HomeMy WebLinkAboutPLANS - 19-00420 - 59 Professional Plz St - Strobel Dentist Office Solar ProjectSCOPE OF WORK SYSTEM SIZE:STC: 33 x 350 = 11.580 kW PTC: 33 x 337.7 = 11.144 kW DC (33) BOVIET BVM6612-350 (1) SMA SB7.7-US OWNER NAME:DIRK STROBEL DENTIST OFFICE PROJECT MANAGER NAME:TREVER GERDES PHONE: 2085698777 LECTRICIAN NAMF:BRIAN MEYERS LIC.NO: ELE-M-23939 AUTHORITIES HAVING JURISDICTION BUILDING: CITY OF REXBURG ZONING: CITY OF REXBURG UTILITY: DESIGN SPECIFICATIONS OCCUPANCY: II CONSTRUCTION: ZONING:OFFICE APPLICABLE CODES & STANDARDS BUILDING: IBC 2015 ELECTRICAL: NEC 2017 FIRE:IFC 2015 PROJECT INFORMATION NEW PV SYSTEM: 11.550 kWp DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 2.1.1 SITE NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 2.2.1 EQUIPMENT LOCATIONS 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C). 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.3.1 STRUCTURAL NOTES: 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 2.4.1 GROUNDING NOTES: 2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.4.3 PV SYSTEMS REQUIRE AN EQUIPMENT GROUNDING CONDUCTOR. ALL METAL ELECTRICAL EQUIPMENT AND STRUCTURAL COMPONENTS BONDED TO GROUND, IN ACCORDANCE WITH 250.134 OR 250.136(A). ONLY THE DC CONDUCTORS ARE UNGROUNDED. 2.4.4 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 2.4.5 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURE CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 2.4.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 2.4.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 2.4.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119] 2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 2.4.10 DC PV ARRAYS SHALL BE PROVIDED WITH DC GROUND-FAULT PROTECTION MEETING THE REQUIREMENTS OF 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS 2.5.1 INTERCONNECTION NOTES: 2.5.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12 (B)] 2.5.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(B)(2)(3)]. 2.5.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)]. 2.5.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C). 2.5.6 FEEDER TAP INTERCONECTION (LOAD SIDE) ACCORDING TO NEC 705.12 (B)(2)(1) 2.5.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.5.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)]. 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. 2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED. THEREFORE BOTH MUST OPEN WHERE A DISCONNECT IS REQUIRED, ACCORDING TO NEC 690.13. 2.6.5 ISOLATING DEVICES OR EQUIPMENT DISCONNECTING MEANS SHALL BE INSTALLED IN CIRCUITS CONNECTED TO EQUIPMENT AT A LOCATION WITHIN THE EQUIPMENT, OR WITHIN SIGHT AND WITHIN 10 FT OF THE EQUIPMENT. AN EQUIPMENT DISCONNECTING MEANS SHALL BE PERMITTED TO BE REMOTE FROM THE EQUIPMENT WHERE THE EQUIPMENT DISCONNECTING MEANS CAN BE REMOTELY OPERATED FROM WITHIN 10 FT OF THE EQUIPMENT, ACCORDING TO NEC 690.15 (A). 2.6.6 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D) 2.6.7 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 2.6.8 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED, THEREFORE BOTH REQUIRE OVER-CURRENT PROTECTION, ACCORDING TO NEC 240.21. (SEE EXCEPTION IN NEC 690.9) 2.6.9 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. 2.7.1 WIRING & CONDUIT NOTES: 2.7.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.7.3 ALL CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 2.7.4 EXPOSED PV SOURCE CIRCUITS AND OUTPUT CIRCUITS SHALL USE WIRE LISTED AND IDENTIFIED AS PHOTOVOLTAIC (PV) WIRE [690.31 (C)]. PV MODULES WIRE LEADS SHALL BE LISTED FOR USE ON PV ARRAYS, ACCORDING TO NEC 690.31 (A). 2.7.5 PV WIRE BLACK WIRE MAY BE FIELD-MARKED WHITE [NEC 200.6 (A)(6)]. 2.7.6 MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. 2.7.7 ACCORDING TO NEC 200.7, UNGROUNDED SYSTEMS DC CONDUCTORS COLORED OR MARKED AS FOLLOWS: DC POSITIVE-RED, OR OTHER COLOR EXCLUDING WHITE, GREY AND GREEN DC NEGATIVE- BLACK, OR OTHER COLOR EXCLUDING WHITE, GREY AND GREEN 2.7.8 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE*, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY * IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. 2017S A-201 01EMAIN ENTRANCE DOOR PROPERTY LINE SOLAR (PV) MODULE EQUIPMENT GROUND CONDUIT FIRE CLEARANCE (E) UTILITY METERM S PNL VMEP AC DISCONNECT AC PANELBOARD PV REVENUE METERMAIN ELECTRICAL PANEL DC/AC INVERTER DC DISCONNECT COMBINER BOX JUNCTION BOX I DCSW CBR JB U UTILITY POLE TB RSD TAP BOX RAPID SHUTDOWN SUB (AC) PANEL METER/MAIN SUB M/M CBR MODULE STRINGING (DC) COMBINER BOX A B MODULE STRINGING MODULE STRINGING ATTACHMENTS RAILS ROOF RAFTERS N EW S A-201 D1 26 SYMBOL LEGEND C MODULE STRINGING D MODULE STRINGING SHEET KEYNOTE INDICATOR DETAIL INDICATOR ELEVATION INDICATOR NORTH INDICATOR DISCLAIMER: PLEASE NOTE THAT THE ABBREVIATIONS, ANNOTATIONS, AND SYMBOLS LISTED ARE INTENDED TO ILLUSTRATE THOSE THAT ARE COMMONLY USED; NOT ALL ARE NECESSARILY UTILIZED WITHIN THIS SET OF DRAWINGS. NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: T-001.00 COVER PAGE (SHEET 1 OF 19) 01 AERIAL PHOTO NOT TO SCALE N EW S 02 PLAT MAP NOT TO SCALE PR O F E S S I O N A L P L A Z A N EW S SHEET SCHEDULE SHEET NUMBER SHEET TITLE T-001 COVER PAGE A-101 SITE PLAN A-102 ELECTRICAL PLAN E-601 SINGLE LINE DIAGRAM A-103 SOLAR ATTACHMENT PLAN E-602 PLACARD S-501 ASSEMBLY DETAILS R-001 - R-002 RESOURCE DOCUMENT CONSTRUCTION NOTES GENERAL NOTES 1.FIELD VERIFY ALL MEASUREMENTS 2.ITEMS BELOW MAY NOT BE ON THIS PAGE NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: N EW S 01/8" = 1'-0" SITE PLAN01 4'8' A-101.00 SITE PLAN (SHEET 2 OF 19) P R O F E S S I O N A L P L A Z A INVERTER AC DISCONNECT METERMAIN 28 ' - 6 " 39'-8" 13'-7" 9' - 1 1 " GENERAL NOTES 1.FIELD VERIFY ALL MEASUREMENTS 2.SEE SHEET T-001 FOR LEGEND OF SYMBOLS MODULE: BOVIET BVM6612-350 350 WATTS 37.09" 77 . 0 1 " NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: 01/4" = 1' ELECTRICAL PLAN012'4' A-102.00 ELECTRICAL PLAN (SHEET 3 OF 19) (N) (1) INVERTER (N) (1) AC DISCONNECT EXTERIOR EQUIPMENT (E) (1) METER/MAIN A MODULE STRINGING FIRE CLEARANCE B MODULE STRINGING 3'-0" FIRE ACCESS PATH 3'-0" FIRE ACCESS PATH 3'-0" FIRE ACCESS PATH 3'-0" FIRE ACCESS PATH 3'-0" FIRE ACCESS PATH C MODULE STRINGING A A A A A A A A A A С С С С С С С В В В В С С С С В ВВВ В A В В ARRAY 3 - 5.600 kW [x16] (N) MODULES TILT: 20 DEGREES AZIMUTH: 90 DEGREES N EW S ARRAY 2 - 2.450 kW [x7] (N) MODULES TILT: 20 DEGREES AZIMUTH: 180 DEGREES ARRAY 1 - 3.500 kW [x10] (N) MODULES TILT: 20 DEGREES AZIMUTH: 270 DEGREES (N) (1) TIGO ACCESS POINT RS-485 (N) (1) TIGO CCA MODULE: BOVIET BVM6612-350 350 WATTS 37.09" 77 . 0 1 " NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: 03/16" = 1' ROOF FRAMING PLAN012'-8"5'-4" A-103.00 ROOF FRAMING PLAN (SHEET 4 OF 19) ROOF MATERIAL IS ASPHALT SHINGLE RAILLESS SOLAR MODULES ATTACHED TO ROOF SURFACE (SEE SHEET S-501 FOR MOUNTING DETAILS) N EW S 19 ' - 3 " 34 ' - 8 " 19'-3" TRUSSES 03 TO UTILITY GRID (UG) L1 L2 N (E) GROUNDING ELECTRODE GROUND ROD (E) MAIN SERVICE PANEL 120/240 V 1Ø, 3W MAIN BUSS:200A N G (E) UTILITY METER TO (E) LOADS NN L2 L1 EQUIPMENT ABOVE LINE IS (N) NEW EQUIPMENT BELOW LINE IS (E) EXISTING UNLESS OTHERWISE NOTED. G 04 (N) 60А AC DISCONNECT TIGO CLOUD CONNECT CONTROLLER L2 N G G L1 01 (N) SMA SB7.7-1SP-US-40-240V BOVIET BVM6612-350 SMA TS4-R-O OPTIMIZERS 11 11 11 G 02 (N) JUNCTIION BOX (E) 40А (E) MAIN A200 TAP TIGO ACCESS POINT RS - 4 8 5 C A B L E NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: 01 SINGLE LINE DIAGRAM NOT TO SCALE E-601.00 SINGLE LINE DIAGRAM (SHEET 5 OF 19) CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%)BASE AMP.DERATED AMP.TERM. TEMP. RATING AMP. @ TERMINAL 01 3 10 AWG PV WIRE, COPPER FREE AIR 2 N/A 6 AWG BARE, COPPER 0.71 (55.8°C)1 11.98A 14.98A 55A 39.05A 75°C 50A 02 1 10 AWG THWN-2, COPPER 1" DIA PVC-40 6 N/A 10 AWG THWN-2, COPPER 0.71 (55.8°C)0.8 11.98A 14.98A 45A 25.56A 75°C 35A 03 1 8 AWG THWN-2, COPPER 1" DIA PVC-80 2+N N/A 10 AWG THWN-2, COPPER 0.96 (33.8°C)1 32A 40A 55A 52.8A 75°C 50A 04 1 8 AWG THWN-2, COPPER 1" DIA PVC-80 2+N 40A 10 AWG THWN-2, COPPER 0.96 (33.8°C)1 32A 40A 55A 52.8A 75°C 50A BILL OF MATERIALS CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION MODULE BOVIET BVM6612-350 PM1-33 33 PIECES 1 BOVIET BVM6612-350 350W 72 CELLS, POLYCRYSTALLINE SILICON INVERTER SMA SB 7.7-1SP-US-40 (240V)I1 1 PIECE 1 SMA SB 7.7-1SP-US-40 (240V) 7680W INVERTER MONITORING TIGO TIGO CCC C1 1 PIECE 1 TIGO CLOUD CONNECT CONTROLLER MONITORING TIGO TAP T1 1 PIECE 1 TIGO ACCESS POINT (TAP) MODULE OPTIMIZER SMA TS4-R-S PO1-33 33 PIECES 1 SMA TS4-R-O OPTIMIZER (REQUIRED PART OF INVERTER'S DISTRIBUTED DC ARCHITECTURE) DISCONNECT SQUARE D D222NRB SW1 1 PIECE 1 SQUARE D D222NRB, 2-POLE, 60A, 240VAC OR EQUIVALENT WIRING GEN-10-AWG-PV-WIRE-CU WR1 270 FEET 1 10 AWG PV WIRE, COPPER (POSITIVE AND NEGATIVE) WIRING GEN-6-AWG-BARE-CU WR1 135 FEET 1 6 AWG BARE, COPPER (GROUND) WIRING GEN-10-AWG-THWN-2-CU-RD WR2 60 FEET 1 10 AWG THWN-2, COPPER, RED (POSITIVE) WIRING GEN-10-AWG-THWN-2-CU-BLK WR2 60 FEET 1 10 AWG THWN-2, COPPER, BLACK (NEGATIVE) WIRING GEN-10-AWG-THWN-2-CU-GR WR2-3 270 FEET 1 10 AWG THWN-2, COPPER (GROUND) WIRING GEN-8-AWG-THWN-2-CU-RD WR3 10 FEET 1 8 AWG THWN-2, COPPER, RED (LINE 1) WIRING GEN-8-AWG-THWN-2-CU-BLK WR3 10 FEET 1 8 AWG THWN-2, COPPER, BLACK (LINE 2) WIRING GEN-8-AWG-THWN-2-CU-WH WR3 10 FEET 1 8 AWG THWN-2, COPPER, WHITE (NEUTRAL) WIREWAY GEN-PVC-40-1.0" DIA WW2 20 FEET 1 PVC-40 CONDUIT, 1'' DIA WIREWAY GEN-PVC-80-1.0" DIA WW3-4 20 FEET 1 PVC-80 CONDUIT, 1'' DIA OCPD GENERIC MANUFACTURER GEN-CB-40A-240VAC CB1 1 PIECE 1 FUSE, 40A, 240VAC TRANSITION BOX GENERIC MANUFACTURER GEN-AWB-TB-4-4X JB1 1 PIECE 1 TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKS SYSTEM SUMMARY MPPT #1 MPPT #2 MPPT #3 MODULES IN SERIES 11 11 11 ARRAY VMP 424.6V 424.6V 424.6V ARRAY IMP 9.07A 9.07A 9.07A ARRAY VOC 517V 517V 517V ARRAY MAX VOC 597.9V 597.9V 597.9V ARRAY ISC 9.58A 9.58A 9.58A ARRAY STC POWER 11,550W ARRAY PTC POWER 10,616W MAX AC CURRENT 32A MAX AC POWER 7,680W DERATED (CEC) AC POWER 7,680W DESIGN TEMPERATURES ASHRAE EXTREME LOW -25.5°C (-13.9°F), SOURCE: DECATUR (39.98°; -88.87°) ASHRAE 2% HIGH 33.8°C (92.8°F), SOURCE: DECATUR (39.98°; -88.87°) INVERTERS REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1 1 SMA SB 7.7-1SP-US-40 (240V)240V FLOATING 40A 7680W 32A 3X18A 600V 97.0% MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-33 33 BOVIET BVM6612-350 350W 321.7W 9.58A 9.07A 47V 38.6V -0.146V/°C (-0.31%/°C)15A DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 SQUARE D DU222RB OR EQUIV.60A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1 1 40A 240VAC NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: FRONT PV ARRAY BACK !CAUTION! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: N E W S E-602.00 PLACARDS (SHEET 6 OF 19) MAIN DISTRIBUTION UTILITY DISCONNECT ! WARNING ! DUAL POWER SOURCES. SECOND SOURCE IS PV SYSTEM LABEL 6 PHOTOVOLTAIC AC DISCONNECT OPERATING CURRENT: 32 A AC OPERATING VOLTAGE: 240 V AC LABEL 5 AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690.54] ! WARNING ! ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LABEL 3 AT EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT [NEC 690.13 AND 690.15] PHOTOVOLTAIC AC DISCONNECT WARNING: PHOTOVOLTAIC POWER SOURCE LABEL 11 AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)] LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] LABEL 12 AT EACH AC DISCONNECTING MEANS [NEC 690.13(B)] ! CAUTION ! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING ! POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVISE LABEL 13 AT POINT OF INTERCONNECTION OVERCURRENT DEVICE [NEC 705.12(B)(2)(3)(B)] INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED LABEL 8 AT UTILITY METER [NEC 690.56(B)] PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL 10 AT RAPID SHUTDOWN SWITCH [NEC 690.56(C)]. LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] LABEL 7 LABELING NOTES 1.1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE RED BACKGROUND; “WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVE YELLOW BACKGROUND. [ANSI Z535] DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] PLAQUE AT POINT OF INTERCONNECTION; LABEL, SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFY PHOTOVOLTAIC SYSTEM [NEC 705.12(B)(4)] WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV SYSTEM DISCONNECTING MEANS. PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN BATHROOMS [NEC 690.4(D),(E)] SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS LABEL 1 AT RAPID SHUTDOWN SYSTEM [NEC 690.56(C)(1)(A)]. LABEL 3 INVERTER AT EACH APPLICABLE DC DISCONNECTING MEANS [NEC 690.53] OPERATING CURRENT: 9.07 A DC OPERATING VOLTAGE:424.6 V DC MAX SHORT CURRENT:9.58 A DC MAX VOLTAGE:597.9 V DC INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED WEST SIDE OF THE BUILDING SHEET KEYNOTES 1. ROOF MATERIAL: ASPHALT SHINGLE 2. ROOF STRUCTURE: TRUSS 3. ATTACHMENT TYPE: SNAPNRACK, A MOUNT 4. MODULE MANUFACTURER: BOVIET 5. MODULE MODEL: BVM6612-350 6. MODULE LENGTH: 77.01 IN. 7. MODULE WIDTH: 39.01 IN. 8. MODULE WEIGHT: 58.42 LBS. 9. SEE SHEET A-103 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 3'-0" FIRE ACCESS PATH 11. TRUSS SPACING: 24 IN. O.C. 12. TRUSS SIZE: 2X4 NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 2.5 IN. 15. TOTAL # OF ATTACHMENTS: 88 16. TOTAL AREA: 688.42 SQ. FT. 17. TOTAL WEIGHT: 1976.7 LBS. 18. WEIGHT PER ATTACHMENT: 22.46 LBS. 19. DISTRIBUTED LOAD: 2.87 PSF. 20. MAX. HORIZONTAL STANDOFF: 48 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 43 IN. 22. STANDOFF STAGGERING: NO 23. RAIL MANUFACTURER (OR EQUIV.): SNAPNRACK 24. RAIL MODEL (OR EQUIVALENT): SERIES 100 NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: S-501.00 ASSEMBLY DETAILS (SHEET 17 OF 19) SNAPNRACK B MOUNT ROCK-IN CHANNEL NUT ROW LINK 3D VIEW ROW LINK SIDE VIEW ROW LINK ROW LINK SHALL OCCUR WITHIN 1" TO 6" FROM THE NEAREST ADJACENT MODULE PANEL EDGE. SNAPNRACK FLASHTRACK COMP SNAPNRACK B MOUNT ROW LINK STANDARD MODULE (TYP.) SNAPNRACK B MOUNT. ROW LINK SHALL ONLY OCCUR BETWEEN TWO ROOF ATTACHMENTS IN THE SAME ROW. A DETAIL A SNAPNRACK A MOUNT SUPPORT SPACING (DISTANCE BETWEEN ROOF ATTACHMENTS). SEE APPROPRIATE ENGINEERING TABLES FOR MAXIMUM SUPPORT SPACING. SNAPNRACK C LINK SNAPNRACK B MOUNT SNAPNRACK A MOUNT LEVELER MODULE LEVELER BOLT SPACER, TO BE REMOVED WHEN C LINK FALLS ON MOUNT MIN 5.0 INCHES END OF FLASHING TO RDIGE MOUNT CLAMP BOLT** SNAPNRACK RIDGE EXTENSION MODULE A LEVLER H TRACK H TRACK FLASH TRACK FLASHING ROCK-IN/DROP-IN CHANNEL NUT (2) DETAIL A NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: R-001.00 RESOURCE DOCUMENTS (SHEET 18 OF 19) NEW PV SYSTEM: 11.550 kWp ENGINEER OF RECORD DATE:06.27.2019 DESIGN BY:A.L. CHECKED BY:M.M. DIRK STROBEL DENTIST OFFICE 59 PROFESSIONAL PLAZA REXBURG, ID 83440 PAPER SIZE: 36" x 24" (ARCH D) A B C D E F G H I J K L M N O 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H I J K L M N O CONTRACTOR BLUE MAX ENERGY & CONSULTING LLC PHONE:2085698777 LIC. NO.:RCE-47820 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. P P NO.DESCRIPTION DATE PROJECT REVISION / RELEASE SHEET NUMBER: SHEET TITLE: R-002.00 RESOURCE DOCUMENTS (SHEET 10 OF 19)