Loading...
HomeMy WebLinkAboutENGINEER APPROVAL LETTER - 19-00156 - Barney Self Storage Plus - Bldg 77/11 /19 Revised RE: DJ Barney Rexburg, ID 83440 Subject: Job# 19-1856-SDE Flat River Corp. 2257 E. 29th Ave. Columbus, NE 68602 Bldg. 75' x 100' x 9'-11" LS This letter is to certify the above referenced building will be designed in accordance with the applicable sections of the American [n stitute of Steel Construction (AlSC) and the American Iron and Steel Institute (A !SI) design procedures and good engineering practices for the following load s . Design Loads: Building Code: Risk Category Dead Load: Live Load : Roof Snow: Collateral Load: Wind Speed : IBC 2015 , Chapter 16 n Metal Building Structure Onl y 20 psf (Reduced) 36 .4 psf Heated 0.5 psf Ce= 1.00 Ct= 1.00 115 mph (ultimate wind speed ) Is = 1.00 Exp = C Porosity condition of building is : Enclosed Seismic Data Design Category Seismic Importance Factor: Spectural Response Coefficients: Site Cla ss (assumed): Basic Seismic Force Resisting System: Analysis Procedure: D 1.00 Ss = 0.440 SI= 0.156 Sds= 0 .425 Sdl = 0 .226 D Laterally= Light Frame Wall w/Shear Panels Longitudinall y= Light Frame Wall w/Shear Panels Simplified Analysis Procedure R = 6 .50 R = 6.50 The bu ye r is responsible for ensuring all specified loads are in compliance with local regulatory authorities . This letter of certification applies solely to the steel building system and its component parts and especially excludes an y foundation , masonry, general contra ct work, or parts supplied by anyone other than Flat River Corp . Building is to be erected in accordance with "FOR CONSTR UCTlON" erection drawings sealed by J. Walter Lewis, PE.