Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LOAD SHORT FORM - 19-00477 - 2228 Summerfield Ln - New SFR
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Load Short Form 2/7/19Date:Entire House By: DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information KARTCHNER HOMESFor: Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1476Design TD (°F) H-Daily range 5050Inside humidity (%) -3162Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMSS960603BN Cond GSX130301B AHRI ref 7365096 Coil CAPF3030D6D AHRI ref 4355516 Efficiency 96.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh60000 Sensible cooling Btuh19880 Heating output Btuh58000 Latent cooling Btuh8520 Temperature rise °F66 Total cooling Btuh28400 Actual air flow cfm950 Actual air flow cfm950 Air flow factor cfm/Btuh0.029 Air flow factor cfm/Btuh0.125 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room2 168 2289 371 66 46 Room3 55 450 53 13 7 Room5 72 666 72 19 9 Room6 405 4672 1166 135 146 Room7 646 13909 3403 403 425 Room10 156 2682 482 78 60 Room11 182 2721 492 79 61 Room12 40 0 0 0 0 Room13 226 3297 1304 96 163 Room14 80 1430 169 41 21 Room15 70 674 96 20 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W Entire House d 2100 32790 7608 950 950 Other equip loads 4012 739 Equip. @ 0.94 RSM 7846 Latent cooling 0 TOTALS 2100 36802 7846 950 950 2019-Aug-20 11:31:32 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Building Analysis 2/7/19Date:Entire House By: DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information KARTCHNER HOMESFor: Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 39.0143414.8Walls 11.2412224.0Glazing 1.867811.4Doors 8.731921.5Ceilings 10.137001.81.8Floors 18.467572.4Infiltration 00Ducts 00Piping 00Humidification 10.94012Ventilation0Adjustments 100.036802Total Cooling Walls Glazing Other Ceilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 13.311060.4Walls 44.6372521.7Glazing 2.01652.8Doors 21.117640.8Ceilings 2.72250.1Floors 7.56220.2Infiltration 00Ducts 8.9739Ventilation 00Internal gains 00Blower 0Adjustments 100.08347Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 45 Btuh/ft²-°F Data entries checked. 2019-Aug-20 11:31:32 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Component Constructions 2/7/19Date:Entire House By: DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information KARTCHNER HOMESFor: Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B19-0wc-4: Bg wall, heavy dry or light damp soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh 120.095844.3919.00.047133n 220.0910704.4419.00.047241e 230.1010534.5019.00.047234s 210.109324.5019.00.047207w 780.1036394.4619.00.047815all Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1690.4717614.9422.00.065357n 3350.4734934.9422.00.065707e 1780.4718524.9422.00.065375s 3450.4735964.9422.00.065728w 10280.47107034.9422.00.0652167all Partitions (none) Windows 61C: 61C; NFRC rated (SHGC=0.32); 6.67 ft head ht 0.30020n 20610.345622.80 54910.6126524.300.32052n 68334.145622.800.30020e 86134.460824.300.32025e 56618.973024.300.32030s 86134.460824.300.32025w 372521.7412224.000.320172all Doors metal: Door, mtl pur core type 492.7820011.410.50.15018n 582.7823911.410.50.15021e 582.7823911.410.50.15021s 1652.7867811.410.50.15060all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 17640.8431921.5250.00.0202100 Floors 2019-Aug-20 11:31:32 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W 19A-38bscp: Part floor, carpet flr fnsh, r-38 ins, frm flr, 12" thkns 12241.8938.00.029646 2250.35 21A-24c: Bg floor, heavy dry or light damp soil, 6' depth, carpet flr fnsh 013301.9000.025700 0 21A-32c: Bg floor, heavy dry or light damp soil, 4' depth, carpet flr fnsh 011461.5200.020754 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Project Summary 2/7/19Date:Entire House By: DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information KARTCHNER HOMESFor:Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F70 Inside db °F75 Design TD °F76 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh32790 Structure Btuh7608 Ducts Btuh0 Ducts Btuh0Central vent (57 cfm)4012 Btuh Central vent (57 cfm)Btuh739 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh36802 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh7846 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh-865 Ducts Btuh0Central vent (57 cfm)Btuh-1027 CoolingHeating Outside air21002100Area (ft²)Equipment latent load Btuh0 1803818038Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh7846 Equiv. AVF (cfm)4896 Req. total capacity at 0.70 SHR ton0.9 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg.Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMSS960603BN Cond GSX130301BAHRI ref 7365096 Coil CAPF3030D6D AHRI ref 4355516Efficiency96.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh60000 Sensible cooling Btuh19880Heating output Btuh58000 Latent cooling Btuh8520 Temperature rise °F66 Total cooling Btuh28400Actual air flow cfm950 Actual air flow cfm950 Air flow factor cfm/Btuh0.029 Air flow factor cfm/Btuh0.125Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 2019-Aug-20 11:31:32 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:AED Assessment 2/7/19Date:Entire House By: DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information KARTCHNER HOMESFor: Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 18.9%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Right-J® W or ksheet 2/7/19Date:Entire House By:DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Entire House Room2 2 Exposed wall 319.0 ft 26.0 ft 3 Room height 9.9 dft 9.0 heat/coolft 4 Room dimensions ft14.0x12.0 5 Room area 2100.0 f t²168.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.394.39 0.090.09 153 133 584 12 108 88 381 7 .GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 20 0 456 206 20 0 456 206 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 426 357 1761 169 0 0 0 0 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 52 0 1265 549 0 0 0 0 1 1 DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 18 18 200 49 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.444.44 0.090.09 261 241 1070 22 126 126 567 13 GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 20 0 456 683 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 753 707 3493 335 0 0 0 0 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 25 0 608 861 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 21 21 239 58 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.504.50 0.100.10 234 234 1053 23 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 426 375 1852 178 0 0 0 0 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 30 0 730 566 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 21 21 239 58 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.504.50 0.100.10 207 207 932 21 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 753 728 3596 345 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 25 0 608 861 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 2100 2100 3192 1764 168 168 255 141 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 646 646 1224 225 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 700 700 1330 0 168 168 319 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 754 754 1146 0 0 0 0 0 6 c) AED excursion 0 -24 Envelope loss/gain 26033 6985 1979 342 12 a)Infiltration 6757 622 310 29 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)32790 7608 2289 371 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 32790 7608 2289 371 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 32790 7608 2289 371 Air required (cfm)Air required (cfm)950 950 66 46 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Right-J® W or ksheet 2/7/19Date:Entire House By:DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room3 Room5 2 Exposed wall 5.0 ft 8.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.0x5.0 ft8.0x9.0 5 Room area 55.0 f t²72.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.394.39 0.090.09 45 45 203 4 0 0 0 0 .GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 1 1 DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.444.44 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.504.50 0.100.10 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.504.50 0.100.10 0 0 0 0 72 72 324 7 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 55 55 84 46 72 72 109 60 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 55 55 104 0 72 72 137 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -3 -5 Envelope loss/gain 391 47 570 63 12 a)Infiltration 60 5 95 9 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)450 53 666 72 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 450 53 666 72 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 450 53 666 72 Air required (cfm)Air required (cfm)13 7 19 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 3...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Right-J® W or ksheet 2/7/19Date:Entire House By:DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room6 Room7 2 Exposed wall 56.0 ft 114.0 ft 3 Room height 9.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft405.0x1.0 ft646.0x1.0 5 Room area 405.0 f t²646.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.394.39 0.090.09 0 0 0 0 0 0 0 0 .GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 192 163 803 77 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 12 0 292 127 1 1 DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 18 18 200 49 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.444.44 0.090.09 135 115 503 10 0 0 0 0 GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 20 0 456 683 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 492 471 2327 223 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 21 21 239 58 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.504.50 0.100.10 234 234 1053 23 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 192 141 697 67 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 30 0 730 566 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 21 21 239 58 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.504.50 0.100.10 135 135 608 13 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 492 467 2307 222 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 25 0 608 861 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 405 405 616 340 646 646 982 543 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 646 646 1224 225 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 405 405 769 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 35 27 Envelope loss/gain 4005 1105 10647 3103 12 a)Infiltration 668 62 3263 301 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4672 1166 13909 3403 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4672 1166 13909 3403 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 4672 1166 13909 3403 Air required (cfm)Air required (cfm)135 146 403 425 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 4...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Right-J® W or ksheet 2/7/19Date:Entire House By:DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room10 Room11 2 Exposed wall 25.0 ft 27.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft12.0x13.0 ft14.0x13.0 5 Room area 156.0 f t²182.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.394.39 0.090.09 0 0 0 0 0 0 0 0 .GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 117 97 479 46 117 97 479 46 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 20 0 486 211 20 0 486 211 1 1 DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.444.44 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 108 108 534 51 0 0 0 0 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.504.50 0.100.10 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.504.50 0.100.10 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 126 126 622 60 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 156 156 237 131 182 182 277 153 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 156 156 237 0 182 182 277 0 6 c) AED excursion -30 -32 Envelope loss/gain 1973 410 2141 438 12 a)Infiltration 537 49 580 53 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2510 459 2721 492 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 172 23 0 0 14 Subtotal 2682 482 2721 492 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2682 482 2721 492 Air required (cfm)Air required (cfm)78 60 79 61 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 5...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Right-J® W or ksheet 2/7/19Date:Entire House By:DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room12 Room13 2 Exposed wall 5.0 ft 28.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.0x8.0 ft226.0x1.0 5 Room area 40.0 f t²226.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.394.39 0.090.09 0 0 0 0 0 0 0 0 .GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 1 1 DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.444.44 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 45 45 222 21 108 83 410 39 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 25 0 608 861 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.504.50 0.100.10 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 144 144 711 68 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.504.50 0.100.10 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 40 40 61 34 226 226 344 190 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 40 40 61 0 226 226 344 0 6 c) AED excursion -4 52 Envelope loss/gain 344 51 2416 1211 12 a)Infiltration 107 10 601 55 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)451 61 3017 1266 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -451 -61 279 38 14 Subtotal 0 0 3297 1304 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 3297 1304 Air required (cfm)Air required (cfm)0 0 96 163 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-20 11:31:32Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 6...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Right-J® W or ksheet 2/7/19Date:Entire House By:DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room14 Room15 2 Exposed wall 18.0 ft 7.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft8.0x10.0 ft7.0x10.0 5 Room area 80.0 f t²70.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.394.39 0.090.09 0 0 0 0 0 0 0 0 .GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 1 1 DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.444.44 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.504.50 0.100.10 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 90 90 445 43 0 0 0 0 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.504.50 0.100.10 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 72 72 356 34 63 63 311 30 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 80 80 122 67 70 70 106 59 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 80 80 122 0 70 70 106 0 6 c) AED excursion -11 -6 Envelope loss/gain 1043 133 524 82 12 a)Infiltration 386 36 150 14 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1430 169 674 96 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1430 169 674 96 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1430 169 674 96 Air required (cfm)Air required (cfm)41 21 20 12 Job #: SF7B11 Performed for: KARTCHNER HOMES Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and Electric P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 73 Page 1 Righ t-S uite ® Un iv ers a l 2 0 18 18.0.19 RSU20477 2019-Aug-20 11:31:50 ...software\SF7B11. DAVENPORT A.rup N Upper Room10 Room11 Room12 Room13 Room14 Room15 163 cfm 41 cfm 81 cfm 81 cfm 78 cfm 79 cfm 20 cfm 200 cfm 79 cfm Job #: SF7B11 Performed for: KARTCHNER HOMES Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and Electric P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 73 Page 2 Righ t-S uite ® Un iv er s a l 2 0 18 18.0.19 RSU20477 2019-Aug-20 11:31:50 ...software\SF7B11. DAVENPORT A.rup N Main Room7 85 cfm 85 cfm 85 cfm 85 cfm 85 cfm Job #: SF7B11 Performed for: KARTCHNER HOMES Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and Electric P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 73 Page 3 Righ t-S uite ® Un iv ers a l 2 0 18 18.0.19 RSU20477 2019-Aug-20 11:31:50 ...software\SF7B11. DAVENPORT A.rup N Lower Room2 Room3 Room4 Room5 Room6 33 cfm 73 cfm 33 cfm 13 cfm 19 cfm 73 cfm 576 cfm 2-14x3.25 12 x 8 6 " 6 " 6 " 6 " 20 x 8 12 x 8 6 " 6 " 6 "6 " 6 " 6 " 6 " 6 " 6 " 20 x 8 5-14x3.25 20 x 8 6 " 20 x 8 2-14x3.25 12 x 8 2019-Aug-20 11:31:33 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W SF7B11Job:Duct System Summary 2/7/19Date:Entire House By: DAVENPORT APlan:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information KARTCHNER HOMESFor: Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.39in H2O0.39 Available static pressure in H2O0.31in H2O0.31 Supply / return available pressure 0.151 / 0.159 in H2O in H2O0.151 / 0.159 Lowest friction rate in/100ft0.055in/100ft0.055 Actual air flow cfm950cfm950 Total effective length (TEL)ft563 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk 00ShMt0x0006078482hRoom10 st11265.08.5ShMt0x06.00.05561792721hRoom11 st7165.036.6ShMt0x06.00.0758148652cRoom13-B st7205.043.3ShMt0x06.00.0618148652cRoom13-C st7175.026.3ShMt0x06.00.07521411430hRoom14-A st7205.023.0ShMt0x06.00.0661220674hRoom15 00ShMt0x0002333186hRoom2 st7175.032.3ShMt0x06.00.07323331144hRoom2-A st2190.013.0ShMt0x06.00.074713450hRoom3 st1175.012.0ShMt0x06.00.081919666hRoom5 st7205.040.5ShMt0x06.00.0617368583cRoom6 st7160.034.0ShMt0x06.00.0787368583cRoom6-A st7170.034.8ShMt0x06.00.0748581681cRoom7 st7150.039.8ShMt0x06.00.0798581681cRoom7-A st2190.06.0ShMt0x06.00.0778581681cRoom7-B 00ShMt0x0008581681cRoom7-C st7150.038.5ShMt0x06.00.0808581681cRoom7-D Bold/italic values have been manually overridden 2019-Aug-20 11:31:33 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...ocuments\wrightsoftware\SF7B11. DAVENPORT A.rup Calc = MJ8 Front Door faces: W Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 586 629 0.061 566 12.8 20x8 ShtMetl st2 Peak AVF 172 153 0.055 259 8.1 12x8 ShtMetl st11 Peak AVF 79 61 0.055 118 6.0 12x8 ShtMetl st2 st7 Peak AVF 567 620 0.061 558 12.7 20x8 ShtMetl st1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb2 0x 2000 166 172.0 0.093 316 7.7 2-3.25x14 2-10x18 SJSp rt2 rb4 0x 960 163 186.0 0.086 258 7.2 2-3.25x14 2-10x18 SJSp rt2 rb1 0x 5760 560 289.0 0.055 365 12.6 5-3.25x14 5-10x46 SJSp rt2 rb3 0x 790 61 0 0 249 0 3.25x14 10x9 SJSp Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 871 889 0.055 800 13.9 20x8 ShtMetl rt2 Peak AVF 871 889 0.055 800 13.9 20x8 ShtMetl rt1