HomeMy WebLinkAboutINSPECTION SUMMARY - 13-00359 - 584 E 4th S - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 08/13/2019 1:12 pm Permit Details Permit Number: 13-00359 584 E 4th S - SFR 584 E 4th S Building - Single Family Residence Permit Issued Date: 09/23/2013 Permit Inspection Statistics 25Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 68.00% Permit Inspection History *Refer to Individual Inspection Report for more Details 10/11/2013PassQuinton OwensFooting Inspection 2 #4 cont bars. layout good. Ufer bar installed.Inspector Comments: 10/15/2013PassSAUREY AMANDAFoundation Inspection #4 bar 2' o.c. each way w/ 2 horizontal in top 12". Okay to pour.Inspector Comments: 11/15/2013N/ASAUREY AMANDARadon-Ground Inspection 11/18/2013PassDon AllenPlumbing Underground Inspection All good to cover the under groundInspector Comments: 02/03/2014FailDon AllenPlumbing Rough-in need to move the water heater loop from behind the furnaceInspector Comments: 02/20/2014PassDon AllenPlumbing Rough-in 03/31/2014FailTed DyeBuilding Final handrail to basement is too high. It should be between 34"to 38" from the front of the step straight up to the top of the rail Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 13-00359 584 E 4th S - SFR 584 E 4th S Building - Single Family Residence Permit Status of (Open) as of Report Date: 08/13/2019 1:12 pm Permit Inspection Summary Building Inspection Type 12/30/2013FailTed DyeSheeting Sheer - area's marked with blue paint had nails missing through OSB.Inspector Comments: 01/02/2014PassQuinton OwensSheeting sheeting reinspect- sheeting approved. Action required: add backing for seam at electrical panel after panel is installed. Inspector Comments: 01/21/2014FailTed DyeFraming/Structure Inspection add anchor bolt by electrical panel add stud under girder truss in garage smote detector needed at bottom of stairs bearing walls in basement need anchor bolts provide truss spec's. Inspector Comments: 01/28/2014PassTed DyeInsulation Inspection 01/30/2014FailTed DyeFraming/Structure Inspection Provide truss spec's.Inspector Comments: 01/30/2014PassTed DyeInsulation Inspection Ok to hand drywall. Back sliding door missing Actions required: insulate when installed. Inspector Comments: 01/31/2014PassTed DyeFraming/Structure Inspection 02/06/2014PassTed DyeSheetrock/Drywall Inspection Drywall nail - ok to tape *insulate around sliding glass door. Avoid access (for jetted tub) to motor. Inspector Comments: 03/31/2014PassTed DyeSidewalk Inspection 03/31/2014FailTed DyeBuilding Final handrail to basement is too high. should be between 34" to 38"Inspector Comments: 04/01/2014PassTed DyeBuilding Final Hand rail changed to comply with code house ok to issue C.O. Inspector Comments: Electrical Inspection Type 01/21/2014PassSAUREY AMANDAElectrical Rough-in Okay for cover. Basement is unfinished.Inspector Comments: 03/31/2014PassBret StoddardResidential Electrical Service Inspection 03/31/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Page 2 of 3 (Continued) Permit Details Permit Number: 13-00359 584 E 4th S - SFR 584 E 4th S Building - Single Family Residence Permit Status of (Open) as of Report Date: 08/13/2019 1:12 pm Permit Inspection Summary Mechanical Inspection Type 01/28/2014PassDon AllenHVAC Rough-in all good to cover the rough in dryer vent works do to the dryer vent specs that was sent to the office Inspector Comments: 03/31/2014PassDon AllenHVAC Final Inspection all good for c/oInspector Comments: Plumbing Inspection Type 03/28/2014FailDon AllenPlumbing Final Inspection leak on master tub leak on kitchen sink Inspector Comments: 03/31/2014PassDon AllenPlumbing Final Inspection all good for c/oInspector Comments: Page 3 of 3