Loading...
HomeMy WebLinkAboutINVERTER SPECS - 19-00338 - 535 Angela Dr - SolarI N V E R T E R S www.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optmizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protecton and rapid shutdown for NEC 2014 and 2017, per artcle 690.11 and 690.12 UL1741 SA certfied, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytc capacitors Built-in module-level monitoring Outdoor and indoor installaton Optonal: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) W E B 1 9 0 5 - 0 2 0 0 4 0 6 / 0 6 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)- 3 - 3 - - - Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)3 3 3 3 3 3 3 Vac AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz Maximum Contnuous Output Current 208V - 16 - 24 - - - A Maximum Contnuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 A Utlity Monitoring, Islanding Protecton, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - - Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - 9 - 13.5 - - - Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protecton Yes Ground-Fault Isolaton Detecton 600k Sensitvity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nightme Power Consumpton < 2.5 W ADDITIONAL FEATURES Supported Communicaton Interfaces RS485, Ethernet, ZigBee (optonal), Cellular (optonal) Revenue Grade Data, ANSI C12.20 Optonal(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatc Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connecton Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convecton Natural convecton Operatng Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C opton)(4) ˚F / ˚C Protecton Ratng NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional setngs please contact SolarEdge support(2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-ratng informaton refer to: htps://www.solaredge.com/sites/default/files/se-temperature-deratng-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. W E B 1 9 0 5 - 0 2 0 0 4 0 6 / 0 6 / 1 9 T h i s i s n o t a b u i l d i n g p e r m i t