HomeMy WebLinkAboutREVIEW REPORT - 17-00372 - 720 Cornelison Ave - Juniper Sands Apartments - Bldg #2 - 48 UnitsReview Report Current Planning and Zoning Review - Site Plan Status: APPROVED Application Number: 17-00371Permit Details Application Received Date: 07/06/2017 Multi-Family Residential Application Approved Date: Application Approved Status: APPROVED 07/06/2017 Juniper Sands Apartments - Building #1 Status of Plan Reviews Completed 07/11/2017Electrical Review REVISIONS 07/12/2017Plumbing Review COMPLETED 07/12/2017HVAC Review COMPLETED 07/13/2017Fire Department Review - Site Plan COMPLETED 07/21/2017Planning and Zoning Review - Site Plan REVISIONS 07/26/2017Building Review REVISIONS 08/04/2017Public Works Review - Site Plan REVISIONS 08/04/2017Planning and Zoning Review - Site Plan COMPLETED 08/04/2017Building Review COMPLETED 08/16/2017Public Works Review - Site Plan COMPLETED 09/08/2017Electrical Review COMPLETED Permit Review Status Plan Reviews Still in Progress DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Building setbacks (front,side,back yards)No parking within 10 ft setback. Per scale, yes, but not identified. COMPLETED Sidewalks along right of way access main streets Standard width required of 5 ft.COMPLETED Reviewed By: Quinton Owens Review Date: 08/04/2017 Plan Review Details quinton.owens@rexburg.org Planning and Zoning Review - Site Plan Status: APPROVED Page 1 of 1 Approval of plans does not constitue approval of variance from code Review Report Current Building Review Status: APPROVED Application Number: 17-00371Permit Details Application Received Date: 07/06/2017 Multi-Family Residential Application Approved Date: Application Approved Status: APPROVED 07/06/2017 Juniper Sands Apartments - Building #1 Status of Plan Reviews Completed 07/11/2017Electrical Review REVISIONS 07/12/2017Plumbing Review COMPLETED 07/12/2017HVAC Review COMPLETED 07/13/2017Fire Department Review - Site Plan COMPLETED 07/21/2017Planning and Zoning Review - Site Plan REVISIONS 07/26/2017Building Review REVISIONS 08/04/2017Public Works Review - Site Plan REVISIONS 08/04/2017Planning and Zoning Review - Site Plan COMPLETED 08/04/2017Building Review COMPLETED 08/16/2017Public Works Review - Site Plan COMPLETED 09/08/2017Electrical Review COMPLETED Permit Review Status Plan Reviews Still in Progress DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Fire barriers meet the requirements of IBC Section 707 Fire riser room and stair enclosure walls are constructed as fire barriers - fire rating extends up to roof or floor deck above regardless of ceiling rating. COMPLETED Penetrations meet the requirements of IBC Section 714 No fire stop penetration details provided. Fire rating of walls and horizontal assemblies shall be maintained at all penetrations. COMPLETED Dwelling Units meet the requirements of IBC Section 1107 3 type A required, 2 one bedroom unit & 1 two bedroom provided. All other ground floor units are type B COMPLETED Toilets, Bathing Fac., Sinks, Kit. and Drink. Fount. meet IBC Sec. 1109 Note: In type A units, Floor & wall finish to be done with removable cabinet allowed under kitchen sink for wheelchair forward approach (not identified on plans). COMPLETED Site Grading meets the requirements of IBC Section 1804.3 Grade shall slope away from building for drainage per 1804.3 COMPLETED Reviewed By: Quinton Owens Review Date: 08/04/2017 Plan Review Details quinton.owens@rexburg.org Building Review Status: APPROVED Page 1 of 2 Approval of plans does not constitue approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Exit Enclosures meet the requirements of IBC Section 1022 The following requirements were not identified in revisions but acknowledged in person they would be done. * Barrier required in exit enclosure at stairs descending below the exit discharge level - Not identified with revision * Required stair signage per 1022.9 is not identified on plans. Recommended for review and approval before installation - Not identified with revisions. COMPLETED Page 2 of 2 Approval of plans does not constitue approval of variance from code