Loading...
HomeMy WebLinkAboutINSPECTION TICKET - M19-00050 - 4350 Woodland Dr - New SFRInspection Ticket Residential Building Review on 08/02/2019: Permit Number: M19-00050Permit Details Madison County - Single Family Residence Permit Issued Date: 08/02/2019 Final Inspections Required HVAC Final Inspection Plumbing Final Inspection Residential Electrical Final Inspection Residential Building Final 4350 Woodland Dr 4350 Woodland Dr - New SFR Inspection Details larry.beesley@rexburg.org Inspected By: Larry Beesley Residential Building Review on 08/02/2019: D ESCRIPTIO N CO M M EN TS STATUS Single Family Residential YES Flood Plain NO All rebar is tied in place with proper lap?COMPLETED Rebar is correct size and spaced as per plans?COMPLETED Rebar is a minimum or 1" from forms?COMPLETED Foundation walls w/ rebar (city ordinance)COMPLETED 1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl. interior bearing walls) R403.1.6.1 COMPLETED To Scale APPROVED Legible APPROVED Plot Plan APPROVED Floor/Foundation Plan APPROVED Section showing construction details APPROVED All Building Elevations APPROVED Design Criteria (identified on plans as Wind-85 mph, Snow-35 lb./sq. ft.) APPROVED Truss Calculation Sheets We need the truss specks from the manufacture of the trusses. APPROVED Floor Joist Details APPROVED Mechanical Design APPROVED Energy Calculations (R320 & Ch 11)APPROVED Building-Height (max. 30 ft.)APPROVED Proper Size (as per Table 403.1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing) APPROVED Rebar (2-#4 continuous)APPROVED Page 1 of 4 (Continued) Permit Number: M19-00050 D ESCRIPTIO N CO MMEN TS STATUS Footing Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab - interior) APPROVED Seismic Hold Downs and Braced wall Panels (R602.10) These are speck by your engineer.APPROVED Floors joists sized as per R502.3, Wood I-joists sized per manufr. APPROVED Joists Under Load Bearing Partitions shall be doubled. R502.4 APPROVED Girders sized per R502.5 or per manufr. Tables for engineered products APPROVED Cantilevers (comply with R502.3.3 or manufr instruction) APPROVED Floor Sheathing (3/4" min for joists, 24" oc & 5/8 for joists 16") R503.2.2 APPROVED Wall(bearing and nonbearing)stud sizes, hght & spacing per Tbl 602.3(5) R602.3 APPROVED Headers in Bearing Wall designed as per Tables 502.5(1&2) R602.7 APPROVED Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) APPROVED Rafter and Truss tie-downs R802.10.5 APPROVED Attic Access 22" x 30" min. opening R807 APPROVED 703.9.2.1 APPROVED Roof Ventilation as per R806 APPROVED Asphalt Shingles(slp>2:12) w/ice protection or Other type to comply w/R905 APPROVED Garage/House drywall separation (protect ext. walls & beams supporting habitable space) R302.6 APPROVED Door from Garage to House (1 3/8" solid wood or steel door, or 20 min. fire-rated door) R309.1 APPROVED Penetrations in previous 3 items to comply with R317.3 APPROVED House Numbers R321 APPROVED Interior and exterior stair illumination shall comply with R303.6 APPROVED Bathroom Fixture clearances comply with Figure R307.2 APPROVED *Areas w/ sloped veilings less than 5 ft. in height & furred ceilings less than 7 ft DO NOT comply. *50% or more of the required area must be at least 7ft high in rooms w/sloped ceiling APPROVED Egress clearance from window wells under cantilevered floors. R310.5 APPROVED Glazing at Hazardous Locations R308 APPROVED Emergency Egress in all sleeping rooms and basements w/ habitable space R310 APPROVED One required Exit Door shall comply with R311.2 APPROVED Page 2 of 4 (Continued) Permit Number: M19-00050 D ESCRIPTIO N CO MMEN TS STATUS Landings at top and bottom of stairways R311.7.5 and each side of each exterior door. R 311.3 APPROVED Stair Rise/Run (7 3/4' max. rise & 10" min. tread, nosing req'd if <11") APPROVED Stair width (36' min)APPROVED Stairway Headroom (6'8")APPROVED Handrails (34' to 38' above stair nosing)R311.7 APPROVED Stairway protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2 APPROVED Guardrails complying with R312 APPROVED Vapor retarder on warm in winter side of walls, ceiling and floors R601.3 APPROVED *Water Heater heat traps IECC 504.7 APPROVED Duct sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.4.3 APPROVED Plans match quantities & values on a "passing" RES check compliance report We need a copy of the RES check or you can do the prescriptive method for Insulation. Window U value 0.35 Attic R value 49 Walls R20 Floors R 30 Crawl space walls R 10/13 APPROVED Gas appliances not in bedrooms, bath., toilet rooms, or storage closets G2406.2 APPROVED Room access 36" min width/Attic access clear opening 20x30/Under floor r.o 22x30 M 306.2; 306.3 & 306.4 APPROVED Dyer Vent length 35' max w/8' transition (-5 per 90 deg turns) M504.6.41 APPROVED Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield) APPROVED Half openable 3sf window or Mech. Ventilation in bathrooms, water closets, and similar rooms. R303.3 APPROVED One room at least 120 sf APPROVED Smoke Alarms (each bedroom and common area and 1 on each level) R314 APPROVED Foundation Drainage (foundations on sift soil shall be designed per R405) APPROVED Damp proofing/Waterproofing to finish grade. R406.1 (fnd. extends 6" min above grade R404.1.6.1) APPROVED Crawl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.1) APPROVED Crawl Space Ventilation/insulation = 1 sf vent per 150 sq. ft. (with moisture barrier 1 sf. per 1500 sq. ft.) and within 3' of each corner (insulate walls vent to inside of home) R408.2 APPROVED Grading slope away from house. R401.3 APPROVED Page 3 of 4 (Continued) Permit Number: M19-00050 D ESCRIPTIO N CO MMEN TS STATUS Inspector Comments You house is reviewed for code compliance. The plans are engineered and must be built according to the engineered specks. Any changes must be approved in writing. You are good to permit and start Building. Thanks Page 4 of 4