Loading...
HomeMy WebLinkAboutPLANS - 19-00430 - 652 Vale Ln - Solar PanelsSolar Equipment SummaryMODULE TYPENUMBER OF MODSMODULE SIZE: WATTSSYSTEM SIZE: W A T T S HELIENE303009000Inverter(S)MANUFACTURERMODELNUMBER OFMICROINVERTERSSYSTEM OUT P U T AP SYSTEMSYC6001534.2JOB DETAILSROOF MATERIALSTANDARD ASPHALT SHINGLE ROOFSQ FT OF AR R A Y ARRAY AZIMUTH(S)144°544.2RACKING TYPEUL LISTED IRONRIDGE RACKING SYSTEM USING 48" ANCHORED C E N T E R S INSTALLATION SURFACE ANGLE30°GENERAL NOTESSHEET INDEXPAGE #DESCRIPTIONPV - 01TITLE SHEETPV - 02SITE PLAN / STRING DETAILSPV - 03ELECTRICAL LINE DIAGRAMPV - 04EQUIPMENT LABELSPV - 05RACKING DETAILS 1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST UT CODE OFREGULATIONS, NATIONAL ELECTRICAL CODE EDITION AND ALL APPLICABLE LOCAL CODE S A N D REGULATIONS. (Construction shall comply with UT Building Codes, 2017 NEC, And 2015 Internatio n a l F i r e Code.)2.ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS I N COMPLIANCE TO UL REQUIREMENTS TO ACCOMMODATE CONDUCTORS SHOWN.3.WHERE WIRE SIZES ARE INDICATED ON PLANS, FOR INDIVIDUAL CIRCUITS, THE WIR E S I Z E INDICATED SHALL APPLY TO THE COMPLETE CIRCUIT, UNLESS OTHERWISE NOTED.4.CONTRACTOR SHALL EXTEND WIRING FROM ALL JUNCTION BOXES, SWITCHES, ETC . A N D MAKE FINAL CONNECTION AS REQUIRED TO ALL BUILDING EQUIPMENT REQUIRING ELECT R I C A L CONNECTIONS.5.DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTE M S A N D WORK INCLUDED. FOLLOW DRAWING IN LAYING OUT WORK AND CHECK DRAWINGS OR O T H E R TRADES RELATING TO WORK TO VERIFY SPACE IN WHICH WORK WILL BE INSTALLED. MAI N T A I N HEADROOM AND MINIMUM CODE REQUIRED WORKING CLEARANCES AT ALL TIMES.6.ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT AREEXPOSED TO OUTSIDE ENVIRONMENT SHALL BE WEATHERPROOF TYPE, NEMA 3R.7.DISCONNECT SWITCHES SHALL BE MOUNTED ON INDIVIDUAL SUPPORTS, OR OTHE R W I S E DIRECTLY ON EQUIPMENT, PROVIDED.8.NO MODIFICATION TO EQUIPMENT IS NECESSARY. ALL ELECTRIC MATERIAL SHALL B E LISTED BY "UL" FOR THE TYPE OF APPLICATION AND "UL" LABEL SHALL APPEAR ON ALLELECTRICAL EQUIPMENT.9.WIRING METHOD SHALL BE EMT ABOVE GROUND AND MOUNTED IN CONCEALED SP A C E S (UNLESS APPROVED OTHERWISE) AND SCHEDULE - 40 PVC FOR BELOW GROUND INSTAL L A T I O N UNLESS NOTED OTHERWISE. 9 0 1 2 0 1 5 0 1 8 0 2 1 0 2 4 0 2 7 0 3 0 0 3 3 0 0 3 0 6 0 W E S N A Z I M U T H ID. CONTRACTORS LICENSE # & TYP E #036784CLASS - B100, E201, E200, E202APPLICABLE CODES2017 NATIONAL ELECTRIC CODE (NEC)2015 INTERNATIONAL BUILDING CODE (IBC)NABCEP CERTIFICATIONMICHAEL GARRISON PV 011818-019231 A R I A L V I E W P V - 0 1 N . T . S S H E E T # S C A L E : AHJ: DATE: DESIGNER: Revisions KIRK RICHMOND 652 VALE LANE REXBURG, ID 83440 REXBURG J. KALLIO 07/16/2019 2391 S. 1560 W. C Woods Cross, UT 84087 Phone: (801) 317-8444 A R I A L V I E W V I C I N I T Y M A P Project #114959 SYSTEM SIZE:9.0 kW (AC) 9.0 kW (DC) Input# of INVERTERS172731 9 0 1 2 0 150180210 240 270 300 330 030 6 0 W E S NAZIMUTHMMeter Location 3' Fire CodeNema-4 Soladeck SYMBOL KEY:Symbol:Meaning:CBPV Combiner Box DAC DisconnectSPSub-Panel M C B D S P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 Solar Equipment SummaryMODULE TYPENUMBER OF MODSMODULE SIZE: WATTSSYSTEM SIZE: W A T T S HELIENE303009000Inverter(S)MANUFACTURERMODELNUMBER OFMICROINVERTERSSYSTEM OUT P U T AP SYSTEMSYC6001534.2JOB DETAILSROOF MATERIALSTANDARD ASPHALT SHINGLE ROOFSQ FT OF AR R A Y ARRAY AZIMUTH(S)144°544.2RACKING TYPEUL LISTED IRONRIDGE RACKING SYSTEM USING 48" ANCHORED C E N T E R S INSTALLATION SURFACE ANGLE30° P V - 0 2 1 1 6 " = 1 ' S H E E T # S C A L E : AHJ: DATE: Designer Revisions KIRK RICHMOND 652 VALE LANE REXBURG, ID 83440 REXBURG J. KALLIO 07/16/2019 2391 S. 1560 W. C Woods Cross, UT 84087 Phone: (801) 317-8444 PV A C 10 0 A 1 2 0 / 2 4 0 V 2 0 A - 2 P CO M B I N E R B O X NEMA 3RJ-BOX NEMA-4SOLADECKJ-BOX 12143 4 B I - D I R E C T I O N A L S I N G L E P H A S E U T I L I T Y M E T E R U T I L I T Y G R I D 1 2 0 / 2 4 0 V E X I S T I N G 2 0 0 A S E R V I C E E N T R A N C E N / A N / A N / A 14 C O N D U I T A N D C O N D U C T O R S C H E D U L E T A G # D E S C R I P T I O N 1 ( 3 ) A P S Y S T E M S A C B U S L I N E ( 1 ) # 6 B A R E C O P P E R E G 2 ( I N A T T I C ) ( 3 ) # 1 0 - 3 R O M E X C A B L E , ( 1 ) # 1 0 T H W N - 2 E G 3 ( 1 ) 1 " E M T , ( 9 ) # 1 0 T H W N - 2 , ( 1 ) # 1 0 T H W N - 2 E G 4 ( 1 ) 1 " E M T , ( 3 ) # 8 T H W N - 2 , ( 1 ) # 1 0 T H W N - 2 E G P V A C O U T P U T A C O U T P U T C U R R E N T N O M I N A L A C V O L T A G E 2 4 0 V O L T S RAPID SHUTDOWN COMPLIANCE DEVICESR M O D U L E S P E C I F I C A T I O N S M A N U F A C U R E R H E L I E N E M O D E L 3 0 0 M A X P O W E R - P O I N T C U R R E N T ( I M P ) - A M P S 9 . 6 6 M A X P O W E R - P O I N T V O L T A G E ( V M P ) - V O L T S 3 3 . 4 4 O P E N C I R C U I T V O L T A G E ( V O C ) - V O L T S 4 0 . 1 3 S H O R T C I R C U I T C U R R E N T ( I S C ) - A M P S 1 0 . 2 2 M A X S E R I E S F U S E ( O C P D ) - A M P S 2 0 M A X P O W E R ( P M A X ) 3 0 0 W A T T I N V E R T E R S P E C I F I C A T I O N S M A N U F A C T U R E R A P S Y S T E M S M O D E L Y C 6 0 0 M A X D C I N P U T V O L T A G E 5 5 V D C M A X O U T P U T P O W E R 6 0 0 W N O M I N A L A C O U T P U T V O L T A G E 2 4 0 V A C N O M I N A L A C O U T P U T C U R R E N T 2 . 2 8 A M A X F U S E ( O C P D ) 2 0 A I N T E R C O N N E C T I O N P C C M A D E I N E X I S T I N G E X T E R I O R 2 4 0 V A C , 2 0 0 A A C 1 P H A S E M E T E R M A I N P A N E L W I T H S U P P L Y S I D E F E E D E R S . T A P W I L L U S E I N S U L A T E D P I E R C I N G C O N N E C T E R ( N S I I N D U S T R I E S ) W I T H 6 0 A A C F U S E D D I S C O N N E C T W I T H 5 0 A F U S E S A S O C P D . T H I S C O N N E C T I O N S H A L L B E M A D E I N C O N F O R M A N C E W I T H 2 0 1 7 N E C 7 0 5 . 1 2 ( A ) 2 3 0 . 8 2 ( 6 ) . Notes:1. This system meets the requirements of NEC 690.412. The DC conductors are not bonded to ground and the inverters do not require a GEC.3. NEC 690.43(C) Structure as Equipment Grounding Conductor allows for equipment to beused as the EGC in a photovoltaic system.4. The devices listed and identified for grounding the equipment may be stand-alonegrounding components or UL-2703 listed mounting hardware. Modules are bonded to theracking with listed and approved grounding components.5. Equipment operating 150 volts or greater shall only be serviced or replaced by qualifiedpersonnel. Field protection may be in the form of conduit, closed cabinet or an enclosurewhich require use of tools to open.6. Solar Photovoltaic System equipment will be installed in accordance with therequirements of Art. 690 of the 2017 NEC.7. Local utility provider shall be notified prior to use and activation of any solar photovoltaicinstallation.8. All solar modules, equipment, and metallic components are to be grounded inaccordance with code and the manufacturer's installation instructions. 9. Wiring must be permanently and completely held off of the roof surface per NEC 110.2,110.3(A), 110.3(B) & 300.4 P V D C S T R I N G I N V E R T E R I N P U T M A X I M U M V O L T A G E M A X I M U M C I R C U I T C U R R E N T M A X R A T E D O U T P U T C U R R E N T O F T H E C H A R G E C O N T R O L L E R A N D O R D C - T O D C C O N V E R T E R ( I F I N S T A L L E D ) 6 0 A 1 2 0 / 2 4 0 V F U S E D D I S C O N N E C T ( 2 ) 5 0 A F U S E S S R W I T H I N 1 0 ' O F U T I L I T Y M E T E R 4 2 2 0 A - 2 P 2 0 A - 2 P 2 0 0 A - 2 P T A P 3 4 . 2 P V - 0 3 N . T . S S H E E T # S C A L E : AHJ: DATE: Designer Revisions KIRK RICHMOND 652 VALE LANE REXBURG, ID 83440 REXBURG J. KALLIO 07/16/2019 2391 S. 1560 W. C Woods Cross, UT 84087 Phone: (801) 317-8444 ALL SIGNAGE MUS T B E P E R M A N E N T L Y A T T A C H E D A N D B E W E A T H E R RESISTANT/SUNLI G H T R E S I S T A N T A N D C A N N O T B E H A N D - W R I T T E N CONDUITS, ENCLOSURES, OR MC Cable T H A T C O N T A I N D C C I R C U I T S E V E R Y 1 0 ' L O C A T E D A T S E R V I C E P A N E L B O A R D N E C 6 9 0 . 5 4 LOCATED ON STRING INVERT E R ( I F U S E D ) N E C 6 9 0 . 5 3 LOCATED AT MAIN PV DISC O N N E C T N E C 6 9 0 . 1 3 ( B ) LOCATED AT RAPID SHUTDOWN D I S C O N N E C T N E C 6 9 0 . 5 6 ( C ) ( 3 ) L O C A T E D A T S E R V I C E P A N E L N E C 7 0 5 . 1 0 L O C A T E D A T P V B R E A K E R I N P A N E L B O A R D N E C 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( b ) L O C A T E D A T S E R V I C E P A N E L N E C 6 9 0 . 5 6 ( C ) ( 1 ) 2 4 0 V LOCATED ON MULTI BRA N C H P V S U B - P A N E L 3 4 . 2 N / A N / A N / A P V - 0 4 N . T . S S H E E T # S C A L E : AHJ: DATE: Designer Revisions KIRK RICHMOND 652 VALE LANE REXBURG, ID 83440 REXBURG J. KALLIO 07/16/2019 2391 S. 1560 W. C Woods Cross, UT 84087 Phone: (801) 317-8444 T Y P . 2 4 " S P A N T R U S S E S T Y P . M I D - C L A M P T Y P . L - F O O T T Y P . E N D - C L A M P T Y P . L - F O O T P V Q U I C K M O U N T 4 8 " @ O . C M A X FLASHFOOT S T A N D O F F FLUSH MOUNTED ARRAY C O M P O S I T E S H I N G L E ± 1 ' - 7 " 9"MI N . SOLAR P A N E L P R E - M A N U F A C T U R E D H O L D D O W N C L I P , 4 A T E A C H P A N E L (TY P . ) - A T T A C H W / 3 / 8 " S . S B O L T S PRE-MANUFACTURED 2-1/2"TALL x 2" WIDE L-FOOT -ATTACH TO RAIL W/ 3/8" S.S.BOLTS, ATTACH TO ROOFWITH (1) 5/16"x4-1/2" LAGBOLT INTO TRUSS WITHMINIMUM 3" EMBEDMENT E X I S T I N G R O O F S H E A T H I N G T O P C H O R D O F E X I S T I N G R O O F T R U S S E X I S T I N G C O M P O S I T E R O O F I N G A L U M I N U M F L A S H I N G S E A L E D W I T H C A U L K P R E - M A N U F A C T U R E D ALU M I N U M M O U N T I N G R A I L 4 : 1 2 P I T C H C O M P O S I T E S H I N G L E R O O F TYP. L-FOOT PVQUICK MOUNT48" SPAN TYP. 24" SPAN TRUSSESTYP. MID-CLAMP TYP. L-FOOT T Y P . E N D - C L A M P M E E T S O R E X C E E D S 2 0 1 5 I B C I R C C O N S T R U C T I O N S T A N D A R D S C A S E 1 L o a d C a l c u l a t i o n s 2 X 4 C o n s t r u c t i o n 2 4 " o n C e n t e r T r u s s e s H e l i e n e 3 0 0 - 3 0 0 W A T T P V P A N E L : 4 8 . 5 L B S / P A N E L I R O N R I D G E X R C O N N E C T I O N H A R D W A R E : . 7 3 5 P L F * 6 . 6 6 F T / P A N E L = 4 . 8 9 5 1 L B S / P A N E L S Y S T E M I N C L U D E S 3 0 P A N E L S A N D I R O N R I D G E M O U N T I N G H A R D W A R E : 3 0 X 4 8 . 5 = 1 4 5 5 L B S A = L x W ( P A N E L ) : 1 7 . 9 6 S Q F T A R R A Y : 1 7 . 9 6 S Q F T X 3 0 = 5 3 8 . 8 x 3 0 P S F = 1 6 1 6 4 L B S P U L L O U T S T R E N G T H C O N N E C T O R 5 / 1 6 L A G B O L T 6 0 S T A N D O F F S ( 6 0 L A G S ) 6 0 x 3 ' ' E M B E D x 2 0 5 L B S = 3 6 9 0 0 L B S R O O F L O A D B E A R I N G 1 6 4 6 . 1 L B S / 6 0 S T A N D O F F S = 2 7 . 4 4 L B S T O T A L W E I G H T = P A N E L S + H A R D W A R E 1 6 4 6 . 1 L B S 1 6 4 6 . 1 L B S / 5 3 8 . 8 S Q F T = 3 . 0 6 P S F P V - 0 5 N . T . S S H E E T # S C A L E : AHJ: DATE: Designer Revisions KIRK RICHMOND 652 VALE LANE REXBURG, ID 83440 REXBURG J. KALLIO 07/16/2019 2391 S. 1560 W. C Woods Cross, UT 84087 Phone: (801) 317-8444 P V - 0 5 N . T . S S H E E T # S C A L E : AHJ: DATE: Designer Revisions KIRK RICHMOND 652 VALE LANE REXBURG, ID 83440 REXBURG J. KALLIO 07/16/2019 2391 S. 1560 W. C Woods Cross, UT 84087 Phone: (801) 317-8444