40S 8 Message Programmed Message Kit AM-SP40S-SMK 9937 SP40S After Market 8 Message Standard Message Kit AM-SP40S-PMK 9938 SP40S After Market 8 Message Programmed Message Kit AM-SP40S-NBT 9939 SP40S After Market Narrow Band Signal Tone Kit SP-COA 9908 C.O. Port Adapter for the SP40S - Recommended 24 VDC Power Supply is Wheelock RPS-2406 (Order Code 3770) BATC-R 5414 Battery Cabinet, Red BATC-B 5413 Battery Cabinet, Black BAT-1224 7391 12 Volt, 24Ampere Battery Cell Ordering Information 4 Message and Priority # Type of Message Voice Type Message Script 1 Fire (do not use elevators) Male Three (3) rounds of code 3 horn (followed by): “May I have your attention please! A fire emergency has been reported in the building. While this is being verified, please leave the building by the nearest exit. Do not use the elevators.” 2 Fire (do not use elevators) Female Three (3) rounds of code 3 horn (followed by): “May I have your attention please! A fire emergency has been reported in the building. While this is being verified, please leave the building by the nearest exit. Do not use the elevators.” 3 Fire Male Three (3) rounds of code 3 horn (followed by): “May I have your attention please! A fire emergency has been reported in the building. While this is being verified, please leave the building by the nearest exit.” 4 Emergency Female Three (3) rounds of code 3 horn (followed by): “May I have your attention please! An emergency has been reported in the building. While this is being verified, please leave the building by the nearest exit.” 5 Emergency Male Three (3) rounds of code 3 horn (followed by): “May I have your attention please! An emergency has been reported in the building. While this is being verified, please leave the building and report to the designated assembly area for your group.” 6 Weather Male Five (5) seconds of 1kHz tone (followed by): “May I have your attention please! The National Weather Service has issued a severe weather warning for our area.” 7 All Clear Male Five (5) seconds of 1kHz tone (followed by): “May I have your attention please! The building emergency has ended. An all clear has been given. Please resume normal activities.” 8 Test Male Five (5) seconds of 1kHz tone (followed by). “May I have your attention please! This is a test of the Wheelock evacuation system, repeat, this is only a test.” • Each message can be selected to have a code 3 pre-alert tone, a 1kHz continuous pre-alert tone, or no pre-alert tone • Post-tones are also selectable and match the pre-tones for individual messages • Any of the 8 messages are field programmable to record your own custom message • Each message length is 30 seconds • A 1/8” line level audio input jack is supplied for message recording • A two step recording procedure is required to ensure and verify that the standard message will be permanently erased • Factory programmed messages are available for custom messages • Contact customer service for additional information • Form is required and can be downloaded from www.wheelockinc.com Note: For telephone paging, the SP40S can connect directly into the page port of the local phone system. If a page port is inaccessible, the SP-COA (C.O. Port Adapter for the SP40S) may be used to connect the SP40S to an unused C.O. port or stand-alone telephone. 5 SAFEPATH®4 2-Zone Class A or 4-Zone Class B Speaker Audio Splitter 2-Zone Class A or 4-Zone Class B Speaker Audio Splitter For operation with SAFEPATH®4 Family of Products: SP40S, SP40/2, SPB-320, SPB-160, SPB-80/4 Description: Supervised 2-Zone Class A or 4-Zone Class B Speaker Audio Splitter for the SP40S, SP40/2 or Audio Boosters. Enables a single supervised speaker audio output to drive up to two Class A supervised speaker audio outputs or four Class B supervised speaker audio outputs. Applications: Features: • Approvals: UL Standard 864, 9th edition, and California State Fire Marshal (CSFM), New York City (MEA) • UFC 04-021-01 2002 Compliant, including October 2007 Draft • Expands one zone to up to 2 zones of supervised speaker audio output in Class A • Expands one zone to up to 4 zones of supervised speaker audio output in Class B • Each Class A zone can accept up to 40 watts of audio • Each Class B zone can accept up to 40 watts of audio • Operates on either 25V or 70.7V RMS • Mounts inside the enclosure of the SP40S, SP40/2 or Audio Boosters • Power and Trouble LED’s • Individual zone short and open LED indication • Capable of detecting wiring faults • Removable wiring terminals for quick connect/ disconnect accepting 12–22 AWG • All output circuitry is Power Limited • Space provided to allow for naming of the zones • Powered by 24VDC, supplied by the either the SP40S, SP40/2 or Audio Boosters • Standby and Alarm current at 24VDC is 15mA Model Order Code Description SP4Z-A/B 9900 Supervised 2-Zone Class A or 4-Zone Class B Speaker Audio Splitter for the SP40S, SP40/2 or Audio Boosters SPMB4Z 9907 Mounting Bracket for the SP4Z-A/B is required when used with the Audio Boosters Ordering Information: • Provides for expansion of one zone to up to 2 zones of supervised speaker audio output in Class A • Provides for expansion of one zone to up to 4 zones of supervised speaker audio output in Class B Note: The Speaker Splitter-Mounting Bracket (SPMB4Z) is required when the Speaker Splitter is used in Audio Boosters. The SPMB4Z can support two splitters. 6 SAFEPATH®4 Audio Boosters Description Features SPB-320 320 Watt Supervised Audio Power Booster (Four 80 watt circuits) SPB-160 160 Watt Supervised Audio Power Booster (Two 80 watt circuits) SPB-80/4 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronizable Strobe Power (Two 2 Amp circuits) Supervised Facility Communication and Emergency Voice Evacuation Audio and Audio/Strobe Power Boosters, UL Standard 1711 and UL Standard 864, 9th edition with 24VDC battery backup capabilities. Designed to provide for additional supervised audio power for live voice, pre- recorded messages or background music (BGM). Fully supervised patent pending circuitry is always in effect even during BGM. The SPB-80/4 also provides 4 Amps of 24 VDC Supervised and Synchronized Strobe Power. The SPB-320, SPB-160 and the SPB-80/4 easily connects to the Wheelock SP40S or SP40/2. Multiple SPB-320, SPB- 160 and SPB-80/4 Audio Boosters can be inter-connected to accommodate large installations with supervised audio power and also supervised and synchronized strobe power requirements. The SPB-320 draws 2.4 watts of audio input power to properly operate and provide additional supervised audio output power. The SPB-160 and the SPB-80/4 draws 1.2 watts of audio input power to properly operate and provide additional supervised audio output power. A maximum of 5,280 watts of supervised audio power can be achieved. Additional strobe power can be obtained via a combination of SPB-80/4 or Wheelock Power Supplies/Chargers. Power Supply & Batteries • Fully supervised patent pending circuitry always in effect even during BGM • Power limited circuitry • Class D amplifiers • Internal battery charger and power supply • Required batteries fit inside the enclosure (sold separately) • SPB-320 requires four 12 VDC, 12 AH batteries • SPB-160 and SPB-80/4 require two 12 VDC, 12 AH batteries Outputs: • SPB-320 has four 80 watt speaker output circuits • SPB-160 has two 80 watt speaker output circuits • SPB-80/4 has one 80 watt speaker output circuit and two 2 amp strobe circuits (4 amps total) • Supervised Audio Speaker outputs: 70V or 25V field selectable (all boosters must be either 70 V or 25 V) • Expansion output (supervised, 24VDC at .5A in alarm condition) used for connecting multiple boosters • DC output (unsupervised for optional splitter power). Each speaker circuit (four for the SPB-320, two for the SPB-160, one for the SPB-80/4) can connect to speaker splitters Approvals & Compliance • Approvals: UL Standard 864, 9th edition, UL Standard 1711, California State Fire Marshal (CSFM), New York City (MEA) • OSHA 1910.165, ADA and UFC 04-021-01 2002 Compliant, including October 2007 Draft • 1 Year Warranty System Activation: Audio • 70V or 25V input from the SP40S or SP40/2 • 1 Volt input from SP4-RMX System Activation: Strobe (SPB-80/4) • 8 - 33VDC NAC input connected to the strobe input Applications • Provides for additional supervised audio power for large installations • Provides for additional supervised and synchronizable strobe power for large installations • Can be used in new construction as well as in retrofit construction SPB-80/4 SPB-160 SPB-320 7 Inputs: • Audio Speaker Inputs: 70V or 25V, field selectable • Auxiliary in (for alarm input signal) SPB-80/4 Strobe Features: • Two 24VDC 2 Amps, NAC supervised, synchronizable, power limited, Class B strobe outputs • Selectable outputs; Wheelock sync, pass through, or constant DC • Trouble LED’s for open and short output conditions • Alarm indicator: LED’s for Strobe and Expansion Outputs Mechanical: SPB-160, SPB-80/4 • Dimensions: 21” H x 16” W x 6” D (wall mount) • Weight: 36 lbs. (without batteries) • Finish: Red exterior enclosure • Door Lock: Wheelock key-lock SPB-320 • Dimensions: 36” H x 24” W x 6” D (wall mount) • Weight: 80 lbs. (without batteries) • Finish: Red or black exterior enclosure • Door Lock: Wheelock key-lock Model Order Code Description SPB-320 9918 320 Watt Supervised Audio Power Booster (Four 80 watt circuits) SPB-320E 6336 320 Watt Supervised Audio Power Booster (Four 80 watt circuits), 220 VAC input SPB-320E-B 6353 320 Watt Supervised Audio Power Booster (Four 80 watt circuits), 220 VAC input, black enclosure SPB-160 8989 160 Watt Supervised Audio Power Booster (Two 80 watt circuits), red enclosure SPB-160-B 9930 160 Watt Supervised Audio Power Booster (Two 80 watt circuits), black enclosure SPB-160E 6149 160 Watt Supervised Audio Power Booster (Two 80 watt circuits), 220 VAC input SPB-160E-B 6150 160 Watt Supervised Audio Power Booster (Two 80 watt circuits), 220 VAC input, black enclosure SPB-80/4 8988 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power (Two 2 Amp circuits), red enclosure SPB-80/4-B 9931 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power (Two 2 Amp circuits), black enclosure SPB-80/4E 6147 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power (Two 2 Amp circuits), 220 VAC input SPB-80/4E-B 6148 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power (Two 2 Amp circuits), 220 VAC input, black enclosure SPMB4Z 9907 Speaker Splitter Mounting Bracket for SPB-320, SPB-160 or SPB-80/4 Ordering Information Technical Specifications: • 120VAC, 3.8A, 60 Hz input • SP40SE Models 240 VAC, 2.5A, 50-60 Hz • Standby current draw: 120mA, per amplifier board • Alarm current draw: 9 Amps, per amplifier board SPB-80/4 and SPB-160 have one amplifier board SPB-320 has two amplifier boards • System Frequency Response: Voice 400 Hz - 6.5 kHz BGM 275 Hz - 15 kHz • Removable quick connect/disconnect terminals, accept 12 - 22 AWG • Multiple LED’s for easy indication of system diagnostic conditions • Signal to Noise Ratio: > 70 dB • Dynamic Range: > 65 dB • Total Harmonic Distortion: 2% Note: The Speaker Splitter-Mounting Bracket (SPMB4Z) is required when the Speaker Splitter is used in Audio Boosters. The SPMB4Z can support two splitters. 6 8 SP40S FACP SP4- TZC BGM Telephone NPS MPS SP4- RMX SPRM SPRM SPRM SP4-APS SP4-3MEM This drawing is for illustrative purposes only Legend: BGM Background Music DV Digital Voice Message Expander FACP Fire Alarm Control Panel MPS Pull Station NPS Push Station Wheelock Strobe Power Supplies SP40S Supervised Multi-Function Communication System SPB-80/4 80 Watt Audio Booster & 4 Amps of Strobe Power SPB-160 160 Watt Audio Booster SPB-320 320 Watt Audio Booster SPRM Remote Microphone SP4-RMX Remote Microphone Expansion Module SP4-TZC Telephone Zone Controller SP4-APS Addressable Paging Splitter SP4Z-A/B Speaker Splitter SP4-SVC Supervised Volume Control Strobe Speaker Speaker Strobe Cluster Speaker DV Volume Control S SPB-80/4 SP4-APS SPB-160 SP4Z-A/B SP4-APS SPB-320 SP4-APS SP4Z-A/B SPB-160 SP4-APS SP4-APS Wheelock Strobe Power Supply Wheelock Strobe Power Supply SP4-APS SP4-APS SPB-320 SP4-APS SP4-APS SP4-APS SP4Z-A/B SPB-160 SP4-APS SP4-APS V V V V 98 SP40S FACP SP4- TZC BGMTelephone NPS MPS SP4- RMX SPRMSPRMSPRM SP4-APS SP4-3MEM This drawing is for illustrative purposes only Legend: BGMBackground Music DVDigital Voice Message Expander FACPFire Alarm Control Panel MPSPull Station NPSPush Station WheelockStrobe Power Supplies SP40SSupervised Multi-Function Communication System SPB-80/480 Watt Audio Booster & 4 Amps of Strobe Power SPB-160160 Watt Audio Booster SPB-320320 Watt Audio Booster SPRMRemote Microphone SP4-RMXRemote Microphone Expansion Module SP4-TZCTelephone Zone Controller SP4-APSAddressable Paging Splitter SP4Z-A/BSpeaker Splitter SP4-SVCSupervised Volume Control Strobe Speaker Speaker Strobe Cluster Speaker DV Volume Control S SPB-80/4 SP4-APS SPB-160 SP4Z-A/B SP4-APS SPB-320 SP4-APS SP4Z-A/B SPB-160 SP4-APS SP4-APS Wheelock Strobe Power Supply Wheelock Strobe Power Supply SP4-APS SP4-APS SPB-320 SP4-APS SP4-APS SP4-APS SP4Z-A/B SPB-160 SP4-APS SP4-APS V V V V SAFEPATH®4 Applications: Features: • Allows selections of speaker zones via a telephone keypad (DTMF tones) • UFC 04-021-01 2002 Compliant, including October 2007 Draft • One SP4-TZC (controller) can control up to 17 SP4-APS (splitters) • Telephone page input connects to stand alone telephone, unused CO port, page port • USB connection for logical zone grouping and BGM programming (supports Windows 2000 and Windows XP) • Up to 9 logical zones, (a logical zone is a user selected group of up to 5 zones, individual or fixed) • RS-485 digital control to the SP4-APS speaker splitters • Connects to the SP40S or SP40/2 via the BGM input • The combination of 1 SP4-TZC (controller) and up to 17 SP4-APS (splitters) can provide: • Connects to the SP40S or SP40/2 to control selectable paging and background music (BGM) • Ability to access individual or multiple speaker zones throughout the SP40S or SP40/2 system via the telephone Addressable Paging Splitter and Telephone Zone ControllerSP4-APS Addressable Paging Splitter SP4-TZC Telephone Zone Controller Class B 4 zones per splitter Up to 68 individual zones (17 splitters) 17 fixed zones (groups of 4) 9 logical zones Class A 2 zones per splitter Up to 34 individual zones (17 splitters) 17 fixed zones (groups of 2) 9 logical zones SP4-TZC Telephone Zone Controller: • Connects to the SP40S or SP40/2 • Auto programmable • Custom user programmable (for logical zones) • All call or selected zone(s) telephone paging • Background music (BGM) zone(s) selectable • Telephone input and background music (BGM) input • Enclosure for the SP4-TZC (controller): Dimensions: 13”H x 7.6”W x 2.15”D Color: Black Wall mountable • Requires 24 VDC, model RPS-2406 SP4-APS Addressable Paging Splitter: • Addressable speaker zone splitter • Mounts inside the SP40S, SP40/2, SPB-80/4, SPB-160 or SPB-320 • Operates on 24 VDC, supplied by the SP40S, SP40/2, SPB-80/4, SPB-160, SPB-320 • Handles 40 watts of supervised audio per zone • UL Standard 864, 9th edition listed Model Order Code Description SP4Z-APS 9920 Addressable Paging Splitter SP4-TZC 9921 Telephone Zone Controller TZC-USB 9923 SP4-TZC Programming Cable Ordering Information: 10 Description: Remote Microphone for use with the SAFEPATH®4 Facility Communications System - SP40S, SP40/2 or SP4-RMX Applications: • Provides for an additional microphone in a remote location • Can be mounted up to 2,000 feet away from the SP40S or SP40/2 Features: Model Order Code Description SPRM 8996 Remote Microphone for use with the SP40S, SP40/2, SPB-320, SPB-160, SPB-80/4 or SP4-RMX, red plate SPRM-GP 9927 General Paging Microphone for use with the SPB-320, SPB-160, or SPB-80/4, black plate Ordering Information: • Approvals: UL Standard 864, 9th edition and California State Fire Marshal (CSFM) • UFC 04-021-01 2002 Compliant, including October 2007 Draft • Supervised hand held push to talk microphone • Key required to enable remote microphone use • Individual front panel LED indication for; System Normal, System Trouble and Alarm • When used with the SP40S or SP40/2, the priority level is 2, the SP40S or SP40/2 on board microphone is always priority 1 • Remote microphone usage disengages background music and general paging • Voice frequency response: 275 Hz - 6.5 kHz • Requires 24VDC, supplied by the SP40S, Audio Boosters, or SP4-RMX • Input current: Standby: 23mA Alarm: 30mA • Audio output level: 1.05V RMS • 6 wire connection to the SP40S, SP40/2 or SP4-RMX • Mounting plate is red and measures, 8 3/4” x 5 ¼”, fits into a 4 gang back box • All output circuitry is Power Limited SAFEPATH®4 Remote Microphone 11 Applications: Features: Model Order Code Description SP-SVC 9926 Supervised Volume Control for use with the SAFEPATH®4 system Ordering Information: SAFEPATH®4 Supervised Volume Control SP-SVC Supervised Volume Control • Supervised volume control for use with UL Listed Life Safety Applications • UFC 04-021-01 2002 Compliant, including October 2007 Draft • Can handle up to 35 watts of 70.7 volt audio power input • Adjustment settings: 0 – 10, in 3dB increments • Operates in Class B or Class A wiring (for Class A, the SP4-APS is required) •· Requires a double gang, 3½” deep back box or 4” square and 1-1/2” deep box with a 1-1/2” extension ring • Stainless steel mounting plate with a black knob • UL Standard 864 and California State Fire Marshal (CSFM) listed for use with the SP40S, SP40/2 or SPB Audio Boosters • OSHA 1910.165 and ADA compliant • Maximum RMS current 10.0mA • Allows manual volume setting for telephone paging and background music for a specific speaker or speaker zone • The selected adjustment will not affect the volume setting of emergency prerecorded messages or live microphone usage 10 12 Applications: • Expands one remote microphone (SPRM) from the SP40S or SP40/2 to three remote microphones • Two SP4-RMX modules can be cascaded together to provide up to six remote microphones from the SP40S or SP40/2 • Provides for an auxiliary input for connection of an external VoiceLink message repeater for additional messages Features: Model Order Code Description SP4-RMX 9919 Remote Microphone Expansion Module Ordering Information:• The SP4-RMX will provide the capability of connecting up to (3) three Remote Microphone Stations (SPRM) • When connected to the SP40S or SP40/2, two SP4- RMX units can be cascaded together to provide up to six remote microphones • Provides for an auxiliary input for connection of an external message repeater, for additional messages • Can accept a line level input for broadcasting of other information • When the SP4-RMX is connected to the SP40S or SP40/2, the entire system benefits from the additional microphone capability • Can be connected to Audio Boosters for general (non- alarm) paging with use of SPRM-GP • UL Standard 864 listed • OSHA 1910.165, ADA and UFC 04-021-01 2002 Compliant, including October 2007 Draft • Multiple on board diagnostics with 3 status conditions: standby, alarm, and trouble • Operates on 24 VDC, supplied by the SP40S, SP40/2, SPB-80/4, SPB-160, SPB-320 • The SP4-RMX is an external module Enclosure dimensions: 13”H x 7.6”W x 2.15”D SAFEPATH®4 Remote Microphone Expansion Module Microphone and message priority levels when the SP4-RMX is used with the SP40S or SP40/2: SP4-RMX Remote Microphone Expansion Module Priority Level Device Microphones 1 SP40 on board microphone 2 SP4-RMX, remote microphones #1, 2, 3 (set priority or First In First Out) 3 SP4-RMX, auxiliary input only SP40S Standard Messages 4 SP40S message 1 5 SP40S message 2 6 SP40S message 3 7 SP40S message 4 8 SP40S message 5 9 SP40S message 6 10 SP40S message 7 11 SP40S message 8 Color: Black Wall mountable 1312 Features: Model Number Order Code Description SP40S 9929 Multi-Function Supervised Paging, Messaging, Background Music and Emergency Voice Evacuation System with 24 VDC battery backup circuitry. Single channel system with 40 watts of supervised audio power and 2 amps of supervised 24 VDC synchronized strobe power and 8 standard messages. (batteries not included, 2 required) Red enclosure SP40S-B 9935 Same as above but with black enclosure SP40S-PMK 9936 SP40S 8 Message Programmed Message Kit AM-SP40S-SMK 9937 SP40S After Market 8 Message Standard Message Kit AM-SP40S-PMK 9938 SP40S After Market 8 Message Programmed Message Kit AM-SP40S-NBT 9939 Sp40S After Market Narrow Band Signal Tone Kit SP-COA 9908 C.O. Port Adapter for the SP40S or SP40/2 - Recommended 24 VDC Power Supply is Wheelock RPS- 2406 (Order Code 3770) SP4Z-A/B 9900 Supervised 2-Zone Class A or 4-Zone Class B Speaker Audio Splitter for the SP40S, SP40/2 or Audio Boosters SPMB4Z 9907 Mounting Bracket for the SP4Z-A/B is required when used with the Audio Boosters SPB-320 9918 320 Watt Supervised Audio Power Booster (Four 80 watt circuits) SPB-160 8989 160 Watt Supervised Audio Power Booster (Two 80 watt circuits), red enclosure SPB-160-B 9930 160 Watt Supervised Audio Power Booster (Two 80 watt circuits), black enclosure SPB-80/4 8988 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power (Two 2 Amp circuits), red enclosure SPB-80/4-B 9931 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power (Two 2 Amp circuits), black enclosure SP4Z-A/B 9900 Supervised 2-Zone Class A or 4-Zone Class B Speaker Audio Splitter for the SP40S, SP40/2, SPB-320, SPB-160 or SPB-80/4 SPMB4Z 9907 Speaker Splitter Mounting Bracket for SPB-320, SPB-160 or SPB-80/4 SP4Z-APS 9920 Addressable Paging Splitter SP4-TZC 9921 Telephone Zone Controller TZC-USB 9923 SP4-TZC Programming Cable SP-SVC 9926 Supervised Volume Control for use with the SAFEPATH®4 System SPRM 8996 Remote Microphone for use with the SP40S, SP40/2, SPB-320, SPB-160, SPB-80/4 or SP4-RMX, red plate SPRM-GP 9927 General Paging Microphone for use with the SPB-320, SPB-160 or SPB-80/4, black plate BATC-R 5414 Battery Cabinet, Red BATC-B 5413 Battery Cabinet, Black BAT-1212 7390 12 Volt, 12 Ampere Battery Cell BAT-1224 7391 12 Volt, 24Ampere Battery Cell BAT-1265 7392 12 Volt, 65 Ampere Battery Cell Ordering Information The system shall be a multi-purpose NFPA compliant, supervised, general-purpose audio, and fire/emergency evacuation system. The system shall be a single channel voice evacuation system incorporating supervision during the broadcasting of background music and general paging. The system shall be capable of delivering 40 watts of supervised audio power and 2 amps of supervised 24 VDC synchronized strobe power. Minimum supervised audio power shall be 40 watts, expandable to 5280 watts, depending on system configuration and with additional modules and power boosters. Supervised 24 VDC synchronized strobe power shall be 2 amps, expandable to the requirements of the installation. The system shall be capable of operating from a 120 VAC power source. E models shall be capable of operating from a 240 VAC power source. All models shall have a 24 VDC battery backup. Standard on-board system features shall include: digital voice messaging, a hand-held push-to-talk microphone with override priority, and a power supply/ battery charger. The system shall be capable of interfacing with telephone systems for general paging announcements and will have night ringer capabilities. Form C contacts shall be provided for system alarm and trouble conditions. The system shall have 8 message contacts with contact closure activation. Background music input voltage shall be capable of handling less then 2.5 V peak to peak or less then .3 volts. The system shall have thirteen priority ordered inputs, including: On Board Microphone, Auxiliary Input (Line Level), 8 Digital Messages, Night Ringer Input, Telephone Paging Input, and Background Music Input. The system shall have preset audio levels for emergency messaging (prerecorded and live mic). The system shall revert back to a preset level regardless of the volume set for background music (BGM) or general paging. Background music inputs can be an AM/FM tuner, cassette, CD, MP3, or any other remote source. The system shall be supplied with 8 pre-recorded messages and be capable of in-field recording of customer unique messages. The system shall have a dual-tone tone generator with Code-3 Tone and Slow Whoop. When the system is on battery power, telephone page, night ring and background music shall be disengaged. The panel shall have power-limited circuitry with an internal battery charger and power supply. The power supply/charger section shall be able to charge 24 VDC batteries with a maximum capacity of 33 amp hours. Up to two 12 VDC, 12 AH batteries may be housed in the enclosure. Batteries larger than 12 Ah shall be housed in a separate enclosure such as the Cooper Wheelock BATC or equivalent. Batteries shall be supplied separately. The system shall have power limited circuitry and class B wiring. Wiring terminal blocks will be removable and accept #22 - #12 AWG wire. Audio output voltage shall be selectable for 25V or 70.7V. The voice (live microphone or recorded message) frequency response shall be 275 Hz – 6.5 kHz, background music frequency response shall be 100 Hz - 15 kHz. Stand by current draw shall be 140mA. Alarm current draw shall be 4.7 amps. The signal to noise ratio shall be better than 65 dB, dynamic range shall be better than 65 dB, total harmonic distortion shall be less than 2%. The system shall be wall mountable, enclosed in a steel locking enclosure. The required batteries for 40-watt systems shall fit inside the enclosure. The 40 watt system shall weigh no more than 36 lbs (without batteries) and its dimensions shall not exceed 21” H x 16” W x 6” D. Approvals for the system shall include: UL Standard 864, 9th edition, UL Standard 1711, FCC part 15, California State Fire Marshal (CSFM) and New York City (MEA). The system shall be OSHA 1910.165, ADA and UFC 04-021-01 2002 (including October 2007 Draft) compliant. 1 Year Warranty. SAFEPATH®4 Audio Boosters The Wheelock SPB-320, SPB-160 and SPB-80/4 Audio Boosters shall be NFPA compliant supervised audio and supervised 24VDC synchronized strobe power boosters (some models will have supervised 24VDC synchronized strobe booster capability). The booster shall have 24VDC battery backup capabilities. The booster shall have the capability to supervise the circuitry during playback of background music. The booster shall have the capability to be inter-connected to accommodate large installations with supervised audio power and also supervised and synchronized strobe power requirements. Three versions of the booster shall be made available: SPB-80/4, (80 watts of supervised audio power and 4 amps of supervised and synchronized strobe power), SPB-160 (160 watts of supervised audio) or SPB-320 (320 watts of supervised audio). Each booster shall use 1.2 watts of audio input power (The SPB-320 requires 2.4 watts of audio power) to properly operate and provide additional supervised audio output power. A combination of boosters can be added together to provide for a maximum of 5,280 watts of supervised audio power. Additional strobe power can be obtained via a combination of boosters. The audio section of the booster shall be connected via a selectable 70V or 25V input from the Wheelock SP40S. The strobe section of the booster shall be divided into two sections each supplying two Amps of 24VDC, NAC, supervised, synchronizable, power limited, Class B strobe outputs, with selectable outputs offering Wheelock sync, pass through, or constant DC and can be activated via 8-33VDC NAC input or contact closure. The internal battery charger/power supply shall be capable of charging 24 VDC batteries with a maximum capacity of 33 amp hours. The enclosure shall be capable of housing the correct number of 12 VDC rechargeable batteries (SPB-80/4 (2), SPB-160 (2), SPB-320 (4)) with a maximum capacity of 12 Amp hours. Batteries with a larger capacity require an external battery enclosure(s) such as the Cooper Wheelock BATC or equivalent. The boosters shall have power-limited circuitry and be a class D amplifier with an internal battery charger and power supply. The required batteries (purchased separately) shall fit inside the enclosure (two 12VDC, 12 AH for the SPB-80/4 or SPB-160 and four 12 VDC, 12 AH for the SPB-320). The booster shall operate on 120VAC, 3.8A, 50 – 60 Hz input. E model boosters shall operate on 240 VAC, 2.5A, 50 – 60 Hz input. The SPB-80/4 or SPB-160 standby current draw shall be 120mA and alarm current draw shall be 9 Amps. The SPB-320 consists of two SPB-160’s. Each SPB-160 shall have its own power supply and battery charger. The voice frequency response shall be 400 Hz – 6.5 kHz +/- 3 dB, the BGM frequency response shall be 275 Hz - 15 kHz +/- 3 dB. Removable quick connect/disconnect terminals that accept 12 -22 AWG shall be used. Multiple LED’s for easy indication of system diagnostic conditions shall be present on the PC board. The Signal to Noise Ratio shall be > 70 dB, the dynamic range shall be > 65 dB, the Total Harmonic Distortion spec shall be 2%. The booster shall be wall mountable, enclosed in a steel locking enclosure, with a red finish. Approvals for the booster shall include; UL Standard 864, 9th edition, UL Standard 1711, CSFM and MEA. The system shall be OSHA 1910.165, ADA and UFC 04-021-01 2002 (including October 2007 Draft) compliant. The booster shall carry a 1 Year Warranty. The SPB-80/4 & SPB-160 enclosure dimensions are 21” H x 16” W x 6” D and the SPB-320 enclosure dimensions are 36” H x 24” W x 6” D. Architects and Engineers Specifications SP40S Facility Communications System 14 15 4 Zone Class B Speaker Splitter The Wheelock SP4Z-A/B shall be UL Standard 864, 9th edition, California State Fire Marshal (CSFM) and New York City (MEA) approved, 2-Zone Class A or 4-Zone Class B Speaker Splitter for operation with the Wheelock, SP40S, SP40/2, SPB-80/4, SPB- 160 and SPB-320. The SP4Z-A/B shall enable a single supervised speaker audio output to drive up to two Class A supervised speaker audio outputs or four Class B supervised speaker audio outputs. Each Class A zone shall be capable of accepting up to 40 watts and operate on either 25 or 70.7V RMS of audio input. Each Class B zone shall be capable of accepting up to 40 watts of audio and operate on either 25 or 70.7V RMS of audio input. The SP4Z-A/B shall be capable of supporting live microphone paging, prerecorded emergency voice evacuation messages, supervised background music and general paging announcements. The SP4Z-A/B shall mount inside the enclosure of the SP40S, SP40/2, SPB-80/4, SPB-160 and SPB-320 and shall have power and trouble LED’s with individual zone short and open LED indication. The SP4Z-A/B shall be capable of detecting wiring faults. The SP4Z-A/B shall be powered by 24VDC, which is to be supplied by the SP40S, SP40/2, SPB-80/4, SPB-160 or SPB-320. Standby and Alarm current at 24VDC shall be 15mA. Removable wiring terminals for quick connect/disconnect accepting 12–22 AWG shall be incorporated. All output circuitry shall be power limited. Space shall be provided to allow for naming of the zones. Addressable Paging Splitter and Telephone Zone Controller The Wheelock Addressable Paging Splitter (SP4-APS) and Telephone Zone Controller (SP4-TZC) shall be used to control and direct telephone paging and background music zones connected to the SAFEPATH4 Multi-Function Facility Communication System using an RS485 connection. The Addressable Paging Splitter (SP4-APS) shall be UL Standard 864, 9th edition and California State Fire Marshal (CSFM) approved, addressable and supervised 2-zone Class A or 4-zone Class B Speaker splitter. The SP4-APS shall be used with Wheelock’s SP40S or SP40/2 panel and the Audio Booster (SPB-160, SPB-80/4, and SPB-320) panels. Each SP4-APS shall have a single audio input capable of 25 Vrms or 70.7 Vrms at a maximum of 80 Watts. The input audio power shall be distributed to the zone connections with the total not exceeding the input and no zone exceeding 40 Watts. When audio boosters are connected, each audio booster module shall consume 1.2 Watts from the total input power of the SP4-APS. The splitter shall be mounted inside the SP40S, SP40/2 or Audio Booster that it is associated with, and it shall operate on 24VDC supplied by the supported module. The SP4-APS shall contain 16 LED indicators used to monitor and troubleshoot the module. The Telephone Zone Controller Module (SP4-TZC) shall be used to address the output zones on the SP4-APS. The SP4-TZC shall be capable of supporting 17 SP4-APS speaker splitter modules and shall be capable of addressing all zones at once (“All Call”), a maximum of 68 separate zones, 17 fixed zone groups and 9 programmed logical zone groups. This shall be accomplished using two digit DTMF tones from a page port, an unused CO port, or a stand alone telephone with a loop start circuit. Also, the SP4- TZC shall be able to select zones for background music. The SP4-TZC has the following inputs: Power, USB port, Background Music (BGM), Page Audio in. The outputs are: Audio out and RS485 Digital Control. The basic operating parameters of the SP4- APS shall be pre-programmed. Customized programming shall be accomplished using a USB cable and programming computer software. The SP4-TZC shall be powered using a 24VDC filtered and regulated power supply such as the Wheelock RPS-2406. The Controller Module assembly is mounted in a metal enclosure measuring 13”L x 7 5/8”W x 2”D. Supervised Volume Control The Wheelock SP-SVC shall be UL Standard 864, 9th edition approved, supervised volume control for use with the SAPEPATH®4 Facility Communications System. The SP-SVC shall provide for manual volume setting for telephone paging and background music for a specific speaker or speaker zone. The selected adjustment will not affect the volume setting of emergency prerecorded messages or live microphone usage. The SP-SVC shall be capable of handling up to 35 watts of audio power @ 70.7 volts or 4 watts audio power @ 25 volts and shall operate on either 70.7 or 25 volt input from an SP40S or Audio Booster. The SP-SVC shall be capable of operating in Class B or Class A wiring configurations (for Class A, the SP4-APS is required). The SP-SVC shall receive operating power from an Audio Booster, SP40S or SP40/2. Volume adjustment settings shall be off, 1 – 10, in 3dB increments. The SP-SVC shall be supplied with a stainless steel mounting plate with a black knob and require a double gang, 3½” deep back box for mounting. Remote Microphone The Wheelock SPRM shall be UL Standard 864, 9th edition and California State Fire Marshal (CSFM) approved, Remote Microphone for use with the SAFEPATH®4 Facility Communications System. The SPRM shall be a supervised hand held push to talk microphone and a key shall be required to enable remote microphone use. (Same key as SP40S or SP40/2) Removable wiring terminals for quick connect/disconnect accepting 12 – 22 AWG shall be incorporated. All output circuitry shall be power limited. Individual front panel LED’s shall be provided for indication of System Normal, System Trouble and Alarm. Multiple on board diagnostic LED’s shall be provided. When used with the SP40S or SP40/2, the priority level shall be number two. Remote microphone usage shall disengage background music and general paging. Voice frequency response shall be 275 Hz - 6.5 kHz +/- 2.4 dB. Power requirements shall be 24VDC and will be supplied by the SP40S or SP40/2. Input current for Standby shall be 26mA and for Alarm 38mA. Audio output level shall be 1.05V RMA. There shall be a 6-wire connection to the SP40S or SP40/2. The mounting plate shall be red and measure, 8 3/4” x 5 ¼”, and shall fit into a 4 gang back box. Architects and Engineers Specifications 16 V2003-S 09/11 NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Note: Refer to the products Installation Instructions for proper installation, wiring procedures and any additional specifications. Remote Microphone Expansion Module The Wheelock SP4-RMX Remote Microphone Expansion Module shall be UL Standard 864, 9th edition and California State Fire Marshal (CSFM) approved for use with the SAFEPATH®4 SP40S Facility Communications System. The SP4-RMX shall be a supervised outboard expansion module for use with the SAFEPATH®4 system. It shall be used to expand the number of optional supervised Remote Microphone (SPRM) modules up to three. Two SP4-RMX Remote Microphone Expansion Modules can be connected to the SP40S or SP40/2 and shall have the capability of providing the SP40S or SP40/2 with up to six system wide “All Call” Remote Microphone (SPRM) modules*. The SP4-RMX can be programmed to provide either priority override for each SPRM module input or First In First Out. First In First Out allows the active SPRM to complete its communication before another SPRM can be used. All output circuitry shall be power limited. Multiple on board diagnostic LED indicators shall be provided. All wiring shall be connected to the module using quick connect/disconnect wiring terminals, capable of accepting 12 – 22 AWG wiring. The SP4-RMX PCB assembly is mounted in a metal enclosure measuring 13”L x 7 5/8”W x 2”D. The SP4-RMX can support each SPRM at a range up to 2000 feet. *The SP4-RMX can also be connected to Audio Booster for general (non-alarm) paging with use of SPRM-GP. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 1 Year Warranty NotificationCooper Notification is NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com FL Location 7246 16th Street East, Suite 105 Sarasota, FL 34243 P: 941-487-2300 F: 941-487-2389 VA Location 103 West Broad Street, Suite 500 Falls Church, VA 22046 P: 877-459-7726 F: 703-294-6560 POWERPATH™ NAC POWER SUPPLIES Description The Wheelock Series PS-6 and PS-8 are 24VDC, filtered and regulated, supervised remote power supply/battery chargers are used for supervision and expanded power driving capability of Fire Alarm Notification Appliance Circuits. The PS-6 provides 6 amps of power distributed across 4 outputs, while the PS-8 provides 8 Amps across 4 output. In addition the PS-8 provides additional room in the chassis for accessories like an Addressable Control Module, with mounting studs. The Power Supplies may be connected to any 12V or 24V (FWR or DC) Fire Alarm Control Panel (FACP) by using a Notification Appliance Circuit (NAC) or a “Dry Contact”. Primary applications include NAC expansion (supports ADA requirements) and auxiliary power to support system accessories. This unit provides filtered and regulated 24VDC, up to four (4) Class “B”, two (2) Class “A”, or two (2) Class “B” and one (1) Class “A” Notification Appliance Circuits. With the optional plug-in PS-EXP module the unit supports (8) Class “B” or (4) Class “A” Notification Appliance Circuits. Additionally, an auxiliary power output of 2.5 Amps (disconnected upon AC power loss or an alarm condition) or up to 0.240 A of constant power on the PS-8 and 0.075 A of constant power on the PS-6. The Wheelock Power Supplies can accommodate 7 or 12 AH batteries inside its lockable chassis. Using an external battery cabinet it can charge up to 33 AH batteries (pending UL testing). Two FACP NAC circuits or two “Dry” contact initiating circuits can be connected to the inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. Each output is rated at 3.0 Amps (Class “B”) or (Class “A”) and can be programmed to generate a steady or Code 3 Temporal Horn sound and a strobe output under alarm condition. Total load for the PS-6 and PS-8 NAC circuits must not exceed the power supplies rated output. The Power Suppliesunder non-alarm condition provides independent supervision for Class “A” and Class “B” FACP NAC circuits. In the event of circuit trouble, the FACP will be notified via the POWERPATH steered input (IN1 or IN2). In addition there are two sets of trouble reporting terminals, one used for AC power loss reporting and the other for all troubles. The AC power loss reporting, on the common trouble terminals and on IN1 or IN2, can be delayed for either 30 seconds or 170 minutes. The AC power loss terminals will always report the trouble within 1 second after loss of AC power. PS-6 Approvals • Approvals Include: UL Standard 864, 1481, California State Fire Marshal (CSFM), Factory Mutual (FM) • Compliant with NFPA 72 Inputs • 120VAC, 50/60Hz, 4.25 Amps (PS-6/8) and 5.32 Amps (PS-8) Operating Power in Alarm • 240VAC, 60Hz, 2.42 Amps (PS-6E and 3.22 Amps (PS-8E) ‘ Operating Power in Alarm • 24VDC Battery Backup Connection • Two (2), 12V or 24V NAC Initiating Circuits (8-33V at 5mA) FWR or DC • Two (2) “Dry” Contact initiating Circuits • Accepts two (2) Class “A” or two (2) Class “B” circuit inputs • Built in battery charger for sealed lead acid or gel type batteries Outputs • NAC outputs are 24VDC, 3.0 Amps each, power limited • 8 Amps on PS-8 and 6 Amps on the PS-6 total alarm current ...Features continued on next page UL® PS-8 Notification The PS-6 and PS-8 Power Supplies are UL Listed under UL Standard 864, 9th Edition to be used with any 24 volt Listed Regulated notification appliances. They include the capability to synchronize Wheelock strobes and horns and to silence the horn signal when horn/strobes are operating on two wires. PS-EXP • Capable of four (4), Class “B” circuits • Capable of two (2) Class “A” circuits • Capable of one (1) Class “A” circuit and two (2) Class “B” circuits • Capable of (8) Class “B” or four (4) Class “A” circuits with optional PS-EXP module • Temporal (Code 3), constant voltage output, Wheelock Sync output or True input to output follower mode • Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits • Input and output can be synchronized with “IN>OUT SYNC” mode (DSM, 2nd POWERPATH™ or FACP with synchronization protocol is required) • Audible silence capability • Filtered and electronically regulated output • 2.5 Amp auxiliary power limited output with reset capability. (Removed upon AC loss or alarm. Automatic reset 30 seconds after AC power returns or the alarm condition is over) or 0.075 Amps (PS-6) or 0.240 Amps (PS-8) of auxiliary power limited output which remains on during AC loss or an alarm condition when configured for 24 hour battery backup Supervision • Compatible with 12V or 24V (FWR or DC) FACP • Signaling appliance circuits are supervised and steered to either IN1 or IN2 • 10K Ohm, 1 Watt (Wheelock Model #MPEOL) End of Line Resistor (EOLR) for supervision of all outputs • 37 distinguishable trouble diagnostics • AC loss trouble reported over a separate set of contacts (delay of 1 second) • All troubles are reported over the common trouble contacts (AC loss can have a delay of 30 seconds or 170 minutes) • Automatic switchover to standby battery when AC fails • Thermal and short circuit protection with auto reset • Input and output status LED indicators • AC fail supervision • Battery presence and low battery supervision • Ground Fault Detection, with diagnostics to indicate which circuit fault is on • Latching LED’s for NAC trouble annunciation and Diagnostic trouble LED’s (latching can be disabled) Power • Not Battery Dependent • Automatic switch over to standby batteries when AC fails • Supports sealed lead acid or gel type batteries • Fused battery protection • Thermal and short circuit protection with auto reset • Supports both 7AH or 12AH batteries in the same cabinet POWERPATH™ Operating Modes (refer to Installation Manual): Normal Mode: Provides constant 24 VDC output upon initiation by a voltage to input IN1 or IN2 or by a contact opening on DRY1 or DRY2. The unit returns to standby mode when the input is deactivated. Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock audible and strobe notification appliances. Audibles can also be silenced in this mode while the strobes continue to flash. In>Out Sync Mode: Accepts a synchronization signal on the input to provide a coded output or synchronized output. This signal may come from a FACP, another POWERPATH or a Wheelock DSM synchronization module. Caution: Do not use strobes on coded output circuits. True Input Follower Mode: Accepts a coded signal on the input to provide a coded output with the same timing as the input. The signal may come from a FACP, another POWERPATH or other coded source. Caution: Do not use strobes on coded output circuits. Temporal Mode: Codes the output voltage in a code-3 temporal pattern to drive audible appliances such as horns, bells or chimes. Caution: Do not use strobes on coded output circuits. Specifications and Ordering Information Model Number Order Code Input Voltage/Current Approvals UL CSFM FM PS-6 105530 6 amp, red enclosure X X X PS-6B 100257 6 amp, black enclosure X X X PS-8 105531 8 amp, red enclosure X X X PS-8B 105830 8 amp, black enclosure X X X PS-6EXP 105083 6 amp power supply with preinstalled expansion module X X X PS-8EXP 105084 8 amp power supply with preinstalled expansion module X X X PS-EXP 105534 4 class B or 2 class A expansion module X X X PS-EXP-RETRO 105527 Field upgrade kit for models prior to January 2010#X X X Input Circuit Input Voltage and Current Input voltage Range 8 to 33 VDC Input Current @ 12 VDC 0.005 amps Input Current @ 24 VDC 0.005 amps Output Circuit Output Voltage and Current Four (4) Class B or 24 VDC @ up to 3 amps per curcuit Two (2) Class A or One (1) Class A and Two (2) Class “B” or 8 Class B or 4 Class A (optional PS-EXP module necessary) Continuous duty up to 3 Amps per circuit, up to 4 Amps maximum per panel Standby Current 0.129 Amps Alarm Current 0.129 Amps Primary PS-6 (120 VAC models)105 to 130 VAC, 50/60 Hz @ 4.25 Amps Primary PS-8 (120VAC models)105 to 130 VAC 50/60 Hz @ 5.32 Amps Primary PS-6E (240 VAC models)210 to 260 VAC, 50/60 Hz @ 2.42 Amps Primary PS-8E (240 VAC models)210 to 260 VAC 50/60 Hz @ 3.22 Amps Secondary Power Charging Capacity 32 Amp hours @ 0.750 Amps per hour Enclosure can house up to two 12 AH batteries Aux Output CP Mode PS-6 up to 75 mA PS-8 up to 250 mA MP Mode 2.5A during non alarm Model Dimensions Weight Comments PS-6/PS-6B 17”H x 13”W x 3.5”D 11.5lbs. (Ship) 9.4lbs (Unit)Small profile PS-8/PS-8B 17”H x 15”W x 5.5”D 17.7lbs (Ship) 15.6lbs (Unit)Additional room for modules PS-EXP 4.3”H x 3.7”W x 1”D 1lb. (Ship & Unit)Plugs into main pcb on all models X= Approved *= Pending #=Contact Technical Support for additional inforamation on upgrade options The power supply shall be Wheelock POWERPATH™ Series PS-8, or equivalent. The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70 (NEC), article 760. The power supply shall support a full 8A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a “Dry contact” opening. The units shall be 8 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions. The power supply shall provide four Class “B”, two Class “A”, or two Class “B” and one Class “A” NAC circuit(s). Eight Class “B” or Four Class “A” circuits shall be available with an optional PS-EXP module. The PS-8 unit shall supply up to 240 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class “B” applications or 3 amperes each for Class “A”. The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supply shall provide independent loop supervision for either Class “A” or Class “B” FACP NAC circuits and shall have the capability to “steer” all alarm or trouble conditions to either incoming NAC circuit. The units shall have common trouble terminals. The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.129 Amps max. The power supply shall have the ability to latch trouble LED’s so the circuit in trouble can be identified. The cabinet dimensions shall be 17” H x 15” W x 5.5” D. The power supply shall be Wheelock POWERPATH™ Series PS-6, or equivalent. The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70 (NEC), article 760. The power supply shall support a full 6A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a “Dry contact” opening. The units shall be 6 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions. The power supply shall provide four Class “B”, two Class “A”, or two Class “B” and one Class “A” NAC circuit(s). Eight Class “B” or Four Class “A” circuits shall be available with an optional PS-EXP module. The PS-6 unit shall supply up to 200 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at a maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class “B” applications or 3 amperes each for Class “A”. The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supply shall provide independent loop supervision for either Class “A” or Class “B” FACP NAC circuits and shall have the capability to “steer” all alarm or trouble conditions to either incoming NAC circuit. The units shall have common trouble terminals. The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.130 Amps max. The power supply shall have the ability to latch trouble LED’s so the circuit in trouble can be identified. The cabinet dimensions shall be 17” H x 13” W x 3.5” D. Architects and Engineers Specifications NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accor- dance with Wheelock Inc. standard terms and conditions. WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLA- TION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. S9100 PS-6 & 8 06/11 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 1 YEAR WARRANTY NotificationCooper Notification is NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com Description The Wheelock Series E Low Profile Speakers and Speaker Strobes are designed for high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. The Series E Speaker Strobe models incorporate the Low Current draw Series RSS Strobes. Strobe options for wall mount models include 1575 or Wheelock patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. Series E Speakers and Speaker Strobes provide high audio output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The strobe portion of all Series E Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Series E Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for the Series E Speakers and Speaker Strobes are red, white and nickel plated. Features • Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information • ADA/NFPA/ANSI compliant • Complies with OSHA 29 Part 1910.165 • Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi- Candela models), or 1575cd (Single Candela model) • Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (Multi- candela models) • Strobes produce 1 flash per second over the regulated voltage range • 24 VDC with wide UL “Regulated Voltage” using filtered DC or unfiltered VRMS input voltage • Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol • Field selectable taps for 25 or 70 VRMS operation from 1/8 watt up to 2 watts • High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires SERIES E70 STROBE SERIES E90 SPEAKER Series E70 Speakers and Speaker Strobes THE CITY OF NEW YORK DEPA RTMENT OF BUILDINGS UL® 151-92-ES5391 7125-0785:152 7320-0785:134 (Speaker) SERIES E90 STROBE SERIES E70 SPEAKER Notification Table 1: UL Max Current* E70/E90 Speaker Strobes E70 Strobe Current - Wall Mount E90 Strobe Current - Ceiling Mount 241575W 24MCW 24MCWH 24MCC 24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 16-33 VDC 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 Table 2: E70/E90 UL Reverberant dBA @ 10 Feet** watts 1/8 1/4 1/2 1 2 E Speaker 77 81 83 86 89 E Speaker Strobe 76 80 82 85 88 **dBA ratings are based on testing under UL Standard 1480. * UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their “Regulated Voltage Range”. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • “Regulated Voltage Range” is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology “Listed Voltage Range”. Series PS Power Supplies Series PS Power Supplies EOLR F A C P OUTPUTS 1-4 4-CLASS "B" OR 2-CLASS "A" E E E ST ST ST DSM + OUT 2 +OUT 1 + IN 1 + IN 2 MINUS 1 MINUS 2 + - - + SYNC AUDIBLE STROBE NAC CIRCUIT OUT STROBE NAC CIRCUIT RETURN FA CP E E E E E E F A C P DSM #3Audible NAC Cir . Strobe NAC Cir. DSM #2 DSM #1 Strobe NAC Cir. Strobe NAC Cir. Audible NAC Cir . Audible NAC Cir . E E E E E E Sync Sync Sync + -+ +- - DSM Interconnecting wiring shown. Maximum of twenty (20) Wiring Diagrams# For wiring information on the Wheelock power supplies, please refer to Data Sheet #S9100. SERIES E SPEAKER & STROBE OPERATE INDEPENDENTLY (NON-SYNC OR SYNC) SERIES E SPEAKER STROBES SYNCHRONIZED WITH MULTIPLE DSM MODULES SERIES E SPEAKER STROBE APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS “A” SERIES E SPEAKER STROBE APPLIANCES & RSS STROBES SYNCHRONIZED WITH WHEELOCK POW- ER SUPPLIES Note: Figure shows intercon- nection to strobe through sync module. Speaker portion requires 2 separate conduc- tors to FACP. # For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84905. TO NEXT APPLIANCE OR EOLR FROM PRECEDING APPLIANCE OR VOICE EVACUATION PANEL TO NEXT STROBE OR EOLR FROM PRECEDING STROBE, SYNC MODULE, POWER SUPPLY OR FACP SPEAKERSTROBE +-+ + - - -++ + - - Model Order Code Wall Mount Ceiling Mount Strobe Sync w/ DSM or Wheelock Power Supplies Strobe Candela Model Color RED Model Color White Model Color Nickel Mounting Op- tions Agency Approvals UL MEA CSFM FM BFP E70-24MCW-FR 9022 X -X 15/30/75/110 X --L,O,P,Q,R,U,Y X X X X X E70-24MCW-FW 9023 X -X 15/30/75/110 -X -L,O,P,Q,R,U,Y X X X X X E70-24MCW-FN 3099 X -X 15/30/75/110 --X Q,U X X X X X E70-241575W-FR 7871 X -X 15 (75 on Axis)X --L,O,P,Q,R,U,Y X X -X X E70-241575W-FW 7876 X -X 15 (75 on Axis)-X -L,O,P,Q,R,U,Y X X -X X E70-241575W-FN 3100 X -X 15 (75 on Axis)--X L,O,P,Q,R,U,Y X X -X X E70-R 7866 X X --X --Q,U X X X X X E70-W 7868 X X ---X -Q,U X X X X X E70-N 3108 X X ----X Q,U X X X X X E70-24MCC-FW 0102 X X 115/177 -X -Q,U,V X X X X X E70-24MCWH-FR 3470 X -X 135/185 X --L,O,P,Q,R,U,Y X X X X - E70-24MCWH-FW 3474 X -X 135/185 -X -L,O,P,Q,R,U,Y X X X X - E70-24MCWH-FN 0059 X -X 135/185 --X Q,U X X X X - E90-24MCC-FW 3166 -X X 15/30/75/95 -X -Q,U,V X X X X - E90-24MCC-FR 3165 -X X 15/30/75/95 X --Q,U,V X X X X - E90-24MCC-FN 3185 -X X 15/30/75/95 --X Q,U,V X X X X - E90-W 7869 X X ---X -Q,U,V X X X X X E90-R 7867 X X --X --Q,U,V X X X X X E90-N 3109 X X ----X Q,U,V X X X X X E90-24MCCH-FW 3471 -X X 115/177 -X -Q,U,V X X X X - E90-24MCCH-FR 3481 -X X 115/177 X --Q,U,V X X X X - E90-24MCCH-FN 0062 -X X 115/177 --X Q,U,V X X X X - Specifications and Ordering Information Also comes in NW (no writting). Models available with no writting, may be subject to minimum quantity order. Architects and Engineers Specifications S1610 E70/E90 06/11 The speaker appliances shall be Wheelock Series E Speakers and the speaker strobe appliances shall be Wheelock Series E Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The strobe shall be of low current design. Where Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and strobe speakers shall be white, red, or nickel plate. All speaker and speaker strobe appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY NotificationCooper Notification is NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com Description The Wheelock Series S Speakers and Speaker Strobes are de- signed for high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 8 watts. The Series S Speaker Strobe models incorporate the Low Current draw Series RSS Strobes. Strobe options for ceiling mount models include Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. Series 8 Speakers and Speaker Strobes provide high audio output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The strobe portion of all Series S Speaker Strobes may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or Wheelock PS-24-8MC Power Supplies with Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Series S Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. The Series S, 8” Ceiling Speakers and Speaker Strobes are available in three configurations: S8-70/25 - Dual Voltage, multi-tap speaker S8-24MCC - Speaker strobe with field selectable settings of 15/30/75/95cd S8-24MCCH - Speaker strobe with field selectable candela settings of 115/117cd Features • Approvals include: UL Standard 1971, UL Standard 1480, California State Fire Marshal (CSFM) and MEA (See approvals by model number under Specification and Ordering Information) • ADA/NFPA/ANSI compliant • Complies with OSHA 29 Part 1910.165 • Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (Multi- candela models) • Strobes produce 1 flash per second over the regulated voltage range • 24 VDC with wide UL “Regulated Voltage” using filtered DC or unfiltered VRMS input voltage • Synchronize with Wheelock SM, DSM or Wheelock PS- 12/24-8CP and PS-12/24-8MP Power Supply with built-in sync protocol • Field selectable taps for 25 or 70 VRMS operation from 1/8 watt up to 8 watts • High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires • Frequency Response: 200Hz - 15kHz 400Hz - 4kHz (UL) • Magnet weight: 9.5 oz. • Speaker impedance: 8 ohms • Round metal 12” grille, with white powder coated finish • Compatible with DC circuit supervision Applications: • Use with SP40/2 Multi-Function Audio Supervised System • Provides for audio quality background music SERIES S-24MCC Speaker Strobe SERIES S Speaker THE CITY OF NEW YORK DEPA RTMENT OF BUILDINGS UL® 151-92-ES5391 7320-0785:164 Series S 8” Ceiling Speakers and Speaker Strobes Notification * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes, the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Model Number Order Code Speaker Strobe Strobe 24MCCH Voltage (VRMS) dBA @ 10 Feet (Rated Watts) Regulated Voltage VDC/FWR Voltage Range VDC/RMS Candela Average RMS Current 24MCC 1/8 1/4 1/2 1 2 4 8 15cd 30cd 75cd 95cd 115cd 177cd S8-70/25 0052 25/70 75 78 81 84 87 90 93 --- S8-24MCC 0054 25/70 75 78 81 84 87 90 93 24 16.0-33.0 15/30/75/95 24 VDC 0.045 0.070 0.119 0.159 0.195 0.270 S8-24MCCH 0056 25/70 75 78 81 84 87 90 93 24 16.0-33.0 115/177 UL Max*0.065 0.105 0.189 0.249 0.300 0.420 CBB-8 3314 UL Listed Circular Backbox for 8” Speakers Approvals UL 1480 UL 1971 CSFM MEA S8-70/25 X N/A X X S8-24MCC X X X X S8-24MCCH X X X X CBB-8 X N/A Pending Pending Note: In order to maintain proper UL 1480 listing, the CBB-8 Speaker Back Box (available separately) or other UL approved back box must be installed. Specification and Ordering Information NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their “Regulated Voltage Range”. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • “Regulated Voltage Range” is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology “Listed Voltage Range”. TO NEXT� APPLIANCE� OR EOLR� F�ROM� PRECEDING� APPLIANCE� OR VOICE� EVACUATION� PANEL�TO NEXT� STROBE� OR� EOLR� FROM� PRECEDING� STROBE, SYNC� MODULE,� POWER SUPPLY� OR� FACP� SPEAKER�STROBE� +�-�+� +� -� -� -�+�+� +� -� -� F� A� C� P�DSM #3�Audible NAC Cir�.� Strobe NAC Cir.� DSM #2� DSM #1� Strobe NAC Cir.� Strobe NAC Cir.� Audible NAC Cir�.� Audible NAC Cir�.� S�S� S�S� S�S� Sync� Sync� Sync� +� -�+� +�-� -� DSM Interconnecting wiring shown. Maximum of� twenty (20)� DSM� + OUT 2� +OUT 1� + IN 1� + IN 2� MINUS 1� MINUS 2� +� -� -� +� SYNC� AUDIBLE� STROBE� NAC� CIRCUIT� OUT� STROBE� NAC� CIRCUIT� RETURN� FACP� S�S�S� S�S�S� Series PS-12/24-8MP� Series PS-12/24-8MP� or PS-12/24-8CP� EOLR� F� A� C� P� OUTPUTS� 1-4� 4-CLASS� "B"� OR� 2-CLASS� "A"� S� S� S�RSS� RSS� RSS� Wiring Diagrams# SERIES S SPEAKER & STROBE OPERATE INDEPENDENTLY (NON-SYNC OR SYNC) SERIES S SPEAKER STROBES SYNCHRONIZED WITH MULTIPLE DSM MODULES SERIES S SPEAKER STROBE APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS “A” SERIES S SPEAKER STROBE APPLIANCES & RSS STROBES SYNCHRONIZED WITH PS-24-8MC Note: Figure shows interconnection to strobe through sync module. Speaker portion requires 2 separate conduc- tors to FACP. # For details on using SM or DSM Sync Modules refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84662 for PS-24-8MC power supply. Architects and Engineers Specifications S1100 S 8” 02/08 NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Series S, 8” UL listed ceiling speakers and speaker strobes specifications: The series S8 eight-inch supervised UL Standard 1480 Listed Ceiling speaker shall be mounted to round metal 12” grille, with a white powder coated finish, designed for indoor use. The speaker shall have a dual voltage transformer (25/70V) with jumper selectable 1/8, ¼, ½, 1, 2, 4, 8 wattage taps. The frequency response shall be 200Hz 15kHz, per UL Standard 1480 shall be 400Hz 4kHz. The sensitivity shall be 93 dBA @ 10 feet with 8 watts of source power, 90 dBA @ 10 feet with 4 watts of source power, 87 dBA @ 10 feet with 2 watts of source power, 84 dBA @ 10 feet with 1 watts of source power, 81 dBA @ 10 feet with 1/2 watt of source power, 78 dBA @ 10 feet with 1/4 watt of source power, 75 dBA @ 10 feet with 1/8 watt of source power. The magnet weight shall be 9.5 ounces. The speaker impedance shall be 8 ohms. The Speaker Strobe versions shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The Series RSS Strobe shall be of low current design. The strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/95cd or 115/177cd. When synchronization is required, the appliance shall be compatible with Wheelock’s SM, DSM Sync Modules or Wheelock’s PS-12/24- 8CP and PS-12/24-8MP Power Supply with built-in Patented Wheelock Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY NotificationCooper Notification is NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com FL Location 7565 Commerce Ct. Sarasota, FL 34243 P: 941-487-2300 F: 941-487-2389 VA Location P: 877-459-7726 F: 703-294-6560 Description: THE CITY OF NEW YORK DEPARTMENT OF BUILDINGS UL® 151-92-EE5946 S5391 S2652 7125-0785:131 (ASWP) 7125-0785:146 (ET70WP) 7125-0785:156 (MTWP) 7300-0785:154 (RSSWP) Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Designed for life safety, performance and reliability, Cooper Notification’s Wheelock cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes RSSWP Horn Strobes ASWP Horns AH-24WP, AH-12WP Multitone Horn Strobes MTWP Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of –31°F to 150°F (-35°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper Notification provides the industry’s widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (IOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA* and WFPA* kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. • Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM), Chicago (BFP) and ULC . See agency approvals by model number on page two of this document • Compliance with the following requirements: NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, ADA • Weatherproof with extended temperature range of –40°F to 150°F (-40°C to 66°C)* • Dual Listed strobe models (UL 1638 and UL 1971) • Industry’s highest strobe candela options • Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol • Models with field selectable tone, dBA and candela settings • Wall or ceiling mounting options • Surface of semi-flush mounting • IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal Features: All models may be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. The series RSSWP, ASWP, AH-24WP, MTWP-2475W, and MT-12/24 have UL / ULC approval down to -40°F. The ET-1010 and ET70WP have UL approval down to -40°F. The AH-12WP has UL approval down to -31°F. Notification * NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. • All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475W-FW White 3034 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCWH-FW White 5165 Audible Strobe ASWP-2475W-FR Red 9012 ASWP-24MCWH-FR Red 5137 ASWP-24MCWH-FW White 5140 Multi-tone Strobe MTWP-2475W-FR Red 8420 MTWP-2475W-FW White 3112 MTWP-24MCWH-FR Red 5132 MTWP-24MCWH-FW White 5134 Speaker Strobe ET70WP-2475W-FR Red 9077 ET70WP-2475W-FW White 3179 ET70WP-24185W-FR Red 4885 ET70WP-24185W-FW ET70WP-24135W-FR White Red 4891 4872ET70WP-24135W-FW White 4875 UL Max. Current AH 24 VDC 12 VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 UL Max. Current (Audible) MTWP/MT 24 VDC MT 12 VDC dBA HI STD HI STD Horn 0.108 0.044 0.177 0.034 Bell 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 Code 3 Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Hi/Lo 0.057 0.025 0.114 0.026 Strobe Order Code RSSWP-2475C-FR Red 4338 RSSWP-2475C-FW White 4446 RSSWP-24MCCH-FR Red 5167 RSSWP-24MCCH-FW White 5187 Audible Strobe ASWP-2475C-FR Red 4251 ASWP-2475C-FW White 4502 ASWP-24MCCH-FR Red 5149 ASWP-24MCCH-FW White 5157 Multi-tone Strobe MTWP-2475C-FR Red 4457 MTWP-2475C-FW White 4478 MTWP-24MCCH-FR Red 5102 MTWP-24MCCH-FW White 5122 Speaker Strobe ET70WP-2475C-FR Red 4452 ET70WP-2475C-FW White 4454 ET70WP-24177C-FR Red 4845 ET70WP-24177C-FW ET70WP-24115C-FR White Red 4859 4550ET70WP-24115C-FW White 4732 Audible Order Code AH-24WP-R Red 7416 AH-12WP-R Red 7415 Horn MT-12/24-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 UL Reverberant dBA @ 10 Feet Watts 1/8 1/4 1/2 1 2 4 8 ET-1010 77 80 83 86 87 92 94 ET70WP 78 81 84 87 90 93 95 RSSWP MTWP MTWP ET70WPASWP RSSWP MT ET-1010ASWPET70WP AH Wall Mount Ceiling Mount Wall or Ceiling Mount Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X - RSSWP-24MCWH X -X -- RSSWP-24MCCH X -X -- Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X -X -- ASWP-MCCH X -X -- Multitone Strobe MTWP-2475 X X X X - MTWP-MCWH X -X -- MTWP-MCCH X -X -- Horns/Audibles AH-24WP X X X X X AH-12WP X X X X X MT-12/24 X X X X X Speaker Strobe ET70WP-2475 X -X X - ET70WP-185 X -X X - ET70WP-177 X -X X - ET70WP-115 X -X X - ET70WP-135 X -X X - Candela Ratings Series UL 1971 UL 1638 @ 77°F UL 1638 @ -40°F RSS, ET70WP and MTWP UL Max Current (Strobe Only) ASWP High Med Low 2475W 30**180 115 0.138 0.168 0.155 0.150 2475C 15 180 115 0.138 0.168 0.155 0.150 MCWH 135 135 56 0.300 0.355 0.340 0.335 185 185 77 0.420 0.480 0.465 0.460 MCCH 115 115 47 0.300 0.355 0.340 0.335 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 24177 177 177 73 0.420 **Wall mount rating only NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc. dba Cooper Notification standard terms and conditions. Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options WFP WFPA IOB WPSBB WPBB WBB Gasket Kit Order Code WP-KIT 4486 Flush Plates WFPA-R Red 4698 WFPA-W White 4701 WFP-R Red 4696 WFP-W White 4697 Backboxes IOB-R*Red 5046 IOB-W*White 5047 WPSBB-R*Red 9751 WPSBB-W*White 3033 WPBB-R*Red 9014 WPBB-W*White 4692 WBB-R Red 2959 WBB-W White 2960 FA CP NAC #1 NAC #2 Sync Module or PS Power Supply Strobe Circuit Audible Circuit MTWP DSM + OUT 2 +OUT 1 + IN 1 + IN 2 MINUS 1 MINUS 2 + - - + SYNC AUDIBLE STROBE NAC CIRCUIT OUT STROBE NAC CIRCUIT RETURN FA CP RSSWP ST RSS ST ASWP ASWP TO NEXT APPLIANCE OR EOLR FROM PRECEDING APPLIANCE OR FA CP +- STROBE AUDIBLE +- RED BLACK + -- + SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. +- +- +- FROM PRECEDING APPLIANCE OR FA CP TO NEXT APPLIANCE OR EOLR SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12/24 APPLIANCES SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED W/ DSM MODULE SINGLE CLASS “A” NAC CIRCUIT SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP Note: Strobe circuit requires constant voltage. Wiring Diagrams Mounting Accessories Mounting Options:Backboxes, Plates, Gasket Kits Surface Mount Flush MountExposed Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes IOB IOB + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA AHWP Horns WBB -WFP ET-1010 Speakers WBB -WFP MTWP Multitone Horn Strobes IOB IOB + WP-KIT WFP Multitone Horn IOB IOB + WP-KIT WFP *IOB, WPSBB and WPBB models include weep holes and plug in the event that moisture may have entered the appliance ARCHITECTS AND ENGINEERS SPECIFICATIONS S9004 WP 11/12 General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of –40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock IOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock’s WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY NotificationCooper Notification is NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com Description The Wheelock E70H Wall and E90H Ceiling Speakers and Speaker Strobes are designed for high fidelity sound output for indoor applications. With the widest frequency response range (300 to 8000 Hz) in the industry, the EH features leading intelligibility with crisp, clear voice messages and tone signaling, ideal for emergency communications, mass notification, voice evacuation and fire alarm. Providing a sleek aesthetic appearance, the Wheelock Series EH High Fidelity Speakers and Speaker Strobes feature dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. For visible signaling to meet the hearing impaired, the EH Speaker Strobe models incorporate the Low Current draw RSS Strobes. Strobe options for wall mount models include 1575 or Wheelock patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The strobe portion of all EH Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy The EH Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired) and Standard 1480 (Speaker Appliances), and ULC listed under CAN/ULC-S526 (Visual- audible Signal Appliances, Fire Alarm) and under CAN/ULC-S541 (Speakers, Fire Alarm). All inputs employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for the EH Speakers and Speaker Strobes are red and white Wheelock E70H & E90H High Fidelity Speakers & Speaker Strobes Technical Data TD450018EN Effective January 2016 Supersedes January 2015 2 Technical Data TD450018EN Effective January 2016 Wheelock E70H & E90H High Fidelity Speakers & Speaker Strobes EATON www.eaton.com Features • High Fidelity Sound Output • Efficient design for high intelligibility at minimum wattage across a frequency range of 300 to 8000 HZ • 6 Field Selectable Settings • Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) or 1575cd (Single Candela model) • Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (Multi-candela models) • Field Selectable Taps • 1/8 watt up to 2 watts • 25 or 70 VRMS operation • Easy-to-Install • Low profile design incorporates speaker mounting plate for faster and easier installation • Built - in level adjustment feature and an aesthetic two (2) screw grille cover. • Quick installation with IN/OUT screw terminals using #12 to #18 AWG wires • 4” square backbox prevents wire damage • Strobe Synchronization Components • Meet synchronizing standards with Wheelock’s DSM Sync Modules, PS Power Supplies or SAFEPATH products • Compliance • UL 1971, UL 1480, ULC-S526, ULC-S541 • Low frequency requirements of UL 464 (520 Hz) to meet NFPA’s 520 Hz tone requirements for sleeping areas • California State Fire Marshal (CSFM) • ADA/NFPA/ANSI/OSHA • FCC Part 15, ICES Note:N All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.EATON.COM/MASSNOTIFICATION OR CONTACT EATON FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Drawings Figure 1. E70H (top) and E90H (bottom) Speakers - Front & Side Views Figure 2. E70H (top) and E90H (bottom) Speaker Strobes - Front & Side Views General Notes • Strobes are designed to flash at 1 flash per second minimum over their “Regulated Voltage Range.” Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. 3 Technical Data TD450018EN Effective January 2016 Wheelock E70H & E90H High Fidelity Speakers & Speaker Strobes EATON www.eaton.com Table1: Maximum RMS Current - Series E70H Table 2: Maximum RMS Current - Series E90H 24MCW/24MCC 24MCWH/24MCCH 241575W Model Regulated Voltage Range VDC 15 30 75 95 110 115 135 177 185 15/75 E70H 16.0-33.0 0.060 0.092 0.165 0.220 0.300 0.420 0.090 E90H 16.0-33.0 0.065 0.105 0.189 0.249 0.300 0.420 Table 2. UL Listed Models and Ratings UL Reverberant dBA at 10 Feet b Model 1/8 watts c 1/4 watts 1/2 watts 1 watts 2 watts E70H Speaker E90H SpeakerE70H Speaker StrobeE90H Speaker Strobe 72727174 75757577 78787880 81818182 83828385 Table 3. Specification & Ordering Information Model Order #Strobe Candela Red White Lettering Wall Ceiling MountingOptions Sync w/ DSM or Wheelock Power Supplies Speakers E70H-RE70H-W E90H-RE90H-W 98659866 98759876 X X X X No LetteringNo Lettering No Lettering No Lettering X X XX P, QP, QP, QP, Q Speaker Strobes E70H-24MCW-FRE70H-24MCW-FW E70H-24MCWH-FR E70H-24MCWH-FWE90H-24MCC-FRE90H-24MCC-FWE90H-24MCCH-FRE90H-24MCCH-FW 01830184 018501860191019201940193 15/30/75/110 15/30/75/110 135/185135/18515/30/75/9515/30/75/95115/177115/177 X X X X X X X X FIREFIRE FIRE FIREFIREFIRE FIREFIRE XXXX XXXX P, QP, QP, Q P, QP, QP, QP, QP, Q XXXXXXXX Table 4. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Weight E70H Speaker: 1.7 lbs (0.77 kg); E70H Speaker Strobe 1.8 lbs (0.82kg); E90H Speaker: 1.5 lbs (0.68 kg); E90H Speaker Strobe 1.6 lbs (0.73 kg) Lens (Material type)GE Lexan 943A Dimensions E70H Speaker: 5.13” W x 5.13” H x 0.43”D; E70H Speaker Strobe: 5.13” W x 5.13” H x 2.56”D; E90H Speaker: 7.27” Diameter x 0.43” D; E90H Speaker Strobe: 7.327 Diameter x 2.68” D Operating Temperature Indoor: 33.8°F to 120.2°F (0°C to 49°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only)4”square backbox with extension ring prevents wire damage; SBB for surface mount of E70H Wire Connections #12 through #18 AWG Power & General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971, ULC S526 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock’s DSM Sync Modules, Power Supplies or SAFEPATH products, using Wheelock patented sync protocol Frequency Range 300 Hz to 8000 Hz a RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. b dBA ratings are based on testing under UL Standard 1480. c 1/8 watt tap is for private mode only. Table 1. Maximum RMS Current Eaton is a registered trademark. All other trademarks are property of their respective owners. Wheelock E70H & E90H High Fidelity Speakers & Speaker Strobes Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 www.eaton.com/massnotification © 2016 Eaton All Rights Reserved Printed in USA Publication No. TD450018EN January 2016 Technical Data TD450018EN Effective January 2016 The speaker appliances shall be Wheelock Series E70H or E90H High Fidelity Speakers and Speaker Strobe appliances or approved equals. The speakers shall be UL Listed under UL 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL 1971 for Emergency Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class A. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 300 to 8000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range. The strobe shall be of low current design. Where Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. Models with 1575 candela shall also be offered for wall-mount applications. When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series EH speakers and strobe speakers shall be red or white. All speaker and speaker strobe appliances shall be backward compatible. The speaker shall be listed to the low frequency requirements of UL 464 (520 Hz) to meet NFPA’s 520 Hz tone requirements for sleeping areas. UL 1971, UL 1480, ULC-S526, ULC-S541, CSFM, FCC. Note:N Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Architects and Engineers Specifications The information and specifications described herein are subject to error or omission and to change without notice. Paige provides the information and specifications herein on an “AS IS” basis, with no representations or warranties, whether express, statutory or implied. In no event will Paige be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Paige has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. G-WM74122162WH Rev 1.7 10/15/10-Q 74122162WH spec 2 CONDUCTOR 12 AWG STRANDED + 2 CONDUCTOR 16 AWG STRANDED SIAMESE TYPE CL3/FPL 1.0 SCOPE: 1.1 Two element composite cable, (2) conductors 12 AWG unshielded, overall color-coded polypropylene insulation; (2) conductors 16AWG unshielded, overall color-coded polypropylene insulation, overall cabled and jacketed with PVC in a siamese construction for data communications and security applications. Manufactured in the USA and listed (UL) CL3/FPL 75°. UL Standards 13 & 1424 NEC Articles 725 & 760 UL 1581 CSFM 2.0 CONSTRUCTION: 2.1 ELEMENT 1: 12/2 CONDUCTOR: 2.1.1 Material: Bare Copper 2.1.2 Size: 12 AWG 2.1.3 Construction: 19 Strand 2.2 INSULATION: 2.2.1 Material: Polypropylene (PP) 2.2.2 Wall Thickness: .010” nom. 2.2.3 O.D.: .115” nom 2.2.4 Color code: 1-Black, 2-Red 2.3 ASSEMBLY: 2.3.1 Cabled conductors 2.4 ELEMENT 2: 16/2 CONDUCTOR: 2.4.1 Material: Bare Copper 2.4.2 Size: 16 AWG 2.4.3 Construction: 7 Strand 2.5 INSULATION: 2.5.1 Material: Polypropylene (PP) 2.5.2 Wall Thickness: .010” nom. 2.5.3 O.D.: .070” nom 2.5.4 Color code: 1-Yellow, 2-Green 2.6 ASSEMBLY: 2.6.1 Cabled conductors 2.7 OVERALL JACKET: 2.7.1 Material: PVC 2.7.2 Wall Thickness: .020” nom. 2.7.3 OD: TBD 2.7.4 Color: White 2.7.5 RIPCORD UNDER JACKET OF EACH ELEMENT 2.7.6 Markings: PAIGE 74122162WH E191596 12/2C+16/2C C(UL) CL3/FPL “ROHS COMPLIANT” DESCENDING FOOTAGE MARKINGS EVERY TWO FEET 2.8 ELECTRICAL PROPERTIES 2.8.1 Temperature: -20˚C to 60˚C 2.8.2 Voltage: 300 Volt 2.8.3 DC Resistance: 12 AWG: 1.6 Ohms/M’ @ 20˚C 16 AWG: 4.1 Ohms/M’ @ 20˚C 2.9 PUT-UPS 2.9.1 750’ 1 Pac 2 Box 99H001G 2.9.2 Weight: 60 lbs / 750’ 908-687-7810, 800-327-2443, Fax: 908-687-8860 www.paigeelectric.com The information and specifications described herein are subject to error or omission and to change without notice. Paige provides the information and specifications herein on an “AS IS” basis, with no representations or warranties, whether express, statutory or implied. In no event will Paige be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Paige has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. Spec454910AGR Rev 1.1 112706Q 454910AGR spec 3 PAIRS 18 AWG STRANDED INDIVIDUALLY SHIELDED TYPE CMR/FPLR 1.0 SCOPE: 2.3 INDIVIDUALLY SHIELDS: 1.1 This cable consists of 3 pairs 18 AWG 2.3.1 Material: Aluminum Polyester stranded bare copper; color 2.3.2 Coverage: 100% coded PVC insulation; each pair with aluminum polyester shield and drain 2.4 DRAIN: wire; overall gray PVC jacket. 2.4.1 Material: Tinned Copper Type CMR/FPLR 2.4.2 Size: 24 AWG UL Standards 444 & 1424 2.4.3 Construction: 7 x 32 NEC Articles 760 & 800 UL 1666 Riser 2.5 JACKET: 2.5.1 Material: PVC 2.0 CONSTRUCTION: 2.5.2 Wall Thickness: .025” 2.1 CONDUCTOR: 2.5.3 OD: .307” nom. 2.1.1 Material: Bare Copper 2.5.4 Color: Gray 2.1.2 Size: 18 AWG 2.5.5 Ripcord under jacket 2.1.3 Construction: 7 x 26 2.5.6 Markings: PAIGE LoVo #454910AGR 18 AWG 3/PR ISP (UL) TYPE CMR/FPLR 2.2 INSULATION: E191596 2.2.1 Material: PVC 2.2.2 Wall Thickness: .010” nom. 2.6 ELECTRICAL PROPERTIES 2.2.3 Color code: 2.6.1 Temperature: -20˚C to 75˚C Pair 1: 2.6.2 Voltage: 300 Volt 1-Black 2.6.3 Capacitance: 45 pF/ft nom 2-Red 2.6.4 Impedance: 41 Ohms Pair 2: 2.6.5 Velocity of Propagation: 55% 1-Black 2.6.6 DC Resistance: 6.92 Ohms/M’ @ 20˚C 2-White Pair 3: 2.7 PUT-UPS: 1-Black 2.7.1 500’ or 1000’ Box 2-Green 2.7.2 Weight: 79 lbs / 1000’ 908-687-7810, 800-327-2443, Fax: 908-687-8860 www.paigeelectric.com THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. CERTIFICATE OF COMPLIANCE WAL-MART STORES INC (SUPPLIER DIRECT) 702 SW 8TH ST BENTONVILLE AR 72716 WAL-MART STORES INC (SUPPLIER DIRECT) 702 SW 8TH ST BENTONVILLE AR 72716 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S3152-7 S25115-1 ***THIS CERTIFICATE EXPIRES ON 31-MAR-2019*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station Proprietary Fire Alarm Monitoring Stations UUFX UUKA BENTONVILLE, AR Alarm Service Company: (974889-001) Service Center: (974889-001) Listed Service From: Applicant ID No: Service Center No: Expires: 974889-001 1 31-MAR-2019