HomeMy WebLinkAboutREVIEW RESPORT - 17-00378 - 525 S Center St - BYUI - Smith RemodelReview Report Current Building Review Status: REVISIONS Application Number: 17-00378Permit Details Application Received Date: 07/10/2017 Commercial Remodel Application Approved Date: Application Approved Status: APPROVED 07/10/2017 525 South Center St BYUI - Smith Remodel Status of Plan Reviews Completed 07/12/2017Electrical Review COMPLETED 07/12/2017Plumbing Review N/A 07/12/2017HVAC Review COMPLETED 07/20/2017Fire Alarm Review COMPLETED 07/26/2017Building Review REVISIONS Permit Review Status Plan Reviews Still in Progress Building Review DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Accessible Means of Egress meets the requirements of IBC Section 1007 REVISIONSWhere a space is required to have 2 exits, then two accessible means of egress shall be provided (see comments on aisles). Existing accessible means of egress shall be maintained in alterations of existing buildings (commentary on exception 1). *Revisions Response : The tables and chairs within Classroom 250 have been rearranged and limited to less than 50, thus eliminating the need for a second means of egress. Aisles meet the requirements of IBC Section 1017 REVISIONSRoom 250, classroom plan, does not meet aisle width requirement for 2nd exit on east side of room. *Revisions Response : The tables and chairs within Classroom 250 have been rearranged and limited to less that 50, thus eliminating the need for a specific aisle width or a second means of egress from the room. Assembly Exiting meets the requirements of IBC Section 1028 REVISIONS* 20" is provided between chairs in room 240. (approved) * Aisle access width for seating at tables shall be measured to a line 19" from the table edge. 36" between tables leaves only 17" clear width (see IBC 1028.10.1) *Revisions Response : The number of occupants was reduced from 60 to less than 50, thus eliminating the need for an aisle access width to meet IBC 1028.10.1. See attached documents. Fire resistance rating of building elements meet the req. of IBC Sect 703, 704 Maintain rating of existing fire protected elements. COMPLETED Reviewed By: Quinton Owens Review Date: 07/26/2017 Plan Review Details quinton.owens@rexburg.org Building Review Status: REVISIONS Page 1 of 2 Approval of plans does not constitue approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Automatic sprinklers are provided or exempted as per IBC Section 903.2 Existing building. Room changes affecting sprinkler heads to be approved by Dale. COMPLETED Page 2 of 2 Approval of plans does not constitue approval of variance from code