HomeMy WebLinkAboutSTRUCTURAL EVALUATION - 19-00410 - 175 W 2nd S - CUP: AT&T AntennaEng. # 12962 1_,2_01
Julyy 16, 2019
Page 1 of 1
AMERICAN TOWER'
CORPORATION
Structural Evaluation
AT
Mount Type
Lines
Carrier
Reviewed By:
ID
Platform with Handrails
(2) 15/8" Hybriflex
(12) 7/8" Coax
VERIZON WIRELESS
NAL "P*
Carrier Site Number
135091
MADISON ID
& Name
SFO
Site Location
249 Erickson Dugway Rd
1 Generic 6' HP Dish
Flush
-
CommscopeJAHH-65B-R3B
Rexburg, ID 83440-4948, Madison County
o��SvGEN
-
43.8007 N / 111.7779 W
at7g09`
W �p
IgTE �P
Tower Description
150 ft Monopole
Basic Wind Speed
90 mph (3 -second gust, VASD)/115 mph (3 -second gust, VutT)
Basic Wind w/ Ice
50 mph (3 -second gust) w/.25" radial ice concurrent
OF
"SHA
Applicable Code
ANSI/TIA-222-G / 2015 IBC
Authorized by "EOR"
Evaluation Results:
The loading in the tables below was evaluated with respect to the tower and foundation
U1 16 2019 11;41 AM COSH
capacities. As future loading is added, or if actual loading is different from these tables,
re-evaluation shall be required. This tower and foundation are adequate to support the
below loads in conformance with specified requirements.
Created By: Parvin Nikpoorparizi
Existing and Reserved Equipment
Elev.'(ft)
Qty Antenna
Mount Type
Lines
Carrier
152.0
2 Antel LPD -4019
Platform with Handrails
(2) 15/8" Hybriflex
(12) 7/8" Coax
VERIZON WIRELESS
1 VZW Unused Reserve: 6640 sq in
4 Antel RWA-80014_
52.0
1 Generic 6' Ice Shield
Flush
-
2
46.0
1 Generic 6' HP Dish
Flush
-
CommscopeJAHH-65B-R3B
Equipment to be Removed
Elev'(ft)
qty
Antenna
MountType
Lines
Carrier
152.0
3
Nokia B5 RRH4x40-850
VERIZON WIRELESS
3 Ericsson Radio 4449 - B13&B5
VERIZON WIRELESS
3
Alcatel -Lucent B13 RRH4x30-4R
3
Alcatel -Lucent B25 RRH4x30-4R
2
RFS DB-B1-6C-12AB-OZ
3
Alcatel -Lucent RRH4X45-B66 w/ Solar Shield
6
CommscopeJAHH-65B-R3B
46.0
-
-
-
(1) EW63
Proposed Equipment
Elev.'(ft)
Qty Antenna
Mount Type
Lines
Carrier
152.0
3 Ericsson 8843 Rev 2
platform with Handrails
-
VERIZON WIRELESS
3 Ericsson Radio 4449 - B13&B5
2 Raycap RxxDC-3315-PF-48
6 Amphenol Antel HEX656CW000OG
46.0
- -
-
(1) E65
'Contracted elevations are shown for appurtenances within contracted installation tolerances. Appurtenances outside of contract limits are shown at installed elevations.
Install proposed lines inside the pole shaft.
ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 — 919-468-0112 Office — 919-466-5414 Fax - www.americantower.com