Permit Status of (Open) as of Report Date: 07/25/2019 8:29 am
Permit Details Permit Number: 12-00308
614 Tanglewood Dr - SFR
614 Tanglewood Dr
Building - Single Family Residence
Permit Issued Date: 07/30/2014
Permit Inspection Statistics
20Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 85.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
07/23/2012PassQuinton OwensResidential Footing Inspection
2 cont rebar supported with clearances. OK to pour.
Layout good.
Inspector Comments:
07/24/2012PassQuinton OwensFoundation Inspection
Foundation approved. UFER installed.Inspector Comments:
10/03/2012FailQuinton OwensResidential Framing/Structure Inspection
Sheathing: finish stapling at missed locations (marked in crayon) and nails missed
on hold downs south side of garage.(9-28, Quinton)
Missing Truss bracing (B1, B2, & D5), No popout shown at back door on
approved plans (need eng'r approval). Finish framing vault (kitchen side). Eng'r
requirement #2 - A35's on cantilevered joists. Tempered window above tub
(switched with kitchen window).
Inspector Comments:
10/05/2012PassQuinton OwensResidential Framing/Structure Inspection
A35 ties required by eng'r on cantilevered joists.(reinspect with insulation)Inspector Comments:
10/10/2012PassQuinton OwensResidential Insulation Inspection
Top of middle & left window in living room have insufficient foam seal.
Note: clear wood shavings away from B-vent.
Inspector Comments:
10/19/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection
Fix wall on side of fridge location (stud in middle not straight or out of line) then
screw drywall in corner. Missed screws in closet of front bedroom (south side) on
back wall and above door.
Inspector Comments:
12/13/2012PassQuinton OwensSidewalk Inspection
12/13 sidewalk done at driveway only. Sidewalk OK to pour. Gravel base 6'
compacted.
Inspector Comments:
01/07/2013PassQuinton OwensResidential Building Final
Temp: sidewalk to be done as soon as weather permits.Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00308
614 Tanglewood Dr - SFR
614 Tanglewood Dr
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 07/25/2019 8:29 am
Permit
Inspection
Summary
Electrical Inspection Type
08/22/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
10/05/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
10/3/12 - Approved for cover in the main floor entirely except the garage area
above the main panel-nail plates required for SER cable-unfinished basement,
garage lights have 14 gauge wire between the three-way switches therefore will
have to be on a 15A OCPD(breaker).
12/5/12 - Approved for cover in the entire house including the garage-14 gauge
(14/3) still remains in the garage three-way.
Inspector Comments:
01/07/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and a C.O.-unfinished basement entirely-no A/C unit
installed.
Inspector Comments:
Mechanical Inspection Type
10/03/2012PassQuinton OwensHVAC Rough-in
Repair supply duct taken out to fix stair headroom. (reinspect anytime -
unfinished basement)
Inspector Comments:
01/07/2013PassQuinton OwensHVAC Final Inspection
Plumbing Inspection Type
07/30/2012FailDon AllenPlumbing Underground Inspection
need a 10 foot between the water and sewerInspector Comments:
08/20/2012PassSAUREY AMANDAPlumbing Underground Inspection
08/16/2012: Looks good, per Nathan Wood.Inspector Comments:
10/15/2012PassDon AllenPlumbing Rough-in
All good to cover.Inspector Comments:
01/07/2013FailDon AllenPlumbing Final Inspection
Need opening to pump on master tab. Call when done.Inspector Comments:
01/08/2013PassDon AllenPlumbing Sewer
01/08/2013PassDon AllenPlumbing Water
01/08/2013PassDon AllenPlumbing Final Inspection
All good for C/OInspector Comments: