HomeMy WebLinkAboutPLAN P2 WASTE AND VENT - 19-00401 - Pizza Hut - Tenant RemodelEV
A
P
O
R
A
T
O
R
EV
A
P
O
R
A
T
O
R
3
EX
I
S
T
I
N
G
GR
E
A
S
E
EX
I
S
T
I
N
G
GR
E
A
S
E
EX
I
S
T
I
N
G
SA
N
I
T
A
R
Y
EX
I
S
T
I
N
G
SA
N
I
T
A
R
Y
3
3"GW
4"SW4"SW
3"GW
3"SW
3"GW
2"V 2"V
2"V2"V2"V
2"V
2"V 2"V
2"
V
2"
V
2"
V
2"
V
2"
V
FS 003
S1 004 6 FS 002
DW 001 7
WC2 001
WCO 003
FD 003
1
LV 001
S3 004
S3 004
S3 004
FD 003 1
FD 003 1
FD 003
1
FD 003
1
FD 003
1
S5 003
RTU
2
RTU
1
RTU
3
4
5
4
5
4
1"CD
1"
C
D
1"CD 1"CD
1"CD
8
8
8
9
9
9
9
WCO 003
WCO 003
WCO 003
WCO 003
4"VTR
2
9
3"GW
EX
I
S
T
I
N
G
G
R
E
A
S
E
EX
I
S
T
I
N
G
SA
N
I
T
A
R
Y
EX
I
S
T
I
N
G
GR
E
A
S
E
EX
I
S
T
I
N
G
SA
N
I
T
A
R
Y
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"
V
2"V
2"V
2"V
2"V
2"V
2"V
FD 003
FD 003
FD 003
FD 003
FD 003
FD 003
FS 003
S1 004
FS 002
DW 001
S3 004
S3 004
S3 004
S5 003
WC2 001
LV 001
3"GW
3"SW
3"GW
3"GW
4"SW
4"SW
2"
S
W
4"SW
2"SW
3"SW
3"SW
2"SW
4"GW
4"GW
2"SW
3"GW
3"GW
4"VTR
WCO 003
WCO 003
WCO 003
WCO 003
WCO 003
3"GW
SHEET NUMBER
RE
V
I
S
I
O
N
S
:
DA
T
E
:
JO
B
N
O
:
DR
A
W
N
:
CH
E
C
K
E
D
:
AC
G
#
:
06
/
2
0
/
1
9
21
7
5
AA
,
K
K
,
S
O
AR
,
C
F
19
2
0
1
9
1
14
8
1
7
W
e
s
t
9
5
t
h
S
t
r
e
e
t
L
e
n
e
x
a
,
K
a
n
s
a
s
6
6
2
1
5
P
9
1
3
3
2
2
5
1
5
0
F
9
1
3
3
2
2
5
1
5
5
ww
w
.
A
c
e
r
t
u
s
G
r
o
u
p
.
c
o
m
FRANCHISEE
7300 W. 129TH STREET
OVERLAND PARK, KANSAS
66213
PHONE: (913) 327-5555
FAX: (913) 327-5850
16
3
W
M
A
I
N
S
T
.
S
U
I
T
E
T
B
D
RE
X
B
U
R
G
,
I
D
A
H
O
PI
Z
Z
A
H
U
T
#
2
1
7
5
08/16/19
CI
T
Y
C
O
M
M
E
N
T
S
8
/
1
6
/
1
9
P2
WA
S
T
E
A
N
D
V
E
N
T
P
L
A
N
IMPORTANT NOTE:
PLUMBING CONTRACTOR SHALL WRAP THE WALK-IN FREEZER DRAIN
PIPING WITH HEAT TRACE TAPE, INSULATE WITH 3/4" ARMAFLEX
INSULATION, AND PROVIDE PVC FIELD JACKET FOR ALL CONDENSATE
PIPE IN THE FREEZER.
1.PLUMBING CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF THE SIZE &
DEPTH OF THE EXISTING SANITARY WASTE PIPING.
2.REFER TO SHEET P1 - PLUMBING SCHEDULE FOR LINE SIZES NOT SHOWN ON
PLAN.
3.ALL VENTS, VTRS, WCO'S, FCO'S, ETC. MAY NOT BE SHOWN ON PLAN. REFER TO
PLUMBING RISER DIAGRAM FOR VERIFICATION.
4.INSTALL VTR AT LOCATIONS AS SHOWN ON PLUMBING PLAN AND PLUMBING
RISER DIAGRAM. ALL OTHER VENTS GO TO VENT LINE AS SHOWN.
1
2
3
6
7
8
4
5
9
11/4" = 1'-0"WASTE AND VENT PLAN
2NTSKEYNOTES3NTSGENERAL NOTES
PROVIDE WITH TRAP PRIMER AND CONNECT TO NEAREST CW PIPING. REFER TO DETAIL 3/P4
VENT UP THROUGH ROOF. SEE RISER FOR ALL VENT AND PIPE SIZING. PLUMBING VENTS TO
BE LOCATED A MINIMUM OF 10' FROM FRESH AIR INTAKES. FIELD COORDINATE FINAL
LOCATIONS.
PROVIDE 1" COPPER CONDENSATE DRAIN LINE FROM THE EVAPORATOR COILS IN THE
WALK-IN COOLER AND FREEZER. PROVIDE P-TRAPS ON CONDENSATE DRAIN LINE AT
EVAPORATOR COILS. ROUTE TO FLOOR DRAIN AS SHOWN. CONDENSATE PIPING SHALL BE
INSTALLED AS HIGH AS POSSIBLE IN WALK-IN COOLER AND FREEZER TO ALLOW FOR
SHELVING INSTALLATION. 1-1/2" AIRGAP FOR INDIRECT WASTE REQUIRED.
PROVIDE 1" PVC CONDENSATE LINE FOR HVAC UNITS. DRAIN INTO FLOOR DRAIN LOCATION
AS SHOWN. PROVIDE AIR GAP PER CODE 1-1/2" MINIMUM REQUIRED.
PROVIDE SCREWED CLEAN OUT TYPICAL AS SHOWN.
ROUTE 2" WASTE LINE FROM 3-COMPARTMENT SINK TO FLOOR SINK WITH INDIRECT WASTE
CONNECTION. PROVIDE AIR GAP PER CODE. 4" MINIMUM REQUIRED.
ROUTE 2" WASTE LINE FROM DISHWASHER TO FLOOR SINK WITH INDIRECT WASTE
CONNECTION. PROVIDE AIR GAP PER CODE. 4" MINIMUM REQUIRED.
CONNECT NEW SANITARY WASTE PIPING TO EXISTING SANITARY WASTE LINE. VERIFY SIZE,
DEPTH AND LOCATION.
CONNECT NEW GREASE WASTE PIPING TO EXISTING GREASE WASTE LINE. VERIFY SIZE,
DEPTH AND LOCATION.
4NTSWASTE AND VENT ISOMETRIC RISER